Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Photon detectors for UV, visible and IR photons (vacuum) (photomultipliers, HPDs, others)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,748 records · Page 5

The Impact of Bias Row Noise to Photometric Accuracy: Case Study Based on a Scientific CMOS Detector

Abstract We tested a new model of CMOS detector manufactured by the Gpixel Inc, for potential space astronomical application. In laboratory, we obtain some bias images under the typical application environment. In these bias images, clear random row noise pattern is observed. The row noise also contains some characteristic spatial frequencies. We quantitatively estimated the impact of this feature to photometric measurements, by making simulated images. We compared different bias noise types under strict parameter control. The result shows the row noise will significantly deteriorate the photometric accuracy. It effectively increases the readout noise by a factor of 2–10. However, if it is properly removed, the image quality and photometric accuracy will be significantly improved.

Astronomy & Astrophysics

Research and Development Related to the Commercialization of Perovskite Radiation Detectors (CRADA Final Report)

This work will focus on the development of perovskite radiation detectors fabricated with nanocrystal, thick polycrystalline films, or single crystal materials. This will harness NREL’s instrumentation and expertise in a variety of research areas including but not limited to metal halide perovskites, device characterization, device packaging, accelerated lifetime testing, and ink chemistry development.

14 SOLAR ENERGY

Mitigating electrochemical degradation in CsPbBr{sub 3} gamma detectors by organic and inorganic encapsulation.

CsPbBr3 perovskite semiconductors have emerged as a leading candidate for nextgeneration radiation detectors because of their exceptional charge transport properties, defect tolerance, and record-breaking sensitivity and energy resolution. Their long-term stability, however, is hindered by electrode-driven electrochemical decomposition, which is accelerated by moisture- and oxygen-assisted ion migration during operation. Here, we investigated organic and inorganic encapsulation strategies as both environmental barriers and means to suppress interfacial degradation pathways. Atomic layer deposition (ALD) of Al2O3 provided a conformal passivation layer that blocked environmental ingress, suppressed ionic diffusion, reduced leakage current, enhanced energy resolution and expanded the operational electric-field window beyond 5 kV∙cm1 . By contrast, organic encapsulants such as paraffin wax and polystyrene slowed moisture diffusion but did not suppress interfacial reactions, with wax extending stability to over 90 days. These results show that ALD-Al2O3 suppresses dominant interfacial degradation pathways, enabling stable, high-field operation and advancing the practical deployment of CsPbBr3 γ-ray detectors.

Unal, Mustafa

Isotropic negative thermal expansion in ZrW 2 O 8 and HfW 2 O 8 from 1100 to 1275°C

Abstract ZrW 2 O 8 (ZrO 2 •2WO 3 ) and HfW 2 O 8 (HfO 2 •2WO 3 ) have been the focus of thermal expansion studies due to their isotropic negative thermal expansion (NTE) measured previously at temperatures below 775°C. This work presents measurements of these materials at their thermodynamically stable temperature ranges of 1105 and 1257°C for ZrW 2 O 8 and 1105–1276°C for HfW 2 O 8 , where they were characterized with in situ, powder X‐ray diffraction. The linear coefficients of thermal expansion were measured to be −5.52 × 10 −6 and −4.87 × 10 −6 °C −1 for ZrW 2 O 8 and HfW 2 O 8 , respectively. The mechanism leading to this NTE is discussed. Powder samples were synthesized by a solution‐based process called the organic–inorganic steric entrapment method. In situ characterization in air was carried out at the National Synchrotron Light Source II using a hexapole lamp, optical furnace and the Advanced Photon Source using a quadrupole lamp, optical furnace to achieve elevated temperatures.

Materials Science

Mitigating Hydrogen-Induced Degradation of Iridium Anodes in Proton Exchange Membrane Water Electrolyzers

One promising method for reducing precious metal usage in proton exchange membrane water electrolysis is lowering iridium (Ir) loading at the anode. However, low-loading Ir catalysts often suffer from poor stability under high current densities. In this study, hydrogen (H2) crossover from the cathode to the anode is identified as a key degradation pathway. Temperature-programmed reduction confirms the reduction of IrO2 at 80 °C in a hydrogen environment, highlighting the vulnerability of IrO2-based catalysts to H2 exposure. To mitigate this effect, palladium (Pd) is introduced as an anode additive, acting as an H2 oxidation catalyst and mitigating IrO2 reduction. This protective role is verified by inductively coupled plasma optical emission spectroscopy and in situ X-ray absorption spectroscopy, showing significantly suppressed Ir dissolution at 80 °C under H2 flow when an O-covered Pd surface is present at oxygen evolution reaction potentials. Results from the current study identify a new strategy in improving activity and durability of catalysts in electrolyzers.

