Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROTON SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Two-Photon-Exchange and {gamma}Z-Exchange Corrections to Parity-Violating Elastic Electron-Proton Scattering

Leading electroweak corrections play an important role in precision measurements of the strange form factors. We calculate the two-photon-exchange (TPE) and {gamma}Z-exchange corrections to the parity-violating asymmetry of the elastic electron-proton scattering in a simple hadronic model including the finite size of the proton. We find both can reach a few percent and are comparable in size with the current experimental measurements of strange-quark effects in the proton neutral weak current. The effect of {gamma}Z exchange is in general larger than that of TPE, especially at low momentum transfer Q{sup 2}{<=}1 GeV{sup 2}. Their combined effects on the values of G{sub E}{sup s}+G{sub M}{sup s} extracted in recent experiments can be as large as -40% in certain kinematics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Background Rejection of Charged Particles in the Simbol-X Telescope: Preliminary Study of Protons Scattering

X-ray telescopes equipped with focusing optics in high eccentric orbit, as e.g. Newton-XMM and Chandra, showed a degradation of the detector performance and an important increase of the noise due to soft protons with energy between a few tens of keV and a few MeV, that are focused on the detector through the mirror module. It should be noted that the focusing of the protons by Wolter optics was an unexpected phenomenon. In Simbol-X a magnetic diverter will be implemented to deflect protons, in order to reduce the flux of charged particles impinging upon the focal plane. Obviously the design of the diverter should take into consideration the protons distribution at the exit of the mirror module; for this reason a detailed simulation about the interaction of particles with the mirror surface is necessary. Here we will present the scattering protons models currently under consideration, suggesting a preliminary solution for the design of the magnetic diverter. We will also discuss an ad hoc experiment to study this problem.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Respiratory Motion on Passively Scattered Proton Therapy Versus Intensity Modulated Photon Therapy for Stage III Lung Cancer: Are Proton Plans More Sensitive to Breathing Motion?

Purpose: To quantify and compare the effects of respiratory motion on paired passively scattered proton therapy (PSPT) and intensity modulated photon therapy (IMRT) plans; and to establish the relationship between the magnitude of tumor motion and the respiratory-induced dose difference for both modalities. Methods and Materials: In a randomized clinical trial comparing PSPT and IMRT, radiation therapy plans have been designed according to common planning protocols. Four-dimensional (4D) dose was computed for PSPT and IMRT plans for a patient cohort with respiratory motion ranging from 3 to 17 mm. Image registration and dose accumulation were performed using grayscale-based deformable image registration algorithms. The dose–volume histogram (DVH) differences (4D-3D [3D = 3-dimensional]) were compared for PSPT and IMRT. Changes in 4D-3D dose were correlated to the magnitude of tumor respiratory motion. Results: The average 4D-3D dose to 95% of the internal target volume was close to zero, with 19 of 20 patients within 1% of prescribed dose for both modalities. The mean 4D-3D between the 2 modalities was not statistically significant (P<.05) for all dose–volume histogram indices (mean ± SD) except the lung V5 (PSPT: +1.1% ± 0.9%; IMRT: +0.4% ± 1.2%) and maximum cord dose (PSPT: +1.5 ± 2.9 Gy; IMRT: 0.0 ± 0.2 Gy). Changes in 4D-3D dose were correlated to tumor motion for only 2 indices: dose to 95% planning target volume, and heterogeneity index. Conclusions: With our current margin formalisms, target coverage was maintained in the presence of respiratory motion up to 17 mm for both PSPT and IMRT. Only 2 of 11 4D-3D indices (lung V5 and spinal cord maximum) were statistically distinguishable between PSPT and IMRT, contrary to the notion that proton therapy will be more susceptible to respiratory motion. Because of the lack of strong correlations with 4D-3D dose differences in PSPT and IMRT, the extent of tumor motion was not an adequate predictor of potential dosimetric error caused by breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-photon exchange from intermediate state resonances in elastic electron-proton scattering

