Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plastic scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Terrestrial Gamma‐Ray Flash Following Intense Negative Return Stroke Observed With BIMAP‐3D

We report ground-based observations of a terrestrial gamma-ray flash (TGF) associated with a strong negative cloud-to-ground lightning strike (-CG) which occurred near Los Alamos National Laboratory (LANL) in New Mexico, USA. Gamma photons were detected by the Terrestrial High-energy Observations of Radiation (THOR) instrument, developed at the University of California, Santa Cruz, which has been hosted at LANL since 2022. Simultaneous measurements were also made with the 3-Dimensional Broadband Interferometric Mapping and Polarization (BIMAP-3D) system, which includes 3D lightning mapping, two fast antennas, and an additional plastic scintillator. Additional field change waveforms were obtained from the Earth Networks Total Lightning Network (ENTLN). The lightning initiated about 1 km above the ground, leading to a powerful -CG with an ENTLN peak current of −237 kA and bipolar field change matching the recently described “energetic compact stroke” (ECS) shape. The TGF was then observed ∼35 µs after the start of the return stroke. We also observe an electric field pulse likely produced by the TGF either in isolation or by coupling to the lightning channel. Based on modeling of the radiated electric field and photon propagation through the atmosphere we infer that the TGF source was on the order of 1⁢0 17 photons. This TGF and associated lightning are extremely similar to some recently reported ECS TGFs in coastal Japan in winter, but we report the first observation of this phenomenon outside of Japan in a different climate, terrain, and season.

58 GEOSCIENCES↗

Measurement of the axial vector form factor from antineutrino–proton scattering

Scattering of high energy particles from nucleons probes their structure, as was done in the experiments that established the non-zero size of the proton using electron beams. The use of charged leptons as scattering probes enables measuring the distribution of electric charges, which is encoded in the vector form factors of the nucleon. Scattering weakly interacting neutrinos gives the opportunity to measure both vector and axial vector form factors of the nucleon, providing an additional, complementary probe of their structure. The nucleon transition axial form factor, F A , can be measured from neutrino scattering from free nucleons, ν μ n → μ – p and ν¯ μ p → μ + n , as a function of the negative four-momentum transfer squared (Q 2 ). Up to now, FA(Q 2 ) has been extracted from the bound nucleons in neutrino–deuterium scattering, which requires uncertain nuclear corrections. Here we report the first high-statistics measurement, to our knowledge, of the ν¯ μ p → μ + n cross-section from the hydrogen atom, using the plastic scintillator target of the MINERvA experiment, extracting F A from free proton targets and measuring the nucleon axial charge radius, r A , to be 0.73 ± 0.17 fm. The antineutrino–hydrogen scattering presented here can access the axial form factor without the need for nuclear theory corrections, and enables direct comparisons with the increasingly precise lattice quantum chromodynamics computations. Finally, the tools developed for this analysis and the result presented are substantial advancements in our capabilities to understand the nucleon structure in the weak sector, and also help the current and future neutrino oscillation experiments to better constrain neutrino interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermonuclear neutron emission from a sheared-flow stabilized Z-pinch

We report the fusion Z-pinch experiment (FuZE) is a sheared-flow stabilized Z-pinch designed to study the effects of flow stabilization on deuterium plasmas with densities and temperatures high enough to drive nuclear fusion reactions. Results from FuZE show high pinch currents and neutron emission durations thousands of times longer than instability growth times. While these results are consistent with thermonuclear neutron emission, energetically resolved neutron measurements are a stronger constraint on the origin of the fusion production. This stems from the strong anisotropy in energy created in beam-target fusion, compared to the relatively isotropic emission in thermonuclear fusion. In dense Z-pinch plasmas, a potential and undesirable cause of beam-target fusion reactions is the presence of fast-growing, “sausage” instabilities. This work introduces a new method for characterizing beam instabilities by recording individual neutron interactions in plastic scintillator detectors positioned at two different angles around the device chamber. Histograms of the pulse-integral spectra from the two locations are compared using detailed Monte Carlo simulations. These models infer the deuteron beam energy based on differences in the measured neutron spectra at the two angles, thereby discriminating beam-target from thermonuclear production. An analysis of neutron emission profiles from FuZE precludes the presence of deuteron beams with energies greater than 4.65 keV with a statistical uncertainty of 4.15 keV and a systematic uncertainty of 0.53 keV. This analysis demonstrates that axial, beam-target fusion reactions are not the dominant source of neutron emission from FuZE. These data are promising for scaling FuZE up to fusion reactor conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and simulation of a muon detector to characterize geological overburden

This study presents the design, construction, and simulation of a mobile muon detector tailored for geological overburden characterization. The detector employs plastic scintillator paddles with silicon photomultipliers (SiPMs) and a QuarkNet data acquisition system, offering a portable solution suitable for remote field deployment. The simulator’s modular aluminum frame allows for adjustable geometry and directional sensitivity, while its battery system supports over a week of autonomous operation. Preliminary experimental tests confirmed that its muon flux measurements were consistent with theoretical expectations. A comprehensive simulation framework using Geant4 and CORSIKA was developed to model detector response and overburden effects. Analytical and Monte Carlo methods were used to assess quadrant resolution and infer muon directionality. This work lays the foundation for future overburden mapping and supports the development of reconstruction algorithms for geological applications.

