Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Spatially Resolved Performance Analysis for Perovskite Solar Cells

This review explores the current state of the art in spatially resolved characterization of mixed-halide perovskite solar cells. As the size of perovskite cells and modules continues to grow, quantification of the spatial distribution of key cell parameters will become increasingly valuable in predicting ultimate cell-level performance and tracking process homogeneity. Here, both high resolution microscopic approaches using scanning techniques and camera-based methods for full-area cell and/or module analysis are discussed. The value of this local data in predicting performance losses at the cell level is particularly emphasized. Measurable physical parameters sensitive to losses of voltage, current, fill factor, and efficiency are discussed together with selected experimental results. It is demonstrated that a combination of spatially resolved cell parameter mapping/imaging can be used to quantitatively discriminate various loss contributions at high resolution. The impact and control of inhomogeneities become particularly important when upscaling from small devices to large formats compatible with industrial mass production.

14 SOLAR ENERGY↗

UMAMI: A Recipe for Generating Meaningful Metrics through Holistic I/O Performance Analysis

I/O efficiency is essential to productivity in scientific computing, especially as many scientific domains become more data-intensive. Many characterization tools have been used to elucidate specific aspects of parallel I/O performance, but analyzing components of complex I/O subsystems in isolation fails to provide insight into critical questions: how do the I/O components interact, what are reasonable expectations for application performance, and what are the underlying causes of I/O performance problems? To address these questions while capitalizing on existing component-level characterization tools, we propose an approach that combines on-demand, modular synthesis of I/O characterization data into a unified monitoring and metrics interface (UMAMI) to provide a normalized, holistic view of I/O behavior. We evaluate the feasibility of this approach by applying it to a month-long benchmarking study on two distinct largescale computing platforms. We present three case studies that highlight the importance of analyzing application I/O performance in context with both contemporaneous and historical component metrics, and we provide new insights into the factors affecting I/O performance. By demonstrating the generality of our approach, we lay the groundwork for a production-grade framework for holistic I/O analysis.

97 MATHEMATICS AND COMPUTING↗

Comparative performance analysis of relative humidity sensor based on intermodal interference using tapered square no-core optical fiber and tapered cylindrical optical fiber

This work presents the computational evaluation of a new model for relative humidity sensor based on the principle of intermodal interference using a square-section no-core tapered optical fiber compared to a classical cylindrical tapered optical fiber sensor. Attempting at a new application of this type of sensor, simulations were carried out in the range of up to 60% of relative humidity, the main interest range of the pharmaceutical industry. Several materials were used in its modeling and an analysis was developed in its constructive dimensions, in order to verify the influence of each of them on the sensor performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance Analysis of Scientific Computing Workloads on Trusted Execution Environments

Scientific computing sometimes involves computation on sensitive data. Depending on the data and the execution environment, the HPC (high-performance computing) user or data provider may require confidentiality and/or integrity guarantees. To study the applicability of hardware-based trusted execution environments (TEEs) to enable secure scientific computing, we deeply analyze the performance impact of AMD SEV and Intel SGX for diverse HPC benchmarks including traditional scientific computing, machine learning, graph analytics, and emerging scientific computing workloads. We observe three main findings: 1) SEV requires careful memory placement on large scale NUMA machines (1x -3.4x slowdown without and 1x -1.15x slowdown with NUMA aware placement), 2) virtualization - a prerequisite for SEV - results in performance degradation for workloads with irregular memory accesses and large working sets (1x -4x slowdown compared to native execution for graph applications) and 3) SGX is inappropriate for HPC given its limited secure memory size and inflexible programming model (1.2x -126x slowdown over unsecure execution). Finally, we discuss forthcoming new TEE designs and their potential impact on scientific computing.

97 MATHEMATICS AND COMPUTING↗

Network performance analysis for HPC datacenters (net_perf) v1.0

The software has two main features: (1) identify data movement trends in HPC data centers that use network flow monitoring (2) analyze the performance of individual data flows under the existing data movement management strategy and identify performance bottlenecks that impede timely data availability for science workflows. Its main advantage is that it is tailored for HPC network traffic by considering HPC data movement management intricacies.

