Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PIVOT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of ARGOS (Active Response Gravity Offload System) Offloading Assessments and Methodology for Lunar EVA Simulations

The Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) is an analog environment that can offload pressurized suited subjects for various reduced gravity simulations. The suit is suspended from a robotic overhead crane by a cable connected to the suit via a gimbal with an adjustable pivot point (i.e. offload attachment). There has been increased interest in providing planetary pressurized suited training at ARGOS in preparation for lunar missions. Determination of the appropriate gimbal pivot point location for a given subject is vital for a high-fidelity functional lunar simulation. Interactions between the pivot point location and human-spacesuit center of gravity (CG) can result in righting moments that may lead to artificially stable or unrealistically challenging configurations. Changing the pivot point location is time consuming and repeated adjustment can result in loss of valuable pressurized suited time. This paper aims to share knowledge obtained from the offloading characterization efforts during pressurized suited testing at ARGOS and document the ongoing process to define an appropriate pivot point location through iterative quantitative and qualitative assessments. Human-spacesuit CG locations for the ARGOS lunar simulation were estimated using a 3D body scan and density model combined with spacesuit hardware CAD and specifications. Early pilot testing of the gimbal revealed that setting the pivot point coincident with the modeled CG location was not always possible due to the current gimbal design, and small pivot point shifts had noticeable effects on subject stability. Fourteen subjects performed a series of CG-related tasks in the Exploration Extravehicular Mobility Unit (xEMU) to assess simulation characteristics. Through iterative testing, this task list evolved to streamline the process needed to efficiently identify a suitable pivot point for a given subject. The developed methodology will be critical for pivot point selection during astronaut training in the ARGOS environment.

Sarah L. Jarvis↗

The Efficiency of Small Bearings in Instruments of the Type Used in Aircraft

This report deals with the construction and properties of bearings and pivots for use in instruments. The static and running friction for both thrust and radial loads was determined for a number of conical pivots and cylindrical and ball bearings. The static rocking friction was also measured for several conical and ball bearings under a heavy load, especially to determine their suitability for use in N. P. L. (National Physical Laboratory) type wind tunnel balance. In constructing conical pivots and sockets it was found that the pivots should be hardened and highly polished, preferably with a revolving lap, and that the sockets should be made by punching with a hardened and polished punch. It was found that for a light load the conical pivots give less friction than any other type, and their wearing qualities when hardened are excellent. Very small ball bearings are unsatisfactory because the proportional accuracy of the balls and races is not high enough to insure smooth running. For rocking pivots under heavy loads it was found that a ball-and-socket bearing, consisting of a hemispherical socket and a sphere of smaller diameter concentric with it, with a row of small balls resting between the two, was superior to a pivot resting in a socket. It was found that vibration such as occurs in an airplane will greatly reduce the static friction of a pivot or bearing, in some cases to as little as one-twentieth of its static value.

Norton, F H↗

Development of ARGOS Offloading Assessments and Methodology for Lunar EVA Simulations

The Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) is an analog environment that can offload pressurized suited subjects at various gravity levels. The suit is suspended from a robotic overhead crane by a cable connected to the suit via a gimbal with an adjustable pivot point. There has been increased interest in providing lunar pressurized suited training at ARGOS in preparation for lunar missions. Determination of the appropriate gimbal pivot point location for a given subject is vital for a high-fidelity and functional lunar simulation. Interactions between the pivot point location and center of gravity (CG) can result in righting moments that may lead to artificially stable or unrealistically challenging configurations. Changing the pivot point location is time consuming and repeated adjustment can result in significant loss of valuable pressurized suited time. This paper aims to share the knowledge obtained from the offloading characterization efforts during pressurized suited testing at ARGOS and document the ongoing process to define an appropriate pivot point location through iterative quantitative and qualitative assessments. The human-spacesuit CG locations for the ARGOS lunar simulation were estimated using a 3D body scan and density model combined with spacesuit hardware CAD and specifications. Early pilot testing of the gimbal revealed that setting the pivot point coincident with the modeled CG location was not always possible due to the current gimbal design, and small shifts forward and aft had noticeable effects on subject stability. Fifteen subjects performed a series of CG-related tasks in the xEMU spacesuit to assess simulation acceptability. Through iterative testing, this task list evolved to streamline the process needed to efficiently identify a suitable pivot point for a given subject. The developed methodology will be critical to determine pivot point selection for astronaut training in the xEMU ARGOS environment.

