Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUTONIUM 240”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Reference material manufacture and certification for the AVNG

Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. The AVNG implementation that we describe is an attribute measurement system built by RFNC - VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass > 2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' The AVNG was tested using a number of reference material (RM) sources with masses and isotopic ratios above and below these thresholds. The AVNG was demonstrated in June 2009 using several of these sources in addition to detector calibration sources. Since the AVNG was designed to measure multi-kg plutonium sources, the RM was manufactured specifically for use with this system. In addition, the RM was used to test the thresholds in the AVNG, so the size and composition of each RM was certified prior to use. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The design and implementation of the AVNG measurement system

An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By displaying these unclassified results only as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG that we describe is an AMS built by RFNC-VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' In this presentation, we will describe the design of the AVNG neutron and gamma detector subsystems, as well as the design of the entire AMS incorporating these detectors. We will also describe the construction of the AVNG and the final design that was demonstrated in June 2009.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AVNG system objectives and concept

Any verification measurement performed on potentially classified nuclear material must satisfy two constraints. First and foremost, no classified information can be released to the monitoring party. At the same time, the monitoring party must gain sufficient confidence from the measurement to believe that the material being measured is consistent with the host's declarations concerning that material. The attribute measurement technique addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The AVNG that we describe is an attribute measurement system built by RFNC-VNIIEF in Sarov, Russia. The AVNG measures the three attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) <0.1' and was demonstrated in Sarov for a joint US/Russian audience in June 2009. In this presentation, we will outline the goals and objectives of the AVNG measurement system. These goals are driven by the two, sometimes conflicting, requirements mentioned above. We will describe the conceptual design of the AVNG and show how this conceptual design grew out of these goals and objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmark Evaluation of Plutonium Nitrate Solution Arrays

In October and November of 1981 thirteen approach-to-critical experiments were performed on a remote split table machine (RSTM) in the Critical Mass Laboratory of Pacific Northwest Laboratory (PNL) in Richland, Washington, using planar arrays of polyethylene bottles filled with plutonium (Pu) nitrate solution. Arrays of up to sixteen bottles were used to measure the critical number of bottles and critical array spacing with a tight-fitting Plexiglas® reflector on all sides of the arrays except the top. Some experiments used Plexiglas shells fitted around each bottle to determine the effect of moderation on criticality. Each bottle contained approximately 2.4 L of Pu(NO 3 ) 4 solution with a Pu content of 105 g Pu/L and a free acid molarity H+ of 5.1. The plutonium was of low 240 Pu (2.9 wt.%) content. These experiments were performed to fill a gap in experimental data regarding criticality limits for storing and handling arrays of Pu solution in reprocessing facilities. Of the thirteen approach-to-critical experiments eleven resulted in extrapolations to critical configurations. Four of the approaches were extrapolated to the critical number of bottles; these were not evaluated further due to the large uncertainty associated with the modeling of a fraction of a bottle. The remaining seven approaches were extrapolated to critical array spacing of 3-4 and 4-4 arrays; these seven critical configurations were evaluation for inclusion as acceptable benchmark experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Arrays of Bottles of Plutonium Nitrate Solution

In October and November of 1981 thirteen approaches-to-critical were performed on a remote split table machine (RSTM) in the Critical Mass Laboratory of Pacific Northwest Laboratory (PNL) in Richland, Washington using planar arrays of polyethylene bottles filled with plutonium (Pu) nitrate solution. Arrays of up to sixteen bottles were used to measure the critical number of bottles and critical array spacing with a tight fitting Plexiglas® reflector on all sides of the arrays except the top. Some experiments used Plexiglas shells fitted around each bottles to determine the effect of moderation on criticality. Each bottle contained approximately 2.4 L of Pu(NO 3 ) 4 solution with a Pu content of 105 g Pu/L and a free acid molarity H + of 5.1. The plutonium was of low 240 Pu (2.9 wt.%) content. These experiments were sponsored by Rockwell Hanford Operations because of the lack of experimental data on the criticality of arrays of bottles of Pu solution such as might be found in storage and handling at the Purex Facility at Hanford. The results of these experiments were used “to provide benchmark data to validate calculational codes used in criticality safety assessments of [the] plant configurations” (Ref. 1). Data for this evaluation were collected from the published report (Ref. 1), the approach to critical logbook, the experimenter’s logbook, and communication with the primary experimenter, B. Michael Durst. Of the 13 experiments preformed 10 were evaluated. One of the experiments was not evaluated because it had been thrown out by the experimenter, one was not evaluated because it was a repeat of another experiment and the third was not evaluated because it reported the critical number of bottles as being greater than 25. Seven of the thirteen evaluated experiments were determined to be acceptable benchmark experiments. A similar experiment using uranyl nitrate was benchmarked as U233-SOL-THERM-014.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In the Lab with Nuclear Scientists: Critical and Subcritical Assemblies

