Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAMAN SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measuring Plant Metabolite Abundance in Spearmint ( Mentha spicata L.) with Raman Spectra to Determine Optimal Harvest Time

A fast field-deployable method utilizing Raman spectroscopy to determine the optimal harvest time of plants to extract the highest abundance of target metabolites is presented. Rosmarinic acid is a metabolite extracted from spearmint (Mentha spicata L.). Leaves from commercial “Native” and proprietary clonal line “KI110” spearmint were measured as a function of cell type and age to determine rosmarinic acid abundance. A linear regression model with leave-one-out cross-validation (R 2 CV = 0.61, RMSECV = 11.1 mg/g) was developed between selected Raman peak areas and rosmarinic acid concentrations determined by high-performance liquid chromatography (HPLC). A principal component analysis (PCA) model was also developed to determine rosmarinic acid abundance. The method may be suited to the analysis of many agriculturally relevant plant species and metabolites with distinct Raman peaks.

59 BASIC BIOLOGICAL SCIENCES↗

Additional complexity in the Raman spectra of U 3 O 8

Uranium oxides are readily amenable to investigation using Raman spectroscopy, and this approach is frequently used as a chemical analysis tool. We show, in triuranium octoxide (U 3 O 8 ), the presence of previously unreported Raman peaks located below 100 cm ₋1 . By maximum intensity, the strongest peak in U 3 O 8 appears at 54 cm ₋1 and is resolution limited, making this mode an ideal candidate for chemically identifying U 3 O 8 using Raman spectroscopy. Detailed peak analysis suggests that the main spectral feature between 300 and 500 cm ₋1 is more accurately described by a septet than a triplet. Two samples of differing oxygen content show only minor differences in bulk crystal structure, but subtle changes in lattice dynamics are suggestive of defect scattering in analogy to UO 2+x .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of picosecond coherent anti-Stokes Raman spectra for gas-phase diagnostics

We present a hybrid frequency- and time-domain solution, applicable to the case of picosecond coherent anti-Stokes Raman scattering (CARS), for gas-phase diagnostics. A solution has been derived based on both physical arguments and four-wave mixing equations for picosecond CARS, with pulse durations that are comparable to the dephasing time scale for gas-phase Raman coherence—a regime where commonly employed solutions for impulsive (femtosecond) or cw (nanosecond) pump/Stokes forcing are not strictly valid. We present the ps-CARS spectrum in the form of incoherent sums of CARS intensity spectra, calculated from the fundamental solution for impulsive pump/Stokes Raman preparation. The solution was examined for temperatures from 1000–3000 K, for four plausible experimental configurations, with laser pulse durations of 50–150 ps, and probe pulse delays from −20 to 240 ps. Approximations based on cw and impulsive pump/Stokes preparation to fit picosecond CARS spectra at atmospheric pressure were examined and the relative thermometric accuracy and computational cost of these approximations were quantified for the case of a zero nonresonant CARS contribution, and a nonresonant susceptibility equal to 10% of the Raman-resonant value at the N 2 bandhead. The nanosecond CARS approximation can result in large fitting errors when the probe pulse time delay is less than the probe pulse duration. Errors as large as 10–20% are observed in the fit temperatures for a zero picosecond probe pulse delay, when the nonresonant background is neglected, largely due to an inability of the time-independent cw model to capture transient frequency spread dephasing effects at the Q -branch bandhead. The inclusion of a nonresonant background results in 40–60% thermometry errors with a nanosecond model at a zero-probe delay. Time-dependent impulsive calculations used for femtosecond CARS better approximate the structure of the N 2 bandhead, reducing temperature fitting errors to 5–10% at a short probe pulse delay. The impulsive approximation results in errors up to 10% at intermediate probe pulse delays, where the coherence of the pump and probe pulses leads to multiple terms in the picosecond CARS solution. Both approximations improve as the probe pulse delay exceeds the probe duration. The nanosecond approximation results in a 2–3% error, while the impulsive model results in differences of less than 1% in some cases. Fits to experimental data obtained using short, ∼60ps pulses at a zero probe time delay and longer 100 ps pulses at a substantial 200 ps delay are presented with accuracies of 1–3% in the fit temperature.