Sarah L. Jarvis↗

Supersonic aeroelastic instability results for a NASP-like wing model

An experimental study and an analytical study have been conducted to examine static divergence for hypersonic-vehicle wing models at supersonic conditions. A supersonic test in the Langley Unitary Plan Wind Tunnel facility was conducted for two wind-tunnel models. These models were nearly identical with the exception of airfoil shape. One model had a four-percent maximum thickness airfoil and the other model had an eight-percent maximum thickness airfoil. The wing models had low-aspect ratios and highly swept leading edges. The all-movable wing models were supported by a single-pivot mechanism along the wing root. For both of the wind-tunnel models, configuration changes could be made in the wing-pivot location along the wing root and in the wing-pivot pitch stiffness. Three divergence conditions were measured for the four-percent thick airfoil model in the Mach number range of 2.6 to 3.6 and one divergence condition was measured for the eight-percent thick airfoil model at a Mach number of 2.9. Analytical divergence calculations were made for comparison with experimental results and to evaluate the parametric effects of wing-pivot stiffness, wing-pivot location, and airfoil thickness variations. These analyses showed that decreasing airfoil thickness, moving the wing-pivot location upstream, or increasing the pitch-pivot stiffness have the beneficial effect of increasing the divergence dynamic pressures. The calculations predicted the trend of experimental divergence dynamic pressure with Mach number accurately; however, the calculations were approximately 25 percent conservative with respect to dynamic pressure.

Cole, Stanley R.↗

Joint for a variable geometry truss and method of constructing same

A joint and a method of constructing a joint for a variable geometry truss having a variable number of planes of variable length battens connected together in a triangular configuration, each plane being connected by six fixed length longerons in a Stewart platform configuration, are presented. The variable length battens allow the orientation of one end plane of the variable geometry truss to be changed to the other end plane in a controlled manner by selectively adjusting the lengths of the variable length battens. A main pivot joint pivotally connects two battens about a pivotal axis. A universal joint is pivotally connected to the main joint such that the pivotal axis of the universal joint is coextensive with the pivotal axis at the main joint. Two longerons are pivotally connected to the universal joint. Each longeron is thereby provided with three intersecting axes of rotation. Each longeron may include a revolute joint, allowing rotation about the longitudinal axis of the longeron.

Horner, Garnett C.↗

Tool for Bending a Metal Tube Precisely in a Confined Space

A relatively simple, manually operated tool enables precise bending (typically, within 1/2 of the specified bend angle) of a metal tube located in a confined space, with a minimum of flattening of the tube and without significant gouging of the tube surface. The tool is designed for use in a situation in which the tube cannot be removed from the confined space for placement in a conventional benchmounted tube bender. The tool is also designed for use in a situation in which previously available hand-held tube benders do not afford the required precision, do not support the tube wall sufficiently to prevent flattening or gouging, and/or do not fit within the confined space. The tool is designed and fabricated for the specific outer diameter and bend radius of the tube to be bent. The tool (see figure) includes a clamping/radius block and a top clamping block that contain mating straight channels of semicircular cross section that fit snugly around the tube. The mating portions of the clamping/radius block and the top clamping block are clamped around a length of the tube that is adjacent to the bend and that is intended to remain straight. The clamping/radius block is so named because beyond the straight clamping section, its semicircular channel extends to a non-clamping section that is curved at the specified bend radius. A pivot hole is located in the clamping/radius block at the center of the bend circle. The tool includes a bending block that, like the other blocks, contains a straight semicircular channel that fits around the outside of the tube. The bending block contains a pivot hole to be aligned with the pivot hole in the clamping/radius block. Once the tube has been clamped between the clamping/ radius and top clamping blocks, the bending block is placed around the tube, the pivot holes are aligned, and a pivot pin is inserted through the pivot holes.

