Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pileup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

83 records · Page 5

Measurement of the muon anomalous precession frequency $\omega_a$ in the Fermilab $g-2$ experiment

The Fermilab Muon $g-2$ Experiment was designed to measure the muon's anomalous magnetic moment $a_{\mu} = (g-2)/2$ to 140 parts per billion. The value of $a_{\mu}$ is proportional to the difference frequency $\omega_a=\omega_s-\omega_c$ between the muon's cyclotron frequency and spin precession frequency in the uniform magnetic field of the $g-2$ storage ring. The frequency $\omega_a$ is extracted from the time distribution of the mu-decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. We will discuss the various approaches to the frequency determination including the reconstruction, fitting of time distributions, and procedures for handling the effects of gain changes, positron pileup and beam dynamics. We also discuss the data consistency checks and the strategy for the averaging of $\omega_a$ across the different analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heterogeneous Reconstruction of Tracks and Primary Vertices With the CMS Pixel Tracker

The High-Luminosity upgrade of the Large Hadron Collider (LHC) will see the accelerator reach an instantaneous luminosity of 7 × 10 34 cm −2 s −1 with an average pileup of 200 proton-proton collisions. These conditions will pose an unprecedented challenge to the online and offline reconstruction software developed by the experiments. The computational complexity will exceed by far the expected increase in processing power for conventional CPUs, demanding an alternative approach. Industry and High-Performance Computing (HPC) centers are successfully using heterogeneous computing platforms to achieve higher throughput and better energy efficiency by matching each job to the most appropriate architecture. In this paper we will describe the results of a heterogeneous implementation of pixel tracks and vertices reconstruction chain on Graphics Processing Units (GPUs). The framework has been designed and developed to be integrated in the CMS reconstruction software, CMSSW. The speed up achieved by leveraging GPUs allows for more complex algorithms to be executed, obtaining better physics output and a higher throughput.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an MCP-Based Timing Layer for the LHCb ECAL Upgrade-2

The increase in instantaneous luminosity during the high-luminosity phase of the LHC represents a significant challenge for future detectors. A strategy to cope with high-pileup conditions is to add a fourth dimension to the measurements of the hits, by exploiting the time separation of the various proton–proton primary collisions. According to LHCb simulation studies, resolutions of about 10–20 picoseconds, at least an order of magnitude shorter than the average time span between primary interactions, would be greatly beneficial for the physics reach of the experiment. Microchannel plate (MCP) photomultipliers are compact devices capable of measuring the arrival time of charged particles with the required resolution. The technology of large-area picosecond photodetectors (LAPPDs) is under investigation to implement a timing layer that can be placed within a sampling calorimeter module with the purpose of measuring the arrival time of electromagnetic showers. LAPPD performances, using a Gen-I tile with a delay-line anode and a Gen-II with a capacitively coupled anode, have been measured thoroughly both with laser (wavelength of 405 nm and pulse width of 27.5 ps FWHM) and high-energy electron (1–5.8 GeV) beams. Time resolutions of the order of 30 ps for single photoelectrons and 15 ps for electromagnetic showers initiated by 5-GeV electrons, as measured at the shower maximum, are obtained.

47 OTHER INSTRUMENTATION↗

Hard X-Ray Excess from the Magnificent Seven Neutron Stars

We report significant hard X-ray excesses in the energy range 2–8 keV for two nearby isolated neutron stars: RX J1856.6-3754 and RX J0420.0-5022. These neutron stars have previously been observed in soft X-rays to have nearly thermal spectra at temperatures ~100 eV, which are thought to arise from the warm neutron star surfaces. We find nontrivial hard X-ray spectra well above the thermal surface predictions with archival data from the XMM-Newton and Chandra X-ray telescopes. We analyze possible systematic effects that could generate such spurious signals, such as nearby X-ray point sources and pileup of soft X-rays, but we find that the hard X-ray excesses are robust to these systematics to the extent that is possible to test. We also investigate possible sources of hard X-ray emission from the neutron stars and find no satisfactory explanation with known mechanisms, suggesting that a novel source of X-ray emission is at play. Here, we do not find high-significance hard X-ray excesses from the other five Magnificent Seven isolated neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Intermittent Electron-only Reconnection at Lunar Mini-magnetospheres

Abstract Lunar crustal magnetic anomalies (LCMA) are sub-ion-gyroradius structures that have been shown to stand off the solar wind (SW) plasma from the Moon’s surface, forming shock-like discontinuities and reflecting incident SW protons. In this Letter, the results of high-resolution, 2D fully kinetic simulations show a bursty electron-only magnetic reconnection in the SW-LCMA interaction region, characterized by the quasiperiodic formation and ejection of magnetic islands and strong parallel electron flows along the X-point separator lines. The islands are observed to modify the magnetic pressure pileup and Hall electric field above the LCMA, leading to sharp increases in reflected protons that drive electromagnetic fluctuations downstream and short distances upstream in the SW.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic Uncertainties in the NOvA \nu_\mu-Disappearance Analysis

