Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Overheating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cooling method prolongs life of hot-wire transducer

To cool a hot-wire transducer, the two ends of the wire are supported on thermally and electrically conductive rods, surrounded by a fluid cooling medium. By keeping the supporting rods at a substantially constant temperature, the probe is prevented from overheating.

Baldwin, L. V.

Hypersonic research engine project. Phase 2: Structures and cooling development

The structures assembly model (SAM) was installed, and wind tunnel systems were checked out. The first run, with hydrogen cooling and SAM inserted in the wind tunnel stream (M = 7.7, P sub TOTAL = 900 psia, T sub TOTAL = 2500 deg R), was accomplished. The condition of the SAM after the run was satisfactory, with no visible signs or data indications of overheating or overloading.

Jilly, L. F.

Balloon-borne package temperature controller

Simple, inexpensive, lightweight enclosure traps upward long wave radiation of earth while reflecting harsh solar radiation in upper atmosphere. It warms enclosed instruments in cold regions and protects them from overheating during the day. Device can be attached to balloon system without any changes in experimental design.

Schach, M.

Phenomena associated with bench and thermal-vacuum testing of super conductors - Heat pipes.

Test failures of heat pipes occur when the functional performance is unable to match the expected design limits or when the power applied to the heat pipe (in the form of heat) is distributed unevenly through the system, yielding a large thermal gradient. When a thermal gradient larger than expected is measured, it normally occurs in the evaporator or condenser sections of the pipe. Common causes include evaporator overheating, condenser dropout, noncondensable gas formation, surge and partial recovery of evaporator temperatures, masking of thermal profiles, and simple malfunctions due to leaks and mechanical failures or flaws. Examples of each of these phenomena are described along with corresponding failure analyses and corrective measures.

Marshburn, J. P.

Start-stop testing of two self-acting air-lubricated spiral groove thrust bearing coatings

Start-stop tests were conducted on air-lubricated spiral-groove thrust bearings. Application of a matrix-bonded molybdenum disulfide (MoS2) coating over a porous chrome oxide coating resulted in significantly lower friction, compared to bearings coated with chrome oxide only. The MoS2 coated bearing sustained 15,000 start-stop cycles at a maximum of 3600 rpm. Each cycle was 15 seconds on, 30 seconds off. The chrome oxide coated bearing failed by local welding after 2030 cycles. Both types of coatings exhibited early failures under higher thrust loads when operating films were insufficient to sustain the load without overheating.

Dunfee, J. D.

Wind tunnel investigation of a simulated gunship helicopter engine-exhaust-windstream interaction

A wind tunnel investigation of the engine exhaust and windstream flow interaction on a gunship helicopter model was conducted in the Langley V/STOL tunnel. The investigation utilized a flow visualization technique employing neutrally buoyant helium filled bubbles to determine the cause of exhaust shield overheating during cruising flight and to evaluate means of eliminating the problem. The flow patterns were recorded with still cameras and on television magnetic tape. Exhaust flow impingement on the exhaust shield during cruise was found to cause the problem. Several flow altering devices were evaluated to find suitable ways to correct the problem. A flow deflector located on the model cowling upstream of the exhaust provides an effective solution.

Wilson, J. C.

Technology of forced flow and once-through boiling: A survey

Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).

Poppendieck, H. F.

OH-58 helicopter transmission failure analysis

The OH-58 main transmission gearbox was run at varying output torques, speeds, and oil cooling rates. The gearbox was subsequently run to destruction by draining the oil from the gearbox while operating at a speed of 6200 revs per minute and 36,000 inch-pounds output torque. Primary cause of gearbox failure was overheating and melting of the planet bearing aluminum cages. Complete failure of the gearbox occurred in 28 1/2 minutes after the oil pressure dropped to zero. The alternating and maximum stresses in the gearbox top case were approximately 10 percent of the endurance limit for the material. Deflection of the bevel gear at 67000 inch-pounds output torque indicate a marginal stiffness for the bevel gear supporting system.

Townsend, D. P.

Rolling-element fatigue life with two synthetic cycloaliphatic traction fluids

The life potential of two synthetic cycloaliphatic hydrocarbon traction fluids in rolling element fatigue was evaluated in a five ball fatigue tester. Life comparisons with a MIL-L-23699 qualified tetraester oil showed that the traction test oils had good fatigue life performance, comparable to that of the tetraester oil. No statistically significant life differences between the traction fluids and the tetraester oil were exhibited under the accelerated fatigue test conditions. Erratic operating behavior was occasionally encountered during tests with the antiwear additive containing traction fluid for reasons thought to be related to excessive chemical activity under high contact pressure. This behavior occasionally resulted in premature test termination due to excessive surface distress and overheating.

Loewenthal, S. H.

Teledyne Continental Motors emissions data and analysis and flight test results

Five different engine models were tested covering combinations of all engine categories in current production in the range from 100 to 435 brake horsepower. Engines were divided into five major types: carbureted, fuel injected, direct drive, geared, and turbocharged. Emissions data were categorized by three separate fuel system schedules: baseline, case 1, and case 2. Baseline was defined as the average fuel flow rate established by the fuel system's production tolerance band when operated with the mixture control at the full-rich position. Case 1 was defined as the minimum allowable fuel flow rate established by the engine certification. Case 2 was defined as the fuel rate corresponding to the leanest fuel-air ratio obtainable before a safety limit occurred with the engine operating on a propeller test stand. Safety limits that developed during testing were cylinder-head overheating or inadequate acceleration from a given mode of operation.

Rezy, B. J.

Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

Shannon, A. V.

Update on development of the Space Shuttle main engine /as of 5 May 1977/

The development and testing of the Space Shuttle main engine are described. The preburners, main injector, main combustion chamber, and 35:1 expansion ratio test nozzle were successfully run at full power level (109 percent of rated power level). Integral combustion stability aids damped induced instability oscillations within 6 milliseconds. Three significant turbomachinery problems were identified and solved during the past year. These problems involved high-pressure fuel turbopump subsynchronous whirl, severe overheating of the turbine bearing and components and, in the high-pressure oxidizer turbopump, burning that first occurred in the drain cavity downstream of the primary oxidizer seal.

Johnson, J. R.

Types of rotor failure and characteristics of fragments

Noncontained rotor failures in U.K. engines resulting from low cycle fatigue, low cycle fatigue with superimposed high cycle fatigue, and overheating and-or overspeeding were analyzed. The size, shape, weight, velocity, energy, and direction of the fragments released from turbines and compressors were studied and are presented in graph.

Mccarthy, D.