In this paper, we use a recently developed dispersive approach to compute the two-photon exchange (TPE) correction to elastic electron-proton scattering, including contributions from hadronic $J^P=1/2^\pm$ and $3/2^\pm$ resonant intermediate states below~1.8~GeV. For the transition amplitudes from the proton ground state to the resonant excited states we employ new exclusive meson electroproduction data from CLAS at $Q^2 \lesssim 5$~GeV$^2$, and we explore the effects of both fixed and dynamic widths for the resonances. Among the resonant states, the $N(1520)~\!3/2^-$ becomes dominant for $Q^2 \gtrsim 2$~GeV$^2$, with a sign opposite to the comparably sized $\Delta(1232)~\!3/2^+$ contribution, leading to an overall increase in the size of the TPE correction to the cross section relative to the nucleon only contribution at higher $Q^2$ values. The results are in good overall agreement with recent $e^+ p$ to $e^- p$ cross section ratio and polarization transfer measurements, and provide compelling evidence for a resolution of the electric to magnetic form factor ratio discrepancy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contribution of two-boson exchange with {delta}(1232) excitation to parity-violating elastic electron-proton scattering

We study the leading electroweak corrections in the precision measurement of the strange form factors. Specifically, we calculate the two-boson exchange (TBE), two-photon exchange (TPE) plus {gamma}Z exchange ({gamma}ZE), and corrections with {delta}(1232) excitation to the parity-violating asymmetry of the elastic electron-proton scattering. The interplay between nucleon and {delta} contributions is found to depend strongly on the kinematics, as {delta}{sub {delta}} begins as negligible at backward angles but becomes very large and negative and dominant at forward angles, while {delta}{sub N} always stays positive and decreases monotonically with increasing {epsilon}. The total TBE corrections to the extracted values of G{sub E}{sup s}+{beta}G{sub M}{sup s} in recent experiments of HAPPEX and G0 are, depending on kinematics, found to be large and range between 13% and -75%, but are found to be small in the case of A4 experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-photon exchange in elastic electron–proton scattering

Here, we review recent theoretical and experimental progress on the role of two-photon exchange (TPE) in electron-proton scattering at low to moderate momentum transfers. We make a detailed comparison and analysis of the results of competing experiments on the ratio of e + p to e - p elastic scattering cross sections, and of the theoretical calculations describing them. A summary of the current experimental situation is provided, along with an outlook for future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-BRC-05: Effects of Motion and Variable RBE in a Lung Patient Treated with Passively Scattered Protons

Purpose: To evaluate effects of motion and variable relative biological effectiveness (RBE) in a lung cancer patient treated with passively scattered proton therapy using dose volume histograms associated with patient dose computed using three different methods. Methods: A proton treatment plan of a lung cancer patient optimized using clinical treatment planning system (TPS) was used to construct a detailed Monte Carlo (MC) model of the beam delivery system and the patient specific aperture and compensator. A phase space file containing all particles transported through the beam line was collected at the distal surface of the range compensator and subsequently transported through two different patient models. The first model was based on the average CT used by the TPS and the second model included all 10 phases of the corresponding 4DCT. The physical dose and proton linear energy transfer (LET) were computed in each voxel of two models and used to compute constant and variable RBE MC dose on average CT and 4D CT. The MC computed doses were compared to the TPS dose using dose volume histograms for relevant structures. Results: The results show significant differences in doses to the target and critical structures suggesting the need for more accurate proton dose computation methods. In particular, the 4D dose shows reduced coverage of the target and higher dose to the spinal cord, while variable RBE dose shows higher lung dose. Conclusion: The methodology developed in this pilot study is currently used for the analysis of a cohort of ∼90 lung patients from a clinical trial comparing proton and photon therapy for lung cancer. The results from this study will help us in determining the clinical significance of more accurate dose computation models in proton therapy.

60 APPLIED LIFE SCIENCES↗

Measuring the Weak Charge of the Proton via Elastic Electron-Proton Scattering

The Qweak experiment which ran in Hall C at Jefferson Lab in Newport News, VA, and completed data taking in May 2012, measured the weak charge of the proton Q p W via elastic electron-proton scattering. Longitudinally polarized electrons were scattered from an unpolarized liquid hydrogen target. The helicity of the electron beam was flipped at approximately 1 kHz between left and right spin states. The Standard Model predicts a small parity-violating asymmetry of scattering rates between right and left helicity states due to the weak interaction. An initial result using 4% of the data was published in October 2013 [1] with a measured parity-violating asymmetry of -279 ± 35(stat) ± 31 (syst) ppb. This asymmetry, along with other data from parity-violating electron scattering experiments, provided the world's first determination of the weak charge of the proton. The weak charge of the proton was found to be p W = 0.064 ± 0.012, in good agreement with the Standard Model prediction of p W (SM) = 0.0708 ± 0.0003[2].

