Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarized Light Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

88 records · Page 5

Scanning Tunneling Optical Resonance Microscopy

Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the feedback circuit could respond, then the voltage applied to the piezoelectric tip-height actuator could be measured by use of a lock-in amplifier locked to the modulation (chopping) signal. However, at a high modulation frequency (typically in the kilohertz range or higher), the feedback circuit would be unable to respond. In this case, the photoenhanced portion of the tunneling current could be measured directly. For this purpose, the tunneling current would be passed through a precise resistor and the voltage drop would be measured by use of the lock-in amplifier.

Bailey, Sheila↗

Near-Field Scanning Optical Microscopy of Soft, Biological, or Rough Objects in Aqueous Environment: Challenges and some Remedies to Circumvent

Near-field scanning optical microscopy is an established technique for sub-wavelength spatial resolution in imaging, spectroscopy, material science, surface chemistry, polarimetry, etc. A significant amount of confidence has been established for thin hard specimens in air. However when soft, biological, rough, in aqueous environment object, or a combination is involved, the progress has been slow. The tip-sample mechanical interaction, heat effects to sample, drag effects to the probe, difficulty in controlling tip-sample separation in case of rough objects, light scattering from sample thickness, etc. create problems. Although these problems are not even fully understood, there have been attempts to study them with the aim of performing reliable operations. In this review we describe these attempts. Starting with general problems encountered, various effects like polarization, thermal, and media are covered. The roles of independent tip-sample distance control tools in the relevant situations are then described. Finally progress in fluid cell aspect has been summarized.

Vikram, C. S.↗

Voltage-induced magnetic domain evolution in a phase-change material

Applying voltage to metal–insulator transition (MIT) materials allows electrical actuation of the local electronic phase state. In MIT systems that have the electronic order coupled with the magnetic order, voltage switching of the electronic phase state can also enable the electrical manipulation of magnetic properties. In this work, we utilized x-ray magnetic circular dichroism photoemission electron microscopy (XMCD-PEEM) to investigate the control of magnetic domain configurations in ferromagnetic MIT electrical switches. For applied voltages above a threshold value, the XMCD-PEEM images show that the magnetic domains separate into two distinct regions: one with a high contrast (white/black), indicating well-defined micrometer-scale magnetic domains with a component of their magnetization aligned parallel/antiparallel to the x-ray helicity, and the other with different shades of intermediate contrast (gray). Significant changes in magnetic domain configurations upon voltage biasing were only observed in these gray regions. Furthermore, the voltage-induced magnetic domain separation was found to be bias polarity-dependent, with the gray regions expanding from the opposite sample edge when the applied voltage polarity was reversed. This polarity-dependent electrical control of magnetic domain configurations during the MIT switching opens alternative opportunities in memory applications for magnetic MIT switching materials.

42 ENGINEERING↗

Quantum confining excitons with an electrostatic moiré superlattice

Quantum confining excitons has been a persistent challenge in the pursuit of strong exciton interactions and quantum light generation. Unlike electrons, which can be readily controlled via electric fields, imposing strong nanoscale potentials on excitons to enable quantum confinement has proven challenging. In this study, we utilize piezoelectric force microscopy to image the domain structures of twisted hexagonal boron nitride (h – BN), revealing evidence of strong in-plane electric fields at the domain boundaries. By placing a monolayer MoSe 2 only one to two nanometers away from the twisted h – BN interface, we observe energy splitting of neutral excitons and Fermi polarons by several millielectronvolts at the moiré domain boundaries. By directly correlating local structural and optical properties, we attribute such observations to excitons confined in a nanoscale one-dimensional electrostatic potential created by the strong in-plane electric fields at the moiré domain boundaries. Intriguingly, this 1D quantum confinement results in pronounced polarization anisotropy in the excitons’ reflection and emission, persistent to temperatures as high as ~80 Kelvins. Furthermore, these findings open new avenues for exploring and controlling strongly interacting excitons for classical and quantum optoelectronics.

2-dimensional systems↗

The Structure of the Statocyst of the Freshwater Snail Biomphalaria Glabrata (Pulmonata, Basommatophora)

