Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PTFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A conformal oxidation-resistant, plasma-polymerized coating

A comparative study was made of the surface recession (etching) of thin films of plasma polymerized tetrafluoro ethylene (PPTFE), polytetrafluoro ethylene (PTFE), and ion-beam sputter deposited polytetrafluoro ethylene (SPTFE) exposed to ground-state atomic oxygen downstream from a nonequilibrium radio-frequency O2 plasma. At 22 C, the etch rates for PTFE, SPTFE, and PPTFE were in the ratio of 8.7:1.8:1.0. A thin, conformal coating of PPTFE (etch rate of 0.3 nm/h at 22 C) was found to protect an underlying cast film of a reactive polymer, cis-1,4 polybutadiene, against ground-state atomic oxygen attack for the time required to fully etch away the PPTFE coating. From ESCA analysis, PTFE exhibited only minor surface oxidation (uptake of 0.5 atom percent O) upon etching, its F/C ratio decreasing slightly from 2.00 to 1.97; PPTFE exhibited considerable surface oxidation (uptake of 5.9 atom percent O) intermediate between those of PTFE and PPTFE, with a decrease in F/C ratio from 1.73 to 1.67. A plasma-polymerized fluorocarbon coating such as PPTFE might be useful for space applications to protect polymers that are vulnerable to oxidation or degradation by oxygen atoms.

Golub, Morton A.↗

Experimental and computational study of the microporous layer and hydrophobic treatment in the gas diffusion layer of a proton exchange membrane fuel cell

Enabling fuel cell operation at high current density is critical for developing competitive alternative power system to replace internal combustion engine. However, liquid water management continues to be a challenge for high humidity or high current density operation. Water condensation in the porous media hinders efficient oxygen transport to the catalyst layer, which in turns, reduces fuel cell performance. To improve water management capability, the gas diffusion layer is often impregnated with Polytetrafluoroethylene (PTFE) and coated with a thin microporous layer, which have shown to improve fuel cell performance, especially under wet conditions. However, the fundamental mechanism that drives the performance enhancement is still not well understood. In this work, the effects of PTFE impregnation and MPL were studied using both experimental and computational techniques. Both limiting current and polarization tests under dry and wet operating condition are conducted to study the oxygen transport resistance and fuel cell performance. In addition, a 2-D, two-phase, multi-physics PEMFC model is developed to simulate performance and gain a fundamental understanding of local water saturation and oxygen concentration. The combined results show that 5 wt% PTFE impregnation with MPL significantly enhances liquid water management, which enables higher current density operation of a fuel cell.

25 ENERGY STORAGE↗

Surface modification of cathode material enhances electrochemical performance in dry-processed Li-ion battery electrodes

The transition to electric vehicles (EVs) is pivotal for achieving energy security and integrating grid stability, with lithium-ion batteries (LIBs) playing a central role in this transformation. However, the conventional wet electrode manufacturing relying on N-methyl-2-pyrrolidone (NMP) solvent is energy intensive and costly. Dry processing (DP) has emerged as a promising alternative, eliminating solvents and using polytetrafluoroethylene (PTFE) binder for electrode fabrications. Despite its advantages, DP faces a critical challenge: poor interfacial adhesion between the hydrophobic PTFE binder and the hydrophilic cathode active material (CAM), particularly LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811), which undermines electrode performance. Here, to address this, we introduced a novel vapor-phase trimethoxymethylsilane (TMMS) coating to hydrophobize the CAM surface, enhancing compatibility with PTFE. This surface modification significantly enhances binder – CAM interactions, enabling uniform mixing and robust electrode integrity without damaging the CAM particles. Our findings advance the feasibility of environmentally sustainable and cost-effective dry processing, representing a significant step toward sustainable battery manufacturing.

