Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical sources & detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ORFEUS-SPAS - The Berkeley EUV spectrometer

The Berkeley EUV spectrometer of ORFEUS-SPAS, a joint project of NASA and the BMFT, incorporates a set of four novel spherically figured, varied line-space gratings used in a geometry that is similar to that of the classic Rowland mount to span an interval of 390 and 1200 A. Two spectral detector units containing curved microchannel plates and delay-line anodes encode the arriving photons in digital format for telemetry. An additional optic directs the image of the source in the entrance aperture onto a sealed FUV detector which is used to track the source as it drifts during an observation, enabling a postflight reconstruction of the spacecraft pointing vector. This in turn makes it possible to define with precision the wavelength of each recorded photon.

Bowyer, Stuart↗

A Historical Overview of the NASA Orbital Debris Program Office’s Laboratory Optical Measurements

The NASA Orbital Debris Program Office (ODPO) has used laboratory measurements to help bring ground-based measurements together with models to ascertain Earth-orbiting target parameters of interest to support various orbital debris models. In 2005, the Optical Measurement Center (OMC) was established to simulate space-based illumination conditions using equipment and techniques that recreate telescopic observations, particularly source-target-sensor orientations. The intent was to recreate light curves using known aspect angles of known targets and phase angles (angle is defined by the vertex between illumination source-object-detector) to complement telescopic observations that could be used to update the current optical size estimation model (OSEM) – a model that converts object brightness into size for orbital debris models. To support the above goals, the laboratory has undergone several equipment upgrades to increase capabilities over almost 20 years of operation. The primary instrumentation acquires reflectance measurements and includes a solar-like light source, CCD camera with astrometric filters, and robotic arm. A rotary arm was added approximately five years after full operation to allow acquisition through a full 360° range of phase angles. Another part of the OMC instrumentation is a field spectrometer, predominately used for field operations to acquire pre- and post-flight spacecraft material spectral measurements. Additionally, reflectance spectroscopy of various materials is also of interest resulting from hypervelocity impact tests, pristine spacecraft materials, or samples of materials that are used in spacecraft design. These measurements are stored in NASA’s Spectral Material Database, a resource that is still being populated today. The study of spectral measurements also enabled the development of spectral unmixing routines to support the identification of spacecraft materials from spectral data gathered by ground based telescopes. Preliminary OMC investigations focused on feasibility studies to acquire 360° rotation light curves of simple shapes at a single-phase angle and extended to measurements of representative fragments from ground-based explosion tests. To correlate the light curves with ground-based optical measurements, a focused study on high area to mass materials was conducted in support of a newly identified population (at the time) in geosynchronous orbit (GEO) consisting of multi-layered insulation. To further characterize orbital debris, a larger selection of materials was analyzed using laboratory photometric measurements that included representative targets from pristine spacecraft materials and ground-based impact tests. Around 2012, an initiative was requested to understand the feasibility of active debris removal (ADR) of larger targets using grappling methods for spent rocket bodies. Using a priori information on selected targets, scaled-down versions of rocket bodies were generated thanks to improvements in 3D printing technology and machining. These targets were studied in the OMC to understand rotation characteristics. These were compared with telescopic data to determine if the tumble and rotation angles would allow ADR. In 2013, the OMC focused on combining spectral measurements with photometric data to characterize GEO orbital debris. Several years later, NASA acquired a Titan III Transtage test article from “The Boneyard” with a high-resemblance to on-orbit Titan III Transtage rocket bodies, allowing physical access to a representative rocket body that suffered fragmentations in GEO. This prompted the creation of 3D models using lidar technology and spectral measurements of the materials. Focused research also transitioned to specific materials (i.e., solar cells) when telescopic surveys requested characterization of specific GEO targets. In the different research products presented, the focus has been to understand the various parameters that influence optical size estimation, including albedo, phase functions, and brightness variations. Work in this area continues with newer sources of data, including DebriSat, a high-fidelity 56-kg spacecraft replica representative of a modern low Earth orbit (LEO) satellite subjected to a laboratory hypervelocity impact test to understand fragmentation events and to support updates to satellite breakup models and size estimation models. Utilizing the vast population of fragments from DebriSat and prior laboratory impact experiments, the ODPO has focused on acquiring bidirectional reflectance distribution function (BRDF) data to characterize targets in the laboratory, thus removing aspect angle dependencies. Additionally, the DebriSat project has provided improved processes for measuring size via image acquisition, such that a true fragment size can be directly compared to the derived size using the OSEM. The team continues to assess BRDFs and use spectral measurement data to investigate the parameters used in the OSEM, specifically magnitudes, albedo, and phase functions.

