Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Improvement of photovoltaic pumping systems based on standard frequency converters by means of programmable logic controllers

Photovoltaic pumping systems (PVPS) based on standard frequency converters (SFCs) are currently experiencing a growing interest in pumping programmes implemented in remote areas because of their high performance in terms of component reliability, low cost, high power range and good availability of components virtually anywhere in the world. However, in practical applications there have appeared a number of problems related to the adaptation of the SFCs to the requirements of the photovoltaic pumping systems (PVPS). Another disadvantage of dedicated PVPS is the difficulty in implementing maximum power point tracking (MPPT). This paper shows that these problems can be solved through the addition of a basic industrial programmable logic controller (PLC) to the system. This PLC does not increase the cost and complexity of the system, but improves the adaptation of the SFC to the photovoltaic pumping system, and increases the overall performance of the system. (author)

14 SOLAR ENERGY↗

Inhibition of hydrogen sulfide on the proliferation of vascular smooth muscle cells involved in the modulation of calcium sensing receptor in high homocysteine

Hyperhomocysteinemia induces the proliferation of vascular smooth muscle cells (VSMCs). Hydrogen sulfide (H{sub 2}S) inhibits the phenotype switch of VSMCs and calcium-sensing receptor (CaSR) regulated the production of endogenous H{sub 2}S. However, whether CaSR inhibits the proliferation of VSMCs by regulating the endogenous cystathionine-gamma-lyase (CSE, a major enzyme that produces H{sub 2}S) pathway in high homocysteine (HHcy) has not been previously investigated. The intracellular calcium concentration, the concentration of H{sub 2}S, the cell viability, the proliferation and the expression of proteins of cultured VSMCs from rat thoracic aortas were measured, respectively. The results showed that the [Ca{sup 2+}]{sub i} and the expression of p-CaMK and CSE increased upon treatment with CaSR agonist. In HHcy, the H{sub 2}S concentration decrease, the proliferation and migration rate increased, the expression of Cyclin D1, PCNA, Osteopontin and p-Erk1/2 increased while the α-SM actin, P21{sup Cip/WAK−1} and Calponin decreased. The CaSR agonist or exogenous H{sub 2}S significantly reversed the changes of VSMCs caused by HHcy. In conclusion, our results demonstrated that CaSR regulate the endogenous CSE/H{sub 2}S is related to the PLC-IP{sub 3} receptor and CaM signal pathways which inhibit the proliferation of VSMCs, and the latter is involved in the Erk1/2 dependent signal pathway in high homocysteine. - Highlights: • CaSR activation increased the production of endogenous H{sub 2}S in high homocysteine VSMCs. • CaSR modulated the CSE/H{sub 2}S are related to the PLC-IP{sub 3}R and Ca{sup 2+}-CaM signal pathways. • Inhibition of H{sub 2}S on the proliferation of VSMCs is involved in the Erk1/2 pathway. • Explore the potential roles of CaSR in regulating VSMCs proliferation in high homocysteine.

60 APPLIED LIFE SCIENCES↗

Simulating the mechanisms of serrated flow in interstitial alloys with atomic resolution over diffusive timescales

Abstract The Portevin-Le Chatelier (PLC) effect is a phenomenon by which plastic slip in metallic materials becomes unstable, resulting in jerky flow and the onset of inhomogeneous deformation. The PLC effect is thought to be fundamentally caused by the dynamic interplay between dislocations and solute atoms. However, this interplay is almost always inaccessible experimentally due to the extremely fine length and time scales over which it occurs. In this paper, simulations of jerky flow in W-O interstitial solid solutions reveal three dynamic regimes emerging from the simulated strain rate-temperature space: one resembling standard solid solution strengthening, another one mimicking solute cloud formation, and a third one where dislocation/solute coevolution leads to jerky flow as a precursor of dynamic strain aging. The simulations are carried out in a stochastic framework that naturally captures rare events in a rigorous manner, providing atomistic resolution over diffusive time scales using no adjustable parameters.

