88 records · Page 5

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-dimensional Child–Langmuir law for any diode geometry

While prior theoretical studies of multi-dimensional space-charge limited current (SCLC) assumed emission from a small patch on infinite electrodes, none have considered emission from an entire finite electrode. In this paper, we apply variational calculus (VC) and conformal mapping, which have previously been used to derive analytic solutions for SCLC density (SCLCD) for nonplanar one-dimensional geometries, to obtain mathematical relationships for any multi-dimensional macroscopic diode with finite cathode and anode. We first derive a universal mathematical relationship between space-charge limited potential and vacuum potential for any diode and apply this technique to determine SCLCD for an eccentric spherical diode. We then apply VC and the Schwartz–Christoffel transformation to derive an exact equation for SCLCD in a general two-dimensional planar geometry with emission from a finite emitter. Particle-in-cell simulations using VSim agreed within 4%–13% for a range of ratios of emitter width to gap distance using the thinnest electrodes practical for the memory constraints of our hardware, with the difference partially attributed to the theory's assumption of infinitesimally thin electrodes. After generalizing this approach to determine SCLCD for any orthogonal diode as a function of only the vacuum capacitance and vacuum potential, we derive an analytical formulation of the three-dimensional Child–Langmuir law for finite parallel rectangular and disk geometries. These results demonstrate the utility for calculating SCLCD for any diode geometry using vacuum capacitance and vacuum potential, which are readily obtainable for many diode geometries, to guide experiment and simulation development.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep level study of chlorine-based dry etched β-Ga 2 O 3

Chlorine-based gases are used for the reactive ion etching (RIE) of β-Ga 2 O 3 . However, the effects of Cl-plasma on the electronic properties of β-Ga 2 O 3 are not known. In order to shed light on this topic, we carried out an experimental and theoretical study on β-Ga 2 O 3 epilayers treated with Cl 2 /Ar or BCl 3 /Ar plasma. We found four traps in the 0.2–0.8 eV energy range below the conduction band edge (EC). Two of these, located at E C -0.24 eV and E C -0.28 eV, arise only when the epilayers are treated with BCl 3 /Ar. While the involvement of Cl in their microscopic structure is not discarded, the possibility that these two levels might have an intrinsic nature seems more plausible. Our findings might explain the reported effects on the Schottky barrier diodes of β-Ga 2 O 3 when RIE is employed during processing.

36 MATERIALS SCIENCE↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Quench Protection Study of Superconducting Magnets for the Materials Plasma Exposure Experiment

To advance the understanding of plasma material interactions, the Material Plasma Exposure eXperiment (MPEX) is a new linear plasma device that will generate and deliver plasma relevant to future fusion reactor divertors. The operation of MPEX is planned to be steady-state in order to facilitate high fluence exposures of plasma facing materials and components. The desire for steady-state operation along with the magnetic field requires the utilization of superconducting coils. The superconducting magnet system for MPEX has been developed. The baseline model has six superconducting magnet and one room-temperature magnet subsystems. In order to protect multiple superconducting magnet systems, quench analysis was carried out to determine the best protection approach for each magnet type. Because the mutual inductance accounts for approximately 35% of the stored energy in the entire system, this must be considered when determining the peak voltages and temperatures during a quench. Two approaches for passive quench protection are considered: (1) self-protecting magnets and (2) use of diodes to sub-divide the coils. For both approaches, active quench detection will be used to ensure all coils are de-energized in the event of a quench. Results of the quench analysis for several quench scenarios are presented.

Burkhardt, Earle↗

Electrostatic Relativistic Fluid Models of Electron Emission in a Warm Diode

A semi-analytic fluid model has been developed for characterizing relativistic electron emission across a warm diode gap. Here we demonstrate the use of this model in (i) verifying multi-fluid codes in modeling compressible relativistic electron flows (the EMPIRE-Fluid code is used as an example; see also Ref. 1), (ii) elucidating key physics mechanisms characterizing the influence of compressibility and relativistic injection speed of the electron flow, and (iii) characterizing the regimes over which a fluid model recovers physically reasonable solutions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

One-Step Transfer of Symmetric and Asymmetric Contacts for Large-Scale 2D Electronics and Optoelectronics

Two-dimensional (2D) semiconductors are highly promising candidates for thin-film transistor applications due to their scalability, transferability, atomic thickness, and relatively high carrier mobility. However, a substantial performance gap remains between individual devices based on single-crystalline 2D films and wafer-scale integrated circuits, primarily due to defects introduced during conventional fabrication processes. Here, we report a diamond-assisted electrode transfer technique for the van der Waals integration of wafer-scale prefabricated electrode arrays onto 2D materials, enabling scalable electronics and optoelectronics. Implemented on metal–organic chemical vapor deposition-grown monolayer molybdenum disulfide, this method forms ultraclean metal–semiconductor interfaces, yielding field-effect transistors with excellent ohmic contacts, a low contact resistance of 400 Ω·μm, and a Schottky barrier height of only 9 meV. Furthermore, we demonstrate a scalable transistor array on monolayer molybdenum disulfide with excellent device performance uniformity, achieving an average field-effect mobility of 30 cm 2 V –1 s –1 and an on/off current ratio exceeding 105. Additionally, high photocurrent and responsivity were demonstrated in the array devices, showing their potential for excellent image detection. We further demonstrate the versatility of this technique by fabricating a Schottky diode array through a single-step transfer of asymmetric electrodes─low work function aluminum and high work function gold─onto monolayer tungsten diselenide. This approach provides a clean, effective solution for contact engineering in 2D materials, offering a viable pathway toward wafer-scale, high-performance 2D electronics, optoelectronics, and integrated circuits.

