Preliminary Assessment of the Importance of Platform-Tendon Coupling in a Tension Leg Platform
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The DIP sub-project of NASA's ATM-X project will be participating in a technical interchange meeting with United Airlines to discuss research goals and objectives for FY23 and beyond.
Not provided.
Explore the source record for details and available documents.
Not provided.
Explore the source record for details and available documents.
Abstract not provided
Zirconium-89 (89Zr) is a long-lived (t1/2 = 78.4 h) positron-emitting isotope that is useful for positron emission tomography (PET) based diagnostic imaging using radiolabeled antibodies. Hydroxamate resin columns are predominantly used for the purification of 89Zr from cyclotron bombarded natY targets dissolved in strong HCl. 89Zr is conventionally eluted from the resin in 1 M oxalic acid (H2C2O4), a complexant that is conducive to follow-on binding of 89Zr through a transchelation process to the deferoxamine siderophore. In the present study, we determined that a lower concentration of H2C2O4 eluent (0.8 M) is adequate to efficiently remove 89Zr from a column containing 100 mg hydroxamate resin. As a result, less buffering agents are needed to be added to the 89Zr product fraction prior to labeling. A simple automated fluidic system prototype has been developed to perform the steps required for 89Zr purification using a hydroxamate resin column (column conditioning in HCl, Y target dissolution, dissolved target solution load onto column, column washes using HCl and water, and 89Zr elution). The system performance was evaluated using several cyclotron bombarded Y targets; 89Zr product fractions demonstrated excellent chemical recoveries from these targets, with 1.0 mL product volumes yielding 89±2% of the column elution peak activity and 84±2% of 89Zr recovered from the target (at EOB). These results compare favorably with previously published 89Zr product volumes and yields, despite the lower concentration of H2C2O4 eluent employed. Transchelation of resulting 89Zr product fractions was performed to assess product quality. The effective specific activity (ESA) ranged between 44(7) and 109(22) TBq·mmole-1, while the bindable metals concentration, a metric introduced for assessing and comparing product purity, ranged between 43(7) and 115(27) nmole·g-1.
Not provided.
The development of a tandem column purification method for the production of high-purity 89Zr is presented. The primary column was a macroporous strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary column, with an internal volume of ~27 µL, was packed with hydroxamate resin. A condition of inverted selectivity was developed, whereby the 89Zr eluent from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89Zr. This approach assures delivery of high purity 89Zr product and assures a 89Zr product that is eluted in a substantially smaller volume than is possible when using the traditionally-employed single hydroxamate resin column method. The tandem column purification process has been implemented into a prototype automated fluidic system. The system is configured with on-line gamma detection so column effluents can be monitored in near-real time. The automated method was tested using seven cyclotron bombarded Y foil targets. It was found that 95.1±1.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction. Furthermore, elution peak analysis of several 89Zr elution profile radiochromatograms made possible the determination of 89Zr recovery as a function of volume; a 89Zr product volume that contains 90% of the mean secondary column elution peak can be obtained in 0.29±0.06 mL (representing 86±5% of the 89Zr activity in the target). This product volume represents a significant increase in isotope product concentration over the predominant method used in the field. In addition to the reduced 89Zr product elution volume, titrations of the 89Zr product with deferoxamine mesylate salt across two preparatory methods resulted in mean effective specific activity (ESA) values of 279 and 340 TBq·mmole-1 and mean bindable metals concentrations ([MB]) of 13.5 and 16.7 nmole·g-1. These ESA and [MB] values infer that the 89Zr product resulting from this tandem column isolation method has the highest purity reported to date.
Not provided.
Not Available
Not Available