Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Elastin cross-linking in the skin from patients with amyotrophic lateral sclerosis

Two cross-links unique to elastin, desmosine and isodesmosine were measured and compared in skin tissue (left upper arm) from 10 patients with amyotrophic lateral sclerosis (ALS) and from seven age-matched controls. The contents of desmosine and isodesmosine were significantly decreased (p < 0.01 and p < 0.01, respectively) in patients with ALS compared with those of controls, and were negatively and significantly associated with duration of illness in ALS patients (r = -0.77, p < 0.01 and r = -0.65, p < 0.05, respectively). The decline in skin desmosine and isodesmosine is more rapid in ALS than in normal ageing. Thus cross-linking of skin elastin is affected in ALS.

Non-NASA Center↗

Use of lower body negative pressure to counter symptoms of orthostatic intolerance in patients, bed rest subjects, and astronauts

This report briefly discusses some aspects of autonomic cardiovascular dysfunction as related to changes in orthostatic function in patients, bed rest subjects, and astronauts. This relationship is described in normal individuals to provide the basis for discussion of parameters that may be altered in patients, bed rest subjects, and astronauts. The relationships between disease states, age, periods of weightlessness during space flight, and autonomic dysfunction, and their contribution to changes in orthostatic tolerance are presented. The physiologic effects of lower body negative pressure are illustrated by presenting data obtained in bed rest subjects and in astronauts. Finally, the usefulness of lower body negative pressure to counter symptoms of orthostatic intolerance in patients, bed rest subjects, and astronauts is discussed.

Review, Tutorial↗

Elevated 1,25-dihydroxyvitamin D levels in patients with chronic obstructive pulmonary disease treated with prednisone

Glucocorticoid administration is a well established cause of osteopenia. Mechanisms underlying the deleterious effect of glucocorticoids on bone may include direct inhibition of bone formation as well as indirect effects through changes in intestinal calcium absorption, renal calcium excretion, and/or levels of the calciotropic hormones. To further examine the potential role of the calciotropic hormones we measured serum levels of PTH and 1,25 dihydroxyvitamin D [1,25(OH)2D], as well as serum and urine levels of calcium and vertebral bone density in patients with chronic obstructive pulmonary disease being managed with or without prednisone. Patients treated with prednisone had lower spinal bone density (53 vs. 106 mg/cm3) and higher serum calcium (2.40 vs. 2.33 mmol/l), urine calcium (6.9 vs. 2.7 mmol/24h), and 1,25(OH)2D levels (147 vs. 95 pmol/L). Compared to the patients not treated with glucocorticoids. PTH levels also tended to be higher (33 vs. 26 microliters-eq/ml), but the difference was not significant. Serum and urine calcium levels correlated positively with 1,25(OH)2D levels, but none of these measurements correlated with PTH levels. Our results suggest that prednisone treatment alters the regulation of 1,25(OH)2D production, and this may contribute to the loss of bone mineral induced by prednisone.

NASA Discipline Number 40-40↗

Fatigue mechanisms in patients with cancer: effects of tumor necrosis factor and exercise on skeletal muscle

Fatigue is a common adverse effect of cancer and its therapy. However, the specific mechanisms underlying cancer fatigue are unclear. One physiologic mechanism may involve changes in skeletal muscle protein stores or metabolite concentration. A reduction in skeletal muscle protein stores may result from endogenous tumor necrosis factor (TNF) or from TNF administered as antineoplastic therapy. This muscle wasting would require patients to exert an unusually high amount of effort to generate adequate contractile force during exercise performance or during extended periods of sitting or standing. This additional effort could result in the onset of fatigue. Additionally, cancer fatigue may develop or become exacerbated during exercise as a consequence of changes in the concentration of skeletal muscle metabolites. These biochemical alterations may interfere with force that is produced by the muscle contractile proteins. These physiologic changes may play a role in the decision to include exercise in the rehabilitation plans of patients with cancer. They also may affect ideas about fatigue.

Review, Tutorial↗

Automatic patient respiration failure detection system with wireless transmission

Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

Dimeff, J.↗

Inflatable stretcher to transport patients

Inflatable plastic bag inside strong, inflexible outer bag facilitates emergency transport of seriously burned or disabled patients. When the bag is inflated the patient is completely immobilized and cushioned from external shock. Air for breathing, temperature controls and communications may be provided by appropriate plug-in connections.

