Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Photocopia-A Unibody Mono-material Compact and Scalable Photomultiplier

The Photocopia photomultiplier tube (PMT) takes advantage of two of the many unique properties of the hydrogenated amorphous silicon-germanium (a-SiGe) photoemitter material: its mechanical flexibility and mostly substrate-independent properties. The a-SiGe photoemitter has high secondary electron (SE) yield. It can be used both as the photocathode and as the gain medium. The active material can be grown on a flat, thin unibody substrate, formed and then “rolled up” ex situ. The completed structure would then be activated and sealed within a tube. The Ge component can be increased to enhance red-sensitivity. Compact sizes are possible, minimizing magnetic field effects. The Photocopia PMT will be a low cost alternative to MCPs for TOF detectors and provide better timing discrimination for Cherenkov detectors. Retention of the ability to activate to a normal photoyield state upon flexing (bending) the substrate of the a-SiGe material after growth, but prior to activation has been shown. The SE coefficient of the activated material has been characterized over the voltage range suitable for utilization as the gain material. The time response of the material is suited to PMT use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Massive Pulmonary Embolism: Treatment with the Rotarex Thrombectomy System

This study was designed to evaluate the efficacy and safety of percutaneous mechanical thrombectomy (PMT) for acute massive pulmonary embolism (PE). Fourteen patients (8 men, 6 women) with a mean age of 55.4 (range, 38-71) years with acute massive PE were initially diagnosed by computed tomography (CT) and confirmed by pulmonary angiography. All patients presented with acute PE symptoms and hemodynamic compromise. Each patient was treated with Straub Rotarex thrombectomy device and five patients received additional thrombolysis. Technique success and clinical improvement were achieved in all patients without major complications. The mean pulmonary artery pressure (PAP) decreased from 37.6 {+-} 6.6 to 29 {+-} 6.4 mmHg (P < 0.01) after PMT. Partial arterial pressures of O{sub 2} (PaO{sub 2}) increased from 61.1 {+-} 9.2 to 88 {+-} 5.1 mmHg (P < 0.01). The Miller index was 0.67 {+-} 0.11 and 0.37 {+-} 0.13 (P < 0.01), respectively, before and after PMT (P < 0.01). Eleven patients had no recurrence of PE on a mean follow-up of 28.3 months, whereas the other three patients were lost to follow-up. The preliminary experience in our series suggests that the Straub Rotarex thrombectomy device, which has been utilized in peripheral arteries, also is useful for the treatment of acute massive PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers

Pulse shape discrimination (PSD) techniques can be used to discern between neutron and gamma-ray interactions in certain organic scintillators. Traditionally, photomultiplier tubes (PMTs) have been used in organic-scintillator assemblies. However, silicon photomultipliers (SiPMs) have great potential to be used in many applications in which PMTs have been predominantly used, including those utilizing PSD techniques. To evaluate the current state of the art of the SiPM technology, SensL's 6-mm B-Series and C-Series SiPMs were compared to a fast Hamamatsu PMT in conjunction with a 6×6×6-mm3 stilbene organic scintillator to assess the PSD performance of the detector assemblies. Measurements with a Cf-252 source were performed and a figure of merit (FOM) for discriminating between neutron and gamma-ray pulses between 100 keVee and 200 keVee was calculated for each assembly. A digital charge-integration PSD technique was used to process all measured data. The FOM for the B-Series SiPM, PMT, and C-Series SiPM was 1.37, 1.93, and 2.13, respectively. The C-Series SiPM was shown to perform as well as the PMT in the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Organic Scintillator Detector Response Simulations with DRiFT

Here, this work presents the organic scintillation simulation capabilities of DRiFT, a post-processing Detector Response Function Toolkit for MCNPR output. DRiFT is used to create realistic scintillation detector response functions to incident neutron and gamma mixed- field radiation. As a post-processing tool, DRiFT leverages the extensively validated radiation transport capabilities of MCNPR ® 6, which also provides the ability to simulate complex sources and geometries. DRiFT is designed to be flexible, it allows the user to specify scintillator material, PMT type, applied PMT voltage, and quenching data used in simulations. The toolkit's capabilities, which include the generation of pulse shape discrimination plots and full-energy detector spectra, are demonstrated in a comparison of measured and simulated neutron contributions from 252 Cf and PuBe, and photon spectra from 22 Na and 228 Th sources. DRiFT reproduced energy resolution effects observed in EJ-301 measurements through the inclusion of scintillation yield variances, photon transport noise, and PMT photocathode and multiplication noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronics of the energy plane of the NEXT-White detector

This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterráneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit -1 in the chain of 214 Bi . All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4 mV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure, Function and Inhibition of the Phosphoethanolamine Methyltransferases of the Human Malaria Parasites Plasmodium vivax and Plasmodium knowlesi

