Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Outdoor environmental”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Data to Accompany: PM2.5 is insufficient to explain personal PAH exposure

Fine particulate matter (PM2.5) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. We hypothesized that predictive models for personal chemical exposure would be significantly improved by expanding beyond stationary PM2.5 AQI data or satellite HMS data to also include environmental and behavioral information. In Eugene, Oregon, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a seven-day period in multiple seasons. We gathered publicly available daily PM2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons (PAHs). Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM2.5 AQI only, HMS only, and a multivariate feature set including PM2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.

Bramer, Lisa M↗

Suspended Membrane Evaporators Integrating Environmental and Solar Evaporation for Oily Wastewater Purification

Solar-driven evaporation is promising in oily wastewater treatment, in particular for emulsions, but conventional evaporators suffer from pore blocking by residual oil or contamination by volatile oil compounds in the condensed water. In the current research, we develop a suspended membrane evaporator integrating solar evaporation with oil-in-water emulsion separation. The heating and evaporating interface is separated from the rejecting interface to avoid oil escape and improve heat management. A temperature gradient forms on the membrane surface that can promote evaporation performance by combining both solar and environmental evaporation. Such an evaporator achieves a maximum evaporation rate of 1.645 kg/(m 2 ·h) as well as an apparent evaporation efficiency of 111.9%. Moreover, the superhydrophilic and superoleophobic membrane shows excellent oil repellence and emulsion rejection, which can achieve an oil removal efficiency above 98.8% in oil-in-water emulsion separation, and high evaporation rate recovery in cycling tests. Furthermore, a scaled-up membrane evaporator array produces ~8 kg/(m 2 ·d) of clean water from oily wastewater in outdoor experiments, further demonstrating the strong purification performance of this evaporator in oily wastewater treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Is Clean Hydrogen Production a Good Fit for Questa? (Final Economic Impact Results) [Slides]

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

Is Clean Hydrogen Production a Good Fit for Questa? Final Economic Impact Results

The Village of Questa, New Mexico is aiming to become a regional clean energy hub with robust and diverse employment opportunities for the local community supported by the energy sector and by other businesses inspired or attracted by abundant clean energy, outdoor recreation, and cultural opportunities. A coalition of stakeholders in the Village of Questa, comprising the Village, Kit Carson Electric Cooperative (KCEC), Questa Economic Development Fund, and Chevron, is exploring options to develop hydrogen production facilities as an opportunity to create jobs, provide reliable clean energy, and utilize former mine resources. Questa is home to a molybdenum mine owned by Chevron that closed in 2014. Several residents in Questa and surrounding communities lost their jobs when the mine closed and transitioned from active operations into environmental remediation. Although remediation efforts have been ongoing since 2014 and are expected to continue for at least 16 more years, the number of jobs with Chevron is much smaller now than it was before the closure. Between available workforce, brownfield land, and water rights formerly supporting mine operations but now in a transition period, there are considerable local resources that could be directed toward clean energy generation. Questa's electricity supply is already 100% solar during daylight hours thanks to Kit Carson Electric Cooperative's (KCEC's) strategic decision-making and partnering over the last decade. Now, Questa, KCEC, and Chevron are exploring the potential costs and benefits of siting an electrolytic hydrogen production facility and additional solar photovoltaic (PV) capacity in Questa to further advance the region's clean energy economy. In this report, we estimated the potential economic impacts (i.e., jobs, value added, gross output, tax revenue) of constructing and operating a combined hydrogen (32 MW polymer electrolyte membrane electrolizer + 7.5 MW fuel cell) and solar facility (22.5 MW) in the Village of Questa, as well as the resulting economic spillovers to Taos County and the state of New Mexico. We employ an input-output model that leverages IMPLAN's economic data for the region complemented by construction and operating expenses estimated by NREL and feedback from the local coalition to evaluate the direct, indirect and induced effects of the project construction (transient impacts) and operation (more permanent impacts). Based on the area's average trade profile, feedback from the coalition and current market conditions, these projects are expected to support 487 full-time equivalent jobs during construction, generating $\$24$ million in income for those workers and $\$82$ million in local economic activity in the state. Of those jobs, 106 are expected to be construction sector jobs. These investments are also estimated to add $\$36.5$ million to New Mexico's gross state product (GSP). In the Village of Questa, we estimate 16 jobs will be supported in construction and transportation industries, generating $\$0.9$ million in earnings. In Taos County, the construction phase is expected to support 285 jobs primarily in construction and professional services, while manufacturing jobs dominate the results for the Rest of New Mexico. The Village is also estimated to receive $\$0.9$ million in tax revenue from the construction phase alone. Once in operation, the project continues to impact the state and Questa. Around 20 jobs (full-time equivalent for each year of operation) are supported across New Mexico, with approximately 11 directly employed in Questa by both facilities. The total annual local economic activity supported by ongoing operations is just over $\$1.3$ million/yr, generating $\$1.6$ million/yr in additional income in the state. Annual operations are estimated to add $\$2.1$ million to the state's GSP. The Village is expected to receive around $\$43,000$/yr in tax revenue. Impacts vary significantly depending on which businesses are supplying materials, equipment and services, and where construction workers reside. Choosing local suppliers will most benefit Questa and the New Mexico economy, adding up to 500 jobs during construction and 13 long-term jobs. Local and state governments may consider ways to incentivize local businesses in order to maximize economic benefits.

