Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Platform Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sensory Bias Predicts Postural Stability, Anxiety, and Cognitive Performance in Healthy Adults Walking in Novel Discordant Conditions

We designed a gait training study that presented combinations of visual flow and support surface manipulations to investigate the response of healthy adults to novel discordant sensorimotor conditions. We aimed to determine whether a relationship existed between subjects visual dependence and their scores on a collective measure of anxiety, cognition, and postural stability in a new discordant environment presented at the conclusion of training (Transfer Test). A treadmill was mounted to a motion base platform positioned 2 m behind a large visual screen. Training consisted of three walking sessions, each within a week of the previous visit, that presented four 5-minute exposures to various combinations of support surface and visual scene manipulations, all lateral sinusoids. The conditions were scene translation only, support surface translation only, simultaneous scene and support surface translations in-phase, and simultaneous scene and support surface translations 180 out-of-phase. During the Transfer Test, the trained participants received a 2-minute novel exposure. A visual sinusoidal roll perturbation, with twice the original flow rate, was superimposed on a sinusoidal support surface roll perturbation that was 90 out of phase with the scene. A high correlation existed between normalized torso translation, measured in the scene-only condition at the first visit, and a combined measure of normalized heart rate, stride frequency, and reaction time at the transfer test. Results suggest that visually dependent participants experience decreased postural stability, increased anxiety, and increased reaction times compared to their less visually dependent counterparts when negotiating novel discordant conditions.

Brady, Rachel A.↗

Gait Training Improves Performance in Healthy Adults Exposed to Novel Discordant Conditions

After they return to Earth, astronauts experience sensorimotor disturbances that disrupt their ability to walk. We have previously shown that training with a variety of sensorimotor adaptive challenges enhances the capability of adapting to novel sensorimotor conditions. We are currently developing a sensorimotor adaptability (SA) training program designed to facilitate recovery of function after gravitational transitions. The purpose of this study was to determine whether trained subjects could transfer learned skills from one discordant visuo-proprioceptive environment to another. During three sessions, subjects walked at 2.5 km/h on a treadmill mounted on a motion base platform. Ten subjects trained with a combination of lateral treadmill translation and superimposed sinusoidal lateral optic flow that was presented on a large screen positioned in front of them. Ten controls completed the same training schedule while viewing only the forward optic flow with no visual or physical oscillation. Twenty minutes after the final training session, all subjects completed a 2-minute trial with a novel combination of visual and treadmill roll perturbations not previously experienced during the training (Transfer Test). Compared to the untrained group, participants who received SA training showed faster reaction times and, based on a composite score derived from stride frequency, heart rate, and reaction time, an overall enhanced performance. Our results showed that an SA training program can improve overall walking performance when subjects are exposed to novel incongruent sensory environments. This training has application for both enhancing adaptive responses in astronauts and reducing fall and injury risk in the elderly.

Batson, Crystal D.↗

Training Modalities to Increase Sensorimotor Adaptability

During the acute phase of adaptation to novel gravitational environments, sensorimotor disturbances have the potential to disrupt the ability of astronauts to perform required mission tasks. The goal of our current series of studies is develop a sensorimotor adaptability (SA) training program designed to facilitate recovery of functional capabilities when astronauts transition to different gravitational environments. The project has conducted a series of studies investigating the efficacy of treadmill training combined with a variety of sensory challenges (incongruent visual input, support surface instability) designed to increase adaptability. SA training using a treadmill combined with exposure to altered visual input was effective in producing increased adaptability in a more complex over-ground ambulatory task on an obstacle course. This confirms that for a complex task like walking, treadmill training contains enough of the critical features of overground walking to be an effective training modality. SA training can be optimized by using a periodized training schedule. Test sessions that each contain short-duration exposures to multiple perturbation stimuli allows subjects to acquire a greater ability to rapidly reorganize appropriate response strategies when encountering a novel sensory environment. Using a treadmill mounted on top of a six degree-of-freedom motion base platform we investigated locomotor training responses produced by subjects introduced to a dynamic walking surface combined with alterations in visual flow. Subjects who received this training had improved locomotor performance and faster reaction times when exposed to the novel sensory stimuli compared to control subjects. Results also demonstrate that individual sensory biases (i.e. increased visual dependency) can predict adaptive responses to novel sensory environments suggesting that individual training prescription can be developed to enhance adaptability. These data indicate that SA training can be effectively integrated with treadmill exercise and optimized to provide a unique system that combines multiple training requirements in a single countermeasure system. Learning Objectives: The development of a new countermeasure approach that enhances sensorimotor adaptability will be discussed.