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ab initio leading order effective potential for elastic proton scattering based on the symmetry-adapted no-core shell model

Calculating microscopic optical potentials for elastic scattering at intermediate energies from light nuclei in an ab initio fashion within the Watson expansion has been established within the last few years. Based on the Watson expansion of the multiple scattering series, we employ a nonlocal translationally invariant nuclear density derived within the symmetry-adapted no-core shell model (SA-NCSM) framework from a chiral next-to-next-to-leading order (NNLO) nucleon-nucleon interaction and the very same interaction for a consistent full-folding calculation of the effective (optical) potential for nucleon-nucleus scattering for medium-heavy nuclei. The leading order effective (optical) folding potential is computed by integrating over a translationally invariant SA-NCSM one-body scalar density, spin-projected momentum distribution, and the Wolfenstein amplitudes 𝐴, 𝐶, and 𝑀. The resulting nonlocal potentials serve as input for a momentum space Lippmann-Schwinger equation. In the SA-NCSM, the model space is systematically up-selected using Sp⁡(3,ℝ) symmetry considerations. For the light nucleus of 6 He, we establish a systematic selection scheme in the SA-NCSM for scattering observables. Then, we apply this scheme to calculations of scattering observables, such as differential cross sections, analyzing powers, and spin rotation functions for elastic proton scattering from 20 Ne and 40 Ca in the energy regime between 65 and 200 MeV, and compare to available data. Furthermore, our calculations show that the leading order effective nucleon-nucleus potential in the Watson expansion of multiple scattering theory obtained from an up-selected SA-NCSM model space describes 40 Ca elastic scattering observables reasonably well to about 60 degrees in the center-of-mass frame, which coincides roughly with the validity of the NNLO chiral interaction used to calculate both the nucleon-nucleon amplitudes and the one-body scalar and spin nuclear densities.

Ab initio calculations↗

Low-lying states in {sup 32}Mg studied by proton inelastic scattering

Proton inelastic scattering on the neutron-rich nucleus {sup 32}Mg has been studied at 46.5 MeV/nucleon in inverse kinematics. Populated states were identified by measuring de-excitation {gamma} rays, in which five new states were found by {gamma}-{gamma} coincidence analyses. By analyzing the angular differential cross sections via coupled-channel calculations, their spins and parities were constrained and the amplitudes for each transition were extracted. The spin and parity of the 2321-keV state was assigned as 4{sub 1}{sup +}. The ratio between the energies of the 2{sub 1}{sup +} and 4{sub 1}{sup +} states indicates that {sup 32}Mg is a transitional nucleus rather than an axially deformed rigid rotor. The collectivities in the nucleus {sup 32}Mg with N=20 are discussed based on the results obtained in the present experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-246: MU Model Implementation for a Passively Scattered Proton Beam: Inclusion of the Bolus Gap and Nozzle Extension Factors

Purpose: To develop and implement an MU model for a passively scattered proton beam, and eliminate the need for patient specific calibrations for field sizes from 3cm to 15cm. This would enable consistent and timely calibrations for a wide variety of patient portals, streamlining the treatment process. Methods: Measurements were initially made using a Standard Imaging A-16 ion chamber and a modified water tank to determine the bolus gap factors (BGF) for multiple combinations of aperture size, bolus thickness, and air gap. The BGF was then separated into two component factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Polynomial curves were generated using the measured data to produce BTF tables for air gaps from 0cm to 30cm and for bolus thicknesses from 0cm to 10cm, and NEF tables for the full range of clinically used nozzle extensions. Additionally, data tables were created for every factor that affects beam output in the MU model. The MUs were then modeled for 487 patient portals and retrospectively compared to the MUs generated from the physical calibrations previously performed. Results: Of the 487 patient portals tested, 100% of the portals used for the comparison were within 2.5% from the MUs generated using a physical calibration, and 95.9% of the MU model portals tested were within 2%. The patient portals tested had field sizes ranging from 2.1cm to 10.1cm, with air gaps from 2cm to 25cm. Output factors for field sizes below 3cm with irregularly shaped fields demonstrated inconsistent results and will be further studied. Conclusion: The most problematic output factor, the BGF, was modeled accurately and consistently using the lowest order polynomial curve fits and interpolation between measured data. The study results demonstrate the robustness of the MU model and the potential for saving valuable personnel and beam time.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of groomed event shape observables in deep-inelastic electron-proton scattering at HERA