08 HYDROGEN↗

Estimated impacts of forest restoration scenarios on smoke exposures among outdoor agricultural workers in California

Abstract As wildfires continue to worsen across western United States, forest managers are increasingly employing prescribed burns as a way to reduce excess fuels and future wildfire risk. While the ecological benefits of these fuel treatments are clear, little is known about the smoke exposure tradeoffs of using prescribed burns to mitigate wildfires, particularly among at-risk populations. Outdoor agricultural workers are a population at increased risk of smoke exposure because of their time spent outside and the physical demands of their work. Here, we assess the smoke exposure impacts among outdoor agricultural workers resulting from the implementation of six forest management scenarios proposed for a landscape in the Central Sierra, California. We leverage emissions estimates from LANDIS-II to model daily PM 2.5 concentrations with the Hybrid Single Particle Lagrangian Integrated Trajectory Model (HYSPLIT) and link those to agricultural employment data from the Bureau of Labor Statistics. We find a u-shaped result, in that moderate amounts of prescribed burning result in the greatest reduction in total smoke exposure among outdoor agricultural workers, particularly during months of peak agricultural activity due to wildfire-specific smoke reductions. The reduction in total smoke exposure, relative to scenarios with the least amount of management, decreases as more prescribed burning is applied to the landscape due to the contributions of the fuel treatments themselves to overall smoke burden. The results of this analysis may contribute to preparedness efforts aimed at reducing smoke exposures among outdoor agricultural workers, while also informing forest management planning for this specific landscape.

Environmental Sciences & Ecology↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 72 Outdoor Live Fire Range Storage Units Installation Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction in lower Sandia Canyon at Technical Area (TA) 72 at the Outdoor Live Fire Range facility at Los Alamos National Laboratory (LANL). The proposed project is intended to provide storage for firing range supplies and consumables. The project activities within the 100-year floodplain include installation of at least seven prefabricated metal transportainer type storage units located at one of four locations (Figure 1).

54 ENVIRONMENTAL SCIENCES↗

Simulation-Based Analysis of Impacts of Reduced Envelope and Duct Air Leakage on Indoor Air Pollutant Concentrations in Occupied Manufactured Homes

This report presents a simulation-based analysis that estimates the magnitude of indoor air pollutant concentration changes that could result from the proposed energy conservation standards. The analysis was conducted for a 1568 ft 2 , double-wide MH with variations in heating and cooling equipment (either furnace + air conditioner or heat pump) and various types of whole-house mechanical ventilation (continuous exhaust fan or central fan integrated supply), in three locations with varying climate conditions: Chicago IL, Fresno, CA; and Houston TX. The simulations tracked four air pollutants that can reach levels exceeding established safe target levels in homes: acrolein, formaldehyde, fine particulate matter (PM 2.5 ), and nitrogen dioxide (NO 2 ). The simulations considered acrolein and formaldehyde emitted from continuous indoor sources; acrolein, NO 2 and PM 2.5 from cooking; PM 2.5 from dispersed occupant activities; and NO 2 and PM 2.5 from outdoors, using historical data to identify typical levels. The impacts in homes operating or not operating whole-house mechanical ventilation equipment, kitchen and bath exhaust fans, and window opening as ventilation approaches were examined.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A model for selecting the best sustainable airport technology alternatives