Giannakou, Anna↗

Performance Analysis of High-Temperature Heat Pumps with Two-Phase Ejectors

A two-phase ejector recovers the energy in the refrigerant cycles’ throttling process, improving the coefficient of performance (COP) of high-temperature heat pumps (HTHPs). This study investigated the effects of the mixing pressure on the performance of two-phase ejectors and ejector-assisted HTHPs. A 1D theoretical model of a two-phase ejector was built to predict the internal fluid dynamics and evaluate ejector performance. A thermodynamic model of an ejector-assisted HTHP was built to evaluate the COP of HTHPs and the volumetric heating capacity of low-global warming potential refrigerants. The results demonstrate that an optimum mixing pressure in a two-phase ejector provides the best performance of a two-phase ejector and ejector-assisted HTHP. The optimum mixing pressure was slightly lower than the evaporation pressure. At this pressure, the two-phase flow in the ejector was subsonic. For ejector-assisted HTHPs using low–global warming potential refrigerants at a sink temperature of 120°C, temperature lift of 40°C, and subcooling of 10°C, a two-phase ejector has an average ejector efficiency of 0.334, and the COP and volumetric heating capacity were improved by 7.2% and 7.3%, respectively.

Wang, Pengtao↗

The Tianlai Cylinder Pathfinder Array: System Functions and Basic Performance Analysis

The Tianlai Cylinder Pathfinder is a radio interferometer array designed to test techniques for 21 cm intensity mapping in the post-reionization Universe, with the ultimate aim of mapping the large scale structure of the Universe and measuring cosmological parameters such as the dark energy equation of state. Each of its three parallel cylinder reflectors are oriented in the north-south direction, and the array has a large field of view. As the Earth rotates, the northern sky is observed by drift scanning. The array is located in Hongliuxia, a radio quiet site in Xinjiang, and saw its first light in September 2016. In this first paper on the data analysis of the Tianlai cylinder array, we describe the system functions of the array, the commissioning observations during 2016- 2018, and present its basic performance characteristics. We show examples of the interferometric visibility data, then using the observational data, we derive the actual beam profile in the east-west direction, the bandpass response, and calibrate the complex gains for the array elements either with a strong astronomical point source, or with an artificial calibrator source. Based on the preliminary analysis of the data, we derive the system temperature and sensitivity of the array.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Performance Analysis on Approximately 320 Perovskite Single- and Two-Junction Solar Cells and Modules from >30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? We compile results from ca. 320 perovskite PV cells and modules, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, and show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. We discuss implications of these findings on performance testing protocols and propose possible options for fast and accurate testing of perovskite PV.

asymptotic↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Performance Analysis of Transposition Models Simulating Solar Radiation on Inclined Surfaces

Transposition models have been widely used in the solar energy industry to simulate solar radiation on inclined photovoltaic panels. Following numerous studies comparing the performance of transposition models, this work aims to understand the quantitative uncertainty in state-of-the-art transposition models and the sources leading to the uncertainty. Our results show significant differences between two highly used isotropic transposition models, with one substantially underestimating the diffuse plane-of-array irradiances when diffuse radiation is perfectly isotropic. In the empirical transposition models, the selection of the empirical coefficients and land surface albedo can both result in uncertainty in the output. This study can be used as a guide for the future development of physics-based transposition models and evaluations of system performance.

14 SOLAR ENERGY↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

Performance Analysis of Electrodynamic Screens Based on Residual Particle Size Distribution

Dust accumulation on the optical surfaces of solar collectors causes significant losses in their energy yield. Fine dust particles, compared with coarse ones, contribute significantly more in the performance loss, assuming identical surface mass concen- tration. This study examines the performance of different electro- dynamic screen (EDS) prototypes, operated under different con- ditions, in removing fine dust particles in the laboratory environ- ment. After going through several cycles of dust deposition and cleaning using EDS, the dust residue left on each EDS prototype is collected and analyzed using a Horiba particle size distribution (PSD) analyzer. The PSD analyses determine which EDS design has performed superior in removing a given size range and in which operational condition. Here, the results are advantageous in the optimization procedure of EDS to attain maximum dust removal efficiency and minimum optical interference.

14 SOLAR ENERGY↗

Field Demonstration of Ground-Source Integrated Heat Pump Part I. Technology and Field Demo System/Site Descriptions, and Preliminary Summer/Fall Performance Analysis for One Site

The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming from reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.