58 GEOSCIENCES

The brighter-fatter effect in the JWST MIRI Si:As IBC detectors: I. Observations, impact on science, and modeling

Context.The Mid-Infrared Instrument (MIRI) on board theJames WebbSpace Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims.We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods.We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the publicPoisson_CCDcode. Results.We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of charge-coupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10–25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.

Astronomy & Astrophysics

Radiation-induced alteration of apatite on the surface of Mars: first in situ observations with SuperCam Raman onboard Perseverance

Abstract Planetary exploration relies considerably on mineral characterization to advance our understanding of the solar system, the planets and their evolution. Thus, we must understand past and present processes that can alter materials exposed on the surface, affecting space mission data. Here, we analyze the first dataset monitoring the evolution of a known mineral target in situ on the Martian surface, brought there as a SuperCam calibration target onboard the Perseverance rover. We used Raman spectroscopy to monitor the crystalline state of a synthetic apatite sample over the first 950 Martian days (sols) of the Mars2020 mission. We note significant variations in the Raman spectra acquired on this target, specifically a decrease in the relative contribution of the Raman signal to the total signal. These observations are consistent with the results of a UV-irradiation test performed in the laboratory under conditions mimicking ambient Martian conditions. We conclude that the observed evolution reflects an alteration of the material, specifically the creation of electronic defects, due to its exposure to the Martian environment and, in particular, UV irradiation. This ongoing process of alteration of the Martian surface needs to be taken into account for mineralogical space mission data analysis.

Science & Technology - Other Topics

Evidence of Free-Bound Transitions in Warm Dense Matter and Their Impact on Equation-of-State Measurements

Warm dense matter (WDM) is now routinely created and probed in laboratories around the world, providing unprecedented insights into conditions achieved in stellar atmospheres, planetary interiors, and inertial confinement fusion experiments. However, the interpretation of these experiments is often filtered through models with systematic errors that are difficult to quantify. Due to the simultaneous presence of quantum degeneracy and thermal excitation, transitions in which free electrons are de-excited into thermally unoccupied bound states transferring momentum and energy to a scattered x-ray photon become viable. Here we show that such free-bound transitions are a particular feature of WDM and vanish in the limits of cold and hot temperatures. The inclusion of these transitions into the analysis of recent X-ray Thomson Scattering experiments on WDM at the National Ignition Facility and the Linac Coherent Light Source is required to obtain a physically consistent temperature from the Chihara decomposition. This interpretation is corroborated by agreement with a recently developed model-free thermometry technique and presents an important step for precisely characterizing and understanding the complex WDM state of matter.

Boehme, M [HZDR Dresden]

Qualifying LaBr3:Ce+Sr detector performance for the Mu2e experiment at Fermilab Using the ELBE Accelerator

A LaBr3:Ce+Sr detector will be used to measure the stopped muon captures at the Mu2e experiment at Fermilab. It has been benchmarked in a test beam experiment performed at the ELBE electron accelerator located at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. ELBE’s pulsed bremsstrahlung beam line was set to deliver an average γ -ray energy of between 4–5 MeV. The detector response was mapped to match Mu2e beam conditions, including rates up to 1 Mcps, energy flux, and time structure. A radioactive calibration source was used to mimic the characteristic 1808.7 keV γ -ray, emitted during the atomic muon nuclear capture in the Mu2e aluminum stopping target. The detector energy resolution was measured as a function of the average energy flux: up to 1 TeV/s for 0.34 s, the steady-operation beam-on time and up to 4 TeV/s for 5 ms to get a conservative estimate of the effect of high intensity Mu2e beam fluctuations. The PMT gain variation as a function of the beam spill length and average intensity has been parametrized and corrected for. When a PMT gain correction corresponding to the average beam-spill intensity is applied, the residual effect of beam intensity fluctuations around the average degrades the energy resolution, σ E γ /E γ , at 1808.7 keV from 0.66% to 0.83%.