Choi, Junbin [Oak Ridge National Laboratory (ORNL)↗

Fluoropolymer Composites from Partially Perfluoroalkylated Waste Polyethylene

Chemically modified plastics have emerged as practical solutions to plastic waste increases. Here, the inherent novelty of decorating polymer chains with chemical functionality results in distinct properties that expand the available application space. Nevertheless, developing designer materials for specific applications beyond compatibilization or mild property enhancement is difficult due to the synergistic effects of both the polar functionality imparted and the parent materials' intrinsic properties. By incorporating perfluoro-alkyl side-chains onto the backbone of dehydrogenated waste HDPE, unique surface properties intermediate between polytetrafluoroethylene (PTFE, the model fluoropolymer) and HDPE become apparent, while the overall material mechanical and thermal properties result in more LLDPE-like materials. This is demonstrated through moderate decreases in the surface free energy of the perfluoroalkylated polyolefin surface (increase in H 2 O contact angle of ~ 6°) and increased ordering under shear when blended with PTFE nanoparticles where the crossover point occurred at higher strains. Critically, perfluoroalkylated HDPE possesses improved rheological modification properties at elevated temperatures with PTFE nanoparticles, resulting in more thermally robust and stable composite materials.

fluoropolymer↗

Enhancing carbon dioxide gas-diffusion electrolysis by creating a hydrophobic catalyst microenvironment

Electroreduction of carbon dioxide (CO 2 ) over copper-based catalysts provides an attractive approach for sustainable fuel production. While efforts are focused on developing catalytic materials, it is also critical to understand and control the microenvironment around catalytic sites, which can mediate the transport of reaction species and influence reaction pathways. Here, we show that a hydrophobic microenvironment can significantly enhance CO 2 gas-diffusion electrolysis. For proof-of-concept, we use commercial copper nanoparticles and disperse hydrophobic polytetrafluoroethylene (PTFE) nanoparticles inside the catalyst layer. Consequently, the PTFE-added electrode achieves a greatly improved activity and Faradaic efficiency for CO 2 reduction, with a partial current density >250 mA cm -2 and a single-pass conversion of 14% at moderate potentials, which are around twice that of a regular electrode without added PTFE. The improvement is attributed to a balanced gas/liquid microenvironment that reduces the diffusion layer thickness, accelerates CO 2 mass transport, and increases CO 2 local concentration for the electrolysis.

36 MATERIALS SCIENCE↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

The Acute Inhalation Toxicity in Rats from the Pyrolysis Products of Four Fluoropolymers

Male Sprague-Dawley rats (225?250 g) were exposed to the thermal degradation products from four fluoropolymers. The three polymers containing vinylidene fluoride and hexafluoropropene (VF2/HFP) were pyrolyzed at 550? and 800?C, whereas polytetrafluoroethylene (PTFE) was pyrolyzed at 625 and 800?C. At the lower temperatures, the pyrolysate from the copolymer of vinylidene fluoride and hexafluoropropene (VF2/HFP) was less toxic than the pyrolysates from either the terpolymer of vinyidene fluoride, hexafluoropropene, and tetrafluoroethylene (VF2/HFP/TFE) or the copolymer of vinylidene fluoride and hexafluoropropene with ?additives? (VF2/HFP-A). However, the pyrolysates from the VF2/HFP-containing materials produced less toxic products than the pyrolysate from PTFE at 625?C. When the pyrolysis temperature was increased to 800?C, very little difference was noted between the pyrolysis toxicity for any of the VF2/HFP-containing polymers with the most toxic pyrolysate again produced by PTFE. Carbon monoxide levels were all sublethal. No correlation could be established between hydrolyzable fluoride levels and the lethality of the pyrolysates. Death following exposure occurred within 48 hr due to acute pulmonary edema and hemorrhage. Survival of this acute phase was followed by alveolar lymphocytic infiltration and peribronchial tissue proliferation.

Carter, V. L., Jr.↗

Transient ablation of Teflon in intense radiative and convective environments

On the basis of this investigation of the high-temperature behavior of polytetrafluoroethylene (PTFE), the transient one-dimensional ablation of PTFE has been developed by taking into account the optical transmittance of both the amorphous zone and the crystalline zone of PTFE layer. Results show that although the exposed surface receded at an apparently steady state, both the internal temperature and the thickness of the gel layer increase continuously due to the internal absorption of radiation.

