Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Holographic, particle imaging and data reduction at Spectron Development Laboratores

Spectron has been deeply involved in the development and use of a wide variety of particle and flow diagnostic, electro optical instruments. Holography and imaging systems have played an important role in this work, but the extraction of data from images and holograms have always presented a limit to their use. Systems and techniques were devised to speed up and automate the extraction of data from holographic and conventional interferograms, particle images and holograms, and other types of optical flow visualization techniques. An IBM/AI based image analyzer was developed that is capable of automatically analyzing many useful image types including interferograms. A key feature of this system is the low total cost of the required hardware. In the particle field work, a commercial diffraction field analyzer was adopted to the image reconstructed from a hologram. This could expand the use of holography in particle diagnostics greatly.

Trolinger, James D.↗

A hybrid approach to estimate the complex motions of clouds in sky images

Tracking the motion of clouds is essential to forecasting the weather and to predicting the short-term solar energy generation. Existing techniques mainly fall into two categories: variational optical flow, and block matching. In this article, we summarize recent advances in estimating cloud motion using ground-based sky imagers and quantitatively evaluate state-of-the-art approaches. Then we propose a hybrid tracking framework to incorporate the strength of both block matching and optical flow models. To validate the accuracy of the proposed approach, we introduce a series of synthetic images to simulate the cloud movement and deformation, and thereafter comprehensively compare our hybrid approach with several representative tracking algorithms over both simulated and real images collected from various sites/imagers. The results show that our hybrid approach outperforms state-of-the-art models by reducing at least 30% motion estimation errors compared with the ground-truth motions in most of simulated image sequences. Furthermore, our hybrid model demonstrates its superior efficiency in several real cloud image datasets by lowering at least 15% Mean Absolute Error (MAE) between predicted images and ground-truth images.

54 ENVIRONMENTAL SCIENCES↗

OPTICAL MASS FLOW DIAGNOSTICS IN HERBIG AE/BE STARS

We examine a broad range of mass flow diagnostics in a large sample of Herbig Ae/Be stars (HAEBES) using high resolution optical spectra. The Hβ and He i 5876 Å lines show the highest incidence of P Cygni (30%) and inverse P Cygni (14%) morphologies, respectively. The Fe ii 4924 Å line also shows a large incidence of P Cygni profiles (11%). We find support for many of the conclusions reached in a study based on the analysis of the He i λ10830 line in a large sample of HAEBES. Namely, HAEBES exhibit smaller fractions of both blueshifted absorption (i.e., mass outflow) and redshifted absorption (i.e., mass infall or accretion) than their lower mass cousins, the classical T Tauri stars (CTTSs). In particular, the optical data supports the conclusion that HAEBES displaying redshifted absorption, in general, show maximum redshifted absorption velocities that are smaller fractions of their stellar escape velocities than is found for CTTSs. This suggests that HAEBE accretion flows are originating deeper in the gravitational potentials of their stars than in CTTS systems. In addition, we find a lack of inner disk wind signatures in the blueshifted absorption objects; only stellar wind signatures are clearly observed. These findings, along with the lack of detected magnetic fields around HAEBES, support the idea that large magnetospheres are not prevalent around HAEBES and that accretion flows are instead mediated by significantly smaller magnetospheres with relatively smaller truncation radii (e.g., 1–2 R{sub *}). Redshifted absorption is much more common around Herbig Ae stars than Be stars, suggesting that Herbig Be stars may accrete via a boundary layer rather than along magnetic field lines.

79 ASTRONOMY AND ASTROPHYSICS↗

The X-ray spectra of cluster cooling flows. I - Optically thin models

Calculations are carried out of optically thin X-ray spectra for a set of theoretical cluster cooling flow models including homogeneous models and flows with strong gas loss. Integrated X-ray properties for the models are presented, together with surface brightness profiles, aperture luminosities, and line profiles for a representative set of X-ray lines. It is found that models with gas loss have lower total X-ray luminosities than homogeneous models by a factor of 1.35 or less.

