Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Tall Lunar Tower (TLT) Powering Exploration at the Moon's South Pole

Animation of a conceptual Lunar mission for the Tall Lunar Tower (TLT) robotic in-space assembly system. The landing, deployment, and operation of the tower assembly system is shown. A successful tower assembly and solar power payload is depicted at the lunar south pole. The video is intended to convey how an engineering development unit (EDU) demonstrated at NASA Langley Research Center may look when operated on the Lunar surface. The EDU models are shown in place of flight hardware. The animation was produced by the Advanced Concepts Laboratory with models provided by the TLT team.

Tall Lunar Tower↗

Estimating the cost of high temperature liquid metal based concentrated solar power

The present levelized cost of electricity from concentrated solar power is too high to directly compete with natural gas under current carbon emissions policies. An approximate 50% cost reduction is needed relative to current power tower technology based on molten nitrate salts, and one pathway to a major cost reduction is to operate the system at higher temperatures, enabling a more efficient heat engine. Here, we consider a future system that can operate at gas turbine inlet temperatures of ~1300–1500 °C by using liquid metals as heat transfer and storage fluids with a ceramic based piping infrastructure. In general, ceramics are more expensive than the current stainless steels, but they are less expensive than the nickel alloys that are proposed to be used in higher temperature chloride molten salt plants. Considering various tradeoffs, it was not clear a priori whether or not the potential gains in heat engine efficiency would be negated by increased material costs or how much net reduction in levelized cost might be possible. This study answers this question by first detailing a base case molten nitrate salt power tower plant with published cost data. Then, a future liquid metal version of a power tower is modeled using similar specifications as the liquid salt plant to determine if there are any obvious costs that might negate the efficiency gains associated with operating well above 1000 °C. The results of the analysis showed that although the receiver and several other sub-systems become more expensive, there is a net cost reduction in the range of 20%–30%, depending upon the heat engine efficiency.

14 SOLAR ENERGY↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

CSP Systems Analysis - Final Project Report

The CSP Systems Analysis project was a three-year effort supporting the Concentrating Solar Power (CSP) Subprogram within the Solar Energy Technologies Office of the U.S. Department of Energy (DOE). The goal of the CSP Systems Analysis project was to provide timely and accurate CSP cost data to the DOE and predict performance and cost for emerging technologies that may impact research directions and industry investment. The project consisted of six, mostly independent tasks. Major accomplishments over the three-year period of performance were as follows. The NREL team maintained current cost estimates for CSP technologies by annual updates to the cost input parameters within NREL's System Advisor Model (SAM). SAM is a performance and cost simulation software that includes technology models for the primary CSP technologies. During the period from 2016 to 2018, the estimated cost within SAM's default CSP molten-salt power tower technology dropped from 13.0 to 11.1 cent/kWh (real dollars without incentives). Power cycle models for the supercritical carbon dioxide (sCO2) Brayton Cycle were developed and made an option within SAM's molten-salt power tower model. These models were subsequently used to evaluate the cost reduction potential of alternative salts. The partial-cooling model was found to provide the greatest cost-reduction potential due to its combination of efficiency and temperature differential across the turbine and thermal energy storage (TES) system. These studies were documented in two journal articles. NREL's optical modeling software SolTrace and SolarPILOT were made more versatile and released as open-source software to the CSP community. These tools help researchers and developers to model and optimize the optical performance of CSP collector systems. The new features were highlighted in a recorded webinar that can be accessed from the NREL SAM website. New models for solar-thermal systems, that is, applications for solar industrial process heat, were developed, validated, and installed within SAM. The analysis includes a 2018 review of linear collectors in the market that are tailored for solar process heat applications. In 2018 the NREL team also developed an annual simulation for a direct steam generation system integrated with a latent-heat TES system. This analysis was submitted for journal publication. The NREL team continued to support the exchange of information and development of CSP guidelines within the international CSP community of SolarPACES. Much of the work under this project was presented at SolarPACES, including the development of a modeling checklist to help CSP stakeholders standardize the models used for estimating CSP performance and cost. The CSP Systems Analysis project also supported DOE requests for tracking and reporting programmatic targets for the CSP Subprogram.

