Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality Attributes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Landsat change detection can aid in water quality monitoring

Comparison between Landsat-1 and -2 imagery of Arkansas provided evidence of significant land use changes during the 1972-75 time period. Analysis of Arkansas historical water quality information has shown conclusively that whereas point source pollution generally can be detected by use of water quality data collected by state and federal agencies, sampling methodologies for nonpoint source contamination attributable to surface runoff are totally inadequate. The expensive undertaking of monitoring all nonpoint sources for numerous watersheds can be lessened by implementing Landsat change detection analyses.

Macdonald, H. C.↗

Fabrication of LARC 160/NR150B2 hybrid matrix polyimide composites

Graphite-polyimide composite materials exhibit high performance, low weight, and good thermal-oxidative stability, making them promising candidates for Space Shuttle applications. However, no single material is excellent in all respects: processibility, thermal-oxidative stability, toughness, and mechanical properties. This paper describes the development of hybrid matrix composite laminates that combine the attributes of two polyimide resins, NR150B2 and LARC 160, while avoiding their drawbacks. High quality laminates were fabricated from each resin system, and hybrid laminates were successfully co-cured, evaluated, and optimized.

Bergren, O. D.↗

A quasioptical resonant-tunneling-diode oscillator operating above 200 GHz

We have fabricated and characterized a quasioptically stabilized resonant-tunneling-diode (RTD) oscillator having attractive performance characteristics for application as a radiometric local oscillator. The fundamental frequency of the oscillator is tunable from about 200 to 215 GHz, the instantaneous linewidth is between 10 and 20 kHz, and the output power across the tuning band is about 50 micro-W. The narrow linewidth and fine tuning of the frequency are made possible by a scanning semiconfocal open cavity which acts as the high-Q resonator for the oscillator. The cavity is compact, portable, and insensitive to vibration and temperature variation. The total dc power consumption (RTD plus bias supply) is only 10 mW. The present oscillator provides the highest power obtained to date from an RTD above 200 GHz. We attribute this partly to the use of the quasioptical resonator, but primarily to the quality of the RTD. It is fabricated from the In(0.53)Ga(0.47)As/AlAs materials system, which historically has yielded the best overall resonant-tunneling characteristics of any material system. The RTD active area is 4 sq microns, and the room-temperature peak current density and peak-to-valley current ratio are 2.5x10(exp 5) A cm(exp -2) and 9, respectively. The RTD is mounted in a WR-3 standard-height rectangular waveguide and is contacted across the waveguide by a fine wire that protrudes through a via hole in a Si3N4 'honeycomb' overlayer. We estimate that the theoretical maximum frequency of oscillation of this RTD is approximately 1.1 THz, and that scaled-down versions of the same quasioptical oscillator design should operate in a fundamental mode up to frequencies of at least 500 GHz.

Brown, E. R.↗

A Fast and Sensitive New Satellite SO2 Retrieval Algorithm based on Principal Component Analysis: Application to the Ozone Monitoring Instrument

We describe a new algorithm to retrieve SO2 from satellite-measured hyperspectral radiances. We employ the principal component analysis technique in regions with no significant SO2 to capture radiance variability caused by both physical processes (e.g., Rayleigh and Raman scattering and ozone absorption) and measurement artifacts. We use the resulting principal components and SO2 Jacobians calculated with a radiative transfer model to directly estimate SO2 vertical column density in one step. Application to the Ozone Monitoring Instrument (OMI) radiance spectra in 310.5-340 nm demonstrates that this approach can greatly reduce biases in the operational OMI product and decrease the noise by a factor of 2, providing greater sensitivity to anthropogenic emissions. The new algorithm is fast, eliminates the need for instrument-specific radiance correction schemes, and can be easily adapted to other sensors. These attributes make it a promising technique for producing longterm, consistent SO2 records for air quality and climate research.