Wise, Michael W.↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Results from an initial series of experiments and analyses performed at the Positron Imaging Centre (PIC) located at the University of Birmingham, UK, will be presented. Discussion will also cover preliminary, on-going, activities associated with assessing the utility of PET technology in zero-gravity propellant gauging, ionization efficiency characterization in electric propulsion devices, and broader industrial applications.

PET↗

Optically Inaccessible Flow Visualization using Positron Emission Tomography

Flow visualization is a powerful tool for characterizing fluid dynamics within engineering systems that utilize fluid working media. Recent advances in Positron Emission Tomography (PET) have enhanced its ability to extend beyond the medical field, and offer an alternate vantage point in visualizing optically inaccessible fluid distributions and flow fields within the aerospace field. In light of this prospect an investigation has ensued to parametrically bound the flows that can be sufficiently resolved using current PET technology. Preliminary results from on going simulations and analyses will be presented.

Bruggemann, Jeremy↗

Gait Training Improves Performance in Healthy Adults Exposed to Novel Discordant Conditions

After they return to Earth, astronauts experience sensorimotor disturbances that disrupt their ability to walk. We have previously shown that training with a variety of sensorimotor adaptive challenges enhances the capability of adapting to novel sensorimotor conditions. We are currently developing a sensorimotor adaptability (SA) training program designed to facilitate recovery of function after gravitational transitions. The purpose of this study was to determine whether trained subjects could transfer learned skills from one discordant visuo-proprioceptive environment to another. During three sessions, subjects walked at 2.5 km/h on a treadmill mounted on a motion base platform. Ten subjects trained with a combination of lateral treadmill translation and superimposed sinusoidal lateral optic flow that was presented on a large screen positioned in front of them. Ten controls completed the same training schedule while viewing only the forward optic flow with no visual or physical oscillation. Twenty minutes after the final training session, all subjects completed a 2-minute trial with a novel combination of visual and treadmill roll perturbations not previously experienced during the training (Transfer Test). Compared to the untrained group, participants who received SA training showed faster reaction times and, based on a composite score derived from stride frequency, heart rate, and reaction time, an overall enhanced performance. Our results showed that an SA training program can improve overall walking performance when subjects are exposed to novel incongruent sensory environments. This training has application for both enhancing adaptive responses in astronauts and reducing fall and injury risk in the elderly.

Batson, Crystal D.↗

Optical Flow-Field Techniques Used for Measurements in High-Speed Centrifugal Compressors

The overall performance of a centrifugal compressor depends on the performance of the impeller and diffuser as well as on the interactions occurring between these components. Accurate measurements of the flow fields in each component are needed to develop computational models that can be used in compressor design codes. These measurements must be made simultaneously over an area that covers both components so that researchers can understand the interactions occurring between the two components. Optical measurement techniques are being used at the NASA Lewis Research Center to measure the velocity fields present in both the impeller and diffuser of a 4:1 pressure ratio centrifugal compressor operating at several conditions ranging from design flow to surge. Laser Doppler Velocimetry (LDV) was used to measure the intrablade flows present in the impeller, and the results were compared with analyses obtained from two three-dimensional viscous codes. The development of a region of low throughflow velocity fluid within this high-speed impeller was examined and compared with a similar region first observed in a large low-speed centrifugal impeller at Lewis. Particle Image Velocimetry (PIV) is a relatively new technique that has been applied to measuring the diffuser flow fields. PIV can collect data rapidly in the diffuser while avoiding the light-reflection problems that are often encountered when LDV is used. The Particle Image Velocimeter employs a sheet of pulsed laser light that is introduced into the diffuser in a quasi-radial direction through an optical probe inserted near the diffuser discharge. The light sheet is positioned such that its centerline is parallel to the hub and shroud surfaces and such that it is parallel to the diffuser vane, thereby avoiding reflections from the solid surfaces. Seed particles small enough to follow the diffuser flow are introduced into the compressor at an upstream location. A high-speed charge-coupled discharge (CCD) camera is synchronized to the laser pulse rate; this allows it to capture images of seed particle position that are separated by a small increment in time. A crosscorrelation of a particle's position in two consecutive images provides an estimate of flow velocity and direction. Multiple image pairs obtained in rapid succession at a particular flow condition provide enough measurements for statistical significance. PIV provides simultaneous velocity measurements over the entire plane that is illuminated by the light sheet instead of at a single point, as is the case when LDV is used. PIV has a further advantage in that the laser light pulse can be triggered by an external source such as a high-response pressure transducer. This feature will allow PIV to synchronize flow imaging to physical phenomena such as rotating stall or stall precursor waves. We hope that this technique can be used to obtain images of the flow field during and just prior to stall.

