Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOTUBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The fused-silica Cherenkov detector system for the Qweak experiment

The Qweak experiment will measure the proton's weak charge via the parity-violating asymmetry in electron-proton scattering, measuring the asymmetry to a precision of 5~parts per billion. A continuous $\sim 180~\mu$A beam of polarized 1.1~GeV electrons interacts with a 35~cm liquid hydrogen target. Elastically scattered electrons with momentum transfer $Q^2 \approx 0.03$~GeV$^2$ are focused onto an array of eight fused silica detectors, each 2~m long. Cherenkov light emitted inside the silica is collected by photomultiplier tubes. The typical electron rate in each detector is $\sim$700~MHz; during production data-taking, the photocurrent is measured continuously by low-noise integrating electronics. The accelerator can also deliver the same beam at much lower currents ($\sim100$~pA); for these measurements, the phototubes can be connected to higher-gain fast electronics capable of resolving single-electron events. In this talk I will describe the construction, operation, and performance of these detectors.

Mahurin, Robert↗

Qweak Main Detector Status

The Qweak experiment at Jefferson Laboratory will make the first measurement of the weak charge of the proton. Because this electroweak observable is suppressed in the Standard Model, even the modest projected 4\% uncertainty will allow us to constrain new electron-quark interactions at the multi TeV-scale. The weak charge is accessed through the small ($<$ 1 ppm), parity-violating asymmetry in the elastic scattering of longitudinally polarized electrons from unpolarized protons. Scattered electrons which pass through fused silica bars emit Cerenkov light which is collected and converted to current by phototubes. Most large procurements and R\&D are complete. The status of the construction effort will be summarized. We remain on-track for installation in Spring 2009.

Mack, David↗

IceCube: An Instrument for Neutrino Astronomy

Neutrino astronomy beyond the Sun was first imagined in the late 1950s; by the 1970s, it was realized that kilometer-scale neutrino detectors were required. The first such instrument, IceCube, is near completion and taking data. The IceCube project transforms a cubic kilometer of deep and ultra-transparent Antarctic ice into a particle detector. A total of 5,160 optical sensors are embedded into a gigaton of Antarctic ice to detect the Cherenkov light emitted by secondary particles produced when neutrinos interact with nuclei in the ice. Each optical sensor is a complete data acquisition system, including a phototube, digitization electronics, control and trigger systems and LEDs for calibration. The light patterns reveal the type (flavor) of neutrino interaction and the energy and direction of the neutrino, making neutrino astronomy possible. The scientific missions of IceCube include such varied tasks as the search for sources of cosmic rays, the observation of Galactic supernova explosions, the search for dark matter, and the study of the neutrinos themselves. These reach energies well beyond those produced with accelerator beams.

79 ASTRONOMY AND ASTROPHYSICS↗

A Fast Pulse, High Intensity Neutron Source Based Upon The Dense Plasma Focus

Alameda Applied Sciences Corporation (AASC) has built a bench-top source of fast neutrons (approx10-30 ns, 2.45 MeV), that is portable and can be scaled to operate at approx100 Hz. The source is a Dense Plasma Focus driven by three different capacitor banks: a 40 J/30 kA/100 Hz driver; a 500 J/130 kA/2 Hz driver and a 3 kJ/350 kA/0.5 Hz driver. At currents of approx130 kA, this source produces approx1x10{sup 7} (DD) n/pulse. The neutron pulse widths are approx10-30 ns and may be controlled by adjusting the DPF electrode geometry and operating parameters. This paper describes the scaling of the fast neutron output with current from such a Dense Plasma Focus source. For each current and driver, different DPF head designs are required to match to the current rise-time, as the operating pressure and anode radius/shape are varied. Doping of the pure D{sub 2} gas fill with Ar or Kr was shown earlier to increase the neutron output. Results are discussed in the light of scaling laws suggested by prior literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trigger for Experiment with Hypernuclei

The hypernuclear program at Dubna was started in 1988 with investigation of the light hypernuclei production and decay. Nowadays we are planning to measure lifetime and cross section of {sub L}AMBDA{sup 3}H and {sub L}AMBDA{sup 4}H hypernuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time Resolution of Fast Photomultipliers for Time of Flight PET

Time resolution study of 1 inch Photonis XP1020 photomultiplier is reported. The number of photoelectrons, time jitter and time resolution with 4x4x20 mm{sup 3} LSO crystal were measured. All the mentioned PMT properties were measured at five positions on the photocathode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cosmic Ray Telescope For Educational Purposes