Phosphoethanolamine methyltransferases (PMTs) catalyze the three-step methylation of phosphoethanolamine to form phosphocholine, a critical step in the synthesis of phosphatidylcholine in a select number of eukaryotes including human malaria parasites, nematodes and plants. Genetic studies in the malaria parasite Plasmodium falciparum have shown that the methyltransferase PfPMT plays a critical function in parasite development and differentiation. The presence of PMT orthologs in other malaria parasites that infect humans and their absence in mammals make them ideal targets for the development of selective antimalarials with broad specificity against different Plasmodium species. Here we describe the X-ray structures and biochemical properties of PMT orthologs from Plasmodium vivax and Plasmodium knowlesi and show that both enzymes are inhibited by amodiaquine and NSC158011, two drugs with potent antimalarial activity. Metabolic studies in a yeast mutant that relies on PkPMT or PvPMT for survival demonstrated that these compounds inhibit phosphatidylcholine biosynthesis from ethanolamine. Our structural and functional data provide insights into the mechanism of catalysis and inhibition of PMT enzymes and set the stage for a better design of more specific and selective antimalarial drugs.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging photomultiplier array with integrated amplifiers and high-speed USB interface

Multianode photomultiplier tube (PMT) arrays are finding application as convenient high-speed light sensitive devices for plasma imaging. This paper describes the development of a USB-based 'plug-n-play' 16-channel PMT camera with 16 bits simultaneous acquisition of 16 signal channels at rates up to 2 MS/s per channel. The preamplifiers and digital hardware are packaged in a compact housing which incorporates magnetic shielding, on-board generation of the high-voltage PMT bias, an optical filter mount and slits, and F-mount lens adaptor. Triggering, timing, and acquisition are handled by four field-programmable gate arrays (FPGAs) under instruction from a master FPGA controlled by a computer with a LABVIEW interface. We present technical design details and specifications and illustrate performance with high-speed images obtained on the H-1 heliac at the ANU.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusion neutron detector for time-of-flight measurements in z-pinch and plasma focus experiments

We have developed and tested sensitive neutron detectors for neutron time-of-flight measurements in z-pinch and plasma focus experiments with neutron emission times in tens of nanoseconds and with neutron yields between 10{sup 6} and 10{sup 12} per one shot. The neutron detectors are composed of a BC-408 fast plastic scintillator and Hamamatsu H1949-51 photomultiplier tube (PMT). During the calibration procedure, a PMT delay was determined for various operating voltages. The temporal resolution of the neutron detector was measured for the most commonly used PMT voltage of 1.4 kV. At the PF-1000 plasma focus, a novel method of the acquisition of a pulse height distribution has been used. This pulse height analysis enabled to determine the single neutron sensitivity for various neutron energies and to calibrate the neutron detector for absolute neutron yields at about 2.45 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coincidence ion imaging with a fast frame camera

A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal pulse emulation for scintillation detectors using Geant4 Monte Carlo with light tracking simulation

The anode pulse of a photomultiplier tube (PMT) coupled with a scintillator is used for pulse shape discrimination (PSD) analysis. We have developed a novel emulation technique for the PMT anode pulse based on optical photon transport and a PMT response function. The photon transport was calculated using Geant4 Monte Carlo code and the response function with a BC408 organic scintillator. The obtained percentage RMS value of the difference between the measured and simulated pulse with suitable scintillation properties using GSO:Ce (0.4, 1.0, 1.5 mol%), LaBr{sub 3}:Ce and BGO scintillators were 2.41%, 2.58%, 2.16%, 2.01%, and 3.32%, respectively. The proposed technique demonstrates high reproducibility of the measured pulse and can be applied to simulation studies of various radiation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light propagation in a neutron detector based on 6 Li glass scintillator particles in an organic matrix

Composite materials consisting of 6 Li scintillator particles in an organic matrix can enable thermal neutron detectors with excellent rejection of gamma-ray backgrounds. The efficiency of transporting scintillation light through such a composite is critical to the detector performance. This optical raytracing study of a composite thermal neutron detector quantifies the various sources of scintillation light loss and identifies favorable photomultiplier tube (PMT) readout schemes. The composite material consisted of scintillator cubes within an organic matrix shaped as a right cylinder. The cylinder surface was surrounded by an optical reflector, and the light was detected by PMTs attached to the cylinder end faces. A reflector in direct contact with the composite caused 53% loss of scintillation light. This loss was reduced 8-fold by creating an air gap between the composite and the reflector to allow a fraction of the scintillation light to propagate by total internal reflection. Replacing a liquid mineral oil matrix with a solid acrylic matrix decreased the light transport efficiency by only ~10% for the benefit of creating an all-solid-state device. The light propagation loss was found to scale exponentially with the distance between the scintillation event and the PMT along the cylinder main axis. This enabled a PMT readout scheme that corrects for light propagation loss on an event-by-event basis and achieved a 4.0% energy resolution that approached Poisson-limited performance. These results demonstrate that composite materials can enable practical thermal neutron detectors for a wide range of nuclear non-proliferation and safeguard applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