72 - PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved measurement of neutron energy isotropy in a sheared-flow-stabilized Z pinch

Previous measurements of neutron energy using fast plastic scintillators while operating the Fusion Z Pinch Experiment (FuZE) constrained the energy of any yield-producing deuteron beams to less than 4.65 keV. FuZE has since been operated at increasingly higher input power, resulting in increased plasma current and larger fusion neutron yields. A detailed experimental study of the neutron energy isotropy in these regimes applies more stringent limits to possible contributions from beam-target fusion. The FuZE device operated at -25 kV charge voltage has resulted in average plasma currents of 370 kA and D–D fusion neutron yields of $4\times10^7 \pm 4\times10^6$ neutrons per discharge. Measurements of the neutron energy isotropy under these operating conditions demonstrates the energy of deuteron beams is less than $7.4 \pm 5.6^\mathrm{(stat)} \pm 3.7^\mathrm{(syst)}$ keV. Characterization of the detector response has reduced the number of free parameters in the fit of the neutron energy distribution, improving the confidence in the forward-fit method. Gamma backgrounds have been measured and the impact of these contributions on the isotropy results have been studied. Additionally, a time dependent measurement of the isotropy has been resolved for the first time, indicating increases to possible deuteron beam energies at late times. This suggests the possible growth of m = 0 instabilities at the end of the main radiation event but confirms that the majority of the neutron production exhibits isotropy consistent with thermonuclear origin.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The MURAVES muon telescope: a low power consumption muon tracker for muon radiography applications

Muon Radiography or muography is based on the measurement of the absorption or scattering of cosmic muons, as they pass through the interior of large scale bodies, In particular, absorption muography has been applied to investigate the presence of hidden cavities inside the pyramids or underground, as well as the interior of volcanoes’ edifices. The MURAVES project has the challenging aim of investigating the density distribution inside the summit of Mt. Vesuvius. The information, together with that coming from gravimetric measurements, is useful as input to models, to predict how an eruption may develop. The MURAVES apparatus is a robust and low power consumption muon telescope consisting of an array of three identical and independent muon trackers, which provide in a modular way a total sensitive area of three square meters. Each tracker consists of four doublets of planes of plastic scintillator bars with orthogonal orientation, optically coupled to Silicon photomultipliers for the readout of the signal. The muon telescope has been installed on the slope of the volcano and has collected a first set of data, which are being analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the wavelength-shifting fiber upgrade for the Mu2e cosmic-ray veto detector

The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AugerPrime surface detector electronics

Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Design and implementation of the cosmic ray tagger system for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system (∼ 1100 m 2 ), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Above-threshold ionization at laser intensity greater than 10 20 W / cm 2

Here we present experimental observation of above-threshold ionization (ATI) electrons produced by ionization of the neon K shell in a laser field where intensity exceeds 10 20 W/cm 2 . An array of plastic scintillating calorimeter detectors was used to measure the high-energy electrons at four angles in the laser forward direction. Coarse energy resolution was obtained using aluminum filters of several thicknesses to block lower-energy electrons. A threshold intensity around 2×10 20 W/cm 2 is observed for production of energetic ATI electrons in the laser forward direction, with maximum electron energy exceeding 10 MeV. L-shell electrons with energies <1.4 MeV are scattered farther forward along the laser direction than expected. We present comparisons of the measured total electron energies to the predictions of Monte Carlo models employing the ADK-PPT ionization model and the Augst barrier suppression ionization model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Levels in 125 Cd populated by the β decay of 125 m Ag and 125 Ag

Here, the β decay of 125 m, 125 Ag into levels in 125 Cd was investigated at the Holifield Radioactive Ion Beam Facility (HRIBF). Uranium-238 targets were bombarded with 50-MeV protons with an intensity of 15 μ A, and the induced fission products were mass separated and deposited on a moving tape in the center of the VANDLE array consisting of γ detectors and plastic scintillators. A partial decay scheme has been assigned for both β decay of the (9/2 + ) ground state of 125 Ag and its low-lying (1/2 - ) isomer, with the energy of the low-lying (11/2 - ) isomeric state in 125 Cd assigned as 188.5 keV. In addition, β -delayed neutron emission probabilities were also determined to be 1.2(2)% for the (9/2 + ) 125 Ag ground state and 4.6(10)% for the (1/2 - ) isomer, which are substantially lower than the previously reported value.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{beta}- and {gamma}-spectroscopy study of {sup 119}Pd and {sup 119}Ag

Neutron-rich Pd-119 nuclei were produced in fission of natural uranium, induced by 25-MeV protons. Fission fragments swiftly extracted with the Ion Guide Isotope Separation On-Line method were mass separated using a dipole magnet and a Penning trap, providing mono-isotopic samples of Pd-119. Their beta(-) decay was measured with gamma gamma- and beta gamma-spectroscopy methods using low-energy germanium detectors and a thin plastic scintillator. Two distinct nuclear-level structures were observed in Ag-119, based on the 1/2(-) and 7/2(+) isomers reported previously. The beta(-)decay work was complemented by a prompt-gamma study of levels in Ag-119 populated in spontaneous fission of (252)cf, performed using the Gammasphere array of germanium detectors. Contrary to previous suggestions, our data show that the 1/2(-) isomer is located below the 7/2(+) isomer and is proposed as a new ground state of Ag-119 with the 7/2(+) isomer excitation energy determined to be 33.4 keV. Our data indicate that there are two beta unstable isomers in Pd-119, a proposed ground state of Pd-119 with tentative spin 1/2(-) or 3/2(+) and a half-life of 0.88 s and the other one about 350 keV above, having spin (11/2(-)) and a half-life of 0.85 s. The higher-energy isomer probably decays to the 1/2(-) or 3/2(+) ground state via a gamma cascade comprising 18.7-219.8-X-keV transitions. The unobserved isomeric transition with energy X approximate to 100 keV probably has an E3 multipolarity. Its hindrance factor is significantly lower than for analogous E3 isomeric transitions in lighter Pd isotopes, suggesting an oblate deformation of levels in Pd-119. Oblate configurations in Ag-119 are discussed also.

Kurpeta, J↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