14 SOLAR ENERGY↗

System-Level Comparison of Sodium and Salt Systems in Support of the Gen3 Liquids Pathway

This paper presents the comparison of the annual performance and the Levelised Cost of Energy (LCOE) of two high- temperature solar power tower configurations using a 565MWth chloride salt receiver and a 540 MWth liquid sodium receiver. Each power tower consists of a sodium or salt receiver, a 175 m high concrete tower, and a two-tank chloride salt system for thermal energy storage (TES). The power plants were simulated using SolarTherm to estimate their energy per year, capacity factor, and LCOE. The simulation was verified against the System Advisor Model (SAM), showing that the LCOE calculation differences are within ±1.0%. Results showed that the sodium-receiver system yields 69.60 USD/MWh real LCOE, versus 78.55 USD/MWh for the chloride salt system. Results also showed that sodium wins here due to a smaller and more efficient receiver, enabled by higher flux limits and reduced field size, leading to less mirror reflective area and site improvement cost.

capacity factor↗

Concentrating Solar Power - Molten Salt Pump Development, Final Technical Report (Phase 1)

The purpose of this project is to develop a long shafted pump to operate at high temperatures for the purpose of producing energy with renewable resources. In Phase I of this three phase project we developed molten salt pump requirements, evaluated existing hardware designs for necessary modifications, developed a preliminary design of the pump concept, and developed refined cost estimates for Phase II and Phase III of the project. The decision has been made not to continue the project into Phases II and III. There is an ever increasing world-wide demand for sources of energy. With only a limited supply of fossil fuels, and with the costs to obtain and produce those fuels increasing, sources of renewable energy must be found. Currently, capturing the sun's energy is expensive compared to heritage fossil fuel energy production. However, there are government requirements on Industry to increase the amount of energy generated from renewable resources. The objective of this project is to design, build and test a long-shafted, molten salt pump. This is the type of pump necessary for a molten salt thermal storage system in a commercial-scale solar trough plant. This project is under the Department of Energy (DOE) Solar Energy Technologies Program, managed by the Office of Energy Efficiency and Renewable Energy. To reduce the levelized cost of energy (LCOE), and to meet the requirements of 'tomorrows' demand, technical innovations are needed. The DOE is committed to reducing the LCOE to 7-10 cents/kWh by 2015, and to 5-7 cents/kWh by 2020. To accomplish these goals, the performance envelope for commercial use of long-shafted molten salt pumps must be expanded. The intent of this project is to verify acceptable operation of pump components in the type of molten salt (thermal storage medium) used in commercial power plants today. Field testing will be necessary to verify the integrity of the pump design, and thus reduce the risk to industry. While the primary goal is to design a pump for a trough solar power plant system, the intent is for the design to be extensible to a solar power tower application. This can be accomplished by adding pumping stages to increase the discharge pressure to the levels necessary for a solar power tower application. This report incorporates all available conceptual design information completed for this project in Phase I.

14 SOLAR ENERGY↗

Concurrent Optimization of Capital Cost and Expected O&M

Concentrating solar power (CSP) technologies can utilize heat from concentrated sunlight from a field of tracking mirrors to generate electricity, reform fuel, provide process heat, or augment fossil plant heat sources. Electricity-generating power tower systems focus light from thousands of independent heliostats onto a thermal receiver, which uses the focused light to warm a heat transfer fluid (HTF), typically, a molten nitrate salt. The HTF is then sent to a power generation cycle or diverted into thermal energy storage (TES) for later use. Thermal storage is – in principle – a straightforward proposition. However, optimal utilization of a TES resource is complex and multi-faceted: thermal energy may be dispatched to produce electricity immediately upon first availability, or thermal energy may be reserved for next-day peak periods at risk of filling storage and dumping energy, or a portion of the thermal energy can be reserved to maintain equipment temperatures, reducing power cycle startup time, etc. Many possible dispatch permutations variously emphasize producing peak power, operating through transients, expediting daily startup, etc. The best operation strategy can change day-to-day throughout the year, depending on the weather and market pricing forecasts. The project we describe in this report develops a software package that allows users to explore design optimization, operations decisions, and performance characterization of concentrating solar power tower plants. Users interface with the tool through a scripting language, and results are reported in time series tables, plots, runtime logs, and design outputs. Users choose from a list of variables such as tower height, solar multiple, design-point irradiance, thermal storage size, etc., and specify information about the system using a list of parameters. The software can then optimize the specified variables to reduce the cost of energy produced by the system while meeting certain production requirements, accounting for uncertain weather and electricity price forecasts, and correcting for equipment failures or repair time. The software we develop is the first comprehensive design tool of its kind to incorporate all of these aspects while being deployed as open source.