Skoch, Gary J.↗

Triton: Igiugig Fish Video Analysis (Project Report)

This document summarizes the analysis of video data collected around the Ocean Renewable Power Company’s RivGen® device in the Kvichak River during July and August 2015. Human (manual) analysis of the data was undertaken and used to develop automated algorithms to detect fish in the frames and describe interaction behavior. In addition, a web application, EyeSea, was developed to combine manual and automated processing, so that ultimately the automated algorithms could be used to identify where human analysis was needed (i.e., when fish are present in video frames). The aim of the project was to develop algorithms that could identify video frames with fish present that could then be used to enable faster manual analysis. However, the project has also identified recommendations for future data collection, and research that could help analysis and interpretation. The manual analysis started to look at all data from the start of the deployment; this was to ensure rare events were seen, and initially focused on night-time data when more fish were present. This process highlighted the amount of time taken to identify fish, and ultimately only 42.33 hours of video were reviewed due to the time-consuming analysis. The data were classified as ‘Fish’, when the reviewer was confident it was a fish, and ‘Maybe’ fish, when it was difficult to distinguish. This was based on the movement, shape and color characteristics. ‘Fish’ were further classified as ‘adult’, ‘juvenile’, or ‘unidentifiable’. Behavioral attributes were noted, which were broadly divided into passive and avoidance activities. In over 42 hours data, there were only 20 potential contact interactions, of which 3 were ‘Maybe’ classifications, 12 were juveniles and 5 were adults; on only one occasion was an actual contact confirmed, and this was an adult fish with the camera, not the turbine itself. This also highlights the difficulties associated with confirming a strike or collision event as occurring or being a near-miss. More interactions were detected at night; this was probably biased by nighttime artificial light use, which may have attracted fish, but also could have increased detection probability as the light is reflected from the fish itself. For the algorithm development, background subtraction, optical flow, and deep learning techniques were considered. The deep learning approach was determined as needing too much training data for this application, and therefore was not continued. The optical flow analysis was considered promising, but did not give immediate results, so would need further investigation. Therefore, background subtraction was the main focus. Three methods of background subtraction were tried: Robust Principal Components Analysis (RPCA), Gaussian Mixture Model (GMM) and Video Background Extraction(ViBE). A classification technique was then applied to the foreground images to determine fish presence. Using this combination, it was found that fish could be accurately detected when occupying more pixels (>200 pixels, 98.2% correct; 100-200 pixels, 99.6% correct; 5-100 pixels, 85.4% correct; 2-5 pixels, 66.3% correct). In parallel, EyeSea was developed to convert the video data to a usable form and to enable manual and automated analysis of the data that would have a standardized output. Recommendations for further research, and standardized methods for data collection are given.