Cosmic ray detectors are widely used, for educational purposes, in order to motivate students to the physics of elementary particles and astrophysics. Using a 'telescope' of scintillation counters, the directional characteristics, diurnal variation, correlation with solar activity, can be determined, and conclusions about the composition, origin and interaction of elementary particles with the magnetic field of earth can be inferred. A telescope was built from two rectangular scintillator panels with dimensions: 91.6x1.9x3.7 cm{sup 3}. The scintillators are placed on top of each other, separated by a fixed distance of 34.6 cm. They are supported by a wooden frame which can be rotated around a horizontal axis. Direction is determined by the coincidence of the signals of the two PMTs. Standard NIM modules are used for readout. This device is to be used in the undergraduate nuclear and particle physics laboratory. The design and construction of the telescope as well as some preliminary results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MICROSTRUCTURED OPTICAL FIBER FOR X-RAY DETECTION

A novel scintillating optical fiber is presented using a composite micro-structured quartz optical fiber. Scintillating materials are introduced into the multiple inclusions of the fiber. This creates a composite optical fiber having quartz as a cladding with an organic scintillating material core. X-ray detection using these fibers is compared to a collimated cadmium telluride (CdTe) detector over an energy range from 10 to 40 keV. Results show a good correlation between the fiber count rate trend and that of the CdTe detector.

36 MATERIALS SCIENCE↗

Liquid Scintillation Detectors for High Energy Neutrinos

Large open volume (not segmented) liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region. We describe the potential employment of large detectors (>1 kiloton) for studies of higher energy neutrino interactions, such as cosmic rays and long-baseline experiments. When considering the physics potential of new large instruments the possibility of doing useful measurements with higher energy neutrino interactions has been overlooked. Here we take into account Fermat's principle, which states that the first light to reach each PMT will follow the shortest path between that PMT and the point of origin. We describe the geometry of this process, and the resulting wavefront, which we are calling the 'Fermat surface', and discuss methods of using this surface to extract directional track information and particle identification. This capability may be demonstrated in the new long-baseline neutrino beam from Jaeri accelerator to the KamLAND detector in Japan. Other exciting applications include the use of Hanohano as a movable long-baseline detector in this same beam, and LENA in Europe for future long-baseline neutrino beams from CERN. Also, this methodology opens up the question as to whether a large liquid scintillator detector should be given consideration for use in a future long-baseline experiment from Fermilab to the DUSEL underground laboratory at Homestake.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R and D on Proton Extinction Monitor for COMET Project

The COMET experiment searches for a muon to electron conversion process that is one of the lepton flavor violation processes. We use an 8-GeV pulsed proton beam. The proton extinction ratio is an important parameter. In order to measure this ratio pulse-by-pulse, we are developing a monitoring device. This device is called Proton Extinction Monitor and is a gas Cerenkov detector with gating photomultiplier tubes(PMT). The result of the investigation is that ethane is a promising gas for the Cerenkov radiator gas. A gating PMT is under development. We fabricated a divider circuit which switches at 10-kHz and has a cutoff ratio of 10{sup -6}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High Resolution Phoswich Detector: LaBr{sub 3}(Ce) Coupled With LaCl{sub 3}(Ce)

An innovative solution for the forward end-cap CALIFA calorimeter of R{sup 3}B is under investigation consisting of two scintillation crystals, LaBr{sub 3} and LaCl{sub 3}, stacked together in a phoswich configuration with one readout only. This dispositive should be capable of a good determination of the energy of protons and gamma radiation. This composite detector allows to deduce the initial energy of charged particles by DELTAE1+DELTAE2 identification. For gammas, the simulations show that there is a high probability that the first interaction occurs inside the scintillator at few centimeters, with a second layer, the rest of the energy is absorbed, or it can be used as veto event in case of no deposition in the first layer. One such a detector has been tested at the Centro de MicroAnalisis de Materiales (CMAM) in Madrid. Good resolution and time signal separation have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of a Single Water Cerenkov Detector to Monitor Forbush Decreases