Air transport is a continually expanding industry, a fact that has become even more evident with the recovery of the aviation industry post-COVID-19. This expansion amplified energy consumption at airports, which was already significantly high. Airport decision-makers are increasingly focusing on improving sustainability and addressing social, economic, and environmental criteria across airports worldwide. In this article, we propose a decision-making model for identifying a sustainable airport technology solution that minimizes the energy consumption of airport lighting while considering economic, emission, and life-cycle criteria. The proposed model combines data envelopment analysis and multi-criteria decision making techniques. We applied the model to the Dallas/Fort Worth International Airport (DFW) as a case study, considering eight lighting technology solutions, each with five luminous flux alternatives. Our model identified the best lighting technology solution for DFW outdoor and indoor environments based on the following criteria: luminous flux, capital costs, life-cycle costs, energy consumption, and emissions (CO2e, NOx, SO2, and PM2.5). The designed model is customizable to any airport and is applicable to a wide range of airport lighting technologies. In our analysis, Light-Emitting Diode lighting emerged as the most sustainable technology option. It ranked first in most cases due to its balance of high efficacy, long lifespan, low life-cycle cost, low capital cost, and lower emissions across all pollutants.

Tchivwila, Moise B↗

The Eco-Bio-Social Factors That Modulate Aedes aegypti Abundance in South Texas Border Communities

Aedes aegypti control requires dedicated resources that are usually scarce, limiting the reach and sustainability of vector control programs. This generates a need to focus on areas at risk of disease transmission and also understand the factors that might modulate local mosquito abundance. We evaluated the eco-bio-social factors that modulate indoor and outdoor relative abundance of female Ae. aegypti in communities of South Texas. We conducted housing quality and Knowledge Attitudes and Practices surveys in households that were part of a weekly mosquito surveillance program in November of 2017 and 2018. Our results showed widespread knowledge of mosquitoes and Zika virus by our participants. However, less than 35% considered them as serious problems in this region. The presence of window-mounted air conditioning units increased the risk of female mosquito relative abundance indoors. An increase in outdoor relative abundance was associated with larger properties and a higher number of children between 6 to 17 years of age. Interestingly, we observed that an increasing number of children <5 years of age modulated both indoor and outdoor relative abundance, with a 52% increase indoors and 30% decrease outdoors. The low perception of mosquito and disease risk highlights engagement needs for vector-borne disease prevention in this region. The identified risk factors can help guide public health officials in their efforts to reduce human and vector contact.

54 ENVIRONMENTAL SCIENCES↗

Research needs targeting direct air capture of carbon dioxide: Material & process performance characteristics under realistic environmental conditions

The extraction of CO 2 from ambient air, or direct air capture (DAC), is a crucial negative CO 2 emissions technology with great potential for contributing to the mitigation of global warming and climate change. Furthermore, nearly all published research on DAC has been conducted under indoor temperature conditions, i.e. 20 to 30 °C. In contrast, the future global implementation of DAC requires it to be operational across a wide expanse of geographical areas, of which the local temperatures can vary between -30 to 50 °C. Similarly, the absolute humidity can vary from ~0 to 84 g/m 3 in various locations. Due to the massive amount of air that would be processed, it may be impractical to preheat or dehumidify the air before the CO 2 separation. Therefore, it is important to develop DAC materials with good performance at realistic outdoor conditions, especially at sub-ambient conditions, i.e. -30 to 20 °C. In addition to material development, system-level studies at sub-ambient conditions are also needed for the DAC processes to reach optimal designs, which may be very different from those at ambient conditions. In this perspective article, we first assess the literature to identify the technical gaps that need to be filled for DAC to be applicable at realistic outdoor conditions. We then suggest additional research directions needed for DAC to be viable under varied conditions from the perspectives of materials and system designs. For materials, we discuss the expected physical and chemical property changes for the sorbents when the temperature or humidity reaches extremes within their range, and how that will impact performance. Similarly, for system design, we indicate how varied conditions will impact performance and how these changes will impact process optimization.