13 HYDRO ENERGY↗

Poster - 51: A tumor motion-compensating system with tracking and prediction – a proof-of-concept study

Purpose: This work reports on the development of a mechanical slider system for the counter-steering of tumor motion in adaptive Radiation Therapy (RT). The tumor motion was tracked using a weighted optical flow algorithm and its position is being predicted with a neural network (NN). Methods: The components of the proposed mechanical counter-steering system includes: (1) an actuator which provides the tumor motion, (2) the motion detection using an optical flow algorithm, (3) motion prediction using a neural network, (4) a control module and (5) a mechanical slider to counter-steer the anticipated motion of the tumor phantom. An asymmetrical cosine function and five patient traces (P1–P5) were used to evaluate the tracking of a 3D printed lung tumor. In the proposed mechanical counter-steering system, both actuator (Zaber NA14D60) and slider (Zaber A-BLQ0070-E01) were programed to move independently with LabVIEW and their positions were recorded by 2 potentiometers (ETI LCP12S-25). The accuracy of this counter-steering system is given by the difference between the two potentiometers. Results: The inherent accuracy of the system, measured using the cosine function, is −0.15 ± 0.06 mm. While the errors when tracking and prediction were included, is (0.04 ± 0.71) mm. Conclusion: A prototype tumor motion counter-steering system with tracking and prediction was implemented. The inherent errors are small in comparison to the tracking and prediction errors, which in turn are small in comparison to the magnitude of tumor motion. The results show that this system is suited for evaluating RT tracking and prediction.

60 APPLIED LIFE SCIENCES↗

SU-E-J-58: Comparison of Conformal Tracking Methods Using Initial, Adaptive and Preceding Image Frames for Image Registration

Purpose: Accounting for tumor motion during radiation therapy is important to ensure that the tumor receives the prescribed dose. Increasing the field size to account for this motion exposes the surrounding healthy tissues to unnecessary radiation. In contrast to using motion-encompassing techniques to treat moving tumors, conformal radiation therapy (RT) uses a smaller field to track the tumor and adapts the beam aperture according to the motion detected. This work investigates and compares the performance of three markerless, EPID based, optical flow methods to track tumor motion with conformal RT. Methods: Three techniques were used to track the motions of a 3D printed lung tumor programmed to move according to the tumor of seven lung cancer patients. These techniques utilized a multi-resolution optical flow algorithm as the core computation for image registration. The first method (DIR) registers the incoming images with an initial reference frame, while the second method (RFSF) uses an adaptive reference frame and the third method (CU) uses preceding image frames for registration. The patient traces and errors were evaluated for the seven patients. Results: The average position errors for all patient traces were 0.12 ± 0.33 mm, −0.05 ± 0.04 mm and −0.28 ± 0.44 mm for CU, DIR and RFSF method respectively. The position errors distributed within 1 standard deviation are 0.74 mm, 0.37 mm and 0.96 mm respectively. The CU and RFSF algorithms are sensitive to the characteristics of the patient trace and produce a wider distribution of errors amongst patients. Although the mean error for the DIR method is negatively biased (−0.05 mm) for all patients, it has the narrowest distribution of position error, which can be corrected using an offset calibration. Conclusion: Three techniques of image registration and position update were studied. Using direct comparison with an initial frame yields the best performance. The authors would like to thank Dr.YeLin Suh for making the Cyberknife dataset available to us. Scholarship funding from the Natural Sciences and Engineering Research Council of Canada (NSERC) and CancerCare Manitoba Foundation is acknowledged.

60 APPLIED LIFE SCIENCES↗

Tracking Dendritic Growth in Hydrogen-Based Hematite Reduction via Computer Vision

The reduction of hematite to metallic iron using hydrogen (H2) as a reducing agent presents a promising pathway for decarbonizing steel production. In this study, we employ a combination of in situ confocal scanning laser microscopy (CSLM) and advanced computer vision techniques to quantitatively analyze dendritic growth of ferrite during H2-based reduction of iron oxide at high temperatures. A workflow integrating Watershed Image Segmentation (WIS) and Lucas-Kanade Optical Flow (LKOF) is developed to extract both global and local kinetic information from time-resolved micrograph sequences. H2 reduction experiments conducted at 1400 degrees C and 1500 degrees C demonstrate a clear correlation between temperature and reduction rate, as evidenced by accuracy of fitted Johnson-Mehl-Avrami-Kolmogorov (JMAK) parameters. Optical flow analysis further elucidates the anisotropic and branched nature of dendritic growth, providing spatially resolved velocity fields that correlate well with global transformation kinetics. The proposed methodology demonstrates strong agreement with experimental measurements and literature values, offering a robust framework for automated image-based analysis to study kinetics through microstructural evolution in the reduction of iron ore, and likely other reaction-diffusion phenomena.