Arai, N.↗

The transfer of polytetrafluoroethylene studied by X-ray photoelectron spectroscopy

A polytetrafluoroethylene (PTFE) sphere of radius 4.8 mm was rubbed against nickel and S-Monel at speeds from 0.94 to 94 mm/s and at loads from 0.19 to 3.9 N. The transfer film of PTFE on the metal was examined with X-ray photoelectron spectroscopy. In all cases the film was found to be indistinguishable from bulk PTFE. A trace of metal fluoride was observed whether the rubbing took place on oxidized or atomically clean metal. The film was of the order of a molecule thick for the entire range of loads and did not increase with repeated passes over the same rubbed area. An erratic increase in thickness at rubbing speeds above 10 mm/s was taken as evidence of random transfer of bulk material.

Wheeler, D. R.↗

Improved adhesion of Ni films on X-ray damaged polytetrafluoroethylene

The considered investigation shows that the adhesion of evaporated Ni on polytetrafluoroethylene (PTFE) is enhanced by irradiating the PTFE surface prior to evaporation. Evidence obtained with the aid of X-ray photoelectron spectroscopy is presented concerning the association of the enhanced adhesion with an interfacial chemical reaction. Evaporated Ni clearly adheres better to the X-ray damaged PTFE surface than to the undamaged surface. There is evidence that the improved adhesion is not related to the Ni-C bond, but rather to the NiF2. A possible mechanism which may be consistent with the data is the formation of a F-Ni-C complex, where C is a member of the polymer chain.

Wheeler, D. R.↗

Effect of X-ray flux on polytetrafluoroethylene in X-ray photoelectron spectroscopy

The effect of the X-ray flux in X-ray photoelectron spectroscopy (STAT) on the constitution of the polytetrafluoroethylene (PTFE) surface has been examined. The radiation dose rate for our specimen was about 10 to the 7th rad/s. The structure, magnitude and binding energy of the C(1s) and F(1s) features of the XPS spectrum and the mass spectrum of gaseous species evolved during irradiation are observed. The strong time dependence of these signals over a period of several hours indicated that the surface constitution of PTFE is greatly affected by this level of radiation dose. The results are consistent with the development of a heavily cross-linked or branched structure in the PTFE surface region and the evolution of short chain fragments into the gas phase.

Wheeler, D. R.↗

Solid spherical glass particle impingement studies of plastic materials

Erosion experiments on polymethyl methacrylate (PMMA), polycarbonate, and polytetrafluoroethylene (PTFE) were conducted with spherical glass beads impacting at normal incidence. Optical and scanning electron microscopic studies and surface profile measurements were made on specimens at predetermined test intervals. During the initial stage of damage to PMMA and polycarbonate, material expands or builds up above the original surface. However, this buildup disappears as testing progresses. Little or no buildup was observed on PTFE. PTFE is observed to be the most resistant material to erosion and PMMA the least. At low impact pressures, material removal mechanisms are believed to be similar to those for metallic materials. However, at higher pressures, surface melting is indicated at the center of impact. Deformation and fatigue appear to play major roles in the material removal process with possible melting or softening.

Rao, P. V.↗

Comparison of seal materials for use in Stirling engines

In a dry, reciprocating sliding test, rods of 12 different surface materials rubbed against a glass filled PTFE gas seal. To simulate operation in a Stirling engine a gas (N2) pressure of 1 MPa differential pressure was applied across the seal. Gas leakage rates, rods surface temperatures, changes in the surface finish of the rod, surface hardness of the rod and wear rate of the seals were measured. The rod surface materials that produced the least seal were: plasma sprayed molybdenum (75 Mo 18 Ni 4 Cr), gas nitrided steel, and plasma sprayed aluminum oxide (94 Al2O3 6 TiO2). In contrast to almost all other mating surfaces, the surface roughness of the rods coated with Mo did not decrease during wear. This property is very important for the formation of a PTFE transfer film on the mating surface. The presence of a stable transfer film gives a low PTFE wear rate.