This presentation talks on the Critical experiments performed on the NCERC machines. Plutonium ( 239 Pu and 240 Pu), Highly Enriched Uranium, Low-Temperature (-40°C). This is all based on a simple design useful for modeling and validation. The design is made to incorporate materials of interest such as Tantalum, hafnium, lithium & more.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimation of 240 Pu Mass in a Waste Tank Using Ultra-Sensitive Detection of Radioactive Xenon Isotopes from Spontaneous Fission

We report on a technique to detect and quantify the amount of 240 Pu in a large tank used to store nuclear waste from plutonium production at the Hanford nuclear site. While the contents of this waste tank are known from previous grab sample measurements, our technique could allow for determination of the amount of 240 Pu in the tank without costly sample retrieval and analysis of this highly radioactive material. This technique makes an assumption, which was confirmed, that 240 Pu dominates the spontaneous fissions occurring in the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of origin and intended use of plutonium metal using nuclear forensic techniques

Nuclear forensics techniques, including micro-XRF, gamma spectrometry, trace elemental analysis and isotopic/chronometric characterization were used to interrogate two, potentially related plutonium metal foils. These samples were submitted for analysis with only limited production information, and a comprehensive suite of forensic analyses were performed. Resulting analytical data was paired with available reactor model and historical information to provide insight into the materials’ properties, origins, and likely intended uses. Both were super-grade plutonium, containing less than 3% 240 Pu, and age-dating suggested that most recent chemical purification occurred in 1948 and 1955 for the respective metals. Additional consideration of reactor modelling feedback and trace elemental observables indicate plausible U.S. reactor origin associated with the Hanford site production efforts. In conclusion, based on this investigation, the most likely intended use for these plutonium foils was 239 Pu fission foil targets for physics experiments, such as cross-section measurements, etc.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Jupiter High-240 Experiment

The Jupiter High-240 experiment was performed in May of 2019 by researchers from Los Alamos National Laboratory (LANL) at the National Criticality Experiments Research Center (NCERC) in the Device Assembly Facility (DAF) located at the Nevada National Security Site (NNSS). This experiment has previously been mentioned briefly in prior publication related to a collaborative effort with the Japan Atomic Energy Agency (JAEA) to assess lead void coefficients of reactivity in uranium- and plutonium-fueled systems with lead. This series of experiments supports JAEA’s research into the development of an accelerator driven transmutation system for spent nuclear fuel. The Jupiter High-240 experiment built upon the previous Jupiter experiment by incorporating plutonium fuel plates with higher 240 Pu content. Efforts to formally benchmark the original Jupiter experiment have continued for inclusion in the benchmark handbook of the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Whereas there is much similarity between the two Jupiter experiments, there is a desire to also evaluate and benchmark this second experiment to further contribute towards the availability of lead-sensitive benchmarks. The components utilized in these two experiments have also been used to perform other subcritical and Rossi-α measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collated experience of the use of multi-group analysis (MGA) in non-destructive waste assay systems - 15257

