At least 91 records · Page 5

The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

In response to the elimination of production of several Ozone Depleting Chemicals (ODCs) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-Free cleaning procedures. One leg of that philosophy is the initiation of a several tier testing program which will deliver increasing amounts of information over the next few years, starting with original surface analysis comparisons between ODC and various ODC-Free cleaning technologies. The other leg is the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years with a number of important tribological questions unanswered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life mechanism based on a number of parameters, including a comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODCs based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

Predmore, Roamer↗

The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

In response to the elimination of production of several Ozone Depleting Chemicals (ODC's) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-free cleaning procedures. The short term leg of the philosophy was the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. The long-term leg of that philosophy was the initiation of a several tier testing program that will deliver increasing amounts of information over the next few years, starting with accelerated lubricant life tests that compare lubricant life on surfaces cleaned with ODC solvents with lubricant life on surfaces cleaned with ODC-free solvents. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years before a number of important tribological questions can be answered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life lubricated mechanism based on a number of parameters, including 4 comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODC's based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

Predmore, Roamer↗

Rhenium in seawater - Confirmation of generally conservative behavior

A depth profile of the concentration of Re was measured in the Pacific Ocean using a technique developed for the clean chemical separation and the precise measurement of Re by isotope dilution and negative thermal ionization mass spectrometry (ID-NTIMS). We obtain a narrow range for Re from 7.20 +/- 0.03 to 7.38 +/- 0.03 ng/kg for depths between 45 m and 4700 m. This demonstrates that Re is relatively well mixed throughout the water column and confirms the theoretical prediction that the behavior of Re in the oceans is conservative. When examined in detail, both salinity and the concentration of Re increase by approximately 1.5 percent between 400 and 4700 m, a correlation consistent with conservative behavior. However, Re appears to be depleted relative to salinity by 1.0-1.5 percent at 100 m, and enriched by approximately 4 percent at the surface. These observations suggest a minor level of Re scavenging in near surface waters, and an input of Re to the ocean surface. This work demonstrates the utility of geochemical investigations of certain trace elements not previously been amenable to detailed study.

Anbar, A. D.↗

Development of CFC-Free Cleaning Processes at the NASA White Sands Test Facility

The NASA White Sands Test Facility (WSTF) is developing cleaning and verification processes to replace currently used chlorofluorocarbon-113- (CFC-113-) based processes. The processes being evaluated include both aqueous- and solvent-based techniques. The presentation will include the findings of investigations of aqueous cleaning and verification processes that are based on a draft of a proposed NASA Kennedy Space Center (KSC) cleaning procedure. Verification testing with known contaminants, such as hydraulic fluid and commonly used oils, established correlations between nonvolatile residue and CFC-113. Recoveries ranged from 35 to 60 percent of theoretical. WSTF is also investigating enhancements to aqueous sampling for organics and particulates. Although aqueous alternatives have been identified for several processes, a need still exists for nonaqueous solvent cleaning, such as the cleaning and cleanliness verification of gauges used for oxygen service. The cleaning effectiveness of tetrachloroethylene (PCE), trichloroethylene (TCE), ethanol, hydrochlorofluorocarbon-225 (HCFC-225), tert-butylmethylether, and n-Hexane was evaluated using aerospace gauges and precision instruments and then compared to the cleaning effectiveness of CFC-113. Solvents considered for use in oxygen systems were also tested for oxygen compatibility using high-pressure oxygen autoignition and liquid oxygen mechanical impact testing.

Beeson, Harold↗

Clean Electrical-Discharge Machining Of Delicate Honeycomb

Precise recesses in fragile metal honeycomb blocks formed in special electrical-discharge machining process. Special tooling used, and recesses bored with workpiece in nonstandard alignment. Cutting electrode advances into workpiece along x axis to form pocket of rectangular cross section. Deionized water flows from fitting, along honeycomb tubes of workpiece, to electrode/workpiece interface.

