Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optimizing Long-term Monitoring of Radiation Air Dose Rates - 19169

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (NPP) have been steadily decreasing over the past seven years since the accident in March 2011. After seven years, the radiation monitoring program is expected to transition from short-term emergency responses to long-term monitoring. The objectives of long-term monitoring are often different from early emergency responses, since extensive data accumulation has led to an understanding of contaminant distributions and mobility. The main long-term monitoring objectives are (1) to confirm system stability and the continuing reduction of contaminant and hazard levels, (2) to provide assurance for the public, (3) to accumulate the basic datasets for scientific knowledge and future preparation, and (4) to detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the sampling locations of radiation air dose-rate monitoring. Three steps are taken in order to determine sampling locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations across the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air dose rates across the domain. In the second step, we use a Gaussian mixture model to identify the representative locations in multiple environmental variables, such as elevation and land-cover types. In the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air dose rates across the domain. We use the integrated dose-rate map from the Bayesian geostatistical method as the reference map and distribute the sampling in such a way as to capture the heterogeneity of the reference map. Although we assume hypothetical sets of measurement locations to evaluate the performance of the methodology and algorithms, we have demonstrated this approach using real, spatially extensive datasets, including the integrated air-dose-rate map of 2016. Our results have shown that this approach allows us to add sampling locations in a systematic manner. Increasing the number of sampling locations can better capture the heterogeneity of dose rates, although the estimation error does not decrease further after a certain number of samples. We have also found that when there are restrictions such as pre-existing monitoring locations or the ones along roads, the spatial estimation becomes poor even with the same number of monitoring locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Russian-Norwegian Cooperation In Regulation of the Public Radiation Protection in the Northwest Russia - 12440

In 1960's, the large technical bases of the Northern Fleet were arranged on the Kola Peninsula. These bases were involved in support of nuclear submarines performing acceptance and storage of radioactive waste (RW) and spent nuclear fuel (SNF). Since 1985, the waste acceptance has been stopped and the technical bases changed their functions to serve as sites of temporary storage (STS). According to the RF Government Directive of 09 February 2000 No 220-r, the STS were put under Rosatom responsibility in order to conduct operations dealing with the SNF and RW management being accumulated during the naval activity and originated from dismantlement of nuclear submarines and surface ships equipped with nuclear powered installations, as well as to carry out environmental remediation of radiation hazardous facilities in this region. The international collaborative assistance is very important to increase effectiveness of such works. This paper includes the findings of cooperation between the Federal Medical Biological Agency (FMBA) and Norwegian Radiation Protection Authority (NRPA) in radiation protection of the public in the course of the STS remediation. Since 2004, the following works has been carried out in this direction: - radiation threat assessment and identification of the priority directions of radiation and hygienic studies; - radiation situation inspections on-site and within the coastal offshore waters at different stage of remediation; - development of the documents including the criteria for the STS remediation and guidelines for radiation monitoring to control the mentioned criteria compliance; - development of the radio-ecological geo-information system. The developed criteria consider four basic options of the STS remediation - renovation, conversion, conservation and liquidation. The main (dose) and derived remediation levels have been determined for each option. The resulted from monitoring radiation parameters - including contents of {sup 137}Cs, {sup 90}Sr and {sup 60}Co in samples of soil, vegetation, seawater, seaweeds, bottom sediments, invertebrates and vertebrates, gamma dose rate values - are integrated in the database, which is the component of the geo-information system. The developed regulative and methodical documents and the geo-information system have been introduced in Regional Management-120 under FMBA of Russia, which is responsible for the radiation safety supervision, Centre of Hygiene and Epidemiology-120 under FMBA of Russia, which carries out regulatory radiation control, and in the operating organization involved in the STS remediation and responsible for radiation protection of workers and public. The works completed have permitted to solve the majority of problems in enhancement of radiation and hygienic supervision of SevRAO operation. However, some relevant questions in this area need additional efforts. In particular, in the course of specification of the design solutions, obtaining additional data on the radiation situation parameters and clarification of the prognostic assessments, the necessity will certainly arise to amend the regulatory documents taking the adopted design solutions into account. We are on the way to real results. Much has been done for the first time, and although it is difficult to foresee all future problems and challenges, our knowledge, experience and close cooperation permit to assess the prospects confidently. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving operational performance using machine learning analysis of Radiation Portal Monitor measurements

