Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Plant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Wind and Solar Hybrid Power Plants for Energy Resilience

Wind-solar-storage hybrid power plants represent a significant and growing share of new proposed projects in the United States (U.S.). Their uptake is supported by increasing renewable energy market share, technical abilities for dispatch and control, and decreasing wind, solar, and battery storage costs. Simultaneously, generation and storage resources are increasingly used in distributed power systems. While concerns around the reliability of the aging, transforming U.S. electric grid are growing, diversifying energy resources through hybridization or spatial distribution provides an opportunity to enhance power system resilience compared to single-source generation. Understanding where to build hybrids for resilience value, rather than bulk power supply, has not been fully explored in previous studies. Therefore, in this study, we complete a national complementarity analysis to identify areas in the U.S. that are particularly suited for wind-solar hybrid power plant development. We show the importance of seasonal and diurnal patterns in assessing complementarity, and identify that regions in the Great Plains, Midwest, and Southeast are particularly suited for hybrid power plants. We demonstrate the resilience value of hybridization for a reference system based near Memphis, Tennessee, and show optimal sizing of wind, solar, and storage assets given 1.0 and 0.9 critical load factors. Results indicate that pairing wind and solar assets better meet constant load demand and reduce storage requirements compared to solar alone. These results enable future work integrating complementarity metrics in resilience frameworks and indicate a need for more finer resolution of local resource, demand, and hazard data.

14 SOLAR ENERGY↗

Grid Forming Control Tuning for a Hybrid Inverter-Based Resource Power Plant

A hybrid inverter-based resource (IBR) power plant consists of grid-following (GFL) and grid-forming inverter-based resources (GFM-IBR) connected in parallel. Here, this research focuses on how to design and tune GFM's control parameters to ensure stable operation of the hybrid power plant for weak and strong grid conditions. We consider two design cases: one where the GFL-IBR does not provide frequency support, and one where it does. It is found that the GFM's power-frequency synchronizing system can lose stability when the power-frequency droop constant is large and/or the grid is strong. Additionally, if the GFL has its frequency support enabled, oscillation stability worsens. To explain the mechanism of the interactions, we construct a feedback system for the synchronizing loop, which consists of the GFM's power-frequency droop control that generates the GFM's synchronizing angle, the GFL's phase-locked loop that measures the voltage phase angle, the GFL's frequency-power control that generates its power order, and the rest of the system. The feedback system is effective in illustrating the potential stability risks. Successful design ensures that the hybrid power plant can operate smoothly and ride through grid disturbances.

feedback systems↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

How different power plant types contribute to electric grid reliability, resilience, and vulnerability: a comparative analytical framework

Abstract This work explores the dependability tradeoffs provided by the most common types of central power plants in the United States. Historically, the electricity sector has lacked consensus on how reliability , resilience , and vulnerability differ and how those metrics change depending on the power plant fleet composition. We propose distinct definitions for these metrics and an analytical framework to evaluate power plant fleet dependability. Using data analysis and literature review, we identify fifteen dependability attributes across which we rank eleven power plant types relative to natural gas combined-cycle (NGCC) plants. We use NGCC as the benchmark because it is common to many locations and is of relatively recent vintage. The framework shows that each power plant type has unique dependability benefits and drawbacks. We provide examples of how researchers may use the framework to evaluate grid dependability qualitatively under different scenarios. We find that assuming all attributes that contribute to grid dependability are equally important and additive, electric grid dependability is best supported when power plant fleets include a mixture of power generation technologies. Then, we discuss scenario characteristics that could alter the prioritization and relationships of attributes. We also find that if current capacity installation trends continue to favor low- and zero-carbon power plants, US power grids may benefit from increased resilience and reduced vulnerability at the cost of decreased reliability. We conclude by recommending methods for adapting the framework and quantifying relationships between attributes in individual scenarios.

Ramirez-Meyers, K. (ORCID:0000000291216952)↗

Developing an AI-Powered Zero-Trust Cybersecurity Framework for Malware Prevention in Nuclear Power Plants

This study presents the development of an AI-powered Zero-Trust cybersecurity framework for malware prevention in nuclear power plants. The framework aims to enhance the security of critical systems within nuclear power plants by adopting the principles of Zero-Trust and leveraging artificial intelligence (AI) technologies. By assuming no implicit trust in any user or device and continuously authenticating and authorizing access, the framework ensures a robust defense against malware attacks. The integration of AI allows for the detection and prevention of malware through behavioral analytics, endpoint protection, network segmentation, and continuous monitoring. The paper discusses the key considerations, steps, and technologies involved in developing this framework, emphasizing the importance of regular updates, training, compliance, and auditing. The proposed framework serves as a comprehensive approach to safeguarding nuclear power plants from sophisticated malware threats and protecting the integrity and safety of critical infrastructure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Microstructure homogenization of concrete used in nuclear power plants