The quantification of plutonium is an important aspect of non-destructive assay of Special Nuclear Material (SNM). The calculation of {sup 240}Pu{sub eff} can be done through prior knowledge of the composition of the waste but more often is done through the analysis of a measured plutonium gamma-ray spectrum performed using an isotopic analysis code. In this work, the {sup 240}Pu{sub eff} results from a variety of non-destructive waste assay systems in the UK are presented and compared using MGA v9.63C and v10. The body of the results include real measurement results of a variety of waste materials containing plutonium, the results of reanalysis of these initial waste measurements with changes to certain setup parameters and the results of reanalysis with a later version of MGA (v10). Additionally, measurements of test matrices with known source isotopics are measured and the results analysed and presented here. The use of the 'waste' flag parameter introduced to allow measurement of unusual spectra in v10 is also evaluated. When using MGA as part of the waste assay characterisation process in automatic or batch mode, results have proven to be very dependent on the quality of the spectra measured and on the setup parameters that the code is reliant upon. With a modern version of the code, the likelihood of under-reporting the total plutonium content of a 200 litre/55 gallon drum using PNCC and MGA isotopics in combination is low. Additionally, the latest 'hardened' code will also reduce the number of cases where MGA fails to run and the use of default isotopics results in an over-pessimistic evaluation of the total plutonium mass. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of Plutonium Ratios for CRM 137A Recertification

This report documents the analytical methodologies used by the Chemical and Isotopics Mass Spectrometry (CIMS) Group at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) for plutonium isotopic ratio characterizations on purified ~1 mg units prepared by Lawrence Livermore National Laboratory (LLNL) from a mother solution created from an existing 250 mg unit of certified reference material (CRM) 137. The analytical processes described are designed to maintain traceability of the final certified attributes and to eliminate sources of systematic bias for the measurements described. The measurands for certification are the plutonium isotope ratios: 238 Pu/ 239 Pu, 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu. The preparation and analytical process included the following activities: Preparation of reference materials to be used as calibrants to establish traceability to the SI unit of mass for the isotopic analyses and quality controls. For the plutonium isotopic analyses, CRM 128 (a CRM comprising equal atoms of 239 Pu and 242 Pu) was used as the primary calibrant; Each CRM 137A unit was reconstituted using dilute high-purity HNO3. From each, seven replicates were distributed for the isotopic characterizations by thermal ionization mass spectrometry (TIMS) using the total evaporation (TE) method for isotope ratio measurements and MC-ICP-MS using a dynamic peak hooping method for secondary isotope ratio measurements; Due to time delay in the analyses from the last purification of the original CRM 137 mother solution by LLNL, an aliquot of the three provided plutonium units was purified using Eichrom TEVA separation methods to remove americium in-growth and uranium impurities; Minimally corrected data were reported from each analysis using reporting templates provided by the New Brunswick Laboratory Program Office (NBL PO) for the specific methods used for isotopic measurements. In addition, a copy of the instrument exports, Excel templates for isotopic data corrections, and the uncertainty budgets completed with the GUM Workbench software package were submitted to NBL PO.

07 ISOTOPE AND RADIATION SOURCES↗

Hydrothermal Alteration of Glass from Underground Nuclear Tests: Formation and Transport of Pu-clay Colloids at the Nevada National Security Site

The testing of nuclear weapons at the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), has led to the deposition of substantial quantities of plutonium into the environment. Approximately 2.8 metric tons (3.1×10 4 TBq) of Pu were deposited in the NNSS subsurface as a result of underground nuclear testing. While 3 H is the most abundant anthropogenic radionuclide deposited in the NNSS subsurface (4.7×10 6 TBq), plutonium is the most abundant from a molar standpoint. The only radioactive elements in greater molar abundance are the naturally occurring K, Th, and U isotopes. 239 Pu and 240 Pu represent the majority of alpha-emitting Pu isotopes. The extreme temperatures associated with underground nuclear tests and the refractory nature of Pu results in most of the Pu (98%) being sequestered in melted rock, referred to as nuclear melt glass (Iaea, 1998). As a result, Pu release to groundwater is controlled, in large part, by the leaching (or dissolution) of nuclear melt glass over time. The factors affecting glass dissolution rates have been studied extensively. The dissolution of Pu-containing borosilicate nuclear waste glasses at 90ºC has been shown to lead to the formation of dioctahedral smectite colloids. Colloid-facilitated transport of Pu at the NNSS has been observed. Recent groundwater samples collected from a number of contaminated wells have yielded a wide range of Pu concentrations from 0.00022 to 2.0 Bq/L. While Pu concentrations tend to fall below the Maximum Contaminant Level (MCL) established by the Environmental Protection Agency (EPA) for drinking water (0.56 Bq/L), we do not yet understand what factors limit the Pu concentration or its transport behavior. To quantify the upper limit of Pu concentrations produced as a result of melt glass dissolution and determine the nature of colloids and Pu associations, we performed a 3 year nuclear melt glass dissolution experiment across a range of temperatures (25-200 °C) that represent hydrothermal conditions representative of the underground nuclear test cavities (when groundwater has re-saturated the nuclear melt glass and glass dissolution occurs). Colloid loads and Pu concentrations were monitored along with the mineralogy of both the colloids and the secondary mineral phases. The intent was to establish an upper limit for Pu concentrations at the NNSS, provide context regarding the Pu concentrations observed at the NNSS to date and the Pu concentrations that may be observed in the future. The results provide a conceptual model for the risks posed by Pu migration at the NNSS.