Heather Cowardin↗

H 1504 + 65 - An extraordinarily hot compact star devoid of hydrogen and helium

The optical identification of the bright soft X-ray source H 1504 + 65, originally discovered by the HEAO I A-2 low energy detectors, is reported. The optical counterpart exhibits a steep, virtually featureless continuum from optical wavelengths through the ultraviolet. The spectrum is remarkably featureless except for a broad O VI adsorption feature at 3494.7 A and C IV absorption at 3934 A and emission at 4658 A. The soft X-ray data, which are not consistent with any published models for degenerate stars having predominantly H or He compositions, suggest that H 1504 + 65 is a metal-rich, near-degenerate object of very high temperature. Qualitative considerations indicate that it is definitely hotter than PG 1159 - 035 and similar objects. A temperature of roughly 160,000 K is suggested.

Nousek, J. A.↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

High-speed fiber-coupled terahertz time-domain spectroscopy system using a bias-free plasmonic source

We demonstrate a high-speed fiber-coupled terahertz time-domain spectroscopy (THz-TDS) system using a bias-free plasmonic terahertz source. The system is powered by a compact, low-power femtosecond fiber laser oscillator that drives a dual-branch fiber amplifier to pump and probe a plasmonic terahertz source and detector, respectively. A polarization-maintaining, fiber-coupled optical delay line is employed to precisely control the temporal offset between the pump and probe beams through a compact, robust platform. Operating in the self-similar amplification regime, the fiber amplifiers are engineered to mitigate nonlinear pulse distortion and dispersion while delivering robust, high-energy pulses at a 1560-nm wavelength, with an output power exceeding 326 mW. In reflection mode, the THz-TDS system achieves a peak dynamic range of 81 dB and a bandwidth greater than 3.5 THz at a scan rate of 3.75 Hz. The utility of the system for rapid sensing is further demonstrated by quantifying the porosity and density of pharmaceutical tablets through measurements of their physical thickness and effective refractive index.

Jiang, Xinghe [University of California, Los Angel↗

Precision optical angular position marker system for rotating machinery

An optical system is described which generates one or more markers of the angular shaft position of rotating machinery. The system consists of a light source, an optical cable, a machinery mounted lens assembly, a light detector, and a signal conditioner. Light reflected by targets on the rotor is converted to a digital output signal. The system is highly immune to extreme environments of vibration and temperature and achieved a 0.002 percent precision under operational test conditions.

Barranger, J. P.↗

A New Method for Reduction of Photomultiplier Signal-Induced Noise

For lidar measurements of ozone, photomultiplier tube (PMT) detector signal-induced noise represents a fundamental problem that complicates the extraction of information from lidar data. A new method is developed to significantly reduce signal-induced noise in lidar receiver PMT detectors. The electron optics of the lidar photomultiplier detector is modified to filter the source of signal-induced noise. A mesh electrode external to the PMT is utilized to control photoemission and disorient electron trajectories from the photocathode to the first dynode. Experiments were taken both with simulated and actual lidar return signals at Langley Research Center. Results show at least 40 percent more accurate ozone number density values with a mesh voltage of 60 V applied than with no voltage applied.

Koble, Andrea↗

Algorithm for astronomical, extended source, signal-to-noise radio calculations

An algorithm was developed to simulate the expected signal-to-noise ratio as a function of observation time in the charge coupled device detector plane of an optical telescope located outside the Earth's atmosphere for an extended, uniform astronomical source embedded in a uniform cosmic background. By choosing the appropriate input values, the expected extended source signal-to-noise ratios can be computed for the Hubble Space Telescope using the Wide Field/Planetary Camera science instrument.

Jayroe, R. R.↗

Advanced Optical Diagnostics for Ice Crystal Cloud Measurements in the NASA Glenn Propulsion Systems Laboratory

A light extinction tomography technique has been developed to monitor ice water clouds upstream of a direct connected engine in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center (GRC). The system consists of 60 laser diodes with sheet generating optics and 120 detectors mounted around a 36-inch diameter ring. The sources are pulsed sequentially while the detectors acquire line-of-sight extinction data for each laser pulse. Using computed tomography algorithms, the extinction data are analyzed to produce a plot of the relative water content in the measurement plane. To target the low-spatial-frequency nature of ice water clouds, unique tomography algorithms were developed using filtered back-projection methods and direct inversion methods that use Gaussian basis functions. With the availability of a priori knowledge of the mean droplet size and the total water content at some point in the measurement plane, the tomography system can provide near real-time in-situ quantitative full-field total water content data at a measurement plane approximately 5 feet upstream of the engine inlet. Results from ice crystal clouds in the PSL are presented. In addition to the optical tomography technique, laser sheet imaging has also been applied in the PSL to provide planar ice cloud uniformity and relative water content data during facility calibration before the tomography system was available and also as validation data for the tomography system. A comparison between the laser sheet system and light extinction tomography resulting data are also presented. Very good agreement of imaged intensity and water content is demonstrated for both techniques. Also, comparative studies between the two techniques show excellent agreement in calculation of bulk total water content averaged over the center of the pipe.

Bencic, Timothy J.↗

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

Focal-Plane-Array Optical Proximity Sensors

Objects detected at beam axis intersections. Group of light sources or detectors is mounted in box at focal plane of lens. Box can therefore illuminate or view several axes, each corresponding to source or detector of group. Proximity sensing system developed to trigger braking system of automatically controlled car.