Almost all nuclear power plants in the United States are operating past their intended lifetimes or are requesting lifetime extensions. Therefore, understanding changes to the concrete containment structure over time is crucial to evaluate the structure’s continued viability. Concrete materials are heterogeneous particulate composites that exhibit viscoelastic material properties, which can lead to slow deformation over time, causing stress redistribution and the potential for creep cracking. A code to generate random, three dimensional (3D) concrete microstructures has been developed and paired with finite element analysis to predict the long-term viscoelastic properties of concrete. Data from these simulations are used to develop constitutive equations for the viscoelastic behavior of the homogenized concrete. The codes in this work are used to virtualize laboratory experiments, to obtain long-term creep data in a faster, cheaper manner. To validate this work, the simulated creep behavior of concrete is compared to 800 d of experimental data that has been extended to 27 y of data using the Time-Temperature superposition (TTS) principal. Excellent agreement between the simulation results and experimental data is seen.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applicability of the Milestones Approach to Deployments of Transportable Nuclear Power Plants (TNPPs)

Transportable nuclear power plants (TNPPs) can provide potential benefits to countries embarking on nuclear programs, offering reduced infrastructure requirements, shorter timeframes for implementation, cost savings and greater deployment flexibility than larger conventional reactors. However, the deployment of a TNPP in a Host State comes with the obligation to establish sufficient regulatory, institutional, and technical infrastructure, which, among others, includes a legal and regulatory framework and a competent regulatory body to implement a State’s safeguards obligations. This paper considers how the unique technical and deployment features of TNPPs may affect the process of preparing for and implementing safeguards in nuclear newcomer countries. Evaluating this issue through the lens of the IAEA’s Milestones Approach, this paper discusses some potential implications arising from the shortening of some milestones phases due to reduced construction or licensing time for TNPPs, and the need for increased cooperation between Host States and Supplier States in preparing for and meeting certain safeguards obligations. These considerations are potentially relevant to various stakeholders: newcomer States considering TNPP deployment; the States and companies that supply such reactors; as well as organizations that support international safeguards capacity building.

Siserman-Gray, Ioana-Cristina↗

Optimizing the physical design and layout of a resilient wind, solar, and storage hybrid power plant

We report as wind and solar technologies improve and their costs decrease, the share of power produced by these sources will increase. As the market penetration increases, these power sources will need to provide grid services, such as dispatchability, in addition to providing energy. One way to reduce variability, provide higher quality power to the grid, and address local grid stability issues is through colocating wind and solar power plants. In addition to operating reliably during normal operating conditions, in scenarios with high penetrations of renewable generation, it is important that these hybrid plants can withstand production disruptions and continue to supply power despite prolonged resource reduction, extreme weather events, or other disruptions. In this paper, we present a methodology to optimize a wind-solar-battery hybrid power plant down to the component level that is resilient against production disruptions and that can continually produce some minimum required power. We introduce the models and assumptions we used to simulate a hybrid power plant as well as the design variable parameterization and specific methods we used to optimize the plant. We demonstrate the performance of our method by comparing a plant optimized for different objectives, generation outage durations, minimum power requirements, and power purchase agreements. Although the plant design is sensitive to model parameters and various other assumptions, our results demonstrate some of the optimal designs that occur in different scenarios and what one should expect when designing a hybrid wind-solar-storage power plant.

14 SOLAR ENERGY↗

Deep reinforcement learning for class imbalance fault diagnosis of equipment in nuclear power plants

In equipment fault diagnosis in nuclear power plants, there may be far more samples in one class (e.g., a health state) than in another class (e.g., a fault state). The distribution of data in each class is highly skewed. Most machine learning algorithms are suitable for balanced training datasets. When faced with imbalanced samples, these algorithms tend to provide good identification for the majority classes and bias for the minority classes. However, the misclassification of minority classes can lead to high costs. To address the above problem, this paper develops a deep reinforcement learning-based diagnosis method that models fault diagnosis as a sequential decision-making process. At each time step, the agent receives the state of the environment represented by the training samples and then takes a diagnosis action guided by a policy. If the action is correct/incorrect, the agent receives a positive/negative reward. The reward for minority classes is higher than that for majority classes. The agent’s goal is to obtain as many cumulative rewards as possible in the process, i.e., to identify the sample as correctly as possible. Six demonstration scenarios are constructed, depending on the selected fault datasets and the designed model structures. Experiments show that the proposed method achieves a higher weighted-averaged F1 score than the classical supervised learning method in most cases of class imbalance. Finally, the proposed method has potential applications in the field of class imbalance fault diagnosis of equipment in nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scaling trends for balance-of-system costs at land-based wind power plants: Opportunities for innovations in foundation and erection