36 MATERIALS SCIENCE↗

Final Design for Thermal/Epithermal eXperiments using High 240 Pu Content Plutonium/Aluminum Zero Power Research Reactor Plates with Polyethylene Moderator (IER 520 Final Design CED-2 Report)

The US Department of Energy Nuclear Criticality Safety Program (NCSP) convened a multinational Thermal Epithermal eXperiments (TEX) meeting in July of 2011 to discuss the data and experimental needs of criticality safety practitioners. The number one and two priority integral experiment data needs were for 239 Pu and 240 Pu, with special emphasis on cross section performance in the intermediate energy range (from 0.625 eV to 100 keV). LLNL measured five critical configurations with LANL for the plutonium test bed (IER-184) and published the experiments as International Criticality Safety Benchmark Evaluation Project evaluation PUMET-MIXED-002. Modeling of the benchmark configurations using ENDF/B-VIII.0 nuclear data showed significant overprediction of reactivity for configurations that had a large percentage of fissions in the intermediate energy regime. This report documents a variation on the TEX plutonium test bed to provide a test of 240 Pu cross sections, with sensitivity of the configuration to 240 Pu radiative capture and fission cross sections a priority for the design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nondestructive and destructive assay for forensics characterization of weapons-grade plutonium produced in LEU irradiated in a thermal neutron spectrum

A post-irradiation examination (PIE) of an enriched uranium sample was performed to advance a nuclear forensics methodology, based on intra-elemental nuclide ratios. The PIE was carried out on a few milligrams of low enriched uranium dioxide (LEUO 2 ) sample, irradiated to a burnup of 1 GWd/MTU. The PIE of the LEUO 2 sample provided the concentration of selected plutonium and fission product nuclides ( 239 Pu, 240 Pu, 241 Pu, 91 Y, 95 Zr, 95 Nb, 103 Ru, 133 Cs, 134 Cs, 135 Cs, 137 Cs, 136 Ba, 138 Ba, 140 Ba, 140 La, 141 Ce, 144 Ce, 149 Sm, 150 Sm, 152 Sm, 153 Eu, and 154 Eu). The PIE supported validation of the MCNP (Monte Carlo N-Particle neutronics simulation code) predicted concentration of these nuclides in the irradiated LEUO 2 sample. This study showed that most of the MCNP predicted nuclide concentrations were within 15% and several within 10% compared to the PIE results. Furthermore, gamma and mass spectrometry of nuclides in irradiated LEUO 2 enabled the determination of uranium burnup and time since irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Multiplicity Counting Moments for Fissile Mass Estimation in Scatter-Based Neutron Detection Systems