36 MATERIALS SCIENCE↗

The enhanced ASDEX Upgrade pellet centrifuge launcher

Pellets played an important role in the program of ASDEX Upgrade serving both for investigations on efficient particle fuelling and high density scenarios but also for pioneering work on Edge Localised Mode (ELM) pacing and mitigation. Initially designed for launching fuelling pellets from the magnetic low field side, the system was converted already some time ago to inject pellets from the magnetic high field side as much higher fuelling efficiency was found using this configuration. In operation for more than 20 years, the pellet launching system had to undergo a major revision and upgrading, in particular of its control system. Furthermore, the control system installed adjacent to the launcher had to be transferred to a more distant location enforcing a complete galvanic separation from torus potential and a fully remote control solution. Changing from a hybrid system consisting of PLC S5/S7 and some hard wired relay control to a state of the art PLC system allowed the introduction of several new operational options enabling more flexibility in the pellet experiments. This article describes the new system architecture of control hardware and software, the operating procedure, and the extended operational window. First successful applications for ELM pacing and triggering studies are presented as well as utilization for the development of high density scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrumentation and Control Selection for the 12 GeV Hall-B Magnets at Jefferson Lab

Here, as part of the Jefferson Lab 12 GeV accelerator upgrade, the Experimental Physics Hall B detector system requires two superconducting magnets – a Torus and a Solenoid. The specifications required maximum space for the detectors which led to the choice of conduction cooling for each magnet. The Torus consists of 6 trapezoidal 'race-track'-type coils connected in series with an operating current of 3770 A. The Solenoid is an actively shielded 5 Tesla magnet consisting of 5 coils connected in series operating at 2416 A. Within the hall the two magnets are located in close proximity to each other and are surrounded by particle detectors. We describe the philosophy behind the instrumentation selection and control design that accounts for this proximity and other challenging working conditions. We describe the choice of sensor technologies, as well as the control and data acquisition methods. The magnet power and cryogenic control sub-systems are implemented using Allen Bradley Control Logix 1756-L72 Programmable Logic Controllers. Sensor instrumentation read-backs are routed into the PLC via National Instruments cRIO hardware (Field Programmable Gate Arrays or FPGA/RT application) using Jefferson Lab designed FPGA-based multi-sensor-excitation-chassis. Configuration, monitoring, and alarm handlers for the magnet systems are provided via an Experimental Physics Instrumentation & Control System interface (EPICS). Failure Modes and Effects Analysis (FMEA) and the requirement to monitor critical parameters during operation guided the selection of instrumentation and associated hardware. The design of the quench protection and voltage tap sub-systems was driven by the anticipated level of voltages developed during a magnet quench. The primary hard-wired quench detection and protection sub-system together with the secondary PLC-based protection sub-system is also discussed. The successful commissioning and subsequent performance of these magnets demonstrates the robustness of the design and implementation approach that was adopted by the Jefferson Lab team and serves as an excellent 'How To' guide for future projects of this size and complexity.

12 GeV↗

Seawater exposure causes hydraulic damage in dying Sitka-spruce trees

Sea-level rise is one of the most critical challenges facing coastal ecosystems under climate change. Observations of elevated tree mortality in global coastal forests are increasing, but the mechanism of salinity-stress induced tree mortality is currently unknown. We monitored progressive mortality and associated gas exchange and hydraulic shifts in Sitka-spruce (Picea sitchensis) trees located within a salinity gradient under an ecosystem-scale change of seawater exposure in Washington State, USA. Percentage of live foliated crown (PLFC) decreased and tree mortality increased with increasing soil salinity during the study period. A strong reduction in gas exchange and xylem hydraulic conductivity (Ks) occurred during tree death, with an increase of the percentage loss of xylem conductivity (PLC) and turgor loss point (ptlp). Hydraulic and osmotic shifts reflected that hydraulic function declined from seawater exposure and dying trees were unable to support osmotic adjustment. Constrained gas exchange was strongly related to hydraulic damage at both stem and leaf levels. Significant correlations between foliar sodium (Na+) concentration and gas exchange and key hydraulic parameters (Ks, PLC and ptlp ) suggest that cellular injury related to the toxic effects of ion accumulation impacted the physiology of these dying trees. This study provides evidence of toxic effects on cellular function that become manifest in all aspects of plant functioning, leading to unfavourable osmotic and hydraulic conditions.