Wind power plant sizes, hub heights, and turbine ratings have increased since 2008 to optimize the cost and performance of wind power; however, the limits of these economies of scale remain unclear. Here, we explore how the costs incurred to install turbines at a wind power plant—the balance-of-system (BOS) costs—scale with turbine rating, hub height, and plant size. We also investigate how these changes in BOS costs influence the levelized cost of energy (LCOE). We show that increasing the plant size from 150 to 400 MW could reduce the BOS costs by 21%. We also show that if the foundation costs decreased by 50%, building a wind power plant with 5-MW turbines (having rotor diameters of 166 m and hub heights of 120 m) could decrease the LCOE by 5%. These results could help inform future BOS cost-reduction opportunities and thereby reduce future capital costs for land-based wind power.

17 WIND ENERGY↗

Energy Storage Sizing and Operation of an Integrated Utility-Scale PV+ESS Power Plant

Integration of an energy storage system (ESS) into a large-scale grid-connected photovoltaic (PV) power plant is highly desirable to improve performance of the system and overcome the stochastic nature of PV power generation. Algorithms to size ESS within an integrated PV and ESS ( PV+ESS) power plant, conventionally, require a large number of high-resolution samples of PV generation. These algorithms are computationally expensive. In this paper, a two-day optimization algorithm that utilizes n-step constant power output dispatch every day from the PV+ESS power plant is proposed to size the ESS. Additionally, an n-step power dispatch every day through the one-year timeframe based optimization of the size of ESS is also performed. The proposed methods are computationally cheaper and provide acceptable accuracy with respect to the conventional sizing methods. The economics identified from the proposed methods are compared with the typical day-ahead hourly dispatch-based power production from the PV+ESS power plant. This comparison has shown similar economic performance showcasing the accuracy of the proposed methods in sizing the ESS. It also shows the potential for operating PV+ESS power plant in n-step constant power generation mode.

Xia, Qian↗

Critical Component/Technology Gap in 21 st Century Power Plant Gasification Based Polygeneration: Advanced Ceramic Membranes/Modules for Ultra Efficient Hydrogen (H 2 ) Production/Carbon Dioxide (CO 2 ) Capture for Coal-Based Polygeneration

The 21 st Century Power Plant Gasification Based Polygeneration power plant layout is a relatively straightforward retrofit of well-established ammonia synthesis technology to the baseline IGCC process and envisions co-production of power and chemicals from coal in the context of carbon capture. A Dual Stage Membrane Process (DSMP) for pre-combustion CO 2 capture in a coal fired IGCC power plant has been demonstrated by Media and Process Technology Inc (MPT) (DE-FE0013064) in bench-scale live gas testing at the NCCC. This work, however, highlighted the importance of permeate purge capability to deliver deep H 2 recovery at moderate pressures and high carbon capture performance. Further, in the area of warm gas processing, a permeate purgeable membrane support for a wide range of inorganic high-performance membrane materials (CMS, Pd-alloy, zeolite, ZIF, graphene, etc.) was not available and hence had been a common and significant barrier to their commercialization. Hence, the Critical Technology Gap to implementing the DSMP in the Polygeneration power plant and more broadly in advanced warm gas separation applications was the inability to permeate purge the membranes coupled with the lack of the availability of a high packing density scalable package design. To overcome this Critical Technology Gap, in this project, the primary objective was the development of a permeate purgeable full ceramic support for these high-performance inorganic membranes and the complementary high packing density housing. Our goal and approach were to extend our “candle filter” design to a “dual end open” package to enable permeate purge and scalability. Microporous ceramic membranes have been proven to be a low cost, stable material for high temperature applications under harsh environment. They are the leading support choice of researchers in advanced inorganic membrane development in applications such as pre-combustion CO 2 capture. The new 2nd Generation “dual end open” bundle developed in this project is a universal support for these existing and emerging inorganic membrane technologies that up to now have lacked a pathway out of the laboratory. The full ceramic permeate purgeable support represents a transformational technology and opens the door to commercialization of these advanced membrane materials in a wide array of mega scale commercial applications in gas (and liquid) processing under aggressive conditions not suited to conventional polymeric membranes.