The structure of the statocyst of the freshwater snail Biomphalaria glabrata has been examined by light and electron microscopy. The two statocysts are located on the dorsal-lateral side of the left and right pedal ganglion. The statocysts are spherical, fluid-filled capsules with a diameter of approximately 60 microns for young and 110 microns for adult snails. The wall of the cyst is composed of large receptor cells and many smaller supporting cells. The receptor cells bear cilia which are evenly distributed on the apical surface. The cilia have the typical 9+2 internal tubule configuration. Striate rootlets originate from the base of the basal body and run downward into the cytoplasm. Side-roots arise from one side of the basal body and a basal foot from the other. For each receptor cell, the basal foot always points to the periphery of the surface, indicating that the receptor cell is non-polarized. The receptor cells contain cytoplasmic organelles such as mitochondria, ribosomes, rough and smooth endoplasmic reticulum, compact Golgi bodies and multivesicular bodies. Supporting cells bearing microvilli are interposed between the receptor cells. The junction complex between the supporting cells and the receptor cells is composed of adherens and septate junctions, while between supporting cells only the adherens junctions are present. The static nerve arises from the lateral side of the cyst and contains axons in which parallel neurotubules and mitochondria are found. The axons arise directly from the base of the receptor cells without synapse. In the cyst lumen there are unattached statoconia. The statoconia have a plate-like or concentric membranous ring structure. Based on the morphology, the function of the statocyst in Biomphalaria is discussed.

Gao, Wenyuan↗

New optical scheme for a polarimetric-based glucose sensor

A new optical scheme to detect glucose concentration in the aqueous humor of the eye is presented. The ultimate aim is to apply this technique in designing a new instrument for, routinely and frequently, noninvasively monitoring blood glucose levels in diabetic patients without contact (no index matching) between the eye and the instrument. The optical scheme exploits the Brewster reflection of circularly polarized light off of the lens of the eye. Theoretically, this reflected linearly polarized light on its way to the detector is expected to rotate its state of polarization, owing to the presence of glucose molecules in the aqueous humor of a patient's eye. An experimental laboratory setup based on this scheme was designed and tested by measuring a range of known concentrations of glucose solutions dissolved in water. (c) 2004 Society of Photo-Optical Instrumentation Engineers.

Evaluation Studies↗

Exploiting universal nonlocal dispersion in optically active materials for spectro-polarimetric computational imaging

Recent years have seen significant advancements in exploring novel light-matter interactions such as hyperbolic dispersion within natural crystals. However, current studies have predominantly concentrated on local optical response of materials characterized by a dielectric tensor without spatial dispersion. Here, we investigate the nonlocal response in optically-active crystals with screw symmetries, revealing their lossless, super-dispersive properties compared to traditional optical response functions. We leverage this universal nonlocal dispersion, i.e. the dispersion of optical rotatory power, to explore a novel spectral de-multiplexing scheme compared to conventional gratings, prisms and metasurfaces. We design and demonstrate an ‘Nonlocal-Cam’ - a camera that exploits nonlocal dispersion through sampling of polarized spectral states and the application of computational spectral reconstruction algorithms. The Nonlocal-Cam captures information in both laboratory and outdoor field experiments which is unavailable to traditional intensity cameras - the spectral texture of polarization. Merging the fields of nonlocal electrodynamics and computational imaging, our work paves the way for exploiting nonlocal optics of optically active materials in a variety of applications, from biological microscopy to physics-driven machine vision and remote sensing.

Wang, Xueji [Purdue Univ., West Lafayette, IN (Uni↗

Homoepitaxial ZnO Film Growth

ZnO films have high potential for many applications, such as surface acoustic wave filters, UV detectors, and light emitting devices due to its structural, electrical, and optical properties. High quality epitaxial films are required for these applications. The Al2O3 substrate is commonly used for ZnO heteroepitaxial growth. Recently, high quality ZnO single crystals are available for grow homoepitaxial films. Epitaxial ZnO films were grown on the two polar surfaces (O-face and Zn-face) of (0001) ZnO single crystal substrates using off-axis magnetron sputtering deposition. As a comparison, films were also deposited on (0001) Al2O3 substrates. It was found that the two polar ZnO surfaces have different photoluminescence (PL) spectrum, surface structure and morphology, which strongly influence the epitaxial film growth. The morphology and structure of homoepitaxial films grown on the ZnO substrates were different from heteroepitaxial films grown on the Al2O3. An interesting result shows that high temperature annealing of ZnO single crystals will improve the surface structure on the O-face surface rather than the opposite surface. The measurements of PL, low-angle incident x-ray diffraction, and atomic force microscopy of ZnO films indicate that the O-terminated surface is better for ZnO epitaxial film growth.

Zhu, Shen↗

LIRA: Probing the Lunar Surface for Resources.

