Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proton SEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Proton Testing of AMD Ryzen 3 1200 Microprocessors

Single-Event Effects (SEE) testing was conducted on the AMD Ryzen 3 1200 microprocessor. Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

single event functional interrupt (SEFI)↗

Evaluation of the Radiation Susceptibility of a 3D NAND Flash Memory

We evaluated the heavy ion and proton-induced single-event effects (SEE) for a 3D NAND flash. The 3D NAND showed similar single-event upset (SEU) sensitivity to a planar NAND of similar density and performance in the multiple-cell level (MLC) storage mode. However, the single-level-cell (SLC) storage mode of the 3D NAND showed significantly reduced SEU susceptibility. Additionally, the 3D NAND showed less MBU susceptibility than the planar NAND, with reduced number of upset bits per byte and reduced cross sections overall. However, the 3D architecture exhibited angular sensitivities for both base and face angles, reflecting the anisotropic nature of the SEU vulnerability in space. Furthermore, the SEU cross section decreased with increasing fluence for both the 3D NAND and the latest generation planar NAND, indicating a variable upset rate for a space mission. These unique characteristics introduce complexity to traditional ground irradiation test procedures.

single-event upset (SEU)↗

Proton Testing of AMD v1202b System on Chip

Single-Event Effects (SEE) testing was previously conducted on the AMD v1200 System on Chip (SoC) at Massachusetts General Hospital’s (MGH) Francis H. Burr Proton Therapy Center on May 28, 2022, using 200-MeV protons.

Edward J Wyrwas↗

Proton Testing of AMD Ryzen 3 2200G Microprocessors

Single-Event Effects (SEE) testing was conducted on the AMD Ryzen 3 2200G microprocessor with integrated graphics. Testing was conducted at Massachusetts General Hospital's (MGH) Francis H. Burr Proton Therapy Center on June 2nd, 2019.

radiation tesing↗

Proton affinity of the histidine-tryptophan cluster motif from the influenza A virus from ab initio molecular dynamics

Ab initio molecular dynamics calculations have been used to compare and contrast the deprotonation reaction of a histidine residue in aqueous solution with the situation arising in a histidine-tryptophan cluster. The latter is used as a model of the proton storage unit present in the pore of the M2 proton conducting ion channel. We compute potentials of mean force for the dissociation of a proton from the Nδ and Nϵ positions of the imidazole group to estimate the pK a s. Anticipating our results, we will see that the estimated pK a for the first protonation event of the M2 channel is in good agreement with experimental estimates. Surprisingly, despite the fact that the histidine is partially desolvated in the M2 channel, the affinity for protons is similar to that of a histidine in aqueous solution. Importantly, the electrostatic environment provided by the indoles is responsible for the stabilization of the charged imidazolium.

Chemistry↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

Towards a Qualification Data Set: Expanded SEE Data on the P2020 Processor

Earlier P2020 SEE data are compared and expanded to a recent die revision, significantly increasing samples tested by protons by five devices, and by heavy ions by five devices. Earlier tested SEE types are found to be fairly similar in register, L1 cache, L2 cache, and CPU crashes. New test methods give SEE performance for the flash memory controller, watchdog circuit, and a built-in Ethernet port on the P2020 processor. Results from heavy ion and proton tests are presented, with data separated over a large number of specific error types and test programs.

Vartanian, Sargeh↗

Final Project Report for project titled "Fluoroalkylphosphonic-acid-based proton conductors"

