Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High voltage pulse generator

Generator has an improved circuit for generating a controllable, high voltage spark having a constant known energy output. It can be used for testing the flash and ignition characteristics of nonmetallic materials in a controlled gas environment.

Pippen, D. L.↗

Hot-Air-Pulse Generator

Mixer blades interrupt airflow for rapid testing of insulating materials. Device for producing periodic blasts of heated air used for rapid testing of flexible insulating materials. Used to compare materials and to select candidates for more detailed testing in wind tunnels.

Ammerman, M. C.↗

The pulsed air gust generator

Pulsed air gust generator for sinusoidal streamwise perturbation of wind tunnel test stream, describing upstream blowing air jet array, flow calibration and mathematical model

Bicknell, J.↗

An ultrasonic plethysmograph for space flight applications

The development of an ultrasonic plethysmograph based on the transit time measurement principle is reported, which meets the space-imposed requirements for evaluating cardiovascular deconditioning. It consists of a pulse generator, pulse receiver amplifier, voltage comparator, synchronous pulse generator, elapsed time counter, and transmit and receive piezoelectric crystals resonant at 2 MHz and of 3 mm diameter. The transit time for an ultrasonic pulse to propagate across a limb cross section is computed in a digital fashion using a 32 MHz clock, and resolution is 0.049 mm with the range being approximately 200 mm. Experimental results regarding dynamic system response were found comparable in both accuracy and sensitivity to those of a Whitney strain gage using a 50 torr venous occlusion.

Bhagat, P. K.↗

A compact x-ray diffraction system for dynamic compression experiments on pulsed-power generators

Pulsed-power generators can produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies using the magnetic loading technique. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength–strain rate dependence, structural phase transitions, and density of crystal defects, such as dislocations. Here, we present a cost-effective, compact, pulsed x-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically driven ramp compression of materials with a single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials’ community to investigate in situ dynamic phase transitions critical to equation of states. Finally, we present results using this new diagnostic to evaluate lattice compression in Zr and Al and to capture signatures of phase transitions in CdS.

47 OTHER INSTRUMENTATION↗

Generation and Study of Am(IV) by Temperature-Controlled Electron Pulse Radiolysis

Used nuclear fuel (UNF) separation techniques that strive to separate radiotoxic americium (Am) from trivalent lanthanide fission products through oxidation state control have increased research efforts surrounding Am(V) and Am(VI). However, equivalent knowledge of the tetravalent state, Am(IV), has remained elusive, particularly in conditions more representative of UNF reprocessing, i.e., in concentrated nitric acid (HNO3). With this in mind, we have used electron pulse radiolysis to study the radiation-induced redox reaction of Am(III) with the oxidizing nitrate radical (NO3?) in 6 M HNO3: Am(III) + NO3? ? Am(IV) + NO3? . These experiments enabled us to observe the growth and decay of Am(IV) in a concentrated acidic solution for the first time. The transient Am(IV) species was found to have a lifetime of ~16 µs?sufficiently long-lived to play a critical mechanistic role in UNF reprocessing systems. Additionally, we performed the first-ever temperature-dependent kinetics study of an actinide element, elucidating unprecedented Arrhenius and Eyring activation parameters for the reaction of Am(III) with NO3?. This new knowledge provides much-needed molecular-level insights into the radiation-induced behavior of Am.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Adaptive Phase Delay Generator

There are several experimental setups involving rotating machinery that require some form of synchronization. The adaptive phase delay generator (APDG) the Bencic-1000 is a flexible instrument that allows the user to generate pulses synchronized to the rising edge of a tachometer signal from any piece of rotating machinery. These synchronized pulses can vary by the delay angle, pulse width, number of pulses per period, number of skipped pulses, and total number of pulses. Due to the design of the pulse generator, any and all of these parameters can be changed independently, yielding an unparalleled level of versatility. There are two user interfaces to the APDG. The first is a LabVIEW program that has the advantage of displaying all of the pulse parameters and input signal data within one neatly organized window on the PC monitor. Furthermore, the LabVIEW interface plots the rpm of the two input signal channels in real time. The second user interface is a handheld portable device that goes anywhere a computer is not accessible. It consists of a liquid-crystal display and keypad, which enable the user to control the unit by scrolling through a host of command menus and parameter listings. The APDG combines all of the desired synchronization control into one unit. The experimenter can adjust the delay, pulse width, pulse count, number of skipped pulses, and produce a specified number of pulses per revolution. Each of these parameters can be changed independently, providing an unparalleled level of versatility when synchronizing hardware to a host of rotating machinery. The APDG allows experimenters to set up quickly and generate a host of synchronizing configurations using a simple user interface, which hopefully leads to faster results.