Johnson, Clarence S.↗

Laser Surface Preparation and Bonding of Aerospace Structural Composites

Adhesive bonds are critical to the integrity of built-up structures. Disbonds can often be detected but the strength of adhesion between surfaces in contact is not obtainable without destructive testing. Typically the number one problem in a bonded structure is surface contamination, and by extension, surface preparation. Standard surface preparation techniques, including grit blasting, manual abrasion, and peel ply, are not ideal because of variations in their application. Etching of carbon fiber reinforced plastic (CFRP) panels using a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser appears to be a highly precise and promising way to both clean a composite surface prior to bonding and provide a bond-promoting patterned surface akin to peel ply without the inherent drawbacks from the same (i.e., debris and curvature). CFRP surfaces prepared using laser patterns conducive to adhesive bonding were compared to typical prebonding surface treatments through optical microscopy, contact angle goniometry, and post-bonding mechanical testing.

Belcher, M. A.↗

Laser Surface Preparation for Adhesive Bonding of Aerospace Structural Composites

Adhesive bonds are critical to the integrity of built-up structures. Disbonds can often be detected but the strength of adhesion between surfaces in contact is not obtainable without destructive testing. Typically the number one problem in a bonded structure is surface contamination, and by extension, surface preparation. Standard surface preparation techniques, including grit blasting, manual abrasion, and peel ply, are not ideal because of variations in their application. Etching of carbon fiber reinforced plastic (CFRP) panels using a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser appears to be a highly precise and promising way to both clean a composite surface prior to bonding and provide a bond-promoting patterned surface akin to peel ply without the inherent drawbacks from the same (i.e., debris and curvature). CFRP surfaces prepared using laser patterns conducive to adhesive bonding were compared to typical pre-bonding surface treatments through optical microscopy, contact angle goniometry, and post-bonding mechanical testing.

Belcher, M. A.↗

Toll-Booth Purification

NASA's Technology Application Team at Stanford Research Institute searched available information and suggested a transfer of clean-room technology employing the use of the same laminar flow techniques found in environmental control systems of clean rooms used for contamination-free assembly of precision aerospace equipment. That information, from technology originally developed by NASA and the Energy Research & Development Administration was incorporated in the design of a prototype toll booth purifier. The draft-free design includes a "diffusor", which blows clean air out the toll booth doorway, thus retarding the infiltration of contaminated air. The net effect is a decrease in the toll collector's inhalation of exhaust fumes. The Washington Department of Highways installed the prototype system in a toll booth at the Evergreen Point Bridge near Seattle. After a successful two-year test, the department now has equipped all 10 of the bridge's toll booths with the air purifiers.

Source record↗

Vacuum mechatronics

The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

Hackwood, Susan↗

It's a Clean Machine

Under an SBIR (Small Business Innovative Research) from Lewis Research Center, Precision Combustion, Inc. (PCI) developed the Advanced Technology Catalytic Combustor. The research proved the viability of efficient, cost-effective catalytic reduction of gas turbine nitrogen oxide emissions along with fuel efficiency. PCI has signed agreements with Westinghouse, other gas turbine manufacturers, including Capstone Turbine Corporation to develop a catalytic combustor for their hybrid electric vehicle.

Source record↗

Repurposing the James Webb Space Telescope’s center of curvature optical bench hexapod for future mirror calibration testing at NASA Marshall’s x-ray & cryogenic facility

The James Webb Space Telescope’s (JWST) center of curvature optical bench (CoCOB) hexapod was repurposed to enhance NASA Marshall Space Flight Center’s X-Ray & Cryogenic Facility (XRCF) optical metrology capabilities. This upgrade unlocked higher test article load capacity and extended the allowable ranges of motion of the CoCOB hexapod. The hexapod was also coupled to a new long-stroke, linear motion axis to form a 7 degrees of freedom system and allow for high precision testing of larger diameter test articles. A 9 degrees of freedom motion system, consisting of a three-axis linear mount in an X-Y-Z configuration and a commercially available hexapod, was also designed to allow high resolution positioning of the focal plane instrumentation over a large range of motion. A modern control architecture and graphical user interface was developed for the CoCOB hexapod and additional motion stages to permit streamlined commanding and operation. This paper discusses the justification for re-using the CoCOB hexapod by highlighting its unique precision motion control capabilities in a high vacuum and optically clean environment. The design, key component selection, and environmental compatibility for each of the additional motion stages is presented along with testing results for achieved range, repeatability, and minimum step size performance for all motion axes. Finally, a summary of the motion control system architecture and its flexibility to address tomorrow’s optical metrology needs are presented.

hexapod↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surface of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The six commonly used methods for establishing objective cleanliness acceptance limits will be discussed. Special emphasis shall focus on the use of multiple extraction, a technique that has been demonstrated for additively manufactured parts.

