In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Transport Properties of CdMnTe Radiation Detectors

Growth, fabrication and characterization of indium-doped cadmium manganese telluride (CdMnTe) radiation detectors have been described. Alpha-particle spectroscopy measurements and time resolved current transient measurements have yielded an average charge collection efficiency approaching 100 %. Spatially resolved charge collection efficiency maps have been produced for a range of detector bias voltages. Inhomogeneities in the charge transport of the CdMnTe crystals have been associated with chains of tellurium inclusions within the detector bulk. Further, it has been shown that the role of tellurium inclusions in degrading charge collection is reduced with increasing values of bias voltage. The electron transit time was determined from time of flight measurements. From the dependence of drift velocity on applied electric field the electron mobility was found to be μ n = (718 ± 55) cm 2 /Vs at room temperature.

36 MATERIALS SCIENCE↗

Invited Review Article: Physics and Monte Carlo techniques as relevant to cryogenic, phonon, and ionization readout of Cryogenic Dark Matter Search radiation detectors

This review discusses detector physics and Monte Carlo techniques for cryogenic, radiation detectors that utilize combined phonon and ionization readout. A general review of cryogenic phonon and charge transport is provided along with specific details of the Cryogenic Dark Matter Search detector instrumentation. In particular, this review covers quasidiffusive phonon transport, which includes phonon focusing, anharmonic decay, and isotope scattering. The interaction of phonons in the detector surface is discussed along with the downconversion of phonons in superconducting films. The charge transport physics include a mass tensor which results from the crystal band structure and is modeled with a Herring-Vogt transformation. Charge scattering processes involve the creation of Neganov-Luke phonons. Transition-edge-sensor (TES) simulations include a full electric circuit description and all thermal processes including Joule heating, cooling to the substrate, and thermal diffusion within the TES, the latter of which is necessary to model normal-superconducting phase separation. Relevant numerical constants are provided for these physical processes in germanium, silicon, aluminum, and tungsten. Random number sampling methods including inverse cumulative distribution function (CDF) and rejection techniques are reviewed. To improve the efficiency of charge transport modeling, an additional second order inverse CDF method is developed here along with an efficient barycentric coordinate sampling method of electric fields. Results are provided in a manner that is convenient for use in Monte Carlo and references are provided for validation of these models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transport properties of p-CdTe/n-CdTe/n{sup +}-Si diode-type nuclear radiation detectors based on metalorganic vapor-phase epitaxy-grown epilayers

Charge transport properties of p-CdTe/n-CdTe/n{sup +}-Si diode-type nuclear radiation detectors, fabricated by growing p-and n-type CdTe epilayers on (211) n{sup +}-Si substrates using metalorganic vapor-phase epitaxy (MOVPE), were studied by analyzing current-voltage characteristics measured at various temperatures. The diode fabricated shows good rectification properties, however, both forward and reverse biased currents deviate from their ideal behavior. The forward current exhibits typical feature of multi-step tunneling at lower biases; however, becomes space charge limited type when the bias is increased. On the other hand, the reverse current exhibits thermally activated tunneling-type current. It was found that trapping centers at the p-CdTe/n-CdTe junction, which were formed due to the growth induced defects, determine the currents of this diode, and hence limit the performance of the nuclear radiation detectors developed.

36 MATERIALS SCIENCE↗

Advanced Radiation Detectors and Detector Systems Research

Real‐time awareness of space radiation is critical for missions beyond LEO. Missions to the Moon, Mars, Near‐Earth‐Objects (NEOs), inner and outer planets, as well as other destinations in space, will require embedded instrumentation to provide feedback for “smart”, adaptive control systems. Precision instrumentation will also be needed to provide improved data for space radiation modeling and space weather forecasting and awareness. Compact instrumentation on small platforms such as CubeSats and other small space‐faring vehicles will provide a better understanding of the space radiation environment by supplying data from multiple locations in space where information is yet unknown. Compact integrable solid‐state detectors with low noise and high tolerance of operation in a radiation environment are enabled by the application of Wide Band Gap semiconductors as radiation detectors. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies that enable improved instruments for space science missions. A variety of radiation detectors are under development, such as silicon carbide semiconductor detectors, for applications to space science, lunar prospecting, and fission power systems.