Zhang, Hongxia↗

Tapping into the physiological responses to mistletoe infection during heat and drought stress

Mistletoes are important co-contributors to tree mortality globally, particularly during droughts. In Australia, mistletoe distributions are expanding in temperate woodlands, while their hosts have experienced unprecedented heat and drought stress in recent years. We investigated whether the excessive water use of mistletoes increased the probability of xylem emboli in a mature woodland during the recent record drought that was compounded by multiple heatwaves. Additionally, we continuously recorded transpiration ($T_{SLA}$) of infected and uninfected branches from two eucalypt species over two summers, monitored stem and leaf water potentials ($\Psi $) and used hydraulic vulnerability curves to estimate percent loss in conductivity (PLC) for each species. Variations in weather (vapor pressure deficit, photosynthetically active radiation, soil water content), host species and % mistletoe foliage explained 78% of hourly $T_{SLA}$. While mistletoe acted as an uncontrollable sink for water in the host even during typical summer days, daily $T_{SLA}$ increased up to 4-fold in infected branches on hot days, highlighting the previously overlooked importance of temperature stress in amplifying water loss in mistletoes. The increased water use of mistletoes resulted in significantly decreased host $\Psi _{\rm{leaf}}$ and $\Psi _{\rm{trunk}}$. It further translated to an estimated increase of up to 11% PLC for infected hosts, confirming greater hydraulic dysfunction of infected trees that place them at higher risk of hydraulic failure. However, uninfected branches of Eucalyptus fibrosa F.Muell. had much tighter controls on water loss than uninfected branches of Eucalyptus moluccana Roxb., which shifted the risk of hydraulic failure towards an increased risk of carbon starvation for E. fibrosa. The contrasting mechanistic responses to heat and drought stress between both co-occurring species demonstrates the complexity of host–parasite interactions and highlights the challenge in predicting species-specific responses to biotic agents in a warmer and drier climate.

59 BASIC BIOLOGICAL SCIENCES↗

Color transparency and the proton form factor: Evidence for the Feynman mechanism

A recent experiment by D. Bhetuwal et al. [Phys. Rev. Lett. 126, 082301 (2021)] used the (e,e'p) reaction on 12 C to search for the effects of color transparency (the absence of final-state interactions). Color transparency was said to be ruled out. Observing the effects of color transparency depends on the ability of a putative point-like-configuration (PLC), formed in a high-momentum transfer coherent reaction, to escape the nucleus without expanding its size. Here, we study the expansion aspect of color transparency using superconformal baryon-meson symmetry and light-front holographic QCD. A new formalism is obtained and used to analyze the recent experiment. The resulting conclusion is that effects of expansion would not be sufficiently significant in causing final-state interactions to occur. Therefore, we conclude that a PLC was not formed. In conclusion, this means that the Feynman mechanism involving virtual photon absorption on a single high-momentum quark is responsible for the high-momentum electromagnetic form factor of the proton.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Superconducting Magnet Power Supply and Hard-Wired Quench Protection at Jefferson Lab for 12 GeV Upgrade

The superconducting magnet system in Hall B being designed and built as part of the Jefferson Lab 12 GeV upgrade requires powering two conduction cooled superconducting magnets - a torus and a solenoid. The torus magnet is designed to operate at 3770 A and solenoid at 2416 A. Failure Modes and Effects Analysis (FMEA) determined that voltage level thresholds and dump switch operation for magnet protection should be tested and analyzed before incorporation into the system. The designs of the quench protection and voltage tap sub-systems were driven by the requirement to use a primary hard-wired quench detection sub-system together with a secondary PLC-based protection. Parallel path voltage taps feed both the primary and secondary quench protection sub-systems. The PLC based secondary protection is deployed as a backup for the hard-wired quench detection sub-system and also acts directly on the dump switch. Here, we describe a series of tests and modifications carried out on the magnet power supply and quench protection system to ensure that the superconducting magnet is protected for all fault scenarios.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Effect of calcite filler on carbonation behavior in a synthesized C‐S‐H binder

Widespread implementation of portland limestone cements (PLC) in industry has raised new questions about their carbonation resistance due to higher initial limestone content than ordinary portland cement. While carbonation of portland cement and each of its hydrate phases has been studied at a fundamental level, the integral role of how limestone fillers interact chemically or physically during carbonation necessitates further study. In this study, a C-S-H binder comprised of a highly reactive zeolite pozzolan and lime was used to evaluate the effect of varying calcite additions on carbonation behavior at a microstructural level. Fundamental insight into hydration kinetics and carbonation mechanisms of hydraulic binders was obtained via analysis of the C-S-H and calcite microstructure. X-ray microcomputed tomography (X-ray CT) was used to quantify microstructural changes, and the results showed a decrease in shrinkage for increased calcite dosages, with a ∼50% reduction observed for a 45% wt. calcite replacement level. Crystallographic and thermal analyses measured compositional changes in the binder and confirmed that shrinkage was related to the decalcification of C-S-H. Furthermore, the addition of calcite to the C-S-H binder effectively reduced the liquid-to-solid ratio, porosity, and amount of C-S-H present in these binders. Ultimately, these results help elucidate how the carbonation risks of PLC can be mitigated by proportioning the mixture water only to the reactive component of the binder.