14 SOLAR ENERGY↗

Estimation of the Attenuation Caused by Power Line Towers on an E1-HEMP Induced Excitation

In a transmission line, the coupling between a line and a tower above ground is evaluated when the excitation is an E1 high-altitude electromagnetic pulse (HEMP). The model focuses on capturing correctly the effect of the coupling on the peak of the HEMP induced current that propagates along the line. This assessment is necessary to accurately estimate the effect of the excitation on the systems and components of the power grid. This analysis is a step towards a quantitative evaluation of HEMP excitation on the power grid. The results obtained indicate that the effect can be significant, especially for lines heights of 20 meters or more.

24 POWER TRANSMISSION AND DISTRIBUTION↗

One-point fitting of the flux density produced by a heliostat

Accurate and simple models for the flux density reflected by an isolated heliostat should be one of the basic tools for the design and optimization of solar power tower systems. In this work, the ability and the accuracy of the Universidad de Zaragoza (UNIZAR) and the DLR (HFCAL) flux density models to fit actual energetic spots are checked against heliostat energetic images measured at Plataforma Solar de Almeria (PSA). Both the fully analytic models are able to acceptably fit the spot with only one-point fitting, i.e., the measured maximum flux. As a practical validation of this one-point fitting, the intercept percentage of the measured images, i.e., the percentage of the energetic spot sent by the heliostat that gets the receiver surface, is compared with the intercept calculated through the UNIZAR and HFCAL models. As main conclusions, the UNIZAR and the HFCAL models could be quite appropriate tools for the design and optimization, provided the energetic images from the heliostats to be used in the collector field were previously analyzed. Also note that the HFCAL model is much simpler and slightly more accurate than the UNIZAR model. (author)

14 SOLAR ENERGY↗

Kink solutions with power law tails

We present a comprehensive review about the various facets of kink solutions with a power law tail, which have received considerable attention during the last few years. This area of research is in its early stages; although several aspects have become clear by now, there are a number of issues which have only been partially understood or not understood at all. We first discuss the aspects which are reasonably well known and then address in some detail the issues which are only partially or not understood at all. We present a wide class of higher (than sixth) order field theory models admitting implicit kink as well as mirror kink solutions where the two tails facing each other have a power law or a power-tower type fall off, whereas the other two ends not facing each other could have either an exponential or a power law tail. The models admitting implicit kink solutions where the two ends facing each other have an exponential tail while the other two ends have a power law tail are also discussed. Moreover, we present several field theory models which admit explicit kink solutions with a power law fall off; we note that in all these polynomial models while the potential V ( ϕ ) is continuous, its derivative is discontinuous. We also discuss one of the most important and only partially understood issues of the kink–kink and the kink–antikink forces in case the tails facing each other have a power law fall off. Finally, we briefly discuss the kink–antikink collisions at finite velocity and present some open questions.

power-tower tail↗

100 MW e Baseload Molten Salt Plant Phase 1 & 2 Summary Report: Summary of Conceptual Design, Preliminary Design, Commercialization and Risk Reduction Activities

This document describes steps taken to develop our conceptual and preliminary designs of a modular concept for deploying a 75% capacity factor, 100-MW e solar power plant. The modular approach consists of 14 solar power towers interconnected by hot and cold salt piping leading back to a central power block where the salt storage tanks and power generation systems are located. The plant is described in several sections. First, the overall plant is described, including the general arrangement, process and heat flow diagrams, system interface definitions, and electrical description. Next, each system is described in detail following the flow of energy from incident sunlight, through the plant, to the grid. These systems include the solar collector system (SCS), solar receiver system (SRS), thermal storage system (TSS), steam generator system (SGS), and power generation system (PGS). Then, the plant control system (PCS) and balance of plant (BOP) are discussed as supporting entities. Each system of the plant is described in sufficient detail to allow for the following to be developed: material cost, erection cost, project schedule, EPC bids, detailed performance modeling, and operations and maintenance cost. Cost, schedule, and performance estimates are not described in this document. Two approaches to demonstration of the technology are presented: a single tower integrated into an existing power block and a four tower stand alone 50 MW e power plant. Various demonstration partners have expressed interested in both approaches. The process by which a detailed plant performance model was developed is described to support the development of accurate LCOE data. Information on material and instrument testing is also provided for critical materials and instruments required for molten salt service.

