Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Preliminary benchmarks and analysis of boundary conditions in a trenched microstructured silicon radiation detector

Microstructured neutron detectors have the benefit of enhanced neutron detection efficiency as compared to planar devices, achieved by etching 6 LiF-filled trenches on the top surface of a silicon PIN diode. This sensor geometry results in a complex electric field distribution and depletion characteristics within the diode under reverse bias. For the first time on record, the effects of a fixed oxide charge on the microstructured device depletion characteristics and mobile carrier transport is investigated. Prototype detectors were fabricated with non-conformal surface doping. Capacitance voltage and current voltage measurements were performed for these prototypes and compared with COMSOL Multiphysics simulations. A spectral response from an 241Am alpha particle source was acquired and analyzed. It was found that monoenergetic alpha particles produce three prominent peaks in the pulse height spectrum output by the device. The peaks were confirmed by simulations to correlate with dead layers and incident trajectories into the microstructure. It was also found that significant differences in pulse rise time result, corresponding with events arriving in a low-field region in the fins and a high-field region in the bulk. Geant4 was utilized for radiation transport, interaction modeling, and benchmarking the spectral data. The results of this simulation work provide confidence in the ability to attain and benchmark electrical characteristics and spectral data for semiconductor radiation detectors employing complex microstructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗

Simulations of Silicon Radiation Detectors for High Energy Physics Experiments

Silicon radiation detectors are an integral component of current and planned collider experiments in high energy physics. Simulations of these detectors are essential for deciding operational configurations, for performing precise data analysis, and for developing future detectors. In this white paper, we briefly review the existing tools and discuss challenges for the future that will require research and development to be able to cope with the foreseen extreme radiation environments of the High Luminosity runs of the Large Hadron Collider and future hadron colliders like FCC-hh and SPPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the Stability of Edge-Passivated CZTS Radiation Detectors

CdZnTeSe (CZTS) is a next gen replacement room temperature radiation detector that solves common issues with modern CZT detectors. • Surface states can trap radiation induced carriers and can act as leakage current pathways requiring detectors to passivated for optimal performance. • In this work, we seek to identify the best passivation technique for CZTS detectors.

KLEPPINGER, JOSHUA↗

Deployment of Diamond-Based Radiation Detector for Very High Dose Rate Measurements - 17042

The diamond-based radiation detector system has been developed at the University of Bristol to measure radiation within nuclear facilities known to exhibit high dose rates. The challenge at Sellafield site in the UK, described herein also applies to many other nuclear operators worldwide, making the transfer of diamond detector technology to other applications feasible. Development of an operator-friendly system, extensive detector testing and controlled calibrations have led to several successful deployments of the device at Sellafield site, providing them with valuable data about the radiological contamination within their highly active plants. Designed for measurements of intense radiation fields, this new tool for characterisation of radiologically hazardous environments is a game-changer, improving the availability and quality of dose rate data used in safety case justifications. Compared with conventional technology diamond detectors are radiation tolerant, miniature, and can measure an extraordinary range of dose rates. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple classical model for Fano statistics in radiation detectors

A simple classical model that captures the essential statistics of energy partitioning processes involved in the creation of information carriers (ICs) in radiation detectors is presented. The model pictures IC formation from a fixed amount of deposited energy in terms of the statistically analogous process of successively sampling water from a large, finite-volume container (“bathtub”) with a small dipping implement (“shot glass”). The model exhibits sub-Poisson variance in the distribution of the number of ICs generated (the “Fano e_ect”). Elementary statistical analysis of the model clarifies the role of energy conservation in producing the Fano e_ect and yields Fano’s prescription for relating the IC number distribution to the mean and variance of the underlying IC energy distribution. The connection between the model and energy partitioning in semiconductor radiation detectors is illustrated, and the implications of this simple picture for guiding or constraining more detailed, “microscopic” physical models of detector material response to ionizing radiation are discussed.

Jordan, David V↗

Properties of native defects in InI for potential radiation detector application

Heavy-metal halide semiconductors have attracted much interest recently for their potential applications in radiation detection because the large atomic numbers (high Z) of their constituent elements enable efficient radiation absorption and their large band gaps allow room temperature operation. However, defect properties of these halides and their connection to carrier transport are little known. In this paper, we present first-principles calculations on native defects in InI, which is a promising material for applications in room temperature radiation detection. The important findings are: (1) anion and cation vacancies (Schottky defects) form the dominant low-energy defects that can pin the Fermi level close to midgap, leading to high resistivity that is required for a good radiation detector material; (2) the anion vacancy in InI induces a deep electron trap, which should reduce electron mobility-lifetime product in InI; (3) low diffusion barriers of vacancies could be responsible for the observed polarization phenomenon at room temperature

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research Update: Reactively sputtered nanometer-thin ZrN film as a diffusion barrier between Al and boron layers for radiation detector applications

In this paper, optimization of the process flow for PureB detectors is investigated. Diffusion barrier layers between a boron layer and the aluminum interconnect can be used to enhance the performance and visual appearance of radiation detectors. Few nanometers-thin Zirconium Nitride (ZrN) layer deposited by reactive sputtering in a mixture of Ar/N{sub 2}, is identified as a reliable diffusion barrier with better fabrication process compatibility than others. The barrier properties of this layer have been tested for different boron layers deposited at low and high temperatures with extensive optical microscopy analyses, electron beam induced current, SEM, and electrical measurements. This study demonstrated that spiking behavior of pure Al on Si can be prevented by the thin ZrN layer thus improving the performance of the radiation detectors fabricated using boron layer.