The overall objective of this research was to create new proton-conducting polymer electrolytes for use in energy conversion devices including hydrogen fuel cells that could operate at high temperatures (95-130 C) and under low relative humidity (< 50% RH) conditions. The new polymers were based on the fluoroalkylphosphonic and phosphinic acid (FPA) groups (see illustration below) which offer prospects for rapid proton transport by a proton-hopping mechanism similar to that which operates in phosphoric acid, a well-known proton-transporting electrolyte that is used in a class of hydrogen fuel cells that work well under the conditions noted above and are already commercially successful. The two specific project objectives were as follows: (1) synthesize and characterize new proton-conducting electrolytes based on the fluoroalkylphosphonic and phosphinic acid (FPA) functional groups; and (2) create and apply new computer models to study protonic conduction in FPA-based electrolytes. The project was successful in creating the desired polymer electrolytes and also a series of molecular model compounds which were used to study proton transport in FPA electrolytes in general. Computer models were created to study both structure and proton-transport dynamics in the electrolytes, particularly the molecular model compounds. Rapid proton transport by a hopping mechanism was found in many of the model compounds and correlations with transport rates with molecular structure were identified. Several polymeric analogs of FPA model compounds were prepared and studied, however FPA-based polymeric materials having very high protonic conductivities under either wet or dry conditions were not obtained. Several possible reasons for the failure of polymeric materials to exhibit the expected high protonic conductivities were identified, including a failure of the polymers to adopt the phase-separated secondary structure/morphology necessary for high proton conductivity, and an unexpected polymer crosslinking effect of acidic groups having two P-OH groups. The project has lent insight into how FPA groups transport protons in both liquid and polymeric forms, which provides guidance to future efforts to design and prepare future generations of proton-conducting polymer electrolytes for hydrogen fuel cells and other types of electrochemical energy conversion and storage devices.

08 HYDROGEN↗

Board Level Proton Testing Book of Knowledge for NASA Electronic Parts and Packaging Program

This book of knowledge (BoK) provides a critical review of the benefits and difficulties associated with using proton irradiation as a means of exploring the radiation hardness of commercial-off-the-shelf (COTS) systems. This work was developed for the NASA Electronic Parts and Packaging (NEPP) Board Level Testing for the COTS task. The fundamental findings of this BoK are the following. The board-level test method can reduce the worst case estimate for a board's single-event effect (SEE) sensitivity compared to the case of no test data, but only by a factor of ten. The estimated worst case rate of failure for untested boards is about 0.1 SEE/board-day. By employing the use of protons with energies near or above 200 MeV, this rate can be safely reduced to 0.01 SEE/board-day, with only those SEEs with deep charge collection mechanisms rising this high. For general SEEs, such as static random-access memory (SRAM) upsets, single-event transients (SETs), single-event gate ruptures (SEGRs), and similar cases where the relevant charge collection depth is less than 10 μm, the worst case rate for SEE is below 0.001 SEE/board-day. Note that these bounds assume that no SEEs are observed during testing. When SEEs are observed during testing, the board-level test method can establish a reliable event rate in some orbits, though all established rates will be at or above 0.001 SEE/board-day. The board-level test approach we explore has picked up support as a radiation hardness assurance technique over the last twenty years. The approach originally was used to provide a very limited verification of the suitability of low cost assemblies to be used in the very benign environment of the International Space Station (ISS), in limited reliability applications. Recently the method has been gaining popularity as a way to establish a minimum level of SEE performance of systems that require somewhat higher reliability performance than previous applications. This sort of application of the method suggests a critical analysis of the method is in order. This is also of current consideration because the primary facility used for this type of work, the Indiana University Cyclotron Facility (IUCF) (also known as the Integrated Science and Technology (ISAT) hall), has closed permanently, and the future selection of alternate test facilities is critically important. This document reviews the main theoretical work on proton testing of assemblies over the last twenty years. It augments this with review of reported data generated from the method and other data that applies to the limitations of the proton board-level test approach. When protons are incident on a system for test they can produce spallation reactions. From these reactions, secondary particles with linear energy transfers (LETs) significantly higher than the incident protons can be produced. These secondary particles, together with the protons, can simulate a subset of the space environment for particles capable of inducing single event effects (SEEs). The proton board-level test approach has been used to bound SEE rates, establishing a maximum possible SEE rate that a test article may exhibit in space. This bound is not particularly useful in many cases because the bound is quite loose. We discuss the established limit that the proton board-level test approach leaves us with. The remaining possible SEE rates may be as high as one per ten years for most devices. The situation is actually more problematic for many SEE types with deep charge collection. In cases with these SEEs, the limits set by the proton board-level test can be on the order of one per 100 days. Because of the limited nature of the bounds established by proton testing alone, it is possible that tested devices will have actual SEE sensitivity that is very low (e.g., fewer than one event in 1 × 10(exp 4) years), but the test method will only be able to establish the limits indicated above. This BoK further examines other benefits of proton board-level testing besides hardness assurance. The primary alternate use is the injection of errors. Error injection, or fault injection, is something that is often done in a simulation environment. But the proton beam has the benefit of injecting the majority of actual SEEs without risk of something being missed, and without the risk of simulation artifacts misleading the SEE investigation.