Field and particle detectors↗

Neural network methods for radiation detectors and imaging

Recent advances in image data proccesing through deep learning allow for new optimization and performance-enhancement schemes for radiation detectors and imaging hardware. This enables radiation experiments, which includes photon sciences in synchrotron and X-ray free electron lasers as a subclass, through data-endowed artificial intelligence. We give an overview of data generation at photon sources, deep learning-based methods for image processing tasks, and hardware solutions for deep learning acceleration. Most existing deep learning approaches are trained offline, typically using large amounts of computational resources. However, once trained, DNNs can achieve fast inference speeds and can be deployed to edge devices. A new trend is edge computing with less energy consumption (hundreds of watts or less) and real-time analysis potential. While popularly used for edge computing, electronic-based hardware accelerators ranging from general purpose processors such as central processing units (CPUs) to application-specific integrated circuits (ASICs) are constantly reaching performance limits in latency, energy consumption, and other physical constraints. These limits give rise to next-generation analog neuromorhpic hardware platforms, such as optical neural networks (ONNs), for high parallel, low latency, and low energy computing to boost deep learning acceleration (LA-UR-23-32395).

edge computing↗

Prototype Radiation Detector Positioning System For The Automated Nondestructive Assay Of Uf6 Cylinders

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility’s entire cylinder inventory. These measurements are time-consuming, expensive, and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of efficiency and assay accuracy. This paper describes an approach denoted the Integrated Cylinder Verification Station (ICVS) that supports 100% cylinder verification, provides volume-averaged cylinder enrichment assay, and reduces inspector manpower needs. To allow field measurements to be collected to validate data collection algorithms, a prototype radiation detector positioning system was constructed. The system was designed to accurately position an array of radiation detectors along the length of a cylinder to measure UF6 enrichment. A number of alternative radiation shields for the detectors were included with the system. A collimated gamma-ray spectrometer module that allows translation of the detectors in the surrounding shielding to adjust the field of view, and a collimating plug in the end to further reduce the low-energy field of view, were also developed. Proof-of-principle measurements of neutron and high-energy gamma-ray signatures, using moderated neutron detectors and large-volume spectrometers in a fixed-geometry, portal-like configuration, supported an early assessment of the viability of the concept. The system has been used successfully on two testing campaigns at an AREVA fuel fabrication plant to scan over 30 product cylinders. This paper will describe the overall design of the detector positioning system and provide an overview of the Integrated Cylinder Verification Station (ICVS) approach.

assay↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma Panel Based Radiation Detectors

The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels (PDPs). It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in PDPs, it uses non-reactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (< 50 m RMS) and low cost. In this paper we report here on prototype PPS experimental results in detecting betas, protons and cosmic muons, and we extrapolate on the PPS potential for applications including detection of alphas, heavy-ions at low to medium energy, thermal neutrons and X-rays.

Friedman, Dr. Peter S.↗

TH-CD-201-12: Preliminary Evaluation of Organic Field Effect Transistors as Radiation Detectors

Purpose: To fabricate organic field effect transistors (OFETs) and evaluate their performance before and after exposure to ionizing radiation. To determine if OFETs have potential to function as radiation dosimeters. Methods: OFETs were fabricated on both Si/SiO{sub 2} wafers and flexible polymer substrates using standard processing techniques. Pentacene was used as the organic semiconductor material and the devices were fabricated in a bottom gate configuration. Devices were irradiated using an orthovoltage treatment unit (120 kVp x-rays). Threshold voltage values were measured with the devices in saturation mode and quantified as a function of cumulative dose. Current-voltage characteristics of the devices were measured using a Keithley 2614 SourceMeter SMU Instrument. The devices were connected to the reader but unpowered during irradiations. Results: Devices fabricated on Si/SiO2 wafers demonstrated excellent linearity (R{sup 2} > 0.997) with threshold voltages that ranged between 15 and 36 V. Devices fabricated on a flexible polymer substrate had substantially smaller threshold voltages (∼ 4 – 8 V) and slightly worse linearity (R{sup 2} > 0.98). The devices demonstrated excellent stability in I–V characteristics over a large number (>2000) cycles. Conclusion: OFETs have demonstrated excellent potential in radiation dosimetry applications. A key advantage of these devices is their composition, which can be substantially more tissue-equivalent at low photon energies relative to many other types of radiation detector. In addition, fabrication of organic electronics can employ techniques that are faster, simpler and cheaper than conventional silicon-based devices. These results support further development of organic electronic devices for radiation detection purposes. Funding Support, Disclosures, and Conflict of Interest: This work was funded by the Natural Sciences and Engineering Research Council of Canada.

