All-Particle Spectrum Measured by the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC), a balloon-borne experiment, is designed to investigate the composition and energy spectra of cosmic rays of charge Z = 1 to 26 over the energy range - 10(exp 11) - 10(exp 14) ev. The instrument consists of a silicon matrix charge detector, plastic-scintillator strip hodoscopes interleaved with graphite interaction targets, and an 18 radiation length deep, fully active bismuth germanate (BGO) calorimeter. ATIC has had two successful long duration balloon (LDB) flights launched from McMurdo Station, Antarc't'ica in 2000 and 2002. In this paper, we present the all-particle spectrum extracted from data collected during the ATIC flights, and compare it with results from other experiments at both lower and higher energies.

Ahn, H. S.↗

Grid Window Tests on an 805-MHz Pillbox Cavity

Muon ionization cooling channel designs use pillbox shaped RF cavities for improved power efficiency and fine control over phasing of individual cavities. For minimum scattering of the muon beam, the ends should be made out of a small thickness of high radiation length material. Good electrical and thermal conductivity are required to reduce power dissipation and remove the heat efficiently. Thin curved beryllium windows with TiN coating have been used successfully in the past. We have built an alternative win- dow set consisting of grids of tubes and tested these on a pillbox cavity previously used with both thin Be and thick Cu windows. The cavity was operated with a pair of grids as well as a single grid against a flat endplate.

43 PARTICLE ACCELERATORS↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New experimental results for a vector boson A

The search for a new vector boson, $A'$, in the test run of A' EXperiment (APEX) results in a limit for a weak coupling $\alpha' \ga 10^{-6} \alpha$ to electrons ($\alpha=e^2/4\pi$) in the mass range 175 MeV $< m_{A'} <$ 250 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the ``dark photon'' $A'$ with the photon --- one of the very few ways in which new forces can couple to the Standard Model --- and have received considerable attention as an explanation of various dark matter related anomalies. $A'$ bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident $e^+e^-$ spectrum. We plan to search for the $A'$ by using the CEBAF electron beam at energies of $\approx$ 1--4 GeV incident on $0.5-10\%$ radiation length multi-foil Tungsten targets, and measure the resulting $e^+e^-$ pairs using the High Resolution Spectrometers and a septum magnet in Hall A at Jefferson Lab. With a 33-day run, the experiment will achieve very good sensitivity because the statistics of $e^+e^-$ pairs will be $\sim 10,000$ times larger in the explored mass range than in any previous search for the $A'$ boson. This talk will discuss the experiment and present the

Wojtsekhowski, Bogdan↗

Experimental search for a new vector boson A'

The A? EXperiment (APEX) will search for a new vector boson, A?, with weak coupling ?? & 6 × 10?8? to electrons (? = e2/4?) in the mass range 65 MeV < mA? < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the ?dark photon? A? with the photon ? one of the very few ways in which new forces can couple to the Standard Model ? and have received considerable attention as an explanation of various dark matter related anomalies. A? bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e+e? spectrum. We plan to search for the A? by using the CEBAF electron beam at energies of ? 1?4 GeV incident on 0.5?10% radiation length multi-foil Tungsten targets, and measure the resulting e+e? pairs using the High Resolution Spectrometers and a septum magnet in Hall A at Jefferson Lab. With a 33-day run, the experiment will achieve very good sensitivity because the statistics of e + e? pairs will be ? 10, 000 times larger in the explored mass range than any previous search for the A? boson. This talk will discuss the experiment and present the results of a pilot run.

Wojtsekhowski, Bogdan↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Measurement of Coherence Length in UndulAtor RAdiation (CLARA): Run 4 Proposal

The goal of the proposed experimental research is to investigate the quantum nature of “a particle in a ring” by studying a single 135-MeV electron, circulating in the IOTA storage ring and interacting with an undulator through single- and multi-photon emissions. The focus of this proposal will be two-photon undulator emissions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Role of pump coherence in two-photon interferometry

We use a parametric down-conversion source pumped by a short-coherence-length continuous-wave (CW) diode laser to perform two-photon interferometry in an intermediate regime between the more familiar Franson-type experiments with a long-coherence-length pump laser, and the short pulsed pump ''time-bin'' experiments pioneered by Gisin's group. The use of a time-bin-like Mach-Zehnder interferometer in the CW pumping beam induces coherence between certain two-photon amplitudes, while the CW nature of the experiment prevents the elimination of remaining incoherent ones. The experimental results highlight the role of pump coherence in two-photon interferometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-frequency transient radiation from a complicated-profile boundary

High-frequency transient radiation accompanying the escape of a relativistic charged particle from a medium with a stepwise boundary is considered. The application of the results of this analysis to estimating the radiation-formation length is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanodilatometry to measure length changes due to radiation damage in naturally aged Pu specimens

