Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

FELIX-Based Readout of the Single-Phase ProtoDUNE Detector

Large liquid argon (LAr) time projection chambers (TPCs) have been adopted for the Deep Underground Neutrino Experiment (DUNE) experiment's far detector, which will be composed of four 17-kton detectors situated 1.5 km underground at the Sanford Underground Research Facility. This represents a large increase in scale compared to existing experiments. Both single- and dual-phase technologies will be validated at CERN, in cryostats capable of accommodating full-size detector modules, and exposed to low-energy charged particle beams. This program, called ProtoDUNE, also allows for extensive tests of data acquisition strategies. The Front-End LInk eXchange (FELIX) readout system was initially developed within the ATLAS collaboration and is based on custom field-programmable gate array (FPGA)-based Peripheral Component Interconnect Express input/output cards, connected through point-to-point links to the detector front end and hosted in commodity servers. FELIX will be used in the single-phase ProtoDUNE setup to read the data coming from 2560 anode wires organized in a single anode plane assembly (APS) structure. With a continuous readout at a sampling rate of 2 MHz, the system must deal with an input rate of 96 Gb/s. An external trigger will preselect time windows of 5 ms with interesting activity expected inside the detector. Event building will occur for triggered events, at a target rate of 25 Hz; the readout system will form fragments from the data samples matching the time window, carry out lossless compression, and forward the data to event building nodes over 10-Gb/s Ethernet. This paper discusses the design and implementation of this readout system as well as the first operational experience.

47 OTHER INSTRUMENTATION↗

SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the n oise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

Improved Charge Sensing on a SiMOS Double Quantum Dot using a Cryogenic Skipper Readout ASIC (Quandarum)

Major outstanding questions in high-energy physics such as the nature of dark matter and the existence of interactions beyond the standard model require new measurement techniques which are extremely sensitive to minute electromagnetic fields. An array of entangled spin qubits is a promising system for building novel detectors due to its combination of sensitivity and controllability. CMOS-based electron spin qubits, which have demonstrated the operational requirements for fault-tolerant quantum computing [1], offer a particular opportunity due to their compatibility with classical electronics, which allows the leveraging of decades of development of low-noise cryogenic detectors for physics. In this work, we combine a SiMOS double-quantum dot device architecture with a state-of-the-art cryoelectronic readout circuit [2-3] aimed to demonstrate improved charge readout using a single-electron transistor (SET). We identify the design characteristics for an SET that facilitate the use of on-chip classical electronics as a low-power, high-bandwidth first amplification stage and explore opportunities for sensor-readout co-design to minimize noise. This is the first of a series of steps to demonstrate high-fidelity readout of a large array of spin qubit with enough sensitivity to probe processes of interest for the investigation of beyond-standard-model physics.

Quinn, Adam [Fermilab]↗

Smart-readout of the Skipper-CCD: Achieving Sub-electron Noise Levels in Regions of Interest

The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by counting the exact number of electrons. The total readout time is proportional to the number of measurements of the charge in each pixel. For some applications this time may be too long; however, researchers usually are interested only on certain region within the matrix of pixels. In this paper we present the development of a smart skipper readout technique that allows the user to specify regions of interest of the CCD matrix where an arbitrary (high) number of measurements of the same charge can taken to obtain the desired noise level, and far less measurements are performed in those regions that are less interesting to the researcher, therefore reducing the total readout time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal photon and neutron imaging devices with fast event-by-event multisampling readout and optimized particle type discrimination

A particle imaging method for distinguishing between types of incident particles, such as neutrons, photons, and alphas, and improving the position resolution of particle imaging devices with matrix readout. The method includes high frequency multisampling readout electronics that provides the sequences of multiple measurements for each detected event, resulting in recorded detailed waveform information describing the signals. Such detailed information is used to approximate each signal waveform with a parameterized function in which the extracted parameter sets determine the type of the incident particle in an optimized fashion. The detailed event-by-event multisampling information for each signal readout channel in the matrix readout of the radiation imaging devices improves and optimizes the position resolution for variable shapes of the signals. Such devices can be used in mixed radiation fields, creating a new class of multimodal photon and neutron imagers.