Radiation Portal Monitors (RPMs) have been installed worldwide to scan vehicles and cargo for the presence of radiological and nuclear materials. In field operations, the sensitivity of these systems is typically limited by the relatively high rates of nuisance alarms that usually must be followed up with secondary inspections. We have developed a machine-learning based alarm analysis system that has been deployed at numerous locations in the U.S. and internationally. Our Enhanced Radiological Nuclear Inspection and Evaluation (ERNIE) analysis software and its derivatives have demonstrated increased sensitivity to radiological and nuclear material of concern while reducing nuisance alarms by as much as an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of synoptic scale moisture and wind field analyses using the Nimbus 4 THIR 6.7 micron observations

The Nimbus 4 temperature-humidity infrared radiometer (THIR) monitors radiation in the 6.5 to 7.2 micron water vapor absorption with a 23 kilometer spatial resolution at the sub-satellite point. Radiation monitored in this spectral region results primarily from emission in the 250 to 500 millibar region of the upper troposphere. The THIR 6.7 micron observations are readily available in photofacsimile imagery form which shows very distinctive patterns associated with spatial variations in atmospheric water vapor. These radiometric observations were combined in several instances with moisture values measured in the upper troposphere by the standard radiosonde network. In each instance, the result is a much more consistent analysis showing increased spatial detail that agrees with the radiometric observations and does not compromise the conventional data. The improved moisture analyses show relatively dry and moist tongues that are very difficult or impossible to infer from the conventional data alone. The patterns in the moisture fields can be tracked over 12 and 24 hour periods. In addition, by keeping in mind the advective properties of the moisture field, success was achieved in improving streamline analyses at the 400 mb level over data sparse regions on a global scale.

Steranko, J.↗

Application of Nimbus 4 THIR 6.7-micron observations to regional and global moisture and wind field analyses.

The Nimbus 4 temperature-humidity infrared radiometer (THIR) monitors radiation in the 6.5 to 7.2-micron water vapor absorption region with a 23-km spatial resolution at the subsatellite point. Radiation monitored in this spectral region results primarily from emission in the 250 to 500-mb region of the upper troposphere. The THIR 6.7-micron observations are readily available in photofacsimile imagery form which shows very distinctive patterns associated with spatial variations in atmospheric water vapor. These radiometric observations have been combined in several instances with moisture values measured in the upper troposphere by the standard radiosonde network. In each instance, the result is a much more consistent analysis showing increased spatial detail that agrees with the radiometric observations and does not compromise the conventional data. The improved moisture analyses show relatively dry and moist tongues that are very difficult or impossible to infer from the conventional data alone.

Steranka, J.↗

Life Sciences and Space Research 25 (2) Radiation Biology: Topical Meeting of the COSPAR Interdisciplinary Scientific Commission F of the COSPAR 29th Plenary Meeting, Washington, DC, Aug. 28-Sep. 5, 1992

Papers presented on long-term exposure to ionizing radiation, obtained from the Long Duration Exposure Facility, included radiation monitoring, radiation effects, and dosimetry. Mechanisms of biological systems, especially cells, under ionizing radiation and relative biological effectiveness were compared. The role of HZE particles as agents of mutation were reported from plant, animal, and in vitro models. Data on known and predicted effects of cosmic rays and other solar radiation on biological systems included differences related to Linear Energy Transfer and heavy ion particles.

Horneck, G.↗

Lab-Based Measurement of Remediation Techniques for Radiation Portal Monitors (Initial Report)

Radiation Portal Monitors (RPM) deployed by the Second Line of Defense (SLD) are known to be sensitive to the natural environmental radioactive background. There are several techniques used to mitigate the effects of background on the monitors, but since the installation environments can vary significantly from one another the need for a standardized, systematic, study of remediation techniques was proposed and carried out. This study is not meant to serve as the absolute last word on the subject. The data collected are, however, intelligible and useful. Some compromises were made, each of which will be described in detail. The hope of this initial report is to familiarize the SLD science teams with ORNL's effort to model the effect of various remediation techniques on simple, static backgrounds. This study provides a good start toward benchmarking the model, and each additional increment of data will serve to make the model more robust. The scope of this initial study is limited to a few basic cases. Its purpose is to prove the utility of lab-based study of remediation techniques and serve as a standard data set for future use. This importance of this first step of standardization will become obvious when science teams are working in parallel on issues of remediation; having a common starting point will do away with one category of difference, thereby making easier the task of determining the sources of disagreement. Further measurements will augment this data set, allowing for further constraint of the universe of possible situations. As will be discussed in the 'Going Forward' section, more data will be included in the final report of this work. Of particular interest will be the data taken with the official TSA lead collimators, which will provide more direct results for comparison with installation data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TH-E-209-00: Radiation Dose Monitoring and Protocol Management

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Humanoid Flight Metabolic Simulator Project

NASA's Evolvable Mars Campaign (EMC) has identified several areas of technology that will require significant improvements in terms of performance, capacity, and efficiency, in order to make a manned mission to Mars possible. These include crew vehicle Environmental Control and Life Support System (ECLSS), EVA suit Portable Life Support System (PLSS) and Information Systems, autonomous environmental monitoring, radiation exposure monitoring and protection, and vehicle thermal control systems (TCS). (MADMACS) in a Suit can be configured to simulate human metabolism, consuming crew resources (oxygen) in the process. In addition to providing support for testing Life Support on unmanned flights, MADMACS will also support testing of suit thermal controls, and monitor radiation exposure, body zone temperatures, moisture, and loads.

