Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. This paper proposes a holistic impulse-based MOV lifetime estimation framework. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

Comparative Study and Validation of Photovoltaic Model Formulations for the IBPSA Modelica Library based on Rooftop Measurement Data

Domain-overarching system models are crucial to investigate sector coupling concepts. Specifically, the coupling of building and electrical energy systems becomes crucial to integrate renewable energy sources such as photovoltaic power systems (PV). For such interdisciplinary simulation models, Modelica is a suitable language. However, most open-source Modelica libraries are either domain-specific or lack simple-to-parameterize PV models. We close this gap by developing a PV model for the IBPSA Modelica library. The model comprises two I-V-characteristic models and three mounting-dependent approaches to calculate the cell temperature. The I-V-characteristic models follow a single- and two-diodes approach. This study uses measurement data from a rooftop PV system in Berlin, Germany, for validation. The focus lies on comparing the implemented single- and two-diodes approach. Results prove that both models accurately calculate the modules’ DC power output and cell temperature. The two-diodes approach slightly outperforms the single-diode one at the expense of a higher parameterization effort.

Maier, Laura↗

Open data sets for assessing photovoltaic system reliability

Photovoltaic (PV) systems have become a cornerstone of renewable energy strategies, particularly due to the significant reduction in solar power costs over the past decade. However, the long-term reliability of PV installations presents a persistent challenge, requiring the development of advanced monitoring and predictive maintenance strategies. A wide range of data types is used to evaluate the health of PV systems, including environmental conditions, electrical performance, and inspection imagery. These data enable methodologies such as machine learning (ML) models for lifetime prediction and computer vision techniques for defect detection. However, the acquisition of high-quality and comprehensive data is difficult, particularly in terms of long-term consistency and data variety. Publicly available data sets serve as valuable resources for addressing these challenges, but they often suffer from fragmentation and are difficult to access. This paper presents a comprehensive review of existing open-source data sets related to PV degradation, analyzing their features, functionalities, and potential applications. We categorize these data sets based on the specific aspects of PV system information they cover, such as environmental conditions, operational monitoring, image inspection and module materials, and propose relevant tools and ML models for processing them. In addition, we propose practices for future data collection and usage, while also discussing potential directions in data-driven research. Our aim is to enhance data utilization and publication among researchers and industry professionals, promoting a deeper understanding of the role of data in enhancing the performance and durability of PV systems.

14 SOLAR ENERGY↗

Metal Oxide Varistor (MOV) Lifetime Estimation with Impulse-Based Testing in PV Inverter Systems: Preprint

Surges caused by lightning strikes could damage electrical components in photovoltaic (PV) systems. Metal oxide varistors (MOVs) are commonly used to protect PV systems from lightning strikes. In this paper, a holistic impulse-based MOV lifetime estimation framework is proposed. The impacts of peak current and fault duration induced by lightning events are considered in the MOV lifetime estimation framework. Moreover, the impact of different parameter combinations on MOV lifetime estimation is analyzed. The effectiveness of the proposed work is validated in a PV inverter test system developed in MATLAB/Simulink.

lifetime estimation↗

Use of Operating Agreements and Energy Storage to Reduce Photovoltaic Interconnection Costs: Technical and Economic Analysis

This report presents an analytical methodology to identify alternative options to manage interconnection costs and streamline interconnection timelines for distribution system-connected photovoltaic (PV) systems not co-located with load. Specifically, the report details the methodology and results of an analysis that: 1. Identifies potential grid violations that would be induced by a PV system requesting interconnection to a distribution circuit; 2. Identifies multiple technically viable options for mitigating the potential violations, including infrastructure upgrades, downsizing the PV system size, curtailment of PV, and addition of battery energy storage; 3. Defines the required technical operating parameters of the system in order to mitigate all potential violations (the "Operating Envelope"); 4. Compares the economics of each option, from the PV developer's perspective. The analysis supports the ongoing evolution of interconnection standards for combined PV and energy storage systems by providing a methodology to define allowable maximum export limits during each hour. The methodology presented could be used by utilities as part of the interconnection study process, to inform negotiations with DER developers and the drafting of mutually acceptable interconnection agreements. The resulting technical operating parameters could be included as part of the interconnection service agreement (ISA) between the system owner and the utility company. The companion report to this analysis, Gill et al. (2022), details the envisioned framework for the implementation of the technical operating parameters.

14 SOLAR ENERGY↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1k VA experimental setup that interfaces a PV module to the grid.

generalized PV controller↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems: Preprint

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.

dc-dc control↗

Multi-Agent Deep Reinforcement Learning for Realistic Distribution System Voltage Control Using PV Inverters

Over the last few decades, the deployment of distributed solar photovoltaic (PV) systems has increased consistently. High PV penetration could cause adverse effects on the grid, such as voltage violations. This paper proposes a new distributed soft actor-critic based multi-agent deep reinforcement learning (SAC-MADRL) control solution to minimize the PV real power curtailment while keeping the grid voltage in an acceptable range. New reward functions have been designed to coordinate different agents during the learning process, yielding improved convergence. Comparison results with other control methods on a real feeder in western Colorado U.S. with 80% penetration of PVs demonstrate that the proposed method has better capability of effectively regulating voltage while minimizing the PV real power curtailment.

distribution system↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks: Q1 2021