Neutron multiplicity counting (NMC) techniques are widely used for nuclear materials accountability and international safeguards applications to quantitatively evaluate characteristic properties pertaining to fissile material. Mathematical models for NMC moments have been previously derived for systems that use capture-based detectors; however, these models are not applicable when scatter-based detectors are used because of “neutron cross talk.” Neutron cross talk occurs when a single neutron scatters and deposits energy above threshold into multiple detectors causing spurious increase in multiplicity counts; this, in turn, has caused fissile mass to be overestimated when not treated. In this paper, we propose new mathematical models derived from point kinetics to correct for neutron cross-talk effects up to any arbitrary order N, where N denotes the maximum number of counts a single neutron can cause. The new models were used to estimate the fissile mass of plutonium metal and oxide samples with effective 240 Pu mass ranging from 2.5 to 250 g. The adequacy of the models was confirmed using simulations of a conceptual scatter-based neutron multiplicity counter (e.g., organic scintillators) using MCNPX v2.7e with the PoliMi fission event generating extension. The fissile mass estimates with no correction for neutron cross-talk events yielded an average relative deviation from the true 240 Pu eff mass of 55.94% and 84.56% for metal and oxide samples, respectively. When neutron cross-talk events of order N = 2 are included in the model, the fissile mass estimates yielded an average relative deviation of 11.89% for metal and 13.21% for oxide samples. Accounting for neutron cross-talk events of order N = 3 resulted in fissile mass estimates with an average relative deviation of 9.58% and 10.51% for metal and oxide samples, respectively. These mass estimates were compared to a reference case (i.e., no neutron crosstalk effects) that yielded an average relative deviation of 6.81% and 4.77% for metal and oxide samples, respectively. In conclusion, the discrepancy between the estimates from the proposed model and the reference case is attributed to the assumed value of N, which sets a finite upper bound on the order of cross-talk events the model treats (i.e., the model for N = 3 assumes that a neutron will never cause more than three counts).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New simulation capability for gamma ray mirror experiments

This report provides a description of the simulation toolkit developed at Lawrence Livermore National Laboratory to support the design of nuclear safeguards experiments using grazing incidence multilayer mirrors in the energy band of uranium (U) and plutonium (Pu) emission lines. This effort was motivated by the data analysis of a scoping experiment at the Irradiated Fuels Examination Facility (IFEL) at Oak Ridge National Laboratory in FY13 and of a benchmark experiment at the Idaho National Laboratory (INL) in FY14 that highlighted the need for predictive tools built around a ray-tracing capability. This report presents the simulation toolkit and relevant results such as the simulated spectra for TMI, MOX, and ATM106 fuel rods based on spent fuel models provided by Los Alamos National Laboratory and for a virgin high 240 Pu-content fuel plate, as well as models of the IFEL and INL experiments implemented in the ray tracing tool. The beam position and height were validated against the INL ~60 keV americium data. Examples of alternate configurations of the optics or experimental set-up illustrate the future use of the simulation suite to guide the next IFEL experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using anisotropies in prompt fission neutron coincidences to assess the neutron multiplication of highly multiplying subcritical plutonium assemblies

There is a significant and well-known anisotropy between the prompt neutrons emitted from a single fission event; these neutrons are most likely to be observed at angles near 0° or 180° relative to each other. However, the propagation of this anisotropy through different generations of a fission chain re-action has not been previously studied. We have measured this anisotropy in neutron–neutron coincidences from a subcritical highly-multiplying assembly of plutonium metal. The assembly was a 4.5 kg α-phase plutonium metal sphere composed of 94% 239 Pu and 6% 240 Pu by mass. Data were collected using two EJ-309 liquid scintillators and two EJ-299 plastic scintillators. The angular distribution of neutron–neutron coincidences was measured at 90° and 180° and found to be largely isotropic. Simulations were performed using MCNPX-PoliMi of similar plutonium metal spheres of varying sizes and a correlation between the neutron multiplication of the assembly and the anisotropy of neutron–neutron coincidences was observed. In principle, this correlation could be used to assess the neutron multi-plication of an unknown assembly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A multi-collector ICP-MS method for quantification of plutonium, uranium, and americium in hair and nails of occupationally or medically exposed individuals

The 239 Pu, 238 U, and 241 Am concentrations and 239 Pu/ 240 Pu, 235 U/ 238 U, and 236 U/ 238 U atom ratios were measured in the hair and nail samples from individuals who donated their bodies to the United States Transuranium and Uranium Registries. Further, the concentration of 239 Pu ranged from 0.22–15.8 ng/kg. The 240 Pu/ 239 Pu isotopic ratios ranged from 0.026 to 0.127 which is consistent with weapons-grade plutonium. Concentration of uranium fell between 1.84 µg/kg and 29.5 µg/kg and 235 U/ 238 U ratios ranged from 4.8×10 -3 to 7.6×10 -3 . Elevated 236 U/ 238 U atom ratios were measured in two cases and ranged from 5.0×10 -6 – 2.4×10 -5 indicating exposure to spent or reprocessed uranium material. The concentration of 241 Am was measured in four hair samples and ranged from 0.02–0.21 ng/kg.

61 RADIATION PROTECTION AND DOSIMETRY↗