08 HYDROGEN↗

Inertial navigation sensor integrated obstacle detection system

A system that incorporates inertial sensor information into optical flow computations to detect obstacles and to provide alternative navigational paths free from obstacles. The system is a maximally passive obstacle detection system that makes selective use of an active sensor. The active detection typically utilizes a laser. Passive sensor suite includes binocular stereo, motion stereo and variable fields-of-view. Optical flow computations involve extraction, derotation and matching of interest points from sequential frames of imagery, for range interpolation of the sensed scene, which in turn provides obstacle information for purposes of safe navigation.

Bhanu, Bir↗

Detection of obstacles on runway using Ego-Motion compensation and tracking of significant features

This report describes a method for obstacle detection on a runway for autonomous navigation and landing of an aircraft. Detection is done in the presence of extraneous features such as tiremarks. Suitable features are extracted from the image and warping using approximately known camera and plane parameters is performed in order to compensate ego-motion as far as possible. Residual disparity after warping is estimated using an optical flow algorithm. Features are tracked from frame to frame so as to obtain more reliable estimates of their motion. Corrections are made to motion parameters with the residual disparities using a robust method, and features having large residual disparities are signaled as obstacles. Sensitivity analysis of the procedure is also studied. Nelson's optical flow constraint is proposed to separate moving obstacles from stationary ones. A Bayesian framework is used at every stage so that the confidence in the estimates can be determined.

Kasturi, Rangachar↗

Estimating nonrigid motion from inconsistent intensity with robust shape features

Purpose: To develop a nonrigid motion estimation method that is robust to heterogeneous intensity inconsistencies amongst the image pairs or image sequence. Methods: Intensity and contrast variations, as in dynamic contrast enhanced magnetic resonance imaging, present a considerable challenge to registration methods based on general discrepancy metrics. In this study, the authors propose and validate a novel method that is robust to such variations by utilizing shape features. The geometry of interest (GOI) is represented with a flexible zero level set, segmented via well-behaved regularized optimization. The optimization energy drives the zero level set to high image gradient regions, and regularizes it with area and curvature priors. The resulting shape exhibits high consistency even in the presence of intensity or contrast variations. Subsequently, a multiscale nonrigid registration is performed to seek a regular deformation field that minimizes shape discrepancy in the vicinity of GOIs. Results: To establish the working principle, realistic 2D and 3D images were subject to simulated nonrigid motion and synthetic intensity variations, so as to enable quantitative evaluation of registration performance. The proposed method was benchmarked against three alternative registration approaches, specifically, optical flow, B-spline based mutual information, and multimodality demons. When intensity consistency was satisfied, all methods had comparable registration accuracy for the GOIs. When intensities among registration pairs were inconsistent, however, the proposed method yielded pronounced improvement in registration accuracy, with an approximate fivefold reduction in mean absolute error (MAE = 2.25 mm, SD = 0.98 mm), compared to optical flow (MAE = 9.23 mm, SD = 5.36 mm), B-spline based mutual information (MAE = 9.57 mm, SD = 8.74 mm) and mutimodality demons (MAE = 10.07 mm, SD = 4.03 mm). Applying the proposed method on a real MR image sequence also provided qualitatively appealing results, demonstrating good feasibility and applicability of the proposed method. Conclusions: The authors have developed a novel method to estimate the nonrigid motion of GOIs in the presence of spatial intensity and contrast variations, taking advantage of robust shape features. Quantitative analysis and qualitative evaluation demonstrated good promise of the proposed method. Further clinical assessment and validation is being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multirate and event-driven Kalman filters for helicopter flight