As the NOvA long-baseline neutrino oscillation experiment takes more data, systematic uncertainty begins to more heavily impact the oscillation analyses. The largest effects are calibration on calorimetric energy, detector modeling on muon energy scale, and near-detector pileup on normalization of the far-detector expectation. Cross-section systematics will be discussed in another poster. Detailed studies have justified previous systematics as too conservative and suggested smaller values. Focused study of detector modeling using dE/dx and external measurements constrain the calibration and energy scale uncertainties. A novel technique is used to assess the impact of activity from neutrino activity piling up over signal, where a simulated neutrino is overlaid into both data and simulation. The difference in efficiency of selecting that single neutrino among data and simulated spills then dominates the normalization systematic.

Alion, Tyler [Sussex U.]↗

In-Pixel Readout IC with compact in-pixel ADC for Pixel detectors at HL LHC

The prototype Smart Pixel concept test chip (SP28), designed in a CMOS 28 nm bulk process, is a proof of concept readout integrated circuit (ROIC) designed for a future Phase III High Luminosity upgrade of the Large Hadron Collider. It employs a synchronous analog to digital converter (ADC) for the front-end design, with signal processing and data conversion within a single bunch crossing of 25 ns. It is therefore capable of accurately detecting hits occurring in consecutive bunch crossings, without off-time registration of events and pileup insensitivity, making it particularly suitable for the inner most layers of the vertex detector. The ROIC consists of a matrix of 32 × 16 pixels, each 25 × 25 µm 2 in size. Each pixel contains a charge sensitive preamplifer with leakage current compensation, three auto-zero comparators for a 2-bit fash-type ADC. The total power consumption is approximately 5 µW per pixel. The measured noise at the output of all the hit comparators across the ROIC is < 90 e- with threshold dispersion < 45 e-RMS, which allows an in-time threshold setting of ≈ 475 e-.

Parpillon, Benjamin↗

Measurement of the muon anomalous precession frequency in runs 2 \& 3 of the Muon $g-2$ Experiment at Fermilab

This dissertation presents a measurement of the muon anomalous precession frequency for the Runs 2 \& 3 data of the E989 Muon $g-2$ Experiment at Fermilab. The muon anomalous precession frequency is one of two key inputs, the other being the magnetic field, used to precisely determine the muon magnetic anomaly, $a_{\mu}$. In April 2021, the E989 collaboration reported its first measurement of $a_{\mu}$ to an unprecedented precision of 460 parts-per-billion (ppb). This result is in agreement with the previous measurement performed by the E821 collaboration at Brookhaven National Laboratory, and the combined experimental value is in tension with the Standard Model prediction at 4.2$\sigma$, a possible hint of new physics. The first result from E989 was based on the Run-1 data, which was collected in 2018 and comprises 6\% of the experiment’s target statistics; the Run-1 result was statistics-limited. The Runs 2 \& 3 data were collected in 2019-2020 and constitute a four-fold increase i n statistics compared to Run-1 and consequently, a factor of two reduction in the measurement’s statistical uncertainty. This reduced statistical uncertainty, as well as continued understanding of systematic effects, will result in an even more precise measurement of $a_{\mu}$ and will help clarify the observed tension between theory and experiment. The precession frequency analysis presented in this dissertation includes a number of improvements compared to Boston University's Run-1 analysis: the implementation of a more robust pileup-subtraction procedure, the implementation of a kernel ratio method, the adoption of the statistically optimal asymmetry-weighted method, and investigations that led to an improved understanding of an outstanding residual slow effect. This dissertation motivates a measurement of the muon magnetic anomaly, describes the experimental principle, gives an overview of the E989 experiment, and presents a precession frequency analysis with full systematic unc ertainty evaluation for the Runs 2 \& 3 data. The combined precession frequency measurement, using the ratio asymmetry-weighted method, has a statistical uncertainty of 201 ppb and a systematic uncertainty of 25 ppb, constituting the most precise determination of the muon anomalous precision frequency to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated integration gate selection for Gaussian mixture model pulse shape discrimination

Pulse shapes differ between neutron and gamma particles when measured with detector devices employing pulse shape discriminating (PSD) scintillators. Digitized waveforms can be used in detection systems to perform pulse shape discrimination for this application. Prior Gaussian Mixture Model (GMM) methods require access to the pulse full-waveform. Reducing the waveform to a smaller set of combined samples reduces computational cost while affecting PSD performance. In this work, we develop a method for selecting the best performing combination of integration gates, or contiguous summed segments of the digitized pulse for PSD. The method uses a discrimination score based on the GMM PSD approach. Furthermore, the final selection is performed using Bayesian Optimization. PSD detection results are compared with varying numbers of selected gates on time-of-flight (TOF) data. This method can be used to fully automate the selection of gates in an unsupervised (without ground truth labels) setting.

42 ENGINEERING↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