Radioactive materials are self-damaging, which over time, impacts many physical and mechanical properties. One well documented effect is a change in density due to swelling from the accumulated damage to the atomic structure and in the case of α-decay, helium in-growth. In some materials, void growth has been shown to develop, where after a period of incubation, the material swells at a rapid rate, with deleterious effects. A second contrasting effect occurs in Ga stabilized δ-Pu, which is thermodynamically unstable and can partially transform to α’-Pu, a phase 20% denser and thus will cause contraction. Such changes can be observed through several experimental techniques. A change in length, measured by dilatometry is perhaps the simplest to understand, and best characterization of bulk. This report describes the development and testing of a dilatometer capable of measuring length changes resulting from radiation damage in standard weapons grade plutonium over a reasonable time scale (~ 1 month) and the preliminary results of measurements on plutonium samples. The dilatometer has the ability to measure swelling in samples between 0-100°C, a temperature range of programmatic interest.

36 MATERIALS SCIENCE↗

Angular dispersion enhanced prebunch for seeding ultrashort and coherent EUV and soft X-ray free-electron laser in storage rings

Prebunching is an effective technique to reduce the radiation saturation length and to improve the longitudinal coherence and output stability in storage-ring-based free-electron lasers (FELs). A novel technique is introduced which uses angular dispersion to enhance the high-harmonic bunching with very small laser-enabled energy spread. This technique can effectively reduce the radiation saturation length without significantly reducing the peak power of the FEL. Numerical simulations reveal that this technique can be used for the generation of 100 MW scale level, fully temporal coherent femtosecond extreme-ultraviolet and soft X-ray radiation pulses through a 10 m-long undulator based on a diffraction-limited storage ring.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GRMHD PREDICTION OF CORONAL VARIABILITY IN ACCRETING BLACK HOLES

On the basis of data from an energy-conserving three-dimensional general relativistic MHD simulation, we predict the statistical character of variability in the coronal luminosity from accreting black holes. When the inner boundary of the corona is defined to be the electron scattering photosphere, its location depends only on the mass accretion rate in Eddington units m-dot. Nearly independent of viewing angle and m-dot, the power spectrum over the range of frequencies from approximately the orbital frequency at the ISCO to {approx}100 times lower is well approximated by a power law with index -2, crudely consistent with the observed power spectra of hard X-ray fluctuations in active galactic nuclei and the hard states of Galactic black hole binaries. The underlying physical driver for variability in the light curve is variations in the accretion rate caused by the chaotic character of MHD turbulence, but the power spectrum of the coronal light output is significantly steeper. Part of this contrast is due to the fact that the mass accretion rate can be significantly modulated by radial epicyclic motions that do not result in dissipation, and therefore do not drive luminosity fluctuations. The other part of this contrast is due to the inward decrease of the characteristic inflow time, which leads to decreasing radial coherence length with increasing fluctuation frequency.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-dimensional radiation and scattering at short wave length

In the present investigation of radiation and scattering by objects when the wavelengths are much smaller than the characteristic dimensions of the radiator or scatterer, the boundary-element method is used to obtain computational accuracy and efficiency. The approach employed for wavelengths less than 5 percent of object characteristic dimensions involves cubic elements, approximate polynomial and asymptotic evaluations of the fundamental solution, and a tailoring of the order of the Gaussian quadrature according to the local demands dictated by the distance between sending and receiving points. The method addresses the propagation of low-frequency sound over large terrain features.

Yoon, W. S.↗

Influence of radiation absorption by microparticles on the flame velocity and combustion regimes

Thermal radiation from hot combustion products has virtually no effect on the flame propagation in a gas medium. We consider a different situation when even a small concentration of microparticles suspended in a gas absorbs the thermal radiation and heats the gas mixture ahead of the combustion wave front by transferring it to the gas. The mixture heating ahead of the flame front can lead either to a moderate increase in the combustion wave velocity for a fast flame or to its significant increase for a slow flame, depending on the gas mixture reactivity and the normal laminar flame velocity. For a slow flame, the heat transfer by radiation from the combustion products can become the dominant mechanism compared to the ordinary molecular thermal conduction that determines the combustion wave structure and velocity. The radiative heating for a spatially nonuniform distribution of particles ahead of the flame front is shown to give rise to a temperature gradient that, in turn, can lead to the ignition of different combustion regimes, depending on the radiation absorption length. In accordance with the Zeldovich gradient mechanism, both deflagration and detonation regimes can be formed in this case. A hydrogen–oxygen flame is used as an example to illustrate the ignition of different combustion wave propagation regimes, depending on the radiation absorption length.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