20 FOSSIL-FUELED POWER PLANTS↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Compilation of a Solar Mirror Materials Database and an Analysis of Natural and Accelerated Mirror Exposure and Degradation

The National Renewable Energy Laboratory (NREL) has been conducting exposure experiments on solar reflectors for over four decades. Thousands of mirror samples from over one hundred suppliers have been exposed to and monitored in a range of relevant environments. These test conditions include outdoor test settings and several controlled laboratory environments. These samples have been rigorously individually characterized using a series of reflectance measurements, visual inspections, and in some cases, in-depth composition analysis to identify degradation modes, reflectance losses, and other mirror properties integral to understanding the solar reflector's life cycle. Here, this paper compiles the decades of measurement data into a concise statistical analysis. It includes exposure and degradation data for numerous reflector types, including secondary-surface reflector permutations of polymer and glass superstrates with silver and aluminum reflectors as well as front-surface reflectors. The results herein are intended to analyze environmental stressors and degradation trends among various historical and state-of-the-art solar reflectors. It may be used to support solar reflector design, effective testing methodology, and inform manufacturing decisions moving forward. Presented are the results of the compiled database and an initial analysis for degradation rate modeling using full-spectrum and wavelength-dependent approaches. The database is a growing resource hosted on a live, publicly accessible website. In conjunction with the analysis presented here, it provides a valuable resource to the solar reflector manufacturing and testing industry.

14 SOLAR ENERGY↗

Production of Biocrude in an Advanced Photobioreactor-Based Biorefinery

Algenol Biotech, the National Renewable Energy Laboratory (NREL), Georgia Institute of Technology, Arizona State University, and Reliance Industries formed a team to advance the state of the art in algal biomass production and downstream processing technologies, with the end goal of a sustainable, economically viable biofuel intermediate (BFI, biocrude) product. The project included examination of high value co-product production as a market entry strategy and for enhancing the economics of a biorefinery for BFI production. The project targeted innovations in biology, operations, and engineering. The goals of the project were: BFI productivity greater than 4,000 gal-BFI/acre-yr on an annualized basis; energy efficient innovations in downstream operations resulting in an energy expenditure less than 10% of the BFI energy content and a carbon footprint reduction of more than 60% compared to fossil alternatives; and a comprehensive Techno-Economic Analysis (TEA) that identifies limiting factors for commercial viability of a photobioreactor (PBR)-based biofuel product. The project achieved the overall objectives. Strain development efforts led to the identification of a strain (Cyanobacterium sp. AB1166) that, relative to the previous best strain (Cyanobacterium sp. AB1), exhibited a ~10% increase in productivity under commercially-relevant cultivation conditions and also resulted in cultures with a >50% reduction in viscosity such that harvesting efficiency was improved; these results represent achievement of key project milestones. Progress was also made at NREL in altering the biochemical composition of algal biomass to improve the yield of BFI produced via HTL. These strain enhancements coupled with improved outdoor cultivation practices, including semi-continuous operation, increased areal biomass productivity by nearly 80% over the established baseline productivity. The annualized productivity achieved (26.8 g/m2-d), paired with HTL conversion yields realized at NREL and RIL (38% ± 2% BFI), translates to 4,100 gal-BFI/acre-yr, exceeding the FY20 BETO goal of 3,700 gal-BFI/acre-yr. Significant progress was also demonstrated in large scale PBR-based production system design, operability, and cost reduction. A 24,000-L production module comprised of 240 interlinked PBRs was constructed and successfully operated outdoors for over one year in Fort Myers, Florida. Aided by a state-of-the-art productivity model, the productivities achieved convincingly demonstrated scalability of laboratory results determined at the mL to L scale to large-scale outdoor operations exceeding 20,000 L. The system was used to cultivate Arthrospira platensis (Spirulina), an industrially-relevant cyanobacterium and source for phycocyanin, an approved blue food colorant that Algenol is developing as a risk reduction strategy for future biofuel projects and as a potential business opportunity. A key project milestone to develop phycocyanin extraction and purification technologies was achieved ahead of schedule, and product samples received positive feedback from potential customers. The production and downstream operations data generated in this project were used to conduct and refine Techno-Economic and Life Cycle Assessments to provide research guidance for reducing the costs and environmental footprint of algal biofuel and co-product manufacturing plants. Several CO 2 supply scenarios for an algal biorefinery were identified as being capable of providing a large (>60%) reduction in carbon footprint in comparison to gasoline. The TEA assessments incorporated detailed comparisons of PBR versus open pond production systems, yielding a 3-fold higher areal productivity for PBRs and suggesting overall production cost parity for the two systems. The progress in this ABY2 project addressed many of the the barriers identified for the Advanced Algal Systems R&D Program and are directly relevant to achieving the established BETO goals associated with large scale biofuel production and cost reduction.