Huang, Shihua [Purdue U., West Lafayette]

Numerical Investigation of Fluid Flow and Space Charge in Liquid Argon Time Projection Chamber (LArTPC) Detectors

Overview This project focused on developing a high-fidelity numerical framework to simulate the multiphysics environment within Liquid Argon Time Projection Chamber (LArTPC) detectors. The primary objective was to characterize the complex interplay between ion transport, background fluid dynamics, and electric field distortions—a critical factor for the calibration and sensitivity of next-generation High Energy Physics experiments, such as DUNE. Technical Achievements The research successfully yielded a hybrid numerical space-charge solver utilizing a Cell-Centered Finite Volume Method (FVM) for ion transport coupled with a Finite Element Method (FEM) for electric potential. Key accomplishments include: • Verification & Validation: The 3-D solver was rigorously verified against 1-D analytical solutions, demonstrating high numerical accuracy in predicting space-charge-induced field deviations. • Field Distortion Analysis: 3D simulations revealed that space charge effects introduce significant non-uniformities in the electric field. Critically, the research identified that background LAr flow velocities, when comparable to ion drift velocities, markedly exacerbate these distortions. • Technology Transfer: The resulting source code and comprehensive user manuals were successfully transferred to collaborators at Fermilab, providing a portable computational tool for the broader scientific community. Challenges and Future Directions While the space-charge solver achieved all performance metrics, the integrated fluid dynamics modeling encountered convergence challenges stemming from the extreme 200-fold disparity in length scales between the detector's 37 mm inlet pipes and the 8-meter global domain. To address this, the project has identified a clear technical pivot toward Hierarchical Geometric Adaptive Mesh Refinement (HG-AMR). By implementing an h-type refinement strategy with hanging nodes, future iterations of this solver will be capable of resolving localized high-gradient inlet flows without the prohibitive computational costs of regular grids. This advancement, combined with data-driven uncertainty quantification based on MicroBooNE-style calibration, will enable the precise modeling of detector responses in large-scale cryogenic environments where direct measurement remains difficult. Impact The computational tools developed under this award provide a foundation for enhancing the energy resolution and spatial reconstruction of noble liquid detectors. By bridging the gap between theoretical fluid dynamics and experimental field calibration, this work supports the DOE’s mission to advance the frontiers of neutrino physics and dark matter detection.

42 ENGINEERING

Mode Multiplexing for Scalable Cavity-Enhanced Operations in Neutral-Atom Arrays

Neutral-atom arrays provide a versatile platform for quantum information processing. However, in large-scale arrays, efficient photon collection remains a bottleneck for key tasks such as fast, nondestructive qubit readout and remote entanglement distribution. We propose a cavity-based approach that enables fast, parallel operations over many atoms using multiple modes of a single optical cavity. By selectively shifting the relevant atomic transitions, each atom can be coupled to a distinct cavity mode, allowing independent simultaneous processing. We present practical system designs that support cavity-mode multiplexing with up to 50 modes, enabling rapid mid-circuit syndrome extraction and significantly enhancing entanglement distribution rates between remote atom arrays. This approach offers a scalable solution to core challenges in neutral-atom arrays, advancing the development of practical quantum technologies.

Aqua, Ziv [Massachusetts Institute of Technology (

Phonon-mediated ultrafast dynamics in self-assembled monolayers of 4-mercaptobenzoic acid on gold

