Elucidating the Nature of Pseudo Jahn-Teller Distortions in Li x MnPO 4 : Combining Density Functional Theory with Soft and Hard X-ray Spectroscopy
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided
We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.
X-ray cavities are key tracers of mechanical (or radio mode) heating arising from the active galactic nuclei (AGNs) in brightest cluster galaxies (BCGs). We report on a survey for X-ray cavities in 83 massive, high-redshift (0.4 7 Gyr at z∼0.8). On average, the detected X-ray cavities have powers of (0.8−5)×10{sup 45} erg s{sup −1}, enthalpies of (3−6)×10{sup 59} erg, and radii of ∼17 kpc. Integrating over 7 Gyr, we find that the supermassive black holes in BCGs may have accreted 10{sup 8} to several 10{sup 9} M{sub ⊙} of material to power these outflows. This level of accretion indicates that significant supermassive black hole growth may occur not only at early times, in the quasar era, but at late times as well. We also find that X-ray cavities at high redshift may inject an excess heat of 0.1–1.0 keV per particle into the hot ICM above and beyond the energy needed to offset cooling. Although this result needs to be confirmed, we note that the magnitude of excess heating is similar to the energy needed to preheat clusters, break self-similarity, and explain the excess entropy in hot atmospheres.
Abstract not provided
The maximum cosmic-ray energy achievable by acceleration by a relativistic blast wave is derived. It is shown that forward shocks from long gamma-ray bursts (GRBs) in the interstellar medium accelerate protons to large enough energies, and have a sufficient energy budget, to produce the Galactic cosmic-ray component just below the ankle at 4 x 10{sup 18} eV, as per an earlier suggestion. It is further argued that, were extragalactic long GRBs responsible for the component above the ankle as well, the occasional Galactic GRB within the solar circle would contribute more than the observational limits on the outward flux from the solar circle, unless an avoidance scenario, such as intermittency and/or beaming, allows the present-day local flux to be less than 10{sup -3} of the average. Difficulties with these avoidance scenarios are noted.
Explore the source record for details and available documents.
We report a new synchrotron based in situ X-ray diffraction (XRD) technique to study the chemical delithiation of LiFePO{sub 4}. This technique provides a new powerful tool to study chemical reactions with excellent time-resolving power for dynamic studies.
A high-speed one-dimensional detector for time-resolved small-angle x-ray scattering has been designed and built for experiments at the Advanced Photon Source of Argonne National Laboratory. This detector is made from a 500-?m thick by 150-mm diameter ultra-high-purity n-type silicon wafer. The electrodes, which are a series of concentric rings that are deposited in the wafer, integrate the scattered x-rays over the azimuthal angle and, thereby, produce a one-dimensional detector. This design yields 128 rings, which allows parallel processing of the signal from each ring. The readout electronics consist of transimpedance front-end amplifiers, one for each ring, followed by active pulse-shaping filters. The amplifier signals are digitized using 12-bit analog-to-digital converters, one per ring, which operate at 20 MHz. The frame rate of the system is 271 kHz. Up to 220 - 1 scattering profiles may be stored on a random access memory chip and transferred to a data file at a rate of 16 x 103 profiles/sec. For X-ray energies between 3.5 and 13.2 keV the efficiency exceeds 80%. The resolving time of the electronics is 300 ns, which is sufficient to isolate electronically a single pulse of scattered x-rays when the synchrotron is operated in a hybrid or asymmetric fill pattern. Therefore, laser-pump/x-ray-probe experiments can be performed without a mechanical shutter. Examples of time-resolved speckle and the kinetics of the formation of sodium chloride particles are presented. This detector is capable of acquiring small-angle x-ray scattering profiles over multiple time scales, which are needed to characterize many chemical, physical, and biological processes. In addition, this detector may be tested and calibrated before experimental runs, without access to an intense beam of x-rays, with alpha particles from a radioactive source such as 241Am.
Trace metals play critical roles in a variety of systems, ranging from cells to photovoltaics. X-Ray Fluorescence (XRF) microscopy using X-ray excitation provides one of the highest sensitivities available for imaging the distribution of trace metals at sub-100 nm resolution. With the growing availability and increasing performance of synchrotron light source based instruments and X-ray nanofocusing optics, and with improvements in energy-dispersive XRF detectors, what are the factors that limit trace element detectability? To address this question, we describe an analytical model for the total signal incident on XRF detectors with various geometries, including the spectral response of energy dispersive detectors. This model agrees well with experimentally recorded X-ray fluorescence spectra, and involves much shorter calculation times than with Monte Carlo simulations. With such a model, one can estimate the signal when a trace element is illuminated with an X-ray beam, and when just the surrounding non-fluorescent material is illuminated. From this signal difference, a contrast parameter can be calculated and this can in turn be used to calculate the signal-to-noise ratio (S/N) for detecting a certain elemental concentration. We apply this model to the detection of trace amounts of zinc in biological materials, and to the detection of small quantities of arsenic in semiconductors. We conclude that increased detector collection solid angle is (nearly) always advantageous even when considering the scattered signal. However, given the choice between a smaller detector at 90° to the beam versus a larger detector at 180° (in a backscatter-like geometry), the 90° detector is better for trace element detection in thick samples, while the larger detector in 180° geometry is better suited to trace element detection in thin samples.