2D electronics↗

W-band system-on-chip electron cyclotron emission imaging system on DIII-D

Monolithic, millimeter wave “system-on-chip” (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. Here, a prototype module operating in E-band (72-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor (ITER) relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California at Davis designed W-band (75 -110 GHz) receiver die that integrates a broadband low noise amplifier (LNA), a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength as well as downconvert the signal frequency. The upgraded W-band array exhibits > 30 dB additional gain and 20x improvement in noise temperature comparing with the previous Schottky diode radio frequency (RF) mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. The horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of 4H-SiC Low Gain Avalanche Detectors (LGADs)

Low gain avalanche detectors (LGADs) offer high temporal resolution for high energy particle detection, which is critical for next generation experiments in hadron colliders. While silicon LGADs (Si-LGADs) have rapidly matured in the last decade, research into silicon carbide (SiC) LGADs has only recently begun. By accounting for fundamental differences in material properties and fabrication processes, we present a prototype device design and process flow for 4H-SiC LGADs with etch-based isolation. Critical steps of the process flow and their results are discussed, including plasma etching, passivation, and the formation of low resistivity contacts. Electrical characterization (I-V, C-V) shows sufficient depletion of the device structure to demonstrate low-gain charge carrier multiplication.

High Energy Physics↗

Spectral sensor error analysis for measuring x-ray radiation drive using the DANTE diagnostic toward inertial confinement fusion experiments

DANTE is a diagnostic used to measure the x-radiation drive produced by heating a high-Z cavity (“hohlraum”) with high-powered laser beams. It records the spectrally and temporally resolved radiation flux at x-ray energies between 50 eV and 20 keV. Each sensor configuration on DANTE is composed of filters, mirrors, and x-ray diodes to define 18 different x-ray channels whose output is voltage as a function of time. The absolute flux is then determined from the photometric calibration of the sensor configuration and a spectral reconstructing algorithm. The reconstruction of the spectra vs time from the measured voltages and known response of each channel has presented challenges. Here we demonstrate a novel approach here for quantifying the error on the determined flux based on the channel sensor configuration and most commonly used reconstruction algorithm. In general, we find that the integrated spectral flux from a hohlraum can robustly be reconstructed (within ~14%) using a traditional unfold approach with as few as ten channels due to the underlying assumption of a largely Planckian spectral intensity distribution.

47 OTHER INSTRUMENTATION↗

Epitaxial Regrowth and Hole Shape Engineering for Photonic Crystal Surface Emitting Lasers (PCSELs)

In the present research, epitaxial regrowth by molecular beam epitaxy (MBE) is investigated as a fabrication process for void-semiconductor photonic crystal (PhC) surface emitting lasers (PCSELs). The PhC is patterned by electron beam lithography (EBL) and inductively coupled plasma (ICP) etch and is subsequently regrown by molecular beam epitaxy to embed a series of voids in bulk semiconductor. Experiments are conducted to investigate the effects of regrowth on air-hole morphology. The resulting voids have a distinct teardrop shape with the radius and depth of the etched hole playing a very critical role in the final regrown void’s dimensions. We demonstrate that specific hole diameters can encourage deposition to the bottom of the voids or to their sidewalls, allowing us to engineer the shape of the void more precisely as is required by the PCSEL design. A 980 nm InGaAs quantum well laser structure is optimized for low threshold lasing at the design wavelength and full device structures are patterned and regrown. An optically pumped PCSEL is demonstrated from this process.

36 MATERIALS SCIENCE↗

STARFIRE – Science and Technology Accelerated Research for Fusion Innovation and Reactor Engineering progress report

The STARFIRE hub leverages foundational science and technology (S&T) research and integrated plant modeling tools to advance Inertial Fusion Energy (IFE). S&T breakthroughs achieved in each thrust are incorporated into an integrated modeling tool to assess and prioritize remaining gaps to bridge for IFE to become viable. Scientific highlights span high-gain target design, diode-pumped solid-state lasers, and innovative target manufacturing. Key highlights include the investigation of shock propagation through various foam structures among other limiting factors of compression of IFE target, exploration of novel 3D printing techniques such as light-sheet additive manufacturing for 2-photon polymerization foams, and diode-pumped solid-state laser architectures required for several IFE approaches. In addition, the STARFIRE team has established two public-private working groups to address laser diode supply chain issues and test advanced laser diode configurations. Finally, a lite version of the integrated modeling tool has been developed to facilitate outreach and engage with private companies. STARFIRE’s management structure has been designed to ensure agile resource allocation, robust performance assessment, and alignment with the broader fusion energy mission. STARFIRE’s breakthroughs are disseminated to the community via reports, presentations, and publications, while agreements with private companies are set in place to protect proprietary information.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A genetic algorithm approach for reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. Here, we present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources—where the exact details of spectral content were not thought to be crucial—we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

47 OTHER INSTRUMENTATION↗