Principal component analysis↗

Interplay Between Thin Film Ferroelectric Composition, Microstructure and Microwave Phase Shifter Performance

One of the keys to successfully incorporating ferroelectric films into Ku-band (12 to 18 GHz) phase shifters is to establish the composition, microstructure, and thickness required to meet the tuning needs, and tailor the film properties to meet these needs. Optimal performance is obtained when the film composition and device design are such that the device performance is limited by odd mode dielectric losses, and these losses are minimized as much as possible while still maintaining adequate tunability. The parameters required to maintain device performance will vary slightly depending on composition, but we can conclude that the best tuning-to-loss figures of merit (K-factor) are obtained when there is minimal variation between the in-plane and out-of-plane lattice parameters, and the full-width half maximum values of the BSTO (002) peaks are less than approximately 0.04 deg. We have observed that for phase shifters in which the ferroelectric crystalline quality and thickness are almost identical, higher losses are observed in films with higher BaISr ratios. The best performance was observed in phase shifters with Ba:Sr = 30:70. The superiority of this composition was attributed to several interacting factors: the B a: Sr ratio was such that the Curie temperature (180 K) was far removed from room temperature, the crystalline quality of the film was excellent, and there was virtually no difference between the inplane and out-of-plane lattice parameters of the film.

Mueller, Carl H.↗

Retransmission of water resources data using the ERTS-1 data collection system

The Water Survey of Canada operates a network of approximately 2400 gauging stations at which water level data are collected. Nine DCPs were installed in isolated areas of northern and western Canada. It was felt that DCPs in these locations would be exposed to climatic conditions severe enough to provide a check on system reliability. Water level data are transmitted from all sites and, also, some of the DCPs are used to transmit ice break-up, water velocity, precipitation, air temperature, water stage recorder clock operation or DCP battery voltage. Consideration is being given to transmitting other parameters that would be of value in flood or flow forecasting. Results of the project have been excellent. There has been no data loss that can be attributed to failure of a DCP although data were lost because of sensor malfunctions. The quality of data collected compares favourably with that of the hard record obtained at the remote sites. Costs of using the ERTS Data Collection System are reasonable.

Halliday, R. A.↗

NTP comparison process

The systems engineering process for the concept definition phase of the program involves requirements definition, system definition, and consistent concept definition. The requirements definition process involves obtaining a complete understanding of the system requirements based on customer needs, mission scenarios, and nuclear thermal propulsion (NTP) operating characteristics. A system functional analysis is performed to provide a comprehensive traceability and verification of top-level requirements down to detailed system specifications and provides significant insight into the measures of system effectiveness to be utilized in system evaluation. The second key element in the process is the definition of system concepts to meet the requirements. This part of the process involves engine system and reactor contractor teams to develop alternative NTP system concepts that can be evaluated against specific attributes, as well as a reference configuration against which to compare system benefits and merits. Quality function deployment (QFD), as an excellent tool within Total Quality Management (TQM) techniques, can provide the required structure and provide a link to the voice of the customer in establishing critical system qualities and their relationships. The third element of the process is the consistent performance comparison. The comparison process involves validating developed concept data and quantifying system merits through analysis, computer modeling, simulation, and rapid prototyping of the proposed high risk NTP subsystems. The maximum amount possible of quantitative data will be developed and/or validated to be utilized in the QFD evaluation matrix. If upon evaluation of a new concept or its associated subsystems determine to have substantial merit, those features will be incorporated into the reference configuration for subsequent system definition and comparison efforts.

Corban, Robert↗

The effects of specimen scale on the compression strength of composite materials

This paper presents a number of observations on the effect of specimen scale on the compression response of composite materials. Work on this topic was motivated by observations that thick-walled, unstiffened carbon reinforced cylinders subjected to hydrostatic pressure were not reaching inplane laminate stress levels at failure expected from coupon level properties, while similar cylinders reinforced with fiberglass were. Results from a study on coupon strength of (0/0/90) laminates, reinforced with AS4 carbon fiber and S2 glass fiber, are presented and show that compression strength is not a function of material or specimen thickness for materials that have the same laminate quality (autoclave cured quality). Actual laminate compression strength was observed to decrease with increasing thickness, but this is attributed to fixture restraint effects on coupon response. The hypothesis drawn from the coupon level results is further supported by results from a compression test on a thick carbon reinforced coupon in a fixture with reduced influence on specimen response and from a hydrostatic test on an unstiffened carbon reinforced cylinder subjected to hydrostatic pressure with end closures designed to minimize their effect on cylinder response.