We describe a simple experimental setup to measure the rate of arrival of muons at the surface of the Earth by using a single water Cerenkov detector and home-made electronics. We find a strong anti-correlation between the muon rates averaged over one-hour periods and the atmospheric pressure, with a measured correlation coefficient of -0.67% per hPa. After applying this correction we achieve sufficient sensitivity to observe long term (hours) variations in the averaged muon rates which are greater than 2%. Forbush decreases as big as 4% have been observed with muon detectors located at similar magnetic rigidities compared to Morelia, therefore our experimental setup will detect Forbush decreases as soon as the Sun enters into a more active phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Parallel Image Detection System Using Annular Pupils for Scanning Transmission Electron Microscope

A parallel image detection system using an annular pupil for electron optics were developed to realize an increase in the depth of focus, aberration-free imaging and separation of amplitude and phase images under scanning transmission electron microscopy (STEM). Apertures for annular pupils able to suppress high-energy electron scattering were developed using a focused ion beam (FIB) technique. The annular apertures were designed with outer diameter of oe 40 {mu}m and inner diameter of oe32 {mu}m. A taper angle varying from 20 deg. to 1 deg. was applied to the slits of the annular apertures to suppress the influence of high-energy electron scattering. Each azimuth angle image on scintillator was detected by a multi-anode photomultiplier tube assembly through 40 optical fibers bundled in a ring shape. To focus the image appearing on the scintillator on optical fibers, an optical lens relay system attached with CCD camera was developed. The system enables the taking of 40 images simultaneously from different scattered directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geo-Neutrinos And Radiogenic Contribution To Earth's Heat Flow

New measurements of the geo-neutrino flux are available from two independent and complementary experiments: Borexino and KamLAND. These new data decrease uncertainties on the flux and the derived radiogenic contribution to the terrestrial heat flow begins to be significant. The derived heat flow has a theoretical uncertainty from the accepted model of Earth. In the new future the range of the predictions should decrease mainly because of larger statistics collected by the two experiments and of a detailed geological study of the region near Borexino.

58 GEOSCIENCES↗

First Results of the Experiment to Search for 2{beta} Decay of {sup 106}Cd with the Help of {sup 106}CdWO{sub 4} Crystal Scintillators

An experiment to search for 2b processes in {sup 106}Cd with the help of {sup 106}CdWO{sub 4} crystal scintillator (mass of 215 g), enriched in {sup 106}Cd up to 66%, is in progress at the Gran Sasso National Laboratories of the INFN (Italy). After 1320 h of data taking, limits on double beta processes in {sup 106}Cd have been established on the level of 10{sup 19}-10{sup 20} yr, in particular (all the results at 90% C.L.): T{sub 1/2}(0{nu}2{epsilon})>3.6x10{sup 20} yr, T{sub 1/2}(2{nu}{epsilon}{beta}{sup +})>7.2x10{sup 19} yr, and T{sub 1/2}(2{nu}2{beta}{sup +})>2.5x10{sup 20} yr. Resonant 0{nu}2{epsilon} processes have been restricted as T{sub 1/2}(0{nu}2K)>1.4x10{sup 20} yr and T{sub 1/2}(0{nu}LK)>3.2x10{sup 20} yr. A possible resonant enhancement of the 0{nu}2{epsilon} processes is estimated in the framework of the QRPA approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surface backgrounds in the DEAP-3600 dark matter experiment

DEAP-3600 is a dark matter experiment using 3.6 tons of liquid argon to search for Weakly Interacting Massive Particles (WIMPs), with a target sensitivity to the spin-independent WIMP-nucleon cross-section of 10{sup -46} cm{sup 2}. The detector is designed to allow for a three year background-free run with a 1-ton fiducial volume. We identify in this paper the potential sources of surface contamination. We require {sup 238}U and {sup 232}Th contaminations on the order of 10{sup -12} g/g or less, a level achieved by the SNO experiment, and {sup 210}Pb not significantly out of equilibrium with {sup 238}U, i.e., 10{sup -20} g/g or less {sup 210}Pb in the acrylic vessel or TPB wavelength shifter, which should be achievable with appropriate control of exposure to radon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Study of Radon Background in the XENON100 Experiment

The XENON100 Dark Matter experiment has recently published first results from an analysis of 11.2 live days of data, setting an upper limit on the spin-independent WIMP-nucleon elastic scattering cross section of 3.4x10{sup -44} cm{sup 2} at 55 GeV/c{sup 2} and 90% confidence level. This article focuses on one specific background component of the XENON100 detector by presenting two independent methods of measuring the {sup 222}Rn concentration during operation phase. A first estimate of radon activity is derived for the 11.2 days analysis, proving the feasibility of on-line radon monitoring. Remaining systematic uncertainties are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