C-S-H↗

OLED Luminaire with Panel Integrated Drivers and Advanced Controls

For this DOE award, Acuity Brands Lighting developed a novel OLED luminaire system featuring panel-integrated drivers at each individual OLED panel. The luminaire has a base station that receives user commands and performs AC/DC conversion. A power line communication (PLC) protocol is used to provide both power and digital control to each panel. A 66-panel CanvisTM luminaire using state-of-art OLED panels based on this system was successfully constructed. This is a first demonstration of such a luminaire architecture. It is also the first known implementation of this number of independently addressable nodes with a PLC protocol. This luminaire system architecture has added benefits in the flexibility of using multiple panel vendors for a given product, forward compatibility with future panels, and reduced luminaire wiring complexity and assembly time.

47 OTHER INSTRUMENTATION↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automation of debris removal and resurfacing of insulators in terawatt pulsed power systems using state of the art laser technology

The increasing complexity and scale of pulsed power systems necessitate effective maintenance strategies to ensure optimal performance and safety. This report investigates the automation of debris removal and resurfacing of insulators in terawatt pulsed power systems using advanced laser cleaning technologies. The motivation for this research stems from the limitations of current manual cleaning methods, which are labor-intensive and pose health risks due to hazardous materials. The study addresses the problem of surface flashover, a significant issue affecting insulator performance, by evaluating two innovative cleaning techniques: Pulsed Laser Cleaning (PLC) and Flash Lamp Annealing (FLA). Experimental results demonstrate that PLC effectively restores the dielectric strength of Rexolite insulators, while FLA shows limited success. The findings highlight the potential for automated cleaning solutions to enhance safety and efficiency in insulator maintenance, paving the way for future advancements in pulsed power technology.

42 ENGINEERING↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardwired Control Changes For NSTX DC Power Feeds

The National Spherical Torus Experiment (NSTX) has been designed and installed in the existing facilities at Princeton Plasma Physics Laboratory (PPPL). Most of the hardware, plant facilities, auxiliary sub-systems, and power systems originally used for the Tokamak Fusion Test Reactor (TFTR) have been used with suitable modifications to reflect NSTX needs. The original TFTR Hardwired Control System (HCS) with electromechanical relays was used for NSTX DC Power loop control and protection during NSTX operations. As part of the NSTX Upgrade, the HCS is being changed to a PLC-based system with the same control logic. This paper gives a description of the changeover to the new PLC-based system __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails, and a demonstrator setup installation within a NPP verify the overall performance of the proposed system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flexible Packaging and Real Time Assay Techniques to Divert Low Activity Waste LLW from the UK LLWR - 18011

Historically, all Low Level Waste (LLW) produced in the UK was sent to the Low Level Waste Repository (LLWR) near Drigg in Cumbria in mild steel IP2 containers. However, this single national asset is filling up very quickly and the UK national LLW policy is to divert waste to alternative sites wherever possible. This paper will describe how through a collaboration between Magnox Ltd, NUVIA Limited, Pactec EPS and Augean Plc has allowed for low activity LLW (<200 MBq/Tonne) to be packaged into IP1 flexible bags, assayed within the flexible packages and then consigned to a suitably designed and licensed landfill site. The Magnox site at Harwell in Oxfordshire is in the process of total decommissioning. A project was initiated to explore the viability of utilising the PACTEC LIFTPAC{sup R} IP1 flexible packages which can contain 1 m{sup 3} of waste and assaying the waste using the NUVIA Limited transportable High Resolution Assay Monitor (HiRAM) before sending the waste for disposal at the Augean Plc East Northants Resource Management Facility (ENRMF) in Cambridgeshire. The project led to a fundamental change in the culture of LLW disposal and the paper will explore the commonly held misconception that flexible packaging can only be used for the transportation and disposal of Very Low Level Waste (VLLW). It will also explore how the NUVIA Limited HiRAM system can assay large quantities of these bags in a short time period to a high level of accuracy such that they were able to consign the waste for disposal to ENRMF. This technique and disposal route is open and available to many other waste producers both within the UK and beyond and has proven cost savings to the waste producer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