Camponeschi, Eugene Thomas, Jr.↗

Trends in the Vertical Distribution of Ozone: A Comparison of Two Analyses of Ozonesonde Data

We present the results of two independent analyses of ozonesonde measurements of the vertical profile of ozone. For most of the ozonesonde stations we use data that were recently reprocessed and reevaluated to improve their quality and internal consistency. The two analyses give similar results for trends in ozone. We attribute differences in results primarily to differences in data selection criteria and in utilization of data correction factors, rather than in statistical trend models. We find significant decreases in stratospheric ozone at all stations in middle and high latitudes of the northern hemisphere from 1970 to 1996, with the largest decreases located between 12 and 21 km, and trends of -3 to -10 %/decade near 17 km. The decreases are largest at the Canadian and the most northerly Japanese station, and are smallest at the European stations, and at Wallops Island, U.S.A. The mean mid-latitude trend is largest, -7 %/decade, from 12 to 17.5 km for 1970-96. For 1980-96, the decrease is more negative by 1-2 %/decade, with a maximum trend of -9 %/decade in the lowermost stratosphere. The trends vary seasonally from about 12 to 17.5 km, with largest ozone decreases in winter and spring. Trends in tropospheric ozone are highly variable and depend on region. There are decreases or zero trends at the Canadian stations for 1970-96, and decreases of -2 to -8 %/decade for the mid-troposphere for 1980-96; the three European stations show increases for 1970-96, but trends are close to zero for two stations for 1980-96 and positive for one; there are increases in ozone for the three Japanese stations for 1970-96, but trends are either positive or zero for 1980-96; the U.S. stations show zero or slightly negative trends in tropospheric ozone after 1980. It is not possible to define reliably a mean tropospheric ozone trend for northern mid-latitudes, given the small number of stations and the large variability in trends. The integrated column trends derived from the sonde data are consistent with trends derived from both surface based and satellite measurements of the ozone column.

Loogan, J. A.↗

Towards a Combined Low-Earth Orbit Lightning Climatology: Current Work and Assessing South Atlantic Anomaly Influence

This presentation discusses the current status and ongoing work towards a low-Earth orbit (LEO) lightning climatological product that includes both Lightning Imaging Sensors (LIS) and the Optical Transient Detector (OTD). The project builds upon the work by Cecil et al. (2014) to include the LIS on the International Space Station (ISS), featuring additional inter-instrumental comparisons to more accurately depict the unique capabilities of each instrument. A closer examination of the interference from the South Atlantic Anomaly (SAA) was also conducted on all three LEO sensors. The SAA is a region of the magnetosphere roughly spanning the south-central Atlantic wherein the inner Van Allen radiation belts are closer to Earth than anywhere else, subjecting spacecraft in LEO to significantly higher radiation flux levels. This radiation can produce interference with the LIS and OTD instruments, manifesting as non-lightning luminous events. While these events can be identified easily enough, they can occur in such quantities that they overwhelm the sensors’ processors and effectively ‘blind’ them. This is called the First-In First-Out (FIFO) buffer overflow, and this blinded time reduced the instruments’ view-time as a result. The FIFO overflow and view-time can reliably be used to track the SAA interference (Clark et al. 2024), which allows for the lightning counts attributable to the SAA to be assessed. The impact that the SAA had on the quality of observations from the LEO lightning instrumentation and the significance for the resulting climatological products was investigated. Substantial areas of interference were identified for all three instruments using the view-time and quality flags, each with a unique shape and temporal evolution. The temporal evolution and general region affected are of particular importance when constructing a climatological product, as there are notable reductions to view-time over prolonged periods across a lightning-rich region. However, a temporal element also makes isolating the subsequent impact on the lightning signal significantly more challenging. Lightning counts in this region are highly seasonal and exhibit inter-annual variability, which is compounded by the nature of LEO observations. This study includes preliminary analysis of the impact that the SAA has on the lightning counts given the notable impact shown in the metadata.

Austin G Clark↗

Quality comparison of hydroponic tomatoes (Lycopersicon esculentum) ripened on and off vine

There is a general belief that the quality of tomatoes ripened on vine is better than tomatoes ripened off the vine, influencing among other parameters, the price of this commodity. We compared the quality of hydroponic tomatoes ripened on and off vine by chemical, physical, and sensory evaluation to find what attributes are affected and to what extent. Lycopene, beta-carotene, total and soluble solids, moisture content, ascorbic acid, acidity, pH, texture, and color were analyzed. Tomatoes ripened on vine had significantly more lycopene, beta-carotene, soluble and total solids, higher a* and lower L*, and were firmer. However, a 100-judge panel rated only the color and overall liking of the vine-ripened tomatoes as more intense than the fruit ripened off vine. Therefore, the chemical and physical differences were mostly not large enough to influence the panelist's perception. The characterization of tomatoes ripened on and off vine may help to guide post-harvest handling and treatment and to improve the quality of tomatoes ripened off vine.