Welker, Roger W.↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surfaces of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The methods for establishing objective cleanliness acceptance limits will be discussed.

Mitchell, Mark A.↗

Prospects for Probing Strong Gravity with a Pulsar-Black Hole System

The discovery of a pulsar (PSR) in orbit around a black hole (BH) is expected to provide a superb new probe of relativistic gravity and BH properties. Apart from a precise mass measurement for the BH, one could expect a clean verification of the dragging of space-time caused by the BH spin. In order to measure the quadrupole moment of the BH for testing the no-hair theorem of general relativity (GR), one has to hope for a sufficiently massive BH. In this respect, a PSR orbiting the super-massive BH in the center of our Galaxy would be the ultimate laboratory for gravity tests with PSRs. But even for gravity theories that predict the same properties for BHs as GR, a PSR-BH system would constitute an excellent test system, due to the high grade of asymmetry in the strong field properties of these two components. Here we highlight some of the potential gravity tests that one could expect from different PSR-BH systems.

gravity↗

Magnetically suspended stepping motors for clean room and vacuum environments

To answer the growing needs for super-clean or contact free actuators for uses in clean rooms, vacuum chambers, and space, innovative actuators which combine the functions of stepping motors and magnetic bearings in one body were developed. The rotor of the magnetically suspended stepping motor is suspended like a magnetic bearing and rotated and positioned like a stepping motor. The important trait of the motor is that it is not a simple mixture or combination of a stepping motor and conventional magnetic bearing, but an amalgam of a stepping motor and a magnetic bearing. Owing to optimal design and feed-back control, a toothed stator and rotor are all that are needed structurewise for stable suspension. More than ten types of motors such as linear type, high accuracy rotary type, two-dimensional type, and high vacuum type were built and tested. This paper describes the structure and design of these motors and their performance for such applications as precise positioning rotary table, linear conveyor system, and theta-zeta positioner for clean room and high vacuum use.

Higuchi, Toshiro↗

Cleaning Study of Genesis Sample 60487

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. Particles of Genesis wafers, brine from the Utah Testing Range and an organic film have deleterious effects on many of the high-resolution instruments that have been developed to analyze the implanted solar wind. We have conducted a correlative microscopic study of the efficacy of cleaning Genesis samples with megasonically activated ultrapure water and UV/ozone cleaning. Sample 60487, the study sample, is a piece of float-zone silicon from the B/C array approximately 4.995mm x 4.145 mm in size

Kuhlman, Kim R.↗

Isotopic, Chemical and Mineralogical Investigations of Extraterrestrial Materials

The principal aim of our work was to improve our understanding of the earliest evolutionary period of our solar system (i.e. the first tens of millions of years). We have studied its chronology by using short and long term chronometers (based on extinct and long lived radioactive nuclei), explored the bearing of short lived nuclei on planetary heating and differentiation, and the addition of 'exotic' nuclei to solar system matter to help constrain models of nucleosynthesis. Our basic tool is high precision Thermal Ionization Mass Spectrometry (TIMS). Over the years we have developed clean chemical separation procedures for many elements. The chemical elements most relevant to our investigations are Cr, Ni, Rb, Sr, Sm, Nd, Pb, and U, for which highly efficient measurement techniques by TIMS have been developed and have been in use in our laboratory for many years. We have explored the Mn-53 Cr-53 system (T (Mn-53) = 3.7 Ma) and have found it to be a powerful tool to obtain relative ages of meteorite formation and, more general, of early solar system processes with a time resolution of approx. 1 Ma. By measuring the Mn-Cr system in many meteorite types (chondrites, basaltic achondrites, angrites, pallasites, etc.) we have found that this condition is indeed met for most meteorite families.

Lugmair, Guenter W.↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