A vision-based obstacle detection system that provides information about objects as a function of azimuth and elevation is discussed. The range map is computed using a sequence of images from a passive sensor, and an extended Kalman filter is used to estimate range to obstacles. The magnitude of the optical flow that provides measurements for each Kalman filter varies significantly over the image depending on the helicopter motion and object location. In a standard Kalman filter, the measurement update takes place at fixed intervals. It may be necessary to use a different measurement update rate in different parts of the image in order to maintain the same signal to noise ratio in the optical flow calculations. A range estimation scheme that accepts the measurement only under certain conditions is presented. The estimation results from the standard Kalman filter are compared with results from a multirate Kalman filter and an event-driven Kalman filter for a sequence of helicopter flight images.

Sridhar, Banavar↗

Performance of 12 DIR algorithms in low-contrast regions for mass and density conserving deformation

Purpose: Deformable image registration (DIR) has become a key tool for adaptive radiotherapy to account for inter- and intrafraction organ deformation. Of contemporary interest, the application to deformable dose accumulation requires accurate deformation even in low contrast regions where dose gradients may exist within near-uniform tissues. One expects high-contrast features to generally be deformed more accurately by DIR algorithms. The authors systematically assess the accuracy of 12 DIR algorithms and quantitatively examine, in particular, low-contrast regions, where accuracy has not previously been established.Methods: This work investigates DIR algorithms in three dimensions using deformable gel (DEFGEL) [U. J. Yeo, M. L. Taylor, L. Dunn, R. L. Smith, T. Kron, and R. D. Franich, “A novel methodology for 3D deformable dosimetry,” Med. Phys. 39, 2203–2213 (2012)], for application to mass- and density-conserving deformations. CT images of DEFGEL phantoms with 16 fiducial markers (FMs) implanted were acquired in deformed and undeformed states for three different representative deformation geometries. Nonrigid image registration was performed using 12 common algorithms in the public domain. The optimum parameter setup was identified for each algorithm and each was tested for deformation accuracy in three scenarios: (I) original images of the DEFGEL with 16 FMs; (II) images with eight of the FMs mathematically erased; and (III) images with all FMs mathematically erased. The deformation vector fields obtained for scenarios II and III were then applied to the original images containing all 16 FMs. The locations of the FMs estimated by the algorithms were compared to actual locations determined by CT imaging. The accuracy of the algorithms was assessed by evaluation of three-dimensional vectors between true marker locations and predicted marker locations.Results: The mean magnitude of 16 error vectors per sample ranged from 0.3 to 3.7, 1.0 to 6.3, and 1.3 to 7.5 mm across algorithms for scenarios I to III, respectively. The greatest accuracy was exhibited by the original Horn and Schunck optical flow algorithm. In this case, for scenario III (erased FMs not contributing to driving the DIR calculation), the mean error was half that of the modified demons algorithm (which exhibited the greatest error), across all deformations. Some algorithms failed to reproduce the geometry at all, while others accurately deformed high contrast features but not low-contrast regions—indicating poor interpolation between landmarks.Conclusions: The accuracy of DIR algorithms was quantitatively evaluated using a tissue equivalent, mass, and density conserving DEFGEL phantom. For the model studied, optical flow algorithms performed better than demons algorithms, with the original Horn and Schunck performing best. The degree of error is influenced more by the magnitude of displacement than the geometric complexity of the deformation. As might be expected, deformation is estimated less accurately for low-contrast regions than for high-contrast features, and the method presented here allows quantitative analysis of the differences. The evaluation of registration accuracy through observation of the same high contrast features that drive the DIR calculation is shown to be circular and hence misleading.

61 RADIATION PROTECTION AND DOSIMETRY↗