Bloomberg, J. J.↗

Spacecraft Alignment Determination and Control for Dual Spacecraft Precision Formation Flying

Many proposed formation flying missions seek to advance the state of the art in spacecraft science imaging by utilizing dual-spacecraft precision formation flying (PFF) to enable a 'virtual' telescope (VT). Using precision dual-spacecraft alignment, very long focal lengths can be achieved by locating the optics on one spacecraft and the detector on the other. Proposed science missions include astrophysics concepts for X-ray imaging and exo-planet observation with large spacecraft separations (1000 km to 80,000 km), and heliophysics concepts for X-ray or extreme ultra-violet (EUV) imaging or solar coronagraphs with smaller separations (50m - 500m). These proposed missions require advances in guidance, navigation, and control (GN&C) for PFF to enable high resolution science imaging. For many applications, the dual-spacecraft dynamics are coupled through the GN&C system when the relative ranging and position alignment sensor components are not co-located with their respective spacecraft mass centers. We develop a model-based PFF system design approach for the VT application, considering the coupling inherent in precision dual-spacecraft inertial alignment. These systems employ a variety of GN&C sensors and actuators, including laser-based alignment and ranging systems, camera-based imaging sensors, inertial measurement units (IMU), as well as microthruster systems and image motion compensation platforms. Results of a GN&C performance assessment reveal how data from relative position sensors can be employed in a Kalman filter framework to significantly improve alignment estimation performance. The assessment provides a comparison of two different GN&C formation flying architectures, illustrating the performance trades inherent in the choice of PFF system architecture in the VT application.

Formation Flying↗

Hazard Perception & Avoidance (HPA), Assured Vehicle Automation 1 Simulation (AVA-1h) Results Outbrief

In late 2022, the Human Autonomy Teaming Lab (NASA Ames Research Center) conducted a manned, human-in-the-loop (HITL) simulation. This HITL was the lab’s second Hazard Perception and Avoidance (HPA) technical work under NASA’s Advanced Air Mobility (AAM), Automated Flight and Contingency Management (AFCM) Sub-Project. The goals were to assess detect and avoid technology for manned, electric vertical takeoff and landing (eVTOL) aircraft. This simulation tested Resolution Advisory (RA) responses and return-to-course (RTC) maneuvers for the second version of the Airborne Collision Avoidance System’s (ACAS) rotary-wing (Xr) variant. This was conducted at the center's Vertical Motion Simulator (VMS), on a motion-based platform, and was configured to fly eVTOL aircraft while maneuvering for intruding traffic. Variables for this study included ACAS Xr modes (i.e., TA/RA and DAA) and phases of flight (i.e., Cruise, Hover, and Approach). The data collected included response times, losses of well clear, and pilots' noncompliances to alerts and guidance as well as subjective ratings like acceptability and perceived workload. Additional details and future anticipations are also discussed.