Electron-hole separation following hard X-ray absorption during diffraction analysis of soft materials under cryogenic conditions produces substantial local electric fields visualizable by second harmonic generation (SHG) microscopy. Monte Carlo simulations of X-ray photoelectron trajectories suggest the formation of substantial local electric fields in the regions adjacent to those exposed to X-rays, indicating a possible electric-field-induced SHG (EFISH) mechanism for generating the observed signal. In studies of amorphous vitreous solvents, analysis of the SHG spatial profiles following X-ray microbeam exposure was consistent with an EFISH mechanism. Within protein crystals, exposure to 12-keV (1.033-angstrom) X-rays resulted in increased SHG in the region extending similar to 3 mu m beyond the borders of the X-ray beam. Moderate X-ray exposures typical of those used for crystal centering by raster scanning through an X-ray beam were sufficient to produce static electric fields easily detectable by SHG. The X-ray-induced SHG activity was observed with no measurable loss for longer than 2 wk while maintained under cryogenic conditions, but disappeared if annealed to room temperature for a few seconds. These results provide direct experimental observables capable of validating simulations of X-ray-induced damage within soft materials. In addition, X-ray-induced local fields may potentially impact diffraction resolution through localized piezoelectric distortions of the lattice.
In situ synchrotron energy dispersive x-ray diffraction (XRD) experiments on Nb have been conducted at pressures up to 6.4 GPa and temperatures up to 1073 K. From the pressure-volume-temperature measurements, thermoelastic parameters were derived for the first time for Nb based on the thermal pressure (ΔP{sub th}) equation of state (EOS), modified high-T Birch-Murnaghan EOS, and Mie-Grüneisen-Debye EOS. With the pressure derivative of the bulk modulus K{sub T}{sup ´} fixed at 4.0, we obtained the ambient isothermal bulk modulus K{sub T0}=174(5) GPa, the temperature derivative of bulk modulus at constant pressure (∂K{sub T}/∂T){sub P}=-0.060(8) GPa K⁻¹ and at constant volume (∂K{sub T}/∂T){sub V}=-0.046(8) GPa K⁻¹, the volumetric thermal expansivity α{sub T}(T)=2.3(3)×10⁻⁵+0.3(2)×10⁻⁸T (K⁻¹), as well as the pressure dependence of thermal expansion (∂α/∂P){sub T}=(₋2.0±0.4)×10⁻⁶ K⁻¹ GPa⁻¹. Fitting the present data to the Mie-Grüneisen-Debye EOS with Debye temperature Θ₀=276.6 K gives γ₀=1.27(8) and K{sub T0}=171(3) GPa at a fixed value of q=3.0. The ambient isothermal bulk modulus and Grüneisen parameter derived from this work are comparable to previously reported values from both experimental and theoretical studies. An in situ high-resolution, angle dispersive XRD study on Nb did not indicate any anomalous behavior related to pressure-induced electronic topological transitions at ~5 GPa as has been reported previously.
Abstract not provided
XISF is a MATLAB program developed to separate intermolecular structure factors from total X-ray scattering structure factors for molecular liquids and amorphous solids. The program is built on a trust-region-reflective optimization routine with the r.m.s. deviations of atoms physically constrained. XISF has been optimized for performance and can separate intermolecular structure factors of complex molecules.
We present the Fermi Gamma-ray Burst Monitor (GBM) and Large Area Telescope (LAT) observations of the LIGO binary black hole merger event GW151226 and candidate LVT151012. At the time of the LIGO triggers on LVT151012 and GW151226, GBM was observing 68% and 83% of the localization regions, and LAT was observing 47% and 32%, respectively. No candidate electromagnetic counterparts were detected by either the GBM or LAT. We present a detailed analysis of the GBM and LAT data over a range of timescales from seconds to years, using automated pipelines and new techniques for characterizing the flux upper bounds across large areas of the sky. Due to the partial GBM and LAT coverage of the large LIGO localization regions at the trigger times for both events, differences in source distances and masses, as well as the uncertain degree to which emission from these sources could be beamed, these non-detections cannot be used to constrain the variety of theoretical models recently applied to explain the candidate GBM counterpart to GW150914.
We report a hard x-ray patterning capable of drawing lines with a width below 100 nm using x-rays at 0.165 nm. A specially prepared mask based on multilayer growth technology was used as an x-ray mask effectively. The x-ray Talbot effect in near field was investigated and utilized in the patterning. Since multilayers with a few nanometer layer spacing are readily available, the proposed hard x-ray nano patterning, free of the limit imposed by the Rayleigh criterion in optical range, can potentially be an ultimate optical lithography technique.