Greer, Lawrence↗

Versatile logic system for use in nuclear experiments on scientific satellites.

An improved fast low-power-drain logic system has been developed for use in nuclear experiments on scientific satellites. The basic unit of the system is an AND-NAND gate which has a response in the 10-nsec range, a power drain of 2.0 mw and operates over the temperature range of -40 to +80 C. In addition to providing the AND-NAND logic functions, one or more of the basic units may be connected to yield a monostable pulse generator, a pulse generator proceeding an output pulse at the leading edge of the input pulse, a delay, a threshold detector, and a bistable circuit. The system requires relatively simple circuitry for interfacing at its outputs and inputs.

Cancro, C. A.↗

Programmable random interval generator

Random pulse generator can supply constant-amplitude randomly distributed pulses with average rate ranging from a few counts per second to more than one million counts per second. Generator requires no high-voltage power supply or any special thermal cooling apparatus. Device is uniquely versatile and provides wide dynamic range of operation.

Lindsey, R. S., Jr.↗

Space Derived Health Aids (AID, Heart Monitor)

CPI's spinoff from miniaturized pace circuitry is the new heart-assist device, the AID implantable automatic pulse generator. AID pulse generator monitors the heart continuously, recognizes onset of fibrillation, then administers a corrective electrical shock. A mini- computer, a power source, and two electrodes which sense heart activity are included in the unit. An associated system was also developed. It includes an external recorder to be worn by AID patients and a physician's console to display the data stored by the recorder. System provides a record of fibrillation occurrences and the ensuing defibrillation.

Source record↗

Low power arcjet thruster pulse ignition

An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

Sarmiento, Charles J.↗

Low power arcjet thruster pulse ignition

An investigation of the pulse ignition characteristics of a 1 kW class arcjet using an inductive energy storage pulse generator with a pulse width modulated power converter identified several thruster and pulse generator parameters that influence breakdown voltage including pulse generator rate of voltage rise. This work was conducted with an arcjet tested on hydrogen-nitrogen gas mixtures to simulate fully decomposed hydrazine. Over all ranges of thruster and pulser parameters investigated, the mean breakdown voltages varied from 1.4 to 2.7 kV. Ignition tests at elevated thruster temperatures under certain conditions revealed occasional breakdowns to thruster voltages higher than the power converter output voltage. These post breakdown discharges sometimes failed to transition to the lower voltage arc discharge mode and the thruster would not ignite. Under the same conditions, a transition to the arc mode would occur for a subsequent pulse and the thruster would ignite. An automated 11 600 cycle starting and transition to steady state test demonstrated ignition on the first pulse and required application of a second pulse only two times to initiate breakdown.

Sarmiento, Charles J.↗

Burst delay line for generating ultrashort pulse bursts with interval tunability from femtoseconds to nanoseconds.

Ultrashort burst laser pulses are important for applications in laser processing and spectroscopy. However, existing burst generators face limitations in pulse time interval tunability and coaxiality. Here, we present a burst pulse generator that delivers coaxial ultrashort pulses with tunable pulse time intervals using a single translation stage. The constructed system produced eight femtosecond pulses with uniform intervals tunable from 100 fs to 1.93 ns, equivalent to burst-internal repetition rates spanning 10 THz to 0.52 GHz. We further demonstrated interval-dependent plasma emission in air filamentation, providing a compact platform to study burst-laser-induced phenomena.

Shimada, Keitaro↗

Apparatus for in-situ nondestructive measurement of Young's modulus of plate structures

A method and apparatus for determining stiffness of a plate-like structure including a monolithic or composite laminate plate entails disposing a device for generating an acoustical pulse against a surface of the plate and disposing a detecting device against the same surface spaced a known distance from the pulse-generating device, and using the pulse-generating device to emit a pulse so as to create an extensional wave in the plate. The detecting device is used to determine a time of flight of the wave over the known distance, and the wave velocity is calculated. A Young's modulus of the plate is determined by a processor based on the wave velocity. Methods and apparatus for evaluating both isotropic plates and anisotropic laminates are disclosed.

Huang, Jerry Qixin↗