Davis, Gary T.↗

In-Depth Analysis of Subject Functional Performance and Subjective Feedback Data for Evaluating Argos Simulation Quality

Mechanical offloading systems such as the Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) are used to simulate various partial gravity environments. ARGOS offloads pressurized suited subjects through a gimbaling pivot point system attached to a volumetric Portable Life Support System (PLSS). The pivot point can be configured to multiple locations with respect to the human-suit system center of gravity (CG). Previous work has tested and documented the interaction between different pivot point locations and measured CG. Observations indicated that small changes in pivot point location substantially affect the stability and functional performance (simulation quality) of a subject. This led to the development of a standardized gimbal assessment protocol to assess the functional performance of a pressurized suited subject as a function of the pivot point location, using the data obtained from a variety of planetary suit mobility tasks. As a result, an expansive repository of CG-related task metrics was generated from numerous ARGOS spacesuit test events, for different gimbal configurations and different test subjects. Based on the evaluation metrics and observed trends, several pivot point locations were iteratively identified to determine an “appropriate/optimal” configuration. This study thus describes the in-depth analysis of the CG evaluation metrics to better quantify trends and determine if specific factors are strongly associated with appropriate/optimal configurations. Quantitative and qualitative variables relating to subject task performance, subjective feedback, and anthropometry will be evaluated via probabilistic methods. The results from this study are expected to improve our understanding of optimal ARGOS gimbal settings, which will better inform the gimbal configuration identification process and improve simulation quality for extravehicular activity (EVA) training.

Joseph Yao↗

Electrical servo actuator bracket

An electrical servo actuator is mounted on a support arm which is allowed to pivot on a bolt through a fixed mounting bracket. The actuator is pivotally connected to the end of the support arm by a bolt which has an extension allowed to pass through a slot in the fixed mounting bracket. An actuator rod extends from the servo actuator to a crank arm which turns a control shaft. A short linear thrust of the rod pivots the crank arm through about 90 for full-on control with the rod contracted into the servo actuator, and full-off control when the rod is extended from the actuator. A spring moves the servo actuator and actuator rod toward the control crank arm once the actuator rod is fully extended in the full-off position. This assures the turning of the control shaft to a full-off position. A stop bolt and slot are provided to limit pivot motion. Once fully extended, the spring pivots the motion.

Sawyer, R. V.↗

Cervix-to-rectum measuring device in a radiation applicator for use in the treatment of cervical cancer

A cervix-to-rectum measuring device to be used in the treatment of cervical cancer is described. It includes a handle and a probe pivotably connected to the handle for insertion in the rectum. The measuring device further includes means for coupling the handle to an intrauterine radiation applicator when the latter is positioned in the uterine cervix and the probe is inserted in the rectum to pivot the handle about the probe. A gear is provided which is adapted to pivot with the probe. A pinion pivotably connected to the handle meshes with the gear. A pointer fixed to the pinion is displaced in response to the pivoting of the handle about the probe, and this displacement can be read from a scale on the handle, providing an indication of the cervix-to-rectum distance.

Fischell, D. R.↗

Mars Science Laboratory Rover Mobility Bushing Development

NASA s Mars Science Laboratory (MSL) Project will send a six-wheeled rover to Mars in 2009. The rover will carry a scientific payload designed to search for organic molecules on the Martian surface during its primary mission. This paper describes the development and testing of a bonded film lubricated bushing system to be used in the mobility system of the rover. The MSL Rover Mobility System contains several pivots that are tightly constrained with respect to mass and volume. These pivots are also exposed to relatively low temperatures (-135 C) during operation. The combination of these constraints led the mobility team to consider the use of solid film lubricated metallic bushings and dry running polymeric bushings in several flight pivot applications. A test program was developed to mitigate the risk associated with using these materials in critical pivots on the MSL vehicle. The program was designed to characterize bushing friction and wear performance over the expected operational temperature range (-135 C to +70 C). Seven different bushing material / lubricant combinations were evaluated to aid in the selection of the final flight pivot bushing material / lubricant combination.