Ross, Stuart↗

Radiation area monitor device and method

A radiation area monitor device/method, utilizing: a radiation sensor; a rotating radiation shield disposed about the radiation sensor, wherein the rotating radiation shield defines one or more ports that are transparent to radiation; and a processor operable for analyzing and storing a radiation fingerprint acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor. Optionally, the radiation sensor includes a gamma and/or neutron radiation sensor. The device/method selectively operates in: a first supervised mode during which a baseline radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor; and a second unsupervised mode during which a subsequent radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor, wherein the subsequent radiation fingerprint is compared to the baseline radiation fingerprint and, if a predetermined difference threshold is exceeded, an alert is issued.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation area monitor device and method

A radiation area monitor device/method, utilizing: a radiation sensor having a directional radiation sensing capability; a rotation mechanism operable for selectively rotating the radiation sensor such that the directional radiation sensing capability selectively sweeps an area of interest; and a processor operable for analyzing and storing a radiation fingerprint acquired by the radiation sensor as the directional radiation sensing capability selectively sweeps the area of interest. Optionally, the radiation sensor includes a gamma and/or neutron radiation sensor. The device/method selectively operates in: a first supervised mode during which a baseline radiation fingerprint is acquired by the radiation sensor; and a second unsupervised mode during which a subsequent radiation fingerprint is acquired by the radiation sensor, wherein the subsequent radiation fingerprint is compared to the baseline radiation fingerprint and, if a predetermined difference threshold is exceeded, an alert is issued.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of mixed sources with an organic scintillator-based radiation portal monitor

We have developed radionuclide identification algorithms for radiation portal monitor applications. One algorithm uses a spectral angle mapper to match the power spectral density of modified cumulative distribution functions of measured pulse height distributions to reference spectra, while the others rely on the decomposition of the observed spectrum as a linear mixture of known radionuclide spectra. Three algorithms were then tested for their ability to perform on-the-fly radionuclide identification on datasets acquired with a liquid organic scintillator-based pedestrian radiation portal monitor on moving special nuclear material and industrial radiological sources, as well as common medical isotopes. We quantified and compared the relative efficacies of the algorithms considered using F-score analysis. Measured radiation sources included 51 g of highly enriched uranium, 6.6 g of weapons grade plutonium, 241 Am, 133 Ba, 57 Co and 137 Cs sources with activities of several hundred kBq, as well as 260 kBq liquid solution samples of the medical isotopes 99m Tc, 111 In, 67 Ga, 123 I, 131 I, and 201 Tl. We achieved 100% positive identification, for three-second measurements of single sources moving at a source-transit speed of 1.2 m/s. For mixed sources with strongest and weakest sources having no more than a 5:1 ratio of detected counts, encouraging positive identification results were achieved with the un-mixing algorithms. Current radiation portal monitor designs suffer from a high incidence rate of nuisance radiation alarms caused in radiation portal monitor primary screenings by recent nuclear medicine patients and cargo containing large amounts of naturally occurring radioactive materials. Integrating reliable on-the-fly radionuclide identification into the radiation portal monitors could lower the number of nuisance alarms requiring time-consuming secondary inspections.

47 OTHER INSTRUMENTATION↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Nuisance Alarm Reductions In Organic Scintillation Detector-Based Radiation Portal Monitors

A worldwide system of radiation portal monitors (RPMs) detects and deters the smuggling of special nuclear material (SNM) and other radiological sources that could be used by terrorist organizations in an improvised nuclear device or a radiological dispersal device. Nuisance alarms from non-SNM sources of radiation, however, account for the vast majority of RPM radiation alarms. We present research on a liquid organic scintillation detector-based RPM that reduces the impact of nuisance alarms through on-the- fly radionuclide identification. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic liquid scintillation detector shape and volume impact on radiation portal monitors

We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3 He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. As a result, a small number of organic liquid scintillation detectors could therefore be a valid alternative to 3 He in some RPM applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