Degtiarenko, Pavel V.↗

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

A microfabricated fringing field capacitive pH sensor with an integrated readout circuit

This work presents a microfabricated fringe-field capacitive pH sensor using interdigitated electrodes and an integrated modulation-based readout circuit. The changes in capacitance of the sensor result from the permittivity changes due to pH variations and are converted to frequency shifts using a crossed-coupled voltage controlled oscillator readout circuit. The shift in resonant frequency of the readout circuit is 30.96 MHz for a change in pH of 1.0–5.0. The sensor can be used for the measurement of low pH levels, such as gastric acid, and can be integrated with electronic pills. The measurement results show high repeatability, low noise, and a stable output.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Indium phosphide-based monolithically integrated PIN waveguide photodiode readout for resonant cantilever sensors

An integrated photodiode displacement readout scheme for a microelectromechanical cantilever waveguide resonator sensing platform is presented. III-V semiconductors are used to enable the monolithic integration of passive waveguides with active optical components. This work builds upon previously demonstrated results by measuring the displacement of cantilever waveguide resonators with on-chip waveguide PIN photodiodes. The on-chip integration of the readout provides an additional 70% improvement in mass sensitivity compared to off-chip photodetector designs due to measurement stability and minimized coupling loss. In addition to increased measurement stability, reduced packaging complexity is achieved due to the simplicity of the readout design. We have fabricated cantilever waveguides with integrated photodetectors and experimentally characterized these cantilever sensors with monolithically integrated PIN photodiodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D reconstruction of nuclear reactions using GEM TPC with planar readout

The research program of the Extreme Light Infrastructure – Nuclear Physics (ELI-NP) laboratory under construction in Magurele, Romania facilities the need of developing a gaseous active-target detector providing 3D reconstruction of charged products of nuclear reactions induced by gamma beam. The monoenergetic, high-energy (E{sub γ} > 19 MeV) gamma beam of intensity 10{sup 13}γ/s allows studying nuclear reactions in astrophysics. A Time Projection Chamber with crossed strip readout (eTPC) is proposed as one of the imaging detectors. The special feature of the readout electrode structure is a 2D reconstruction based on the information read out simultaneously from three arrays of strips that form virtual pixels. It is expected to reach similar spatial resolution as for pixel readout at largely reduced cost of electronics. The paper presents the current progress and first results of the small scale prototype TPC which is a one of implementation steps towards eTPC detector proposed in the Technical Design Report of Charged Particles Detection at ELI-NP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated wire harp and readout electronics inside vacuum

A wire harp is a well known instrument used in ion beam profile measurement and beam diagnostics. Till date, for beam instrumentation, the harp is placed inside the vacuum chamber or beam line in direct exposure to the beam profile to be measured, whereas the related readout electronics is placed outside somewhere at a convenient place. Here, a harp has been developed along with the readout electronics as an integrated part of it and both were placed inside the beam line vacuum (order of 10{sup −7} Torr) to make the system much simpler, easy to operate, and measure small beam current more accurately. The entire signal conversion and processing is done inside the vacuum unlike other systems; hence, the electronics is kept inside. This results in a lesser number (only 4 pin) of electrical connections (feedthrough) including power which otherwise would have required 32 feedthrough pins only for signal readout for a 13 × 13 (X × Y) channel harp. This paper describes a completely new approach to the design of a conventional beam harp widely used for beam instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SLAC microresonator RF(SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Here, we describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

47 OTHER INSTRUMENTATION↗

ALICE inner tracking system readout electronics prototype testing with the CERN "Giga Bit Transceiver''

The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.

47 OTHER INSTRUMENTATION↗

The upgrade of the ALICE TPC with GEMs and continuous readout

The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.

47 OTHER INSTRUMENTATION↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