The H1 Collaboration at HERA reports the first measurement of groomed event shape observables in deep inelastic electron-proton scattering (DIS) at $\sqrt{s} =319$ GeV, using data recorded between the years 2003 and 2007 with an integrated luminosity of 351 pb -1 . Event shapes provide incisive probes of perturbative and non-perturbative QCD. Grooming techniques have been used for jet measurements in hadronic collisions; this paper presents the first application of grooming to DIS data. The analysis is carried out in the Breit frame, utilizing the novel Centauro jet clustering algorithm that is designed for DIS event topologies. Events are required to have squared momentum-transfer $Q^2 > 150$ GeV 2 and inelasticity $0.2< y < 0.7$. We report measurements of the production cross section of groomed event 1-jettiness and groomed invariant mass for several choices of grooming parameter. Monte Carlo model calculations and analytic calculations based on Soft Collinear Effective Theory are compared to the measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-61: A Practical Process for Fabricating Passive Scatter Proton Beam Modulation Compensation Filters Using 3D Printing

Purpose: The purpose of this project was to devise a practical fabrication process for passive scatter proton beam compensation filters (CF) that is competitive in time, cost and effort using 3D printing. Methods: DICOM compensator filter files for a proton beam were generated by our Eclipse (Varian, Inc.) treatment planning system. The compensator thickness specifications were extracted with in-house software written in Matlab (MathWorks, Inc.) code and written to a text file which could be read by the Rhinoceros 5, computer-aided design (CAD) package (Robert McNeel and Associates), which subsequently generated a smoothed model in a STereoLithographic also known as a Standard Tesselation Language file (STL). The model in the STL file was subsequently refined using Netfabb software and then converted to printing instructions using Cura. version 15.02.1. for our 3D printer. The Airwolf3D, model HD2x, fused filament fabrication (FFF) 3D printer (Airwolf3D.com) was used for our fabrication system with a print speed of 150mm per second. It can print in over 22 different plastic filament materials in a build volume of 11” x 8” x 12”. We choose ABS plastic to print the 3D model of the imprint for our CFs. Results: Prints of the CF could be performed at a print speed of 70mm per second. The time to print the 3D topology for the CF for the 14 cm diameter snout of our Mevion 250 proton accelerator was less than 3 hours. The printed model is intended to subsequently be used as a mold to imprint a molten wax cylindrical to form the compensation after cooling. The whole process should be performed for a typical 3 beam treatment plan within a day. Conclusion: Use of 3D printing is practical and can be used to print a 3D model of a CF within a few hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron-proton scattering at next-to-next-to-leading order in Nuclear Lattice Effective Field Theory

Here, we present a systematic study of neutron-proton scattering in Nuclear Lattice Effective Field Theory (NLEFT), in terms of the computationally efficient radial Hamiltonian method. Our leading-order (LO) interaction consists of smeared, local contact terms and static one-pion exchange. We show results for a fully non-perturbative analysis up to next-to-next-to-leading order (NNLO), followed by a perturbative treatment of contributions beyond LO. The latter analysis anticipates practical Monte Carlo simulations of heavier nuclei. We explore how our results depend on the lattice spacing a, and estimate sources of uncertainty in the determination of the low-energy constants of the next-to-leading-order (NLO) two-nucleon force. We give results for lattice spacings ranging from a = 1.97 fm down to a = 0.98 fm, and discuss the effects of lattice artifacts on the scattering observables. At a = 0.98 fm, lattice artifacts appear small, and our NNLO results agree well with the Nijmegen partial-wave analysis for S-wave and P-wave channels. We expect the peripheral partial waves to be equally well described once the lattice momenta in the pion-nucleon coupling are taken to coincide with the continuum dispersion relation, and higher-order (N 3 LO) contributions are included. Finally, we stress that for center-of-mass momenta below 100 MeV, the physics of the two-nucleon system is independent of the lattice spacing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Elastic proton-proton scattering at RHIC

Here we describe elastic proton+proton (p+p) scattering measurements at RHIC in p+p collisions with a special optics run of {beta}* {approx} 21 m at STAR, at the center-of-mass energy {radical}s = 200 GeV during the last week of the RHIC 2009 run. We present preliminary results of single and double spin asymmetries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton scattering in the region near the earth's bow shock.