Lundholm, G.↗

Replacement bearing for Rocketdyne SSME HPOTPs using alternate self-lubricating retainer materials

Research was conducted to develop replacement bearings for the Rocketdyne Space Shuttle main engine (SSME) high pressure oxidizer turbopumps (HPOTPs). The replacement bearings consisted of standard balls and races with a special Battelle Self-Lubricating Insert Configuration (BASIC) retainer. The BASIC retainer consists of a phosphor bronze housing with inserts consisting of a polytetrafluoretheylene (PTFE) and bronze compound. The PTFE contacts the balls and the land guiding surface on the outer race. A PTFE transfer film is formed on balls and races, which lubricates the critical interfaces. The BASIC retainer is a one-to-one replacement for the current Armalon retainer, but has superior lubricating properties and is stronger over the broad temperature range anticipated for the HPOTP bearings. As a part of the project 40 sets of balls and races (two sizes) and 52 BASIC retainers were shipped to NASA/MSFC.

Gleeson, J.↗

X-ray Photoelectron Spectroscopy Study of Argon-Plasma-Treated Fluoropolymers

Films of poly(tetrafluoroethylene) (PTFE) and of a tetrafluoroethylene-perfluoroalkyl vinyl ether (approximately 49:1) copolymer (PFA) were exposed to a radio-frequency argon plasma and then examined by X-ray photoelectron spectroscopy (XPS). The use of fluoropolymer films nearly free of surface hydrocarbon contamination as well as the use of a monochromatized X-ray source for XPS removed two factors contributing to conflicting reports on the effect of exposure time on the fluorine-to-carbon (F/C) and oxygen-to-carbon (O/C) ratios for several Ar-plasma-treated fluoropolymers. Contrary to literature indications, a common pattern was found for PTFE and PFA: a moderate decrease in F/C ratio (from 1.99 to 1.40, and from 1.97 to 1.57, respectively), together with a moderate increase in O/C ratio (from negligible to about 0.10, and from 0.012 to about O.10, respectively) at very short exposures, after which the F/C ratios remained essentially constant on prolonged exposures, while the O/C ratios for PTFE and PFA leveled off at 0.11 and 0.15, respectively. The XPS C(sub 1s), spectra for these polymers exposed to the Ar plasma for 20 min were similar and presented, besides a prominent peak at 292.0 eV (CF2,) and a minor peak at 294.0 or 294.1 eV (CF3), a composite band of four curve-resolved peaks (approximately 285-290 eV) representing various CH, CC, CO, CN, and CF functionalities.

Golub, Morton A.↗

Observation of Individual Fluorine Atom from Highly Oriented Poly (tetrafluoroethylene) Films by Atomic Force Microscopy

Direct observation of the film thickness, molecular structure and individual fluorine atoms from highly oriented poly(tetrafluoroethylene) (PTFE) films were achieved using atomic force microscopy (AFM). A thin PTFE film is mechanically deposited onto a smooth glass substrate at specific temperatures by a friction transfer technique. Atomic resolution images of these films show that the chain-like helical structures of the PTFE macromolecules are aligned parallel to each other with an intermolecular spacing of 5.72 A, and individual fluorine atoms are clearly observed along these twisted molecular chains with an interatomic spacing of 2.75 A. Furthermore, the first direct AFM measurements for the radius of the fluorine-helix, and of the carbon-helix in sub-angstrom scale are reported as 1.70 A and 0.54 A respectively.

Lee, Jonathan A.,↗

Observation of Individual Fluorine Atoms from Highly Oriented Poly(Tetrafluoroethylene) Films by Atomic Force Microscopy

Direct observation of the film thickness, molecular structure, and individual fluorine atoms from highly oriented poly(tetrafluoroethylene) (PTFE) films were achieved using atomic force microscopy (AFM). A thin PTFE film is mechanically deposited onto a smooth glass substrate at specific temperatures by a friction-transfer technique. Atomic resolution images of these films show that the chain-like helical structures of the PTFE macromolecules are aligned parallel to each other with an intermolecular spacing of 5.72 A, and individual fluorine atoms are clearly observed along these twisted molecular chains with an interatomic spacing of 2.75 A. Furthermore, the first direct AFM measurements for the radius of the fluorine-helix, and of the carbon-helix in sub-angstrom scale are reported as 1.7 and 0.54 A respectively.

Lee, J. A.↗