36 MATERIALS SCIENCE↗

Cesium lead bromide semiconductor radiation detectors: crystal growth, detector performance and polarization

Cesium lead bromide (CsPbBr 3 ) is an upcoming semiconductor radiation detector that has the potential to match the detection properties of cadmium zinc telluride (CZT) and thallium bromide (TlBr). In this paper, we report on CsPbBr 3 gamma detectors with an uncorrected energy resolution of 2% at 662 keV with photopeak-to-Compton ratios as high as 14.3 and hole mobility-lifetime products (μτ h ) as high as 1.7 × 10 –2 cm 2 V –1 . Furthermore, we demonstrate that the processes employed for material purification and crystal growth of high-performing devices are scalable, and large (up to 65 mm in diameter) ultrahigh purity CsPbBr 3 crystals have been successfully grown. Furthermore by using optimized growth conditions and detector fabrication processes, we were able to mitigate the polarization problem where it was revealed that the polarization process is highly dependent on the crystal quality and the electric field direction with respect to the orientation of the crystal.

30 DIRECT ENERGY CONVERSION↗

Development of a fast radiation detector based on barium fluoride scintillation crystal

Barium fluoride (BaF{sub 2}) is an inorganic scintillation material used for the detection of X/gamma radiation due to its relatively high density, equivalent atomic number, radiation hardness, and high luminescence. BaF{sub 2} has a potential capacity to be used in gamma ray timing experiments due to the prompt decay emission components. It is known that the light output from BaF{sub 2} has three decay components: two prompt of those at approximately 195 nm and 220 nm with a decay constant around 600-800 ps and a more intense, slow component at approximately 310 nm with a decay constant around 630 ns which hinders fast timing experiments. We report here the development of a fast radiation detector based on a BaF{sub 2} scintillation crystal employing a special optical filter device, a multiple reflection multi-path ultraviolet region short-wavelength pass light guides (MRMP-short pass filter) by using selective reflection technique, for which the intensity of the slow component is reduced to less than 1%. The methods used for this study provide a novel way to design radiation detector by utilizing scintillation crystal with several emission bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Transport Properties of CdMnTe Radiation Detectors

Growth, fabrication and characterization of indium-doped cadmium manganese telluride (CdMnTe) radiation detectors have been described. Alpha-particle spectroscopy measurements and time resolved current transient measurements have yielded an average charge collection efficiency approaching 100 %. Spatially resolved charge collection efficiency maps have been produced for a range of detector bias voltages. Inhomogeneities in the charge transport of the CdMnTe crystals have been associated with chains of tellurium inclusions within the detector bulk. Further, it has been shown that the role of tellurium inclusions in degrading charge collection is reduced with increasing values of bias voltage. The electron transit time was determined from time of flight measurements. From the dependence of drift velocity on applied electric field the electron mobility was found to be μ n = (718 ± 55) cm 2 /Vs at room temperature.

36 MATERIALS SCIENCE↗

Invited Review Article: Physics and Monte Carlo techniques as relevant to cryogenic, phonon, and ionization readout of Cryogenic Dark Matter Search radiation detectors

This review discusses detector physics and Monte Carlo techniques for cryogenic, radiation detectors that utilize combined phonon and ionization readout. A general review of cryogenic phonon and charge transport is provided along with specific details of the Cryogenic Dark Matter Search detector instrumentation. In particular, this review covers quasidiffusive phonon transport, which includes phonon focusing, anharmonic decay, and isotope scattering. The interaction of phonons in the detector surface is discussed along with the downconversion of phonons in superconducting films. The charge transport physics include a mass tensor which results from the crystal band structure and is modeled with a Herring-Vogt transformation. Charge scattering processes involve the creation of Neganov-Luke phonons. Transition-edge-sensor (TES) simulations include a full electric circuit description and all thermal processes including Joule heating, cooling to the substrate, and thermal diffusion within the TES, the latter of which is necessary to model normal-superconducting phase separation. Relevant numerical constants are provided for these physical processes in germanium, silicon, aluminum, and tungsten. Random number sampling methods including inverse cumulative distribution function (CDF) and rejection techniques are reviewed. To improve the efficiency of charge transport modeling, an additional second order inverse CDF method is developed here along with an efficient barycentric coordinate sampling method of electric fields. Results are provided in a manner that is convenient for use in Monte Carlo and references are provided for validation of these models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transport properties of p-CdTe/n-CdTe/n{sup +}-Si diode-type nuclear radiation detectors based on metalorganic vapor-phase epitaxy-grown epilayers

Charge transport properties of p-CdTe/n-CdTe/n{sup +}-Si diode-type nuclear radiation detectors, fabricated by growing p-and n-type CdTe epilayers on (211) n{sup +}-Si substrates using metalorganic vapor-phase epitaxy (MOVPE), were studied by analyzing current-voltage characteristics measured at various temperatures. The diode fabricated shows good rectification properties, however, both forward and reverse biased currents deviate from their ideal behavior. The forward current exhibits typical feature of multi-step tunneling at lower biases; however, becomes space charge limited type when the bias is increased. On the other hand, the reverse current exhibits thermally activated tunneling-type current. It was found that trapping centers at the p-CdTe/n-CdTe junction, which were formed due to the growth induced defects, determine the currents of this diode, and hence limit the performance of the nuclear radiation detectors developed.

36 MATERIALS SCIENCE↗