Kearney, Sean P.↗

Pulsed cathodoluminescence and Raman spectra of MoS{sub 2} and WS{sub 2} nanocrystals and their combination MoS{sub 2}/WS{sub 2} produced by self-propagating high-temperature synthesis

Molybdenum and tungsten disulfide nanoplates were produced by self-propagating high-temperature synthesis in argon atmosphere. This method provides an easy way to produce MoS{sub 2} and WS{sub 2} from nanoplates up to single- and several layers. The Raman peak intensities corresponding to in-plane E{sup 1}{sub 2g} and out-of-plane A{sub 1g} vibration modes and their shifts strongly depend on the thicknesses of the MoS{sub 2} and WS{sub 2} platelets indicating size-dependent scaling laws and properties. An electron beam irradiation of MoS{sub 2} and WS{sub 2} powders leads to an occurrence of pulsed cathodoluminescence (PCL) spectra at 575 nm (2.15 eV) and 550 nm (2.25 eV) characteristic to their intrinsic band gaps. For the combination of MoS{sub 2} and WS{sub 2} nanopowders, a PCL shoulder at 430 nm (2.88 eV) was observed, which is explained by the radiative electron-hole recombination at the MoS{sub 2}/WS{sub 2} grain boundaries. The luminescence decay kinetics of the MoS{sub 2}/WS{sub 2} nanoplates appears to be slower than for individual MoS{sub 2} and WS{sub 2} platelets due to a spatial separation of electrons and holes at MoS{sub 2}/WS{sub 2} junction resulting in extension of recombination time.

36 MATERIALS SCIENCE↗

Computationally-Guided Assignment of Unexpected Signals in the Raman Spectra of Uranyl Triperoxide Complexes

Combination of uranium, peroxide, and mono- (Na, K) or divalent (Mg, Ca, Sr) cations under alkaline aqueous conditions results in the rapid formation of anionic uranyl triperoxide monomers (UTs), (UO 2 (O 2 ) 3 ) 4– , exhibiting unique Raman signatures. Electronic structure calculations were decisive for the interpretation of the spectra and assignment of unexpected signals associated with vibrations of the uranyl and peroxide ions. Finally, assignments were verified by 18 O isotopic labeling of the uranyl ions supporting the computational-based interpretation of the experimentally observed peaks and the assignment of a novel asymmetric vibration of the peroxide ligands, v2 (O 2 2– ).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗

Raman spectroscopy of neutron irradiated silicon carbide: Correlation among Raman spectra, swelling, and irradiation temperature

The effects of neutron irradiation on microstructural evolution and the resultant changes in physical and mechanical properties are of critical importance for the development of silicon carbide (SiC) materials for nuclear applications. This study neutron–irradiated β–SiC under a wide range of conditions at temperatures between 235 and 750°C and neutron doses of 0.01–11.8 displacements per atom, and then evaluated the effects on the SiC structure using Raman spectroscopy. The SiC optical phonon lines were shifted to lower wavenumbers by irradiation. Correlations were found among the wavenumber of the longitudinal optical phonon line, irradiation–induced swelling, and irradiation temperature. The peak shift also correlated indirectly with decreasing thermal conductivity of irradiated SiC. The irradiation–induced peak shift is explained by combinations of lattice strain, reduction of the elastic modulus, and other factors including decreasing coherent domain size. Lastly, these findings bridge irradiation–induced microstructural changes and property changes and illustrate how Raman spectroscopy is a useful tool for nondestructively assessing irradiated SiC materials for nuclear applications.

36 MATERIALS SCIENCE↗

Raman Spectra of U3Ox

Explore the source record for details and available documents.

Miskowiec, Andrew [ORNL] (ORCID:0000000203612614)↗