The thermal, compositional and electrical properties of the lunar regolith, such as the triboelectric properties of lunar dust, the volatile content and the thermophysical properties of the polar regolith are essential to understand from a scientific perspective as well as for resource extraction and hazard mitigation. Understanding these properties specifically requires in situ measurement, as these properties are inherent in the ambient environment. With the Lunar In situ Regolith Analyzer (LIRA) we will combine mature surface sensor technologies from previous spacecraft missions (TECP) with new sensors (ClO4- ) and battery capability to achieve a compact in situ analysis package. The surface instrument suite is adapted for lunar conditions from a sensor developed as part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on the 2007 Mars Phoenix mission, as well as supplemental sensors. • The Thermal and Electrical Conductivity Probe (TECP), flown on MECA/Phoenix, which measures heat capacity, thermal conductivity, electrical resistance, and electrical permittivity between needles inserted into the soil. The TECP also measured atmospheric humidity, a capability that will be retained to search for subsurface H2O ice. The Mars TECP weighed 100-gram and by definition was at TRL 9. The lunar version (LIRA) is TRL 4. • The Perchlorate (ClO4) sensor is based on the fluorescence property of perchlorate (Mg, Fe, Na). We added a light source to excite the perchlorate (ClO4) and a photo diode to collect the emission wavelength. A sun-shade over the photo diode blocks out the ambient light during day light hours. The unifying goal of LIRA is to deliver a complete, integrated experiment suite that investigates properties that must be measured in situ, and provides the capability to power the suite at night or in PSRs, as well as a means to simulate aspects of the diurnal transition by delivering an optical pulse to the surface with intensity comparable to sunlight. We describe the scientific context of LIRA, touching on the electrical state of the near-surface environment, the thermal properties of the undisturbed regolith, and the distribution, geochemistry, and mobility of water. We also address the exploration implications of the work, examining hazards and resources in the context of strategic knowledge gaps (SKGs).

Heather Smith↗

Metrological and Spectral Characterization of the Aspera Flight Optics

Aspera is a NASA's Astrophysics Pioneers mission, led by the University of Arizona. The aim of this mission is to study the presence of hot gasses (T=10^5-10^6 K) in the circumgalactic medium (CGM) and how the flow of these gasses affects galactic formation. One key enabling technology in the Aspera optical system is the use of more efficient UV-reflective optical coatings particularly at around 103.2 nm where the O VI emission line is located . In order to meet radiometric effective area requirements, the Goddard Space Flight Center (GSFC) code 551 Optics Branch applied Al (aluminum) + eLiF (enhanced lithium fluoride) on these optics, where the Al+LiF is annealed at elevated temperature (~250˚C) after the deposition and thus providing an improved version of the Al+LiF used in FUSE . Furthermore, these optics are encapsulated with a thin film of atomic layer deposited MgF2 at the Jet Propulsion Laboratory for enhanced durability . The efficiency and durability of these coatings depends on the quality of the optical surface in terms of cleanliness and roughness. Roughness increases the scatter off the coating and reduces the specular reflectance, and surface contaminants can accommodate moisture and other contaminants, increase scattering, and are weak points in the coating that may affect adhesion and subsequently the longevity of these coatings. Extensive optical metrology is necessary to minimize and quantify the impact of surface roughness and contaminants on optical surfaces. In this proceeding we report the inspection procedure implemented for Aspera optics at GSFC, from initial receiving of the optics to post-coating. Inspection includes Atomic Force Microscopy (AFM), Scanning White Light Interferometry (SWILI), Dark Field Microscopy (DFM), Phase Shifting Interferometry (PSI), and Vacuum ultraviolet (VUV) spectroscopy. Combinations of these techniques are used to inspect flight optics at each of the following steps: i) as-received, pre-cleaning inspection, ii) pre-coating, post-cleaning inspection, and iii) post-coating inspection. The evolution of roughness and other surface inspections such as contaminants are compared between each step to quantify the effect each step has on the flight optics. The final far ultraviolet (FUV) spectral performance of witness samples coated with the flight optics are presented.

Far Ultraviolet (FUV)↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Metasurface‐Based Mueller Matrix Microscope

In conventional optical microscopes, image contrast of objects mainly results from the differences in light intensity and/or color. Muller matrix optical microscopes (MMMs), on the other hand, can provide significantly enhanced image contrast and rich information about objects by analyzing their interactions with polarized light. However, state-of-the-art MMMs are fundamentally limited by bulky and slow polarization state generators and analyzers. Here, the study demonstrates a metasurface-based MMM, i.e., Meta-MMM, which is equipped with a chip-integrated, single-shot metasurface polarization state analyzer (Meta-PSA). The Meta-MMM is featured with high-speed measurement (≈2s per Muller matrix (MM) image), superior operation stability, dual-color operation, and high measurement accuracy (measurement error 1–2%) for MM imaging. The Meta-MMM is applied to nanostructure characterization, surface morphology analysis, and discovering birefringent structures in honeybee wings. As a result, the Meta-MMMs hold the promise to revolutionize various applications from biological imaging, medical diagnosis, and material characterization to industry inspection and space exploration.