Guertin, Steven M.↗

Neutron diffraction study of the monoclinic to tetragonal structural transition in LaNbO{sub 4} and its relation to proton mobility

The fergusonite-scheelite structural transition of LaNbO{sub 4} was characterized by high-intensity variable temperature neutron powder diffraction in an effort to link structural changes to proton transport in the low temperature monoclinic and high temperature tetragonal polymorphs. The pronounced decrease in enthalpy of proton mobility with increasing temperature in monoclinic LaNbO{sub 4}, identified by Fjeld et al. , was found to coincide with the decrease in a key inter-tetrahedral oxygen separation. At temperatures above the transition, this oxygen to oxygen distance remains constant, behavior that is consistent with the invariant nature of the calculated enthalpy of mobility for the tetragonal phase. This oxygen separation is therefore proposed as the key structural parameter determining the success rate of proton transfer and ultimately the proton diffusion in LaNbO{sub 4}. Infrared measurements performed on acceptor-doped LaNbO{sub 4} show an absorption in the region 2500 to 3700 cm{sup -1} attributed to the O-H stretching motion influenced by hydrogen bonding. - Graphical Abstract: The structural phase transition from monoclinic fergusonite to tetragonal scheelite crystal structure clearly influences the proton conductivity of acceptor-doped LaNbO{sub 4} (see Figure). The present article attempts to explain why. Highlights: Black-Right-Pointing-Pointer Transition from monoclinic to tetragonal structure studied using neutron diffraction. Black-Right-Pointing-Pointer Change in proton mobility linked to contraction of a key oxygen separation. Black-Right-Pointing-Pointer Infra-red spectra reveal intermediate strength hydrogen bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton Radiography Peers into Metal Solidification

Historically, metals are cut up and polished to see the structure and to infer how processing influences the evolution. We can now peer into a metal during processing without destroying it using proton radiography. Understanding the link between processing and structure is important because structure profoundly affects the properties of engineering materials. Synchrotron x-ray radiography has enabled real-time glimpses into metal solidification. However, x-ray energies favor the examination of small volumes and low density metals. In this study, we use high energy proton radiography for the first time to image a large metal volume (>10,000 mm 3 ) during melting and solidification. We also show complementary x-ray results from a small volume (<1mm 3 ), bridging four orders of magnitude. In conclusion, real-time imaging will enable efficient process development and the control of the structure evolution to make materials with intended properties; it will also permit the development of experimentally informed, predictive structure and process models.

36 MATERIALS SCIENCE↗

Predicting image blur in proton radiography: comparisons between measurements and Monte Carlo simulations

Given the cost and lead-times involved in high-energy proton radiography, it is prudent to model proposed radiographic experiments to see if the images predicted would return useful information. We recently modified our raytracing transmission radiography modeling code HADES to perform simplified Monte Carlo simulations of the transport of protons in a proton radiography beamline. Beamline objects include the initial diffuser, vacuum magnetic fields, windows, angle-selecting collimators, and objects described as distorted 2D (planar or cylindrical) meshes or as distorted 3D hexahedral meshes. We present an overview of the algorithms used for the modeling and code timings for simulations through typical 2D and 3D meshes. We next calculate expected changes in image blur as scattering materials are placed upstream and downstream of a resolution test object (a 3 mm thick sheet of tantalum, into which 0.4 mm wide slits have been cut), and as the current supplied to the focusing magnets is varied. We compare and contrast the resulting simulations with the results of measurements obtained at the 800 MeV Los Alamos LANSCE Line-C proton radiography facility.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of differential cross sections for Z bosons produced in association with charm jets in pp collisions at $\sqrt{s} =$ 13 TeV