Search for direct detection of thorium-229m nuclear VUV photons

We used two methods to attempt to measure the lifetime and energy level of the 229m Th low-lying nuclear state. Both methods used a 233 U source to implant 229 Th into a VUV transparent substrate. The uranium source had a low concentration of 232 U (0.08 ppm) and was chemically purified one week prior to the start of the experiment. In the first method, the time decay method, sensitive to 229m Th lifetimes from 10 min to 15 h, the VUV substrate was irradiated for 4–36 h to ensure a sufficient transfer of 229m Th ions into the substrate. Then the signal from the substrate was observed using a PMT for 15 h. A bandpass filter was placed between the substrate and PMT to provide a means of measuring the 229m Th photon energy. We used nine filters with center transmissions ranging from 140 to 244 nm. In the second method, direct detection, sensitive to lifetimes from zero to 10 min, the substrate was observed directly with the PMT and filter during the deposition process. For both methods our results were limited by the strong background fluorescence and phosphorescence due to the alphas and betas intrinsic to the decay of the 233 U and its daughters. We did not see unambiguous signs of photons from 229m Th. This may be due to one or more of the following: lifetime of 229m Th too short or too long, branching ratio to produce 229m Th from 233 U is too small, energy of 229m Th transition is outside of our observed range of 5.1–8.9 eV, and/or most likely, 229m Th ions drop to a +1 or 0 charge state, and thus lose their nuclear excitation through non-radiative processes.

229Th↗

Simulations for the global quantum efficiency of MicroBooNE optical units

The MicroBooNE detector uses scintillation light from particle interactions in liquid argon as a data acquisition trigger. This scintillation light has wavelengths in the vacuum ultra violet (VUV) range, and must be converted into visible light to be detected by photomultiplier tubes (PMTs). To convert the light, MicroBooNE uses wavelength shifting plates coated with Tetraphenyl butadiene (TPB) placed in front of its PMTs. While basic tuning of this plate-PMT system is sufficient for triggering, precise calibration of the system makes additional calorimetry possible. This note will outline how a photon simulation which accounts for the geometry and optical details of the MicroBooNE detector can accompany a measurement of observed photoelectrons in a plate-PMT test stand, and how the results may be used to determine a "global quantum efficiency" for the plate-PMT system. This global quantum efficiency is one required ingredient for improving the capabilities of the light collection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of the neutron detection efficiency and response characteristics of two pixelated PSD-capable organic scintillator detectors with different photo-detection readout methods

Here, we characterize the performance of two pixelated neutron detectors: a PMT-based array that utilizes Anger logic for pixel identification and a SiPM-based array that employs individual pixel readout. The SiPM-based array offers improved performance over the previously developed PMT-based detector both in terms of uniformity and neutron detection efficiency. Each detector array uses PSD-capable plastic scintillator as a detection medium. We describe the calibration and neutron efficiency measurement of both detectors using a 137 Cs source for energy calibration and a 252 Cf source for calibration of the neutron response. We find that the intrinsic neutron detection efficiency of the SiPM-based array is (30.2 ± 0.9)%, which is almost twice that of the PMT-based array, which we measure to be (16.9 ± 0.1)%.

47 OTHER INSTRUMENTATION↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Photomultiplier tube failure under hydrostatic pressure in future neutrino detectors

Failure of photomultiplier tubes (PMTs) under hydrostatic pressure is a concern in neutrino detection, specifically, in the proposed Long-Baseline Neutrino Experiment project. Controlled hydrostatic implosion tests were performed on prototypic PMT bulbs of 10-inch diameter and recorded using high speed filming techniques to capture failures in detail. These high-speed videos were analyzed frame-by-frame in order to identify the origin of a crack, measure the progression of individual crack along the surface of the bulb as it propagates through the glass, and estimate crack velocity. Crack velocity was calculated for each individual crack, and an average velocity was determined for all measurable cracks on each bulb. Overall, 32 cracks were measured in 9 different bulbs tested. Finite element modeling (FEM) of crack formation and growth in prototypic PMT shows stress concentration near the middle section of the PMT bulbs that correlates well with our crack velocity measurements in that section. The FEM model predicts a crack velocity value that is close to the terminal crack velocity reported. Our measurements also reveal significantly reduced crack velocities compared to terminal crack velocities measured in glasses using fracture mechanics testing and reported in literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