Lockheed spectrometer data from orbits 1 through 20 of Ogo 5 are used to study proton scattering near the bow shock. Correlative UCLA fluxgate magnetometer data from the satellite are used to complete motion studies of the bow shock when spectrometer data are missing. Thirty-eight analyzable sets of multiple shock crossings show 358 shock encounters ranging from 10 to 22 earth radii and spanning sun-earth-satellite angles from 30 to 90 deg. Gross features of the study show that the location and shape of the bow shock are in good agreement with the hydrodynamic model of the bow shock.

Ossakow, S. L.↗

SU-E-T-239: Design and Evaluation of a Nozzle Shielding System in Passively Scattered Proton Therapy

Purpose: To design, implement and evaluate a shielding system that will reduce out-of-field dose experienced by the patient and associated electronic systems in passively scattered proton therapy treatment. Methods: A multi-stage neutron shielding system was retrofitted to the Gantry 1 treatment nozzle at Loma Linda University Medical Center. The system uses multiple borated polyethylene plates staged after the primary beam modifying devices to attenuate and absorb neutrons produced by such devices. This arrangement locates increasing levels of shielding between the sources of secondary particles in the nozzle and the patient. Additionally, the design of this shielding structure allows it to be easily retrofitted to an existing proton nozzle system without impacting design or treatment beam characteristics. The effectiveness of the shielding was evaluated both through experimental measurements and Geant4 Monte Carlo simulations. Results: Measurements were completed with Landauer Luxel+ dosimeters that use optically stimulated luminescence and CR-39 to detect fast neutrons, thermal neutrons, protons, photons and beta particles. Measurements of a 250 MeV proton beam indicated that the shielding system reduced out-of-field dose to the patient by almost half with dose equivalent values at 50 and 40 cm from the field edge decreasing from 0.965 and 1.262 mSv/Gy to 0.596 and 0.777 mSv/Gy respectively. The installation of the multi-stage shielding system also reduced dose equivalent experienced by electronic systems installed in the treatment room by up to 80%. Geant4 simulations were also used to evaluate the neutron fluence at various positions in the treatment room as well as provide information on microdosimetry spectra within the patient and treatment room. Conclusion: The shielding system described above proved to be an effective an inexpensive method of reducing out-of-field doses to the patient and electronic systems and can be easily retrofitted to existing passive scattering nozzles.

60 APPLIED LIFE SCIENCES↗

SU-F-T-137: Out-Of-Beam Dose for a Compact Double-Scattering Proton Beam Therapy System

Purpose: The out-of-beam dose is important for understanding the peripheral dose in radiation therapy. In proton radiotherapy, the study of out-of-beam dose is scarce and the treatment planning system (TPS) based on pencil beam algorithm cannot accurately predict the out-of-beam dose. This study investigates the out-of-beam dose for the single-room Mevion S250 double scattering proton therapy system using experimentally measured and treatment planning software generated data. The results are compared with those reported for conventional photon beam therapy. However, this study does not incorporate the neutron contribution in the scattered dose. Methods: A total of seven proton treatment plans were generated using Varian Eclipse TPS for three different sites (brain, lung, and pelvis) in an anthropomorphic phantom. Three field sizes of 5×5, 10×10, and 20×20 cm{sup 2} (lung only) with typical clinical range (13.3–22.8 g/cm{sup 2}) and modulation widths (5.3–14.0 g/cm{sup 2}) were used. A single beam was employed in each treatment plan to deliver a dose of 181.8 cGy (200.0 cGy (RBE)) to the selected target. The out-of-beam dose was measured at 2.0, 5.0, 10.0, and 15.0 cm from the beam edge in the phantom using a thimble chamber (PTW TN31010). Results: The out-of-beam dose generally increased with field size, range, and volume irradiated. For all the plans, the scattered dose sharply fell off with distance. At 2.0 cm, the out-of-beam dose ranged from 0.35% to 2.16% of the delivered dose; however, the dose was clinically negligible (<0.3%) at a distance of 5.0 cm and greater. In photon therapy, the slightly greater out-of-beam dose was reported (TG36; 4%, 2%, and 1% for 2.0, 5.0, and 10.0 cm, respectively, using 6 MV beam). Conclusion: The measured out-of-beam dose in proton therapy excluding neutron contribution was observed higher than the TPS calculated dose and comparable to that of photon beam therapy.

60 APPLIED LIFE SCIENCES↗