Riggs, Benjamin↗

Shoulder Injuries in US Astronauts Related to EVA Suit Design

Introduction: For every one hour spent performing extravehicular activity (EVA) in space, astronauts in the US space program spend approximately six to ten hours training in the EVA spacesuit at NASA-Johnson Space Center's Neutral Buoyancy Lab (NBL). In 1997, NASA introduced the planar hard upper torso (HUT) EVA spacesuit which subsequently replaced the existing pivoted HUT. An extra joint in the pivoted shoulder allows increased mobility but also increased complexity. Over the next decade a number of astronauts developed shoulder problems requiring surgical intervention, many of whom performed EVA training in the NBL. This study investigated whether changing HUT designs led to shoulder injuries requiring surgical repair. Methods: US astronaut EVA training data and spacesuit design employed were analyzed from the NBL data. Shoulder surgery data was acquired from the medical record database, and causal mechanisms were obtained from personal interviews Analysis of the individual HUT designs was performed as it related to normal shoulder biomechanics. Results: To date, 23 US astronauts have required 25 shoulder surgeries. Approximately 48% (11/23) directly attributed their injury to training in the planar HUT, whereas none attributed their injury to training in the pivoted HUT. The planar HUT design limits shoulder abduction to 90 degrees compared to approximately 120 degrees in the pivoted HUT. The planar HUT also forces the shoulder into a forward flexed position requiring active retraction and extension to increase abduction beyond 90 degrees. Discussion: Multiple factors are associated with mechanisms leading to shoulder injury requiring surgical repair. Limitations to normal shoulder mechanics, suit fit, donning/doffing, body position, pre-existing injury, tool weight and configuration, age, in-suit activity, and HUT design have all been identified as potential sources of injury. Conclusion: Crewmembers with pre-existing or current shoulder injuries or certain anthropometric body types should conduct NBL EVA training in the pivoted HUT.

Scheuring, R. A.↗

Variable Geometry Aircraft Wing Supported by Struts And/Or Trusses

The present invention provides an aircraft having variable airframe geometry for accommodating efficient flight. The aircraft includes an elongated fuselage, an oblique wing pivotally connected with said fuselage, a wing pivoting mechanism connected with said oblique wing and said fuselage, and a brace operably connected between said oblique wing and said fuselage. The present invention also provides an aircraft having an elongated fuselage, an oblique wing pivotally connected with said fuselage, a wing pivoting mechanism connected with said oblique wing and said fuselage, a propulsion system pivotally connected with said oblique wing, and a brace operably connected between said propulsion system and said fuselage.

Melton, John E.↗

Baseline Monitoring for Astrometry in Interferometry

One of the science goals of NASA's Navigator program is ground-based narrow-angle astrometry for extra-solar planet detection, which could be done as part of the proposed Outrigger Telescopes Project. The narrow-angle measurement process, which would use the outrigger telescopes, starts with the determination of the conventional interferometer astrometric baseline, determined from wide-angle astrometry of Hipparcos stars. A baseline monitor system would be employed at each outrigger telescope. This system monitors the pivot point of each telescope - the end point of the astrometric baseline - to measure telescope imperfections that would cause the baseline to vary with telescope rotation. The baseline monitor includes azimuth and elevation cameras that monitor runout along the azimuth and elevation axes of the telescopes. In conjunction with the baseline monitor system, a pivot monitor camera in the dual-star module is used to register the laser metrology corner-cube reflector to the telescope pivot, tying the narrow-angle baseline, which applies to the narrow-angle astrometric measurement, to the wide-angle baseline. In this paper we present the proposed designs for the baseline monitor and pivot-point camera.