Johnston, A. R.↗

Measuring Local Turbulence Along the Optical Path: Multi-Beam Optical Seeing Sensor

Deflection of light along the optical path is a major source of image degradation for ground-based telescopes. Methods have been developed to measure upper atmospheric seeing based on models of the turbulence in the atmosphere, but due to boundary conditions, transmission within telescope enclosures is more complex. The Multi-beam Optical Seeing Sensor (MOSS) directly measures the component of the image quality degradation from inhomogeneity of the index of refraction within the telescope dome. MOSS outputs four near-parallel beams of light that travel along the optical path and are imaged by the telescope’s detector, landing like starlight on the telescope’s focal plane. By using a strobed light source, we can ‘freeze’ the instantaneous index variations transverse to the optical path. This system captures both ‘dome’ and ‘mirror’ seeing. Through plotting the standard deviation of differential motion between pairs of beams, MOSS enables characterization of the length scale of turbulence within the dome. The temporal coherence of temperature gradients can be probed with different pulse lengths, and the spatial coherence by comparing pairs at different separations across the aperture of the telescope. Optical path turbulence measurements, alongside other telemetry metrics, will guide thermal and airflow management to optimize image quality. A MOSS prototype was installed in the 1.2[Formula: see text]m Auxiliary Telescope (AuxTel) at the Vera C. Rubin Observatory in Chile, and preliminary data constrain the optical path turbulence with a lower bound of 1.4 arcsec. The optical path turbulence varied throughout the night of observing.

Astronomical seeing↗

Design and construction of a wide angle diffuse source

A Multispectral Scanner (MSS) has been under development for some time and is now undergoing tests for final calibration. It has four bands, each containing six channels. Thus it has 24 detectors which receive radiation by fiber optics. It is shown that a spherical integrator makes a satisfactory extended source for the calibration of the scanner.

Mohr, E. I.↗

Investigation of light scattering as a technique for detecting discrete soot particles in a luminous flame

The practicability of using a classical light-scattering technique, involving comparison of angular scattering intensity patterns with theoretically determined Mie and Rayleight patterns, to detect discrete soot particles (diameter less than 50 nm) in premixed propane/air and propane/oxygen-helium flames is considered. The experimental apparatus employed in this investigation included a laser light source, a flat-flame burner, specially coated optics, a cooled photomultiplier detector, and a lock-in voltmeter readout. Although large, agglomerated soot particles were detected and sized, it was not possible to detect small, discrete particles. The limiting factor appears to be background scattering by the system's optics.

Source record↗

Optical multiple sample vacuum integrating sphere

An integrating sphere comprised of a uniform difusely reflecting spherical cavity, having mutually transverse input and output ports, and a linear sample transport mechanism is described. The sample transport mechanism is secured so that the multiple samples can be brought into registration with the input port, one at a time, without having to open or disassemble the apparatus when a change of sample is desired. A vacuum tight seal is provided between the cavity and the transport mechanism. This maintains the integrity of a vacuum generated with the sphere when attached to the source of optical energy. The device is utilized to test emissive characteristics such as the relative fluorescence quantum efficiency of a dye sample placed in the path of a monochromatic optical energy source coupled to the input port while having a light detector coupled to the output port.

Butner, C. L.↗

Characterization of AlMn TES Impedance, Noise, and Optical Efficiency in the First 150 mm Multichroic Array for Advanced ACTPol

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope features large arrays of multichroic pixels consisting of two orthogonal-polarization pairs of superconducting bolometers at two observing frequency bands. We present measurements of the detector properties and noise data in a subset of a fielded multichroic array of AlMn transition-edge sensor (TES) detectors. In this array, the distribution of critical temperature T(sub c) across detectors appears uniform at the percent level. The measured noise-equivalent power (NEP) distributions over approximately 1200 detectors are consistent with expectations. We find median NEPs of 4.0×10(exp −17) W/ √ Hz for low-band detectors and 6.2×10(exp −17) W/ √ Hz for high-band detectors under covered-window telescope test conditions with optical loading comparable to observing with precipitable water vapor approximately 0.5 mm. Lastly, we show the estimated detector optical efficiency, and demonstrate the ability to perform optical characterization over hundreds of detectors at once using a cryogenic blackbody source.

Crowley, Kevin T.↗

Discovery and optical identification of 2S0921-630

The discovery of a faint X-ray source at approximately 282 deg galactic longitude, -9 deg galactic latitude with the rotation modulation collimator X-ray detectors aboard SAS 3 is reported. The source is designated 2S 0921-630 and is tentatively identified, on the basis of an optical search, with a 17th magnitude star exhibiting the He II line at 4686 A and H-beta in emission. The optical spectrum of this star is shown to be similar to those of the optical counterparts of Sco X-1 and other such galactic X-ray sources. It is suggested that 2S 0921-630 may belong to the class of low-luminosity galactic X-ray binaries.

Li, F. K.↗