Non-equilibrium interactions between plasmonic metals and adsorbed molecules lie at the heart of emerging applications such as plasmonic photocatalysis and sensing, though the ultrafast charge and energy transfer mechanisms arising from these interactions are not well understood. Herein, we investigate the ultrafast dynamics of Au nano-islands tethered with a self-assembled monolayer (SAM) of electron-withdrawing 4-mercaptobenzoic acid (4MBA) molecules. Ultrafast UV-visible transient absorption spectroscopy following excitation of the interband transition in Au reveals three well-known, characteristic time constants that quantify electron–electron (el–el), electron–phonon (el–ph) and phonon–phonon (ph–ph) scattering lifetimes. When comparing the dynamics of bare Au and 4MBA-Au, we find that the el–ph and ph–ph scattering lifetimes are notably longer in 4MBA-Au. Density functional perturbation theory calculations ascribe the elongation in el–ph lifetimes in 4MBA-Au to the significant coupling of acoustic phonon modes of Au with certain molecular vibrations of 4MBA, leading to decreased spatial overlap between carrier electronic states and the acoustic modes. We speculate that the elongation of ph–ph scattering lifetimes in 4MBA-Au arises due to poor thermal conductivity of the SAM which disrupts efficient energy dissipation from Au to the environment, thus slowing down the thermalization of phonons. This work provides a glimpse into how molecular adsorbates modify the charge carrier and phonon dynamics of Au and sets the stage for further systematic exploration of plasmonic metal–molecule interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Machine learning the electric field response of condensed phase systems using perturbed neural network potentials

Abstract The interaction of condensed phase systems with external electric fields is of major importance in a myriad of processes in nature and technology, ranging from the field-directed motion of cells (galvanotaxis), to geochemistry and the formation of ice phases on planets, to field-directed chemical catalysis and energy storage and conversion systems including supercapacitors, batteries and solar cells. Molecular simulation in the presence of electric fields would give important atomistic insight into these processes but applications of the most accurate methods such as ab-initio molecular dynamics (AIMD) are limited in scope by their computational expense. Here we introduce Perturbed Neural Network Potential Molecular Dynamics (PNNP MD) to push back the accessible time and length scales of such simulations. We demonstrate that important dielectric properties of liquid water including the field-induced relaxation dynamics, the dielectric constant and the field-dependent IR spectrum can be machine learned up to surprisingly high field strengths of about 0.2 V Å −1 without loss in accuracy when compared to ab-initio molecular dynamics. This is remarkable because, in contrast to most previous approaches, the two neural networks on which PNNP MD is based are exclusively trained on molecular configurations sampled from zero-field MD simulations, demonstrating that the networks not only interpolate but also reliably extrapolate the field response. PNNP MD is based on rigorous theory yet it is simple, general, modular, and systematically improvable allowing us to obtain atomistic insight into the interaction of a wide range of condensed phase systems with external electric fields.

Science & Technology - Other Topics

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)

A fully light-driven approach to separate carbon dioxide from emission streams

Carbon capture from industrial point sources is an essential component of the global effort to mitigate climate risks. However, traditional approaches require significant energy input—often provided, counterproductively, by fossil fuel combustion. Using sunlight directly as the energy source would significantly improve the energy efficiency of carbon capture processes. Herein, we report the first fully visible-light-driven CO 2 separation system, in which carbon capture is achieved via the photoenolization/addition reaction of inexpensive 2-methylbenzophenone with CO 2 , and CO 2 release is realized through an intramolecular photodecarboxylation reaction. Finally, this system operates isothermally, works with natural sunlight, and facilitates CO 2 removal from natural gas flue emissions, providing a blueprint for other non-thermal chemical separations.

Ahmad, Bayu I. Z. [Cornell Univ., Ithaca, NY (Unit

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences

Bipolar Blobs as Evidence of Hidden AGN Activities in the Low-mass Galaxies

Abstract We report evidence of a hidden black hole (BH) in a low-mass galaxy, MaNGA 9885-9102, and provide a new method to identify active BHs in low-mass galaxies. This galaxy is originally selected from the MaNGA survey with distinctive bipolar Hαblobs at the minor axis. The bipolar feature can be associated with active galactic nuclei (AGN) activity, while the two blobs are classified as the Hiiregions on the BPT diagram, making the origins confusing. The Swift UV continuum shows that the two blobs do not have UV counterparts, suggesting that the source of ionization is out of the blobs. Consistent with this, the detailed photoionization models prefer AGN rather than the star-forming origin with a significance of 5.8σ. The estimated BH mass isM BH ∼ 7.2 × 10 5 M ⊙ from theM BH –σ * relationship. This work introduces a novel method for detecting the light echo of BHs, potentially extending to intermediate mass, in low-metallicity environments where the traditional BPT diagram fails.

Astronomy & Astrophysics