Clark, C. C.↗

Viscoelastic cushion for patient support

Flexible container, filled with liquid, provides supportive device which conforms to patient's anatomy. Uniform cushion pressure prevents formation of decubitus ulcers, while the porous sponge substructure damps fluid movement through cushion response so that patient is not dumped when his weight shifts.

Sauers, D. G.↗

Patient's breath controls comfort devices

Patient assist system for totally disabled persons was developed which permits a person, so paralyzed as to be unable to move, to activate by breathing, a call system to summon assistance, turn the page of a book, ajust his bed, or do any one of a number of other things. System consists of patient assist control and breath actuated switch.

Schrader, M.↗

New system for bathing bedridden patients

Multihead shower facility can be used with minimal patient handling. Waterproof curtain allows patient to bathe with his head out of shower. He can move completely inside shower to wash his face and hair. Main advantage of shower system is time saved in giving bath.

Greenleaf, J. E.↗

The Coronary Patient in Industry

The coronary patient, as he pertains to industry particularly NASA, is discussed. Concepts of precoronary care, acute attacks which may develop while on the job, and the return of the cardiac patient to work are covered. Major emphasis was on the prevention of sudden death due to coronary disease.

Schuster, B.↗

Engineering test procedure for the patient assist device

The test procedure completely tests the functioning of the patient assist device. All modes of operation are included in the test. Patient activated switches may be chosen for use with this device as desired. These switches, however, must be single-pole, single-throw, momentarily-on switches.

Schroder, M. A.↗

Biotelemetry system for ambulatory patients

Compact transmitter for multichannel telemetry of medical data is carried in patient's belt. Pulse-code modulation (PCM), is used for high-quality signal, and low-power CMOS integrated circuits make miniaturization possible. Transmitter is useful for electro-encephalograms (EEG) and electro-cardiograms (EKG) and other biomedical patient-monitoring situations.

Fryer, T. B.↗

The role of technetium-99m stannous pyrophosphate in myocardial imaging to recognize, localize and identify extension of acute myocardial infarction in patients

The ability of technetium-99m stannous pyrophosphate myocardial scintigrams to aid diagnostically in recognizing, localizing, and identifying extension of acute myocardial infarction in patients was evaluated. The present study is an extension of previous animal and patient evaluations that were recently performed utilizing this myocardial imaging agent.

Willerson, J. T.↗

Assessment of left ventricular ejection fraction by radionuclide angiography. Comparison to echocardiography and serial measurements in patients with myocardial infarction

Measurements of the left ventricular ejection fraction were compared in patients with previous myocardial infarctions. Left ventricular ejection fraction was measured by the radioisotopic method serially in patients early after an acute myocardial infarction and during the convalescence period. Ultrasound recordings were obtained utilizing a commercially available ultrasonoscope and a 1/9 cm transducer focused at 10 cm with a repetition rate of 1000 impulses per second. All recordings were made on a visicorder oscillography.

Schelbert, H. R.↗

User requirements for a patient scheduling system

A rehabilitation institute's needs and wants from a scheduling system were established by (1) studying the existing scheduling system and the variables that affect patient scheduling, (2) conducting a human-factors study to establish the human interfaces that affect patients' meeting prescribed therapy schedules, and (3) developing and administering a questionnaire to the staff which pertains to the various interface problems in order to identify staff requirements to minimize scheduling problems and other factors that may limit the effectiveness of any new scheduling system.

Zimmerman, W.↗

Earth horizontal axis rotational responses in patients with unilateral peripheral vestibular deficits

The vestibulo-ocular reflex (VOR) of five patients with surgically confirmed unilateral peripheral vestibular lesions is evaluated. Testing used both earth vertical axis (EVA) and earth horizontal axis (EHA) yaw rotation. Results indicated that the patients had short VOR time constants, asymmetric responses to both EVA and EHA rotation, and normal EHA modulation components. These findings suggest that unilateral peripheral vestibular loss causes a shortened VOR time constant even with the addition of dynamic otolithic stimulation and causes an asymmetry in semicircular canal-ocular reflexes and one aspect of otolith-ocular reflexes.

Furman, Joseph M. R.↗

Space Technology for Patient Monitoring

A contract for the development of an astronaut monitoring system in the early days of the space program provided Mennen Medical, Inc. with a foundation in telemetry that led to the development of a computerized medical electronic system used by hospitals. Mennen was the first company to adopt solid state design in patient monitoring and to offer multipatient telemetry monitoring. Telemetry converts instrument data to electrical signals and relays them to a remote receiver where they are displayed. From a central station, a nurse can monitor several patients. Company products include VISTA systems and Horizon 2000 Monitor.

Source record↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