Measurements are presented of differential cross sections for the production of Z bosons in association with at least one jet initiated by a charm quark in pp collisions at $ \sqrt{s} $ = 13 TeV. The data recorded by the CMS experiment at the LHC correspond to an integrated luminosity of 35.9 fb$^{−1}$. The final states contain a pair of electrons or muons that are the decay products of a Z boson, and a jet consistent with being initiated by a charm quark produced in the hard interaction. Differential cross sections as a function of the transverse momentum p$_{T}$ of the Z boson and p$_{T}$ of the charm jet are compared with predictions from Monte Carlo event generators. The inclusive production cross section 405.4 ± 5.6 (stat) ± 24.3 (exp) ± 3.7 (theo) pb, is measured in a fiducial region requiring both leptons to have pseudorapidity |η| < 2.4 and p$_{T}$> 10 GeV, at least one lepton with p$_{T}$> 26 GeV, and a mass of the pair in the range 71–111 GeV, while the charm jet is required to have p$_{T}$> 30 GeV and |η| < 2.4. These are the first measurements of these cross sections in proton-proton collisions at 13 TeV.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrostatic Solar Sail: A Propellantless Propulsion Concept for an Interstellar Probe Mission

The propulsion of an electrostatic solar sail (E Sail) is obtained by extracting momentum from the solar wind through electrostatic repulsion of the positively charged solar wind ions (see Figure 1). The positively charged solar wind protons are deflected by the electric field created around the tethers.This electric field grows in diameter as the spacecraft moves away from the Sun, therefore the E Sail effective area grows. The growth of the E-Sail effective area allows the propulsive force to decrease as 1/r up to distances of 20 AU as it moves away from the Sun, unlike solar sail propulsion whose thrust decreases as 1/r 2 but only to distances of 5AU. This propulsive force is created without using propellant and, therefore, E-sail avoids both the mass and complexity of chemical rockets (that require large amounts of propellant, propellant storage tanks, plumbing, valves, and insulation).

DeStefano, Anthony M.↗

SU-E-T-550: Range Effects in Proton Therapy Caused by Systematic Errors in the Stoichiometric Calibration

Purpose: The procedure for proton treatment planning involves the conversion of the patient's X-ray CT from Hounsfield units into relative stopping powers (RSP), using a stoichiometric calibration curve (Schneider 1996). In clinical practice a 3.5% margin is added to account for the range uncertainty introduced by this process and other errors. RSPs for real tissues are calculated using composition data and the Bethe-Bloch formula (ICRU 1993). The purpose of this work is to investigate the impact that systematic errors in the stoichiometric calibration have on the proton range. Methods: Seven tissue inserts of the Gammex 467 phantom were imaged using our CT scanner. Their known chemical compositions (Watanabe 1999) were then used to calculate the theoretical RSPs, using the same formula as would be used for human tissues in the stoichiometric procedure. The actual RSPs of these inserts were measured using a Bragg peak shift measurement in the proton beam at our institution. Results: The theoretical calculation of the RSP was lower than the measured RSP values, by a mean/max error of - 1.5/-3.6%. For all seven inserts the theoretical approach underestimated the RSP, with errors variable across the range of Hounsfield units. Systematic errors for lung (average of two inserts), adipose and cortical bone were - 3.0/-2.1/-0.5%, respectively. Conclusion: There is a systematic underestimation caused by the theoretical calculation of RSP; a crucial step in the stoichiometric calibration procedure. As such, we propose that proton calibration curves should be based on measured RSPs. Investigations will be made to see if the same systematic errors exist for biological tissues. The impact of these differences on the range of proton beams, for phantoms and patient scenarios, will be investigated. This project was funded equally by the Engineering and Physical Sciences Research Council (UK) and Ion Beam Applications (Louvain-La-Neuve, Belgium)

60 APPLIED LIFE SCIENCES↗