60 APPLIED LIFE SCIENCES↗

Materials Modeling for High-Performance Radiation Detectors

Limitations in the performance of room-temperature gamma radiation detectors are intimately related to the properties of the materials used to fabricate them. In particular, atomic-scale defects in the materials that can depend on crystal growth or device processing conditions often ultimately determine the performance of a given detector. Understanding the origins and consequences of these various defects is essential to optimizing the materials and achieving maximum device performance (e.g., energy resolution and sensitivity). This project aims to enable rational materials design for select high-payoff challenges in radiation detection materials by using state-of-the-art modeling techniques bridging multiple resolutions. Three specific high-impact challenges are addressed: (i) design and optimization of electrical contact stacks for thallium bromide (TlBr) detectors to stabilize temporal response at room-temperature; (ii) design of host glass for large-volume, low-cost, high-performance glass scintillators; and (iii) determination of the electrical impacts of dislocation networks in cadmium zinc telluride (CZT) that limit its performance and usable single-crystal volume.

36 MATERIALS SCIENCE↗

Calibration of the active radiation detector for Spacelab-One

The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

Source record↗

Processing circuitry for single channel radiation detector

Processing circuitry is provided for a high voltage operated radiation detector. An event detector utilizes a comparator configured to produce an event signal based on a leading edge threshold value. A preferred event detector does not produce another event signal until a trailing edge threshold value is satisfied. The event signal can be utilized for counting the number of particle hits and also for controlling data collection operation for a peak detect circuit and timer. The leading edge threshold value is programmable such that it can be reprogrammed by a remote computer. A digital high voltage control is preferably operable to monitor and adjust high voltage for the detector.

Holland, Samuel D.↗

Control of electric field in CdZnTe radiation detectors by above-bandgap light

We have studied the possibility of above bandgap light induced depolarization of CdZnTe planar radiation detector operating under high flux of X-rays by Pockels effect measurements. In this contribution, we show a similar influence of X-rays at 80 kVp and LED with a wavelength of 910 nm irradiating the cathode on polarization of the detector due to an accumulation of a positive space charge of trapped photo-generated holes. We have observed the depolarization of the detector under simultaneous cathode-site illumination with excitation LED at 910 nm and depolarization above bandgap LED at 640 nm caused by trapping of drifting photo-generated electrons. Although the detector current is quite high during this depolarization, we have observed that it decreases relatively fast to its initial value after switching off the depolarizing light. In order to get detailed information about physical processes present during polarization and depolarization and, moreover, about associated deep levels, we have performed the Pockels effect infrared spectral scanning measurements of the detector without illumination and under illumination in polarized and optically depolarized states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultraviolet radiation detector and dosimeter

An ultraviolet radiation dosimeter apparatus for measuring an individual's ultraviolet radiation exposure from incoming ultraviolet rays, including an ultraviolet radiation dosimeter body; an ultraviolet filter in the ultraviolet radiation dosimeter body; a detector semiconductor substrate in the ultraviolet radiation dosimeter body connected to the ultraviolet filter for detecting the incoming ultraviolet rays and producing a signal, the semiconductor substrate made of ZnSe(Te), and a chip in the ultraviolet radiation dosimeter body for receiving the signal and measuring the individual's ultraviolet radiation exposure from the incoming ultraviolet rays.

Smith, Craig F.↗