Non-NASA Center↗

Aerosol Source Attributions and Source-Receptor Relationships Across the Northern Hemisphere

Emissions and long-range transport of air pollution pose major concerns on air quality and climate change. To better assess the impact of intercontinental transport of air pollution on regional and global air quality, ecosystems, and near-term climate change, the UN Task Force on Hemispheric Transport of Air Pollution (HTAP) is organizing a phase II activity (HTAP2) that includes global and regional model experiments and data analysis, focusing on ozone and aerosols. This study presents the initial results of HTAP2 global aerosol modeling experiments. We will (a) evaluate the model results with surface and aircraft measurements, (b) examine the relative contributions of regional emission and extra-regional source on surface PM concentrations and column aerosol optical depth (AOD) over several NH pollution and dust source regions and the Arctic, and (c) quantify the source-receptor relationships in the pollution regions that reflect the sensitivity of regional aerosol amount to the regional and extra-regional emission reductions.

HTAP2↗

Experiences in improving the state of the practice in verification and validation of knowledge-based systems

Knowledge-based systems (KBS's) are in general use in a wide variety of domains, both commercial and government. As reliance on these types of systems grows, the need to assess their quality and validity reaches critical importance. As with any software, the reliability of a KBS can be directly attributed to the application of disciplined programming and testing practices throughout the development life-cycle. However, there are some essential differences between conventional software and KBSs, both in construction and use. The identification of these differences affect the verification and validation (V&V) process and the development of techniques to handle them. The recognition of these differences is the basis of considerable on-going research in this field. For the past three years IBM (Federal Systems Company - Houston) and the Software Technology Branch (STB) of NASA/Johnson Space Center have been working to improve the 'state of the practice' in V&V of Knowledge-based systems. This work was motivated by the need to maintain NASA's ability to produce high quality software while taking advantage of new KBS technology. To date, the primary accomplishment has been the development and teaching of a four-day workshop on KBS V&V. With the hope of improving the impact of these workshops, we also worked directly with NASA KBS projects to employ concepts taught in the workshop. This paper describes two projects that were part of this effort. In addition to describing each project, this paper describes problems encountered and solutions proposed in each case, with particular emphasis on implications for transferring KBS V&V technology beyond the NASA domain.

Culbert, Chris↗

Polarization photometer to measure bidirectional reflectance factor R(55 deg, 0 deg, 55 deg, 180 deg) of leaves

A polarization photometer has been developed for rapidly determining the bidirectional, polarized, and diffuse light-scattering properties of individual leavs illuminated and measured 'in vivo' at an angle of 55 deg (approximately Brewster's angle) in six wavelength bands in the visible and near-IR wavelength regions. The optical performance and data quality of the system are evaluated to estimate the magnitude of the variation in the data attributable to the instrument system and to measurement procedures. The potential to discriminate between three species of oak is demonstrated using data acquired by the polarization photometer. The instrument is being used to increase understanding of the radiation transfer process in plant canopies and specifically to determine how agronomic information of the physical and chemical processes in leaves, plants, and plant canopies is expressed in these light-scattering properties.

Vanderbilt, V. C.↗

Choice of image attribute for automated radargrammetry

This paper discusses SAR imaging with emphasis on radar backscatter properties. In studying how planetary surfaces modulate the radar cross-section, it is determined that both the amount of and variation in backscattered microwave energy provide the necessary cues (i.e., object shading and boundary information) for stereointerpretation. While past research into automated reconstruction of topography from radar stereopairs has concentrated on the use of shading, it is shown that boundary information may also be used successfully. How these attributes can be potentially misleading are discussed. This work suggests a process for generating high-quality topography maps from SAR imagery.