01 COAL, LIGNITE, AND PEAT↗

Life cycle assessment of novel heat exchanger for dry cooling of power plants based on encapsulated phase change materials

Cooling systems in power plants account for approximately 40% of total freshwater withdrawals in the U.S. Due to dwindling access to freshwater resources worldwide, continued operation of wet cooling systems poses a significant engineering challenge. To reduce water consumption, a novel air-cooled heat exchanger has been developed using encapsulated phase change material (EPCM) for dry cooling of power plants. Compared to traditional finned-tube air-cooled condensers, this novel EPCM heat exchanger improves the heat transfer coefficient and power plant efficiency while reducing the pressure drop and cooling system cost. Life cycle assessment (LCA) and techno-economic analysis (TEA) are used to evaluate the environmental and economic performance of EPCM heat exchangers from cradle-to-grave and to compare them to wet cooling and traditional air-cooled condensers. A thermodynamic model is developed to predict the EPCM heat exchanger performance for plant-scale operations. Equipment and construction costs for heat exchangers are estimated based on design parameters obtained from the thermodynamic model. Both process-LCA and economic-input–output LCA are used to simulate and test the sensitivity of EPCM alternatives with commercial wet and dry cooling technologies. We investigate options for EPCM end-of-life management upon retiring the heat exchanger and construct a process-based LCA model to estimate a greenhouse gas (GHG) emissions credit for recycling the EPCM. The life cycle GHG emission of the novel dry cooling technology is 1.16 kg CO 2 eq. /MWh compared with the 1.1–4.3 kg CO 2 eq. /MWh reported for commercial dry cooling technologies and consumes 9.5 L/MWh e of water for cradle-to-gate life cycle, which is significantly lower than that of wet cooling systems. The TEA shows many advantages of EPCM cooling technology over the state-of-art dry cooling solutions. Overall, the EPCM heat exchanger provides a better alternative compared to existing dry cooling and wet cooling technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling The Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

Ohio University (OHIO), West Virginia University (WVU), and American Electric Power (AEP) proposed to study and report on the benefits of 5G wireless cellular technologies for coal-fired power plants. The significant advantages, cost savings, and potential of 5G wireless data communications based sensors promised to usher in a new era of reliable, inexpensive, and powerful embedded systems that had not previously been available for coal-fired power plants. The team built upon existing experience with cellular-based systems, power plant water quality sensing, and high temperature sensors developed during past projects. Principal Investigator Wilhelm had been developing cellular-based sensor data systems with a commercial partner for 10 years, pioneering innovative solar-powered devices that began with 2G technology. The lessons and knowledge gained served as a foundation to demonstrate innovations and potential impacts specific to coal fired power plants enabled by 5G technology, along with integration with existing sensors and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Incorporation of Thermal Hydraulic Models for Thermal Power Dispatch into a PWR Power Plant Simulator

This report describes the development, modeling, and results of a generic pressurized water reactor power plant simulator that incorporates coupled electrical and thermal power dispatch to an industrial process located approximately one kilometer from the nuclear power plant. The simulator is a commercial PWR simulator that has been modified to include thermal power dispatch as described in past milestone reports [ , ]. The commercial PWR simulator is a generic simulator available from GSE SYSTEMS® (Sykesville, MD, USA) that is built using RELAP5-HDTM Real-Time Solution and in-house software developed by GSE Systems. This generic PWR (GPWR) simulator performs real-time simulation of the complete power plant from the reactor neutronics to the electricity generation and distribution. All primary, secondary, and auxiliary systems are modeled including all control logic in order to provide the most accurate representation of actual nuclear power plant (NPP) operation, and the simulator results have been rigorously verified by an actual NPP operating at approximately 1 GWe. This report is a continuation of worked performed in previous years, and supplemental information from previous reports is included in the appendix for reference.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Modeling and Simulation of a Subcritical Coal-Fired Power Plant under Load-Following Conditions

Dynamic models for power plants that capture realistic general process trends and effects of manipulated variables are needed to improve load-following, while minimizing carbon footprint. In this work, a dynamic modeling approach and simulation results for subcritical coal-fired power plant components are presented. These encompass simulation of the dynamics in the fireside, including the effects of fuel, air combustion, and the dynamics of the entire waterside and power generation sections. This model development enables the simulation and analysis of the important short and long-time scale dynamics of components such as heaters, evaporative loop, and power generation units. Furthermore, additional variables in the power generation section are introduced to improve model accuracy, extending the prediction capability of subcritical power plant models and opening new opportunities for research in operator training, optimization, and advanced model-based controller design that are based on these models. The change in process gain for different ramp rates associated with disturbance signals that affect process variables is also explored and a correlation developed. This provides opportunities to study disturbance rejection control implementation and adaptation for scenarios with such variations in ramp rates. The prediction capabilities of selected components are compared to data available in literature, with the obtained root mean squared error ranges that reflect the model performance and quality of predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