36 MATERIALS SCIENCE↗

Surface magnetism in Fe 3 GeTe 2 van der Waals ferromagnet

The surface magnetization of Fe 3 GeTe 2 was examined by low-energy electron microscopy (LEEM) using an off-normal incidence electron beam. We found that the 180o domain walls are of Bloch type. Temperature-dependent LEEM measurements yield a surface magnetization with a surface critical exponent β1 = 0.79±0.02. This result is consistent with surface magnetism in the 3D semi-infinite Heisenberg (β1 = 0.84±0.01) or Ising (β1 = 0.78±0.02) models, which is distinctly different from the bulk exponent (β = 0.34±0.07). Further, the measurements reveal the power of LEEM with a tilted beam to determine magnetic domain structure in quantum materials, without need for the use of spin-polarized electrons. Single crystal diffraction measurements reveal inversion symmetry-breaking weak peaks and yield space group P-6m2. This Fe site defect-derived loss of inversion symmetry enables the formation of skyrmions in this Fe 3 GeTe 2 crystal.

36 MATERIALS SCIENCE↗

Pollen and ovule development in Arabidopsis thaliana under spaceflight conditions

The development of pollen and ovules in Arabidopsis thaliana on the space shuttle 'Endeavour' (STS-54) was investigated. Plants were grown on nutrient agar for 14 days prior to loading into closed plant growth chambers that received light and temperature control inside the Plant Growth Unit flight hardware on the shuttle middeck. After 6 days in spaceflight the plants were retrieved and immediately dissected and processed for light and electron microscope observation. Reproductive development aborted at an early stage. Pistils were collapsed and ovules inside were seen to he empty. No viable pollen was observed from STS-54 plants; young microspores were deformed and empty. At a late stage, the cytoplasm of the pollen contracted and became disorganized, but the pollen wall developed and the exine appeared normal. The tapetum in the flight flowers degenerated at early stages. Ovules from STS-54 flight plants stopped growing and the integuments and nucellus collapsed and degenerated. The megasporocytes appeared abnormal and rarely underwent meiosis. Apparently they enlarged, or occasionally produced a dyad or tetrad, to assume the form of a female gametophyte with the single nucleus located in an egglike cell that lacks a cell wall. Synergids, polar nuclei, and antipodals were not observed. The results demonstrate the types of lesions occurring in plant reproductive material under spaceflight conditions.

STS-54 Shuttle Project↗

Atomic-scale imaging of frequency-dependent phonon anisotropy

Directly visualizing vibrational anisotropy in individual phonon modes is essential for understanding a wide range of intriguing optical, thermal and elastic phenomena in materials. Although conventional optical and diffraction techniques have been used to estimate vibrational anisotropies, they fall short in achieving the spatial and energy resolution necessary to provide detailed information. Here, we introduce a new form of momentum-selective electron energy-loss spectroscopy, which enables the element-resolved imaging of frequency- and symmetry-dependent vibrational anisotropies with atomic resolution. Vibrational anisotropies manifest in different norms of orthogonal atomic displacements, known as thermal ellipsoids. Using the centrosymmetric strontium titanate as a model system, we observed two distinct types of oxygen vibrations with contrasting anisotropies: oblate thermal ellipsoids below 60 meV and prolate ones above 60 meV. In non-centrosymmetric barium titanate, our approach can detect subtle distortions of the oxygen octahedra by observing the unexpected modulation of q-selective signals between apical and equatorial oxygen sites near 55 meV, which originates from reduced crystal symmetry and may also be linked to ferroelectric polarization. These observations are quantitatively supported by theoretical modelling, which demonstrates the reliability of our approach. The measured frequency-dependent vibrational anisotropies shed new light on the dielectric and thermal behaviours governed by acoustic and optical phonons. Furthermore, the ability to visualize phonon eigenvectors at specific crystallographic sites with unprecedented spatial and energy resolution opens new avenues for exploring dielectric, optical, thermal and superconducting properties.

Ferroelectrics and multiferroics↗

Volumetric carrier injection in InGaN quantum well light emitting diodes

InGaN/GaN quantum well (QW) light emitting diodes (LEDs) are essential components of solid-state lighting and displays. However, the efficiency of long wavelength (green to red) devices is inferior to that of blue LEDs. To a large degree, this occurs because the equilibration of injected holes between multiple QWs of the active region is hindered by GaN quantum confinement and polarization barriers. This drawback could be overcome by volumetric hole injection into all QWs through semipolar QWs present on the facets of V-defects that form at threading dislocations in polar GaN-based structures. In this work, we have tested the viability of this injection mechanism and studied its properties by time-resolved and near-field spectroscopy techniques. Here, we have found that indeed the hole injection via the V-defects does take place, the mechanism is fast, and the hole spread from the V-defect is substantial, making this type of injection feasible for efficient long wavelength GaN LEDs.

InGaN/GaN quantum wells↗