Matarese, Joseph R.↗

Next Generation Aura-OMI SO2 Retrieval Algorithm: Introduction and Implementation Status

We introduce our next generation algorithm to retrieve SO2 using radiance measurements from the Aura Ozone Monitoring Instrument (OMI). We employ a principal component analysis technique to analyze OMI radiance spectral in 310.5-340 nm acquired over regions with no significant SO2. The resulting principal components (PCs) capture radiance variability caused by both physical processes (e.g., Rayleigh and Raman scattering, and ozone absorption) and measurement artifacts, enabling us to account for these various interferences in SO2 retrievals. By fitting these PCs along with SO2 Jacobians calculated with a radiative transfer model to OMI-measured radiance spectra, we directly estimate SO2 vertical column density in one step. As compared with the previous generation operational OMSO2 PBL (Planetary Boundary Layer) SO2 product, our new algorithm greatly reduces unphysical biases and decreases the noise by a factor of two, providing greater sensitivity to anthropogenic emissions. The new algorithm is fast, eliminates the need for instrument-specific radiance correction schemes, and can be easily adapted to other sensors. These attributes make it a promising technique for producing long-term, consistent SO2 records for air quality and climate research. We have operationally implemented this new algorithm on OMI SIPS for producing the new generation standard OMI SO2 products.

Sulfur dioxide↗

Modelling Freshwater Resources at the Global Scale: Challenges and Prospects

Quantification of spatially and temporally resolved water flows and water storage variations for all land areas of the globe is required to assess water resources, water scarcity and flood hazards, and to understand the Earth system. This quantification is done with the help of global hydrological models (GHMs). What are the challenges and prospects in the development and application of GHMs? Seven important challenges are presented. (1) Data scarcity makes quantification of human water use difficult even though significant progress has been achieved in the last decade. (2) Uncertainty of meteorological input data strongly affects model outputs. (3) The reaction of vegetation to changing climate and CO2 concentrations is uncertain and not taken into account in most GHMs that serve to estimate climate change impacts. (4) Reasons for discrepant responses of GHMs to changing climate have yet to be identified. (5) More accurate estimates of monthly time series of water availability and use are needed to provide good indicators of water scarcity. (6) Integration of gradient-based groundwater modelling into GHMs is necessary for a better simulation of groundwater-surface water interactions and capillary rise. (7) Detection and attribution of human interference with freshwater systems by using GHMs are constrained by data of insufficient quality but also GHM uncertainty itself. Regarding prospects for progress, we propose to decrease the uncertainty of GHM output by making better use of in situ and remotely sensed observations of output variables such as river discharge or total water storage variations by multi-criteria validation, calibration or data assimilation. Finally, we present an initiative that works towards the vision of hyper resolution global hydrological modelling where GHM outputs would be provided at a 1-km resolution with reasonable accuracy.

Global hydrological model↗

An Update on Ozone Profile Trends for the Period 2000 to 2016

Ozone profile trends over the period 2000 to 2016 from several merged satellite ozone data sets and from ground-based data measured by four techniques at stations of the Network for the Detection of Atmospheric Composition Change indicate significant ozone increases in the upper stratosphere, between 35 and 48 kilometers altitude (5 and 1 hectopascals). Near 2 hectopascals (42 kilometers), ozone has been increasing by about 1.5 percent per decade in the tropics (20 degrees S to 20 degrees N), and by 2 to 2.5 percent per decade in the 35 to 60 degree latitude bands of both hemispheres. At levels below 35 kilometers (5 hectopascals), 2000 to 2016 ozone trends are smaller and not statistically significant. The observed trend profiles are consistent with expectations from chemistry climate model simulations. This study confirms positive trends of upper stratospheric ozone already reported, e.g., in the WMO/UNEP (World Meteorological Organization/United Nations Environmental Programme) Ozone Assessment 2014 or by Harris et al. (2015). Compared to those studies, three to four additional years of observations, updated and improved data sets with reduced drift, and the fact that nearly all individual data sets indicate ozone increase in the upper stratosphere, all give enhanced confidence. Uncertainties have been reduced, for example for the trend near 2 hectopascals in the 35 to 60 degree latitude bands from about plus or minus 5 percent (2 sigma) in Harris et al. (2015) to less than plus or minus 2 percent (2 sigma). Nevertheless, a thorough analysis of possible drifts and differences between various data sources is still required, as is a detailed attribution of the observed increases to declining ozone-depleting substances and to stratospheric cooling. Ongoing quality observations from multiple independent platforms are key for verifying that recovery of the ozone layer continues as expected.

chemistry climate model simulations↗