pivot point↗

Tool for use in lifting pin supported objects

A tool for use in lifting a pin-supported, electronic package mounted in juxtaposition with the surface of an electronic circuit board is described. The tool is configured to be received beneath a pin-supported package and is characterized by a manually operable linkage, including an elongated, rigid link is supported for axial reciprocation and a pivotal link pinned to the body and supported for oscillation induced in response to axial motion imparted to the rigid link. A lifting plate is pivotally coupled to the distal end of the pivotal link so that oscillatory motion imparted to the pivotal link serves to move the plate vertically for elevating the plate into lifting engagement with the electronic package positioned thereabove.

Marzek, R. A.↗

System for imposing directional stability on a rocket-propelled vehicle

An improved system for use in imposing directional stability on a rocket-propelled vehicle is described. The system includes a pivotally supported engine-mounting platform, a gimbal ring mounted on the platform and adapted to pivotally support a rocket engine and an hydraulic actuator connected to the platform for imparting selected pivotal motion. An accelerometer and a signal comparator circuit for providing error intelligence indicative of aberration in vehicle acceleration is included along with an actuator control circuit connected with the actuator and responsive to error intelligence for imparting pivotal motion to the platform. Relocation of the engine's thrust vector is thus achieved for imparting directional stability to the vehicle.

Perkins, H.↗

Multiprocessor sparse L/U decomposition with controlled fill-in

Generation of the maximal compatibles of pivot elements for a class of small sparse matrices is studied. The algorithm involves a binary tree search and has a complexity exponential in the order of the matrix. Different strategies for selection of a set of compatible pivots based on the Markowitz criterion are investigated. The competing issues of parallelism and fill-in generation are studied and results are provided. A technque for obtaining an ordered compatible set directly from the ordered incompatible table is given. This technique generates a set of compatible pivots with the property of generating few fills. A new hueristic algorithm is then proposed that combines the idea of an ordered compatible set with a limited binary tree search to generate several sets of compatible pivots in linear time. Finally, an elimination set to reduce the matrix is selected. Parameters are suggested to obtain a balance between parallelism and fill-ins. Results of applying the proposed algorithms on several large application matrices are presented and analyzed.

Alaghband, G.↗

Simulator scene display evaluation device

An apparatus for aligning and calibrating scene displays in an aircraft simulator has a base on which all of the instruments for the aligning and calibrating are mounted. Laser directs beam at double right prism which is attached to pivoting support on base. The pivot point of the prism is located at the design eye point (DEP) of simulator during the aligning and calibrating. The objective lens in the base is movable on a track to follow the laser beam at different angles within the field of vision at the DEP. An eyepiece and a precision diopter are movable into a position behind the prism during the scene evaluation. A photometer or illuminometer is pivotable about the pivot into and out of position behind the eyepiece.

Haines, R. F.↗

Prototype secondary mirror assembly design for the space infrared telescope facility

The authors describe the design of a liquid helium temperature prototype secondary mirror assembly (PSMA) under developement for the NASA Space Infrared Telescope Facility (SIRTF) program. The SIRTF secondary mirror assembly must operate below 4 K and provide highly precise two-axis dynamic tilting (chopping) in addition to the conventional functions needed by the SIRTF observatory. The PSMA design uses a fused quartz mirror kinematically attached at its center to an aluminum cruciform. The mirror/cruciform assembly is driven in tilt about its combined center of mass using a unique flexure pivot and a four-actuator control system with feedback provided by pairs of differential position sensors. The voice coil actuators are mounted on a second flexture-pivoted mass, enhancing servo system stability and isolating the telescope from vibration-induced disturbances. The mirror/cruciform and the reaction mass are attached to opposite sides of an aluminum mounting plate whose dimensional characteristics are nominally identical to those of the aluminum flexure pivot material. The mounting plate is connected to the outer housing by a six-degree-of-freedom focus and centering mechanism using pivoted actuation levers driven by lead screw/harmonic drive/stepper motor assemblies.

Stier, M.↗