09 BIOMASS FUELS↗

Assessing residential PM 2.5 concentrations and infiltration factors with high spatiotemporal resolution using crowdsourced sensors

Building conditions, outdoor climate, and human behavior influence residential concentrations of fine particulate matter (PM 2.5 ). To study PM 2.5 spatiotemporal variability in residences, we acquired paired indoor and outdoor PM 2.5 measurements at 3,977 residences across the United States totaling >10,000 monitor-years of time-resolved data (10-min resolution) from the PurpleAir network. Time-series analysis and statistical modeling apportioned residential PM 2.5 concentrations to outdoor sources (median residential contribution = 52% of total, coefficient of variation = 69%), episodic indoor emission events such as cooking (28%, CV = 210%) and persistent indoor sources (20%, CV = 112%). Residences in the temperate marine climate zone experienced higher infiltration factors, consistent with expectations for more time with open windows in milder climates. Likewise, for all climate zones, infiltration factors were highest in summer and lowest in winter, decreasing by approximately half in most climate zones. Large outdoor–indoor temperature differences were associated with lower infiltration factors, suggesting particle losses from active filtration occurred during heating and cooling. Absolute contributions from both outdoor and indoor sources increased during wildfire events. Infiltration factors decreased during periods of high outdoor PM 2.5 , such as during wildfires, reducing potential exposures from outdoor-origin particles but increasing potential exposures to indoor-origin particles. Time-of-day analysis reveals that episodic emission events are most frequent during mealtimes as well as on holidays (Thanksgiving and Christmas), indicating that cooking-related activities are a strong episodic emission source of indoor PM 2.5 in monitored residences.

54 ENVIRONMENTAL SCIENCES↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Data and scripts from: “Denoising autoencoder for reconstructing sensor observation data and predicting evapotranspiration: noisy and missing values repair and uncertainty quantification”

This data package includes data and scripts from the manuscript “Denoising autoencoder for reconstructing sensor observation data and predicting evapotranspiration: noisy and missing values repair and uncertainty quantification”.The study addressed common challenges faced in environmental sensing and modeling, including uncertain input data, missing sensor observations, and high-dimensional datasets with interrelated but redundant variables. Point-scaled meteorological and soil sensor observations were perturbed with noises and missing values, and denoising autoencoder (DAE) neural networks were developed to reconstruct the perturbed data and further predict evapotranspiration. This study concluded that (1) the reconstruction quality of each variable depends on its cross-correlation and alignment to the underlying data structure, (2) uncertainties from the models were overall stronger than those from the data corruption, and (3) there was a tradeoff between reducing bias and reducing variance when evaluating the uncertainty of the machine learning models.This package includes:(1) Four ipython scripts (.ipynb): “DAE_train.ipynb” trains and evaluates DAE neural networks, “DAE_predict.ipynb” makes predictions from the trained DAE models, “ET_train.ipynb” trains and evaluates ET prediction neural networks, and “ET_predict.ipynb” makes predictions from trained ET models.(2) One python file (.py): “methods.py” includes all user-defined functions and python codes used in the ipython scripts.(3) A “sub_models” folder that includes five trained DAE neural networks (in pytorch format, .pt), which could be used to ingest input data before being fed to the downstream ET models in ‘ET_train.ipynb” or ‘ET_predict.ipynb’.(4) Two data files (.csv). Daily meteorological, vegetation, and soil data is in “df_data.csv”, where “df_meta.csv” contains the location and time information of “df_data.csv”. Each row (index) in “df_meta.csv” corresponds to each row in “df_data.csv”. These data files are formatted to follow the data structure requirements and be directly used in the ipython scripts, and they have been shuffled chronologically to train machine learning models. The meteorological and soil data was collected using point sensors between 2019-2023 at(4.a) Three shrub-dominated field sites in East River, Colorado (named “ph1”, “ph2” and “sg5” in “df_meta.csv”, where “ph1” and “ph2” were located at PumpHouse Hillslopes, and “sg5” was at Snodgrass Mountain meadow) and(4.b) One outdoor, mesoscale, and herbaceous-dominated experiment in Berkeley, California (named “tb” in “df_meta.csv”, short for Smartsoils Testbed at Lawrence Berkeley National Lab).- See "df_data_dd.csv" and "df_meta_dd.csv" for variable descriptions and the Methods section for additional data processing steps. See "flmd.csv" and "README.txt" for brief file descriptions.- All ipython scripts and python files are written in and require PYTHON language software.

54 ENVIRONMENTAL SCIENCES↗