ACAS Xr↗

Human Stability While Exercising on a VIS Device in Zero Gravity

BACKGROUND: A Vibration Isolation and Stabilization (VIS) system is being designed for use with the European Enhanced Exploration Exercise Device (E4D) [1]. The exercise bar is attached to cables that extend and retract through openings in the E4D platform, which the subject stands on while exercising. Since the E4D is mounted on a moving VIS device, the whole system moves under the subject’s feet. While tension in the cables does help stabilize a crew member in 0g by bracing him or her against the moving platform, flexible cables do not offer full support against falling. This raises the question of whether various exercises that are successfully performed in 1g on a stationary device can be performed without losing balance in 0g on a moving device. Quantifying stability conditions and establishing stability requirements for exercise countermeasure systems is a long-standing challenge and this work helped to inform this specific need for integrated E4D/VIS flight project development. METHODS AND RESULTS: A simplified stability analysis can be attempted based on platform accelerations generated by the VIS device simulation. In this type of analysis, the subject is conceived as standing on the platform in 0g while being held down to it by the tension in the cables. If the sideways acceleration of the platform is such that the cables cannot generate a sufficient moment relative to, e.g., the heels or the toes of the subject to overcome the tipping moment from the inertial forces on the accelerated subject’s body, the subject becomes unstable. This approach, which we refer to as the ‘static’ approximation, indicated failure of all the exercises that were considered in the comprehensive VIS analysis of the E4D. It was realized, however, that platform accelerations are not externally imposed but are themselves induced by the motion of the subject’s body during exercise, and a model calculation confirmed that this drastically altered the tipping moment on the subject, with the potential to even switch the direction in which the body would tip over. This made it imperative to consider in a coupled manner both the motion of the exercising subject’s body and the induced VIS platform motion while considering stability. The coupled dynamics requirement was met by the VIS simulation incorporating time-dependent human mass properties atop the platform and driven by the inertial forces from the prescribed subject motion relative to the platform based on motion-capture recorded human trajectories in 1g on a stationary E4D [2]. To analyze simulation results, a stability criterion was also needed. We do not know how to account for the human ‘control system’ that would take visual and vestibular cues as inputs as the platform moves in 0g. We thus chose to follow an approach we had previously used to analyze the dynamic feasibility of performing a task in lunar gravity along the human body trajectory recorded in 1g [3]. In this approach, one analyzes the center of pressure (COP) between the shoes and the ground (or platform) and checks if the COP remains within the convex hull of the footprints on the ground (or platform), commonly referred to as base of support (BOS). Since pressure is vertical and, in the absence of foot restraints, positive, the COP going outside the BOS indicates that the trajectory recorded in 1g is not dynamically feasible in microgravity and/or on the moving platform of the device. The outcome of the COP-based analysis was that some of the key exercises, especially the deadlift and the back squat exercises, were found to be dynamically feasible for at least some number of the exercise cycles, this number increasing with the cable tension. While this type of stability analysis does not account for the likely alteration of the exercise trajectory from its 1g form in space, it does show that there exist at least some realistic trajectories that pass the dynamic feasibility criterion. This adds confidence that, with further adjustment by the subject of the exercise form in 0g on a moving device, a number of exercises can be performed without losing balance.

D Frenkel↗

Task decomposition for a multilimbed robot to work in reachable but unorientable space

Robot manipulators installed on legged mobile platforms are suggested for enlarging robot workspace. To plan the motion of such a system, the arm-platform motion coordination problem is raised, and a task decomposition is proposed to solve the problem. A given task described by the destination position and orientation of the end effector is decomposed into subtasks for arm manipulation and for platform configuration, respectively. The former is defined as the end-effector position and orientation with respect to the platform, and the latter as the platform position and orientation in the base coordinates. Three approaches are proposed for the task decomposition. The approaches are also evaluated in terms of the displacements, from which an optimal approach can be selected.

Su, Chau↗

Simulation of cooperating robot manipulators on a mobile platform

The dynamic equations of motion are presented for two or more cooperating manipulators on a freely moving mobile platform. The system of cooperating robot manipulators forms a closed kinematic chain where the force of interaction must be included in the formulation of robot and platform dynamics. The formulation includes the full dynamic interactions from arms to platform and arm tip to arm tip, and the possible translation and rotation of the platform. The equations of motion are shown to be identical in structure to the fixed-platform cooperative manipulator dynamics. The number of DOFs of the system is sufficiently large to make recursive dynamic calculation methods potentially more efficient than closed-form solutions. A complete simulation with two 6-DOF manipulators of a free-floating platform is presented along a with a multiple-arm controller to position the common load.