20 FOSSIL-FUELED POWER PLANTS↗

Performance analysis of single-phase immersion cooling system of data center using FC-40 dielectric fluid

Immersion cooling technologies have become an emerging cooling method for data center cooling. The studies available in open literature dealt with immersion cooling performance of data servers using mineral oil, EC-100, and Opticool 872552, but the studies focusing on the performance of FC-40 dielectric fluid is not available. Therefore, this study aimed to develop a single-phase liquid immersion cooling system using FC-40 dielectric fluid for a 1U (44.45 mm height) data server. The present study experimentally investigated the influence of different design and operating parameters, including the inlet/outlet port configuration (T and Z configurations), the bypass effect, the flowrate (1–3 LPM), the heating load (200–600 W), the inlet fluid temperature (15–35 °C), the presence of suction fan with various arrangements, and different heat sink bases (solid base, vapor chamber and heat pipe base). The results showed that the T-configuration could provide a 12.6% and 0.5–2.8 °C reduction in thermal resistance and case temperature compared to the Z-configuration, respectively. Additionally, the heat sink with heat pipe and vapor chamber base offered a minimum case temperature of 56.7 °C and 55.2 °C against the 60 °C experienced in the heat sink with flat plate base, respectively.

42 ENGINEERING↗

Composition-Nanoarchitecture-Performance Analysis of High Energy Density Electrodeposited Silicon for Lithium-Ion Battery Anodes

Electrodeposition of silicon (Si) was previously demonstrated as a promising method for fabricating 3D-structured lithium-ion battery anodes. However, the relationship between the electrochemical performance and chemical composition of the relatively impure electrodeposited silicon is not well understood. Here, we report the electrodeposition of a Si-dominant active material (EDEP-Si) onto 3D-structured nickel (Ni) scaffolds and systematically compare the electrochemical properties, elemental composition, atomistic Si coordination, and molecular structure of EDEP-Si with high-purity amorphous Si grown via static chemical vapor deposition. Despite the considerable amount of carbon (9–11 at %) and oxygen (42–44 at %) present in EDEP-Si, the cycling stability and high reversible specific capacity are remarkably similar to those of CVD-Si on a silicon basis (~2400 mA h/g-Si after 100 cycles). The primary difference is that EDEP-Si exhibits reduced cycling efficiency over the first 10–20 cycles. Reactions between carbon and, more importantly, oxygen in EDEP-Si with lithium are likely responsible for the reduced early cycle performance and lower capacity of the total deposit. Finally, our observations suggest ultrapure Si is not necessary for high electrochemical access to reversible charge storage, although limiting the presence of incorporated impurity species would improve energy density and first cycle efficiency.

25 ENERGY STORAGE↗

Human Performance Analysis Depending on Operator Expertise (Student vs. Operator) and Simulator Complexity (Rancor Microworld vs. Compact Nuclear Simulator)

Human reliability analysis (HRA) evaluates human errors and provides human error probabilities (HEPs) for application in probabilistic safety assessment (PSA), which is a comprehensive safety assessment method for nuclear power plants (NPPs). Generally, HRA methods estimate HEPs based on human reliability data collected from actual historical measurement, simulator experiments, or expert judgement. Most recent HRA data collection studies focus on collecting data via full-scope main control room (MCR) simulators with actual licensed reactor operators. Contrary to this, Idaho National Laboratory (INL) has adopted a different approach, which attempts to collect HRA data based on experiment using simplified simulators and student participants by following the Simplified Human Error Experimental Program (SHEEP). This approach has a couple of advantages compared to full-scope data collection. Representatively, it has relatively low entry point for collecting HRA data, and secures large sample sizes with reasonable cost and labor. In the previous studies, we developed the SHEEP framework, then verified whether the data collected through the framework could support a representative full-scope data collection study, i.e., the Human Reliability Data Extraction (HuREX) study. Also, we analyzed human performance measurements depending on participant type (i.e., student vs. operator). In this paper, we analyze human performance data collected from an experiment comparing operator expertise and simulator complexity when using the more simplified simulator developed by INL, i.e., Rancor Microworld and the less simplified simulator, i.e., Compact Nuclear Simulator (CNS) developed by Korea Atomic Energy Research Institute (KAERI). Analysis of variance (ANOVA) tests and correlation analysis are used for analyzing the experimental data.

99 GENERAL AND MISCELLANEOUS↗