Based on our bottom-up modeling, the Q1 2021 PV and energy storage cost benchmarks are: $\$2.65$ per watt DC (WDC) (or $\$3.05$/WAC) for residential PV systems, 1.56/WDC (or $\$1.79$/WAC) for commercial rooftop PV systems, $\$1.64$/WDC (or $\$1.88$/WAC) for commercial ground-mount PV systems, $\$0.83$/WDC (or $\$1.13$/WAC) for fixed-tilt utility-scale PV systems, $\$0.89$/WDC (or $\$1.20$/WAC) for one-axis-tracking utility-scale PV systems, $\$30,326$-$\$33,618$ for a 7.15-kWDC residential PV system with 5 kW/12.5 kWh nameplate of storage, $\$2.04$ - $\$2.10$ million for a 1-MWDC commercial ground-mount PV system colocated with 600 kW/2.4 MWhusable of storage, $\$166$ - $\$167$ million for a 100-MWDC one-axis tracker PV system colocated with 60 MW/240 MWhusable of storage. Between 2020 and 2021, there were 3.3% ($\$0.0$9/W), 10.7% ($\$0.19$/W), and 12.3% ($\$0.13$/W) reductions (in 2020 USD) in the residential, commercial rooftop, and utility-scale (one-axis) PV system cost benchmarks respectively. Balance of system (BOS) costs have either increased or remained flat across sectors, year-on-year, unlike in previous benchmark reports, which generally have reported declining BOS costs. The increase in BOS cost has been offset by a 17% reduction in module cost. Overall, modeled PV installed costs across the three sectors have declined compared to our Q1 2020 system costs.

14 SOLAR ENERGY↗

Energy and Carbon Payback Times for Modern U.S. Utility Photovoltaic Systems

Manufacturing and operating a PV system consumes non-renewable energy and produces carbon emissions, as does end-of-life handling when PV systems are eventually decommissioned. To fully account for PV's contribution toward decarbonization, these life cycle impacts must be quantified. A 2023 NREL LCA of utility PV systems in the United States Study show energy payback times between 0.5 and 1.2 years and carbon payback times between 0.8 to 20 years, depending on the system install location. Payback times are affected by the amount of local solar radiation, and carbon payback time is significantly affected by the carbon-intensity of the local grid it offsets, as well as the future projected grid mix for the location it is installed. In an average U.S. location, carbon payback times are less than 2 years.

carbon payback time↗

Monitoring of Photovoltaic (PV) Performance and Degradation: Integrated Renewable Energy Systems (IRES) - PV Monitoring Task

The Integrated Renewable Energy System (IRES) testbed demonstration at the Pacific Northwest National Laboratory (PNNL) Sequim campus includes development of a suite of capabilities for tracking the performance of photovoltaic (PV) renewable energy components located on a floating platform (floating PV) and on a shoreline building rooftop. The marine environment represents potentially harsh and corrosive conditions for PV modules. Compared to terrestrial PV, potential concerns for offshore PV arising from high humidity and occasional contact with saltwater, marine wildlife, and aquaculture. These environmental factors can reduce electricity generation efficiency and increase the risk of electrical faults, polymer insulation or jacketing degradation and hydrolysis of the PV cell encapsulant materials. Offshore PV modules may also be exposed to lower temperatures and buoyant and vibrating motions with a floating platform. It is not clear how the long-term performance of floating PV will be affected by these factors. To understand expected energy generation through solar cells on a floating platform, monitoring of the performance of PV modules in the marine environment is needed. This report outlines a plan for long-term testing of IRES PV components utilizing resources of the PNNL Material Aging and Detection (MAaD) Science team and the Marine and Coastal Research Laboratory (MCRL). Equipment applicable for onsite testing and real-time monitoring of the PV performance associated with environmental conditions including temperature, solar irradiance, shading and soiling is included. In case of performance loss, equipment for fault detection, failure analysis, material testing, and further troubleshooting are also available. Through establishment of this capabilities, the enabling IRES project sets the stage for future research to advance off-shore and near-shore energy options for businesses and communities.

14 SOLAR ENERGY↗

Resilience Metrics for Solar Photovoltaics

This workshop presentation proposes the development of solar photovoltaic (PV) system resilience metrics and a methodology and framework for evaluation of PV resilience metrics. PV resilience metrics are needed to establish a consistent basis for reporting, evaluation, and data collection by industry, evaluate performance of PV systems that have been subject to natural hazards, correlating resilience to system attributes, and predicting resilience for any PV system. PV resilience metrics can guide improved system design, standards, and insurance coverage. Establishing consistent metrics can foster data collection on impacts of natural hazards on PV systems.

14 SOLAR ENERGY↗

PV Inverter Systems Enabled by Monolithically Integrated SiC based Four Quadrant Power Switch (4-QPS) [BiDFET]

The purpose of this project was to develop a new breed of Power Conversion Systems (PCS) for PV integration that is enabled by the newly developed 4-Quadrant Single Die SiC Power Semiconductor Switches (4-QPS) or also referred to as “Bidirectional FET (BIDFET)”. This work includes semiconductor die development, advanced packaging, converter design, development, and testing of 4-QPS enabled hardware prototypes at 1 kW (for single phase residential application) and 10 kW (for three phase commercial application). The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four-quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs, and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. The matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac–ac and ac–dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Photovoltaic power systems for rural areas of developing countries

Photovoltaic (PV) applications for rural areas of underdeveloped countries are discussed in relation to PV system technology, reliability, and present and projected cost. The information presented is derived mainly from NASA, Lewis Research Center experience with PV systems deployed with a variety of users for applications relevant to LDCs. A detailed description of two village power systems is included. Energy cost comparisons are presented for PV systems versus alternative energy sources. It is concluded, based on present PV system technology, reliability and cost that photovoltaics provides a realistic energy option for LDCs in both the near- and far-term.

Rosenblum, L.↗