Murphy, Stephen H.↗

Modeling and simulation of a Stewart platform type parallel structure robot

The kinematics and dynamics of a Stewart Platform type parallel structure robot (NASA's Dynamic Docking Test System) were modeled using the method of kinematic influence coefficients (KIC) and isomorphic transformations of system dependence from one set of generalized coordinates to another. By specifying the end-effector (platform) time trajectory, the required generalized input forces which would theoretically yield the desired motion were determined. It was found that the relationship between the platform motion and the actuators motion was nonlinear. In addition, the contribution to the total generalized forces, required at the actuators, from the acceleration related terms were found to be more significant than the velocity related terms. Hence, the curve representing the total required actuator force generally resembled the curve for the acceleration related force. Another observation revealed that the acceleration related effective inertia matrix I sub dd had the tendency to decouple, with the elements on the main diagonal of I sub dd being larger than the off-diagonal elements, while the velocity related inertia power array P sub ddd did not show such tendency. This tendency results in the acceleration related force curve of a given actuator resembling the acceleration profile of that particular actuator. Furthermore, it was indicated that the effective inertia matrix for the legs is more decoupled than that for the platform. These observations provide essential information for further research to develop an effective control strategy for real-time control of the Dynamic Docking Test System.

Lim, Gee Kwang↗

Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic measurements during hardware motion and contact. While performing dynamic testing of an active docking system, researchers found that the data from the motion platform, test hardware and two external measurement systems exhibited frame offsets and rotational errors. While the errors were relatively small when considering the motion scale overall, they substantially exceeded the individual accuracies for each component. After evaluating both the static and dynamic measurements, researchers found that the static measurements introduced significantly more error into the system than the dynamic measurements even though, in theory, the static measurement errors should be smaller than the dynamic. In several cases, the magnitude of the errors varied widely for the static measurements. Upon further investigation, researchers found the larger errors to be a consequence of hardware alignment issues, frame location and measurement technique whereas the smaller errors were dependent on the number of measurement points. This paper details and quantifies the individual and cumulative errors of the docking system and describes methods for reducing the overall measurement error. The overall quality of the dynamic docking tests for flight hardware verification was improved by implementing these error reductions.

Winnitoy, Susan↗

Estimating Distances To Objects From Motion In Images

In developmental method of estimating distances between moving platform and nearby stationary objects, positions of objects relative to moving platform deduced from apparent motions of those objects in images generated by video camera affixed to platform. Estimates enhanced by use of extended Kalman filter. Developed for use in controlling military helicopters in low-altitude evasive maneuvers, also potentially applicable in robotics and in autonomous navigation of vehicles in general.

Sridhar, B.↗

Simulation of cooperating robot manipulators on a mobile platform

The dynamic equations of motion for two manipulators holding a common object on a freely moving mobile platform are developed. The full dynamic interactions from arms to platform and arm-tip to arm-tip are included in the formulation. The development of the closed chain dynamics allows for the use of any solution for the open topological tree of base and manipulator links. In particular, because the system has 18 degrees of freedom, recursive solutions for the dynamic simulation become more promising for efficient calculations of the motion. Simulation of the system is accomplished through a MATLAB program, and the response is visualized graphically using the SILMA Cimstation.