14 SOLAR ENERGY↗

Development of 800°C Integrated Flow Channel Ceramic Receiver

The project’s objective was to develop an affordable, efficient power tower receiver for future concentrated solar power plants consistent with the SunShot APOLLO goal of 6¢/kWhe for the levelized cost of electricity (LCOE). A conceptual design was generated with the goal of meeting the SunShot objectives for the receiver for performance (≥720°C fluid outlet and ≥90% thermal efficiency), cost (≤$150/kWt), and lifetime (10,000 cycles). The higher temperature design leveraged the development of a new solar absorber coating capable of operating at 800°C with greater capability than state-of-the-art Pyromark paint. An industrial process was developed to manufacture the coating on a large scale (hundreds of gallons) and apply the coating using industrial spray equipment as currently used on our commercial receivers.

14 SOLAR ENERGY↗

Lightning Current Detector

Lightning Current Detector (LCD) was developed to monitor the magnitude of lightning strikes. Information it supplies is useful in evaluating lightning protection designs for such systems as telephone cables, radio broadcast towers, power transmission equipment and oil well towers.

Source record↗

A Method for Projecting Cloud Shadows Onto a Central Receiver Field to Predict Receiver Damage

This work demonstrates methods of mapping high-spatial-resolution direct normal irradiance (DNI) data from satellites, Total Sky Imagers (TSIs), and analogous data sources onto a heliostat field for characterizing the spatial and temporal variation of the incident flux on a central receiver tower during cloud transient events. The mapping methods are incorporated into an optical software module that interfaces with CoPylot–SolarPILOT’s python API– to provide computationally efficient optical simulation of the heliostat field and the solar power tower. Eventually, this optical model will be incorporated into optimization models whereby a plant operator can understand the effects of cloud transient events on overall power production and receiver lifetime due to creep-fatigue damage and therefore make better informed decisions about receiver shutdown events. By more accurately modelling the effects of cloud events on receiver flux maps, this work may determine the magnitude and frequency of thermal cycling on receiver tubes and panels using actual or realistic cloud shapes instead of averaged DNI values–which may undercount the total cycle number. This work may also prevent unnecessary plant shutdowns due to overly precautionary control strategies and characterize the relative impact of various cloud types on receiver life. We plan to eventually integrate this methodology into the System Advisor Model (SAM) to improve performance model accuracy during periods of cloudiness. In this paper, we demonstrate generating DNI maps and mapping them to a solar field in CoPylot using 10 m resolution data from publicly available Sentinel-2 satellite data over the Crescent Dunes plant.

Mullin, Matthew↗

Optimal Heliostat Assignment Strategy for Multiple-Receiver Systems

Next-generation concentrating solar power concepts currently being developed under the U.S. Department of Energy's Gen3 program include several novel heliostat field and receiver arrangements. Among these concepts are solar fields utilizing multiple receivers or several distinct receiver flux control zones, and each of which has particular power or peak flux constraints. In this paper, we present a linear program that identifies optimal heliostat-to-receiver assignment strategies for multi-receiver or multi-zone solar fields based on detailed calculations made by an optics modeling package. Two distinct problems are addressed: namely, (1) a design problem that chooses the optimal set of heliostats to include in a final layout given receiver constraints and performance, and (2) an operations problem that assigns existing heliostats to a receiver, maximizing field power output while maintaining receiver power constraints. The optimization methodology is integrated into the concentrating solar power tower modeling package SolarPILOTTM, and results are presented showing that heliostat assignment strategies can impact both initial heliostat field layout characteristics and the cost of thermal energy produced by the field. The methodology succeeds in maintaining power requirements but at the expense of producing different flux profiles on each receiver surface. Consequently, the paper also discusses additional measures that are applied to ensure that desirable flux distribution properties are maintained, reducing local flux mean-absolute-deviation values from a baseline of 17% or greater to less than 5% compared to a desired reference flux profile.

41 EE - Solar Energy Technologies Office (EE-4S)↗