Murphy, Steve H.↗

Adjusting a Full Body Model to Mitigate Inverse Kinematics Artifacts in Opensim

BACKGROUND: In support of Vibration Isolation and Stabilization (VIS) system development for Human Health Countermeasures (HHC) exercise systems in space, such as the European Enhanced Exploration Exercise Device (E4D) [1], dynamic quantities required to model the response of a proposed VIS while considering the effect of VIS motion on the forces between the human and VIS platform were obtained using motion capture data [2]. On occasion, large-amplitude oscillatory spikes were found in the subject’s linear and angular momentum derivatives, affecting analyses that depend on forces and moments derived from motion capture. The purpose of this investigation was to identify causes of these artifacts and techniques for their resolution. METHODS AND RESULTS: To obtain the required human dynamic quantities to drive the VIS simulation, motion capture data was collected containing recorded trajectories of passive retroreflective markers on body landmarks of an exercising subject. Since the full body Rajagopal model [3] was originally used to enhance gait analysis, upper body joints did not require large Ranges of Motion (ROM). We thus modified the Rajagopal model [4, 5] to allow it to be used for upper body intensive exercises like those common to the E4D. OpenSim Inverse Kinematics (IK) [6] was performed using these scaled subject models to generate the joint angles throughout the exercise while minimizing marker error. At times, the arms were observed to ‘snap’ from one configuration to another, causing spike artifacts. Following IK, a custom OpenSim plugin [7] was used to determine the required dynamic quantities including the rates of change of the linear and angular momenta of the human. Since motion capture is recorded at a larger time step than required by the VIS simulation, the human center of mass location was fit with splines and a second derivative taken to obtain the momentum derivative, allowing the VIS simulation to maintain conservation of momentum when appropriate. In a few cases during this stage, artifacts much larger than the expected noise of the second derivatives were introduced. Investigation of cases containing artifacts revealed several modifications that could be made to the OpenSim model to improve IK results. Since OpenSim models use Euler angles and rotation sequences, ‘gimbal lock’ would be encountered in the arms when raised 90 degrees to the side (e.g., T-pose, some hang clean exercise, etc.). This was resolved by reorienting the horizontal axes at the shoulder joint by 45 degrees, placing ‘gimbal lock’ outside common arm ROM, with the arm ROMs adjusted following this change. Elbow and wrist ROMs could also be adjusted to allow realistic motion while at the same time limiting the likelihood of unrealistic orientations. On occasion, the arms flipped backwards when raised above the head. This was prevented by using medial elbow markers in scaling and IK. When medial markers were not available, the acromial joint location in the unscaled model was shifted before model scaling to better align the arm with available markers. Lastly, artifacts which became apparent after taking the second derivatives of spline-fit data were found to occur in cases when the pelvis rotation limit prevented the full range of motion of an exercise. These issues were resolved by unclamping the pelvis rotation limit. Through this investigation, an understanding of conditions leading to IK artifacts was acquired allowing the automation of artifact detection. These artifact detection and mitigation techniques can be applied toward modeling of upper body motions in aerospace and other fields for improved IK results.

C A Bell↗

Device for installing rocket engines

A device for installing rocket engines is reported that is supported at a cant relative to vertical by an axially extensible, tiltable pedestal. A lifting platform supports the rocket engine at its thrust chamber exit, including a mount having a concentric base characterized by a concave bearing surface, a plurality of uniformly spaced legs extended radially from the base, and an annular receiver coaxially aligned with the base and affixed to the distal ends of said legs for receiving the thrust chamber exit. The lifting platform rests on a seat concentrically related to the pedestal and affixed to an extended end portion thereof having a convex bearing surface mated in sliding engagement with the concave bearing surface of the annular base for accommodating a rocking motion of the platform.

George, T. R., Jr.↗

Design of a dynamic test platform for autonomous robot vision systems

The concept and design of a dynamic test platform for development and evluation of a robot vision system is discussed. The platform is to serve as a diagnostic and developmental tool for future work with the RPI Mars Rover's multi laser/multi detector vision system. The platform allows testing of the vision system while its attitude is varied, statically or periodically. The vision system is mounted on the test platform. It can then be subjected to a wide variety of simulated can thus be examined in a controlled, quantitative fashion. Defining and modeling Rover motions and designing the platform to emulate these motions are also discussed. Individual aspects of the design process are treated separately, as structural, driving linkages, and motors and transmissions.

Rich, G. C.↗

Superconducting gravity gradiometer and a test of inverse square law

The equivalence principle prohibits the distinction of gravity from acceleration by a local measurement. However, by making a differential measurement of acceleration over a baseline, platform accelerations can be cancelled and gravity gradients detected. In an in-line superconducting gravity gradiometer, this differencing is accomplished with two spring-mass accelerometers in which the proof masses are confined to motion in a single degree of freedom and are coupled together by superconducting circuits. Platform motions appear as common mode accelerations and are cancelled by adjusting the ratio of two persistent currents in the sensing circuit. The sensing circuit is connected to a commercial SQUID amplifier to sense changes in the persistent currents generated by differential accelerations, i.e., gravity gradients. A three-axis gravity gradiometer is formed by mounting six accelerometers on the faces of a precision cube, with the accelerometers on opposite faces of the cube forming one of three in-line gradiometers. A dedicated satellite mission for mapping the earth's gravity field is an important one. Additional scientific goals are a test of the inverse square law to a part in 10(exp 10) at 100 km, and a test of the Lense-Thirring effect by detecting the relativistic gravity magnetic terms in the gravity gradient tensor for the earth.

Moody, M. V.↗