Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Offshore Wind Farm Turbine and Energy Storage Optimization

Abstract This paper evaluates the technical and economic feasibility of repurposing decommissioned offshore oil and gas platforms as electrical substations for offshore wind projects in the U.S. Gulf of America, a region characterized by relatively low and highly variable wind speeds, extensive legacy offshore infrastructure, and exposure to merchant electricity markets. A unified techno-economic framework is developed using the Repurposing Offshore Infrastructure for Continued Energy (ROICE) Economic Model (REM) to integrate Gulfspecific wind resource assessment, commercial wind turbine performance, offshore infrastructure cost modeling, and wholesale electricity market exposure. Gulf wind speed data are vertically extrapolated to turbine hub height and combined with manufacturer power curves to compute annual energy production and capacity factors across a broad portfolio of commercial turbines, enabling identification of turbine designs best suited for low-wind offshore environments. Hourly electricity price data from the Midcontinent Independent System Operator (MISO) day-ahead market are incorporated to characterize revenue potential, price volatility, and the temporal alignment between wind generation and market conditions. In addition, a conceptual framework for offshore battery energy storage system (BESS) integration is developed to support future investigation of market-responsive energy shifting at repurposed platforms. Results from the turbine evaluation demonstrate that machines with lower cut-in wind speeds and earlier ‘rated-power’ characteristics significantly outperform larger, industry-standard offshore turbines for the same net power under Gulf wind conditions, underscoring the need for region-specific technology selection. Market analysis further reveals substantial price variability and limited intrinsic alignment between wind production and high-price periods, motivating consideration of operational flexibility mechanisms. While storage optimization is not implemented in this study, the REM framework establishes a transparent and replicable foundation for co-evaluating turbine selection, infrastructure constraints, and market exposure, providing a practical pathway for assessing the potential role of repurposed offshore platforms in enabling economically viable offshore wind development in the Gulf of America.

02 PETROLEUM↗

Raptor

Raptor is an efficient Python-based tool for predicting the formation and morphology of stochastic lack of fusion defects in metal AM processes. A major obstacle for the qualification and certification of additively manufactured parts in critical applications continues to be performance variability caused in part by porosity-related defects. High-fidelity process models that could predict these defect features are currently too computationally expensive for component-level analysis. To address this, Raptor employs a high-performance geometric method to model the dynamic melt pool rather than relying on computationally intensive thermal fluid dynamics. This allows Raptor to rapidly identify regions of unmelted material that correspond to lack of fusion pores. The efficiency of this approach significantly reduces the time and resources needed for generating 3D defect predictions, which enables users to conduct large-scale parameter studies and evaluate how process variations affect part quality. The framework offers operational flexibility; users can execute simulations through a simple command line interface or integrate core functions as a library within larger computational workflows. Simulation outputs include 3D porosity maps for visualization and tools for quantitative morphological analysis. These results are suitable for direct comparison with experimental characterization data from methods such as X-ray computed tomography and can be used for statistical process optimization.

Subraveti, Vamsi [Vanderbilt Univ., Nashville, TN ↗

Membrane-based carbon capture process optimization using CFD modeling

Carbon capture is a promising option to mitigate CO2 emissions from existing coal-fired power plants, cement and steel industries, and petrochemical complexes. Among the available technologies, membrane-based carbon capture presents the lowest energy consumption, operating costs, and carbon footprint. In addition, membrane processes have important operational flexibility and response times. On the other hand, the major challenges to widespread application of this technology are related to reducing capital costs and improving membrane stability and durability. To upscale the technology into stacked flat sheet configurations, high fidelity computational fluid dynamics (CFD) that describes the separation process accurately are required. High fidelity simulations have been shown to be effective in studying the complex transport phenomena in membrane systems. In addition, obtaining high CO2 recovery percentages and product purity requires a multi-stage membrane process, where the optimal network configuration of the membrane modules must be studied in a systematic way. In order to address the design problem at process scale, we formulate a superstructure for the membrane-based carbon capture, including up to three separation stages. In the formulation of the optimization problem, we include reduced models, based on rigorous CFD simulations of the membrane modules. Numerical results indicate that the optimal design includes three membrane stages, and the capture cost is 45.4 $/t-CO2.

Pedrozo, Hector A.↗

Role of Inverter-Based Resources (IBRs) in Energizing Remote Generating Stations

The increasing integration of Inverter-Based Resources (IBRs) into the system has brought significant focus on their role in blackstart and restoration procedures. Their advantageous features, such as low startup power requirements, operational flexibility across a wide range of power factors, rapid controllability, and the ability to energize a network at lower voltage levels necessitate a reassessment of existing restoration protocols. This paper seeks to showcase how IBRs can utilize their grid-forming capabilities to provide power to a remote generating station through detailed EMT simulation studies using data collected from an existing portion of a network.

blackstart procedure↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies: Preprint

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Considerations for Thermal Annealing of Zr-Alloy Cladding During Dry Storage

In January 2025, the U.S. Department of Energy (DOE) sponsored a technical workshop with fuel vendors that provided a forum for increased collaboration on backend fuel cycle research. The workshop reviewed observations of thermal annealing of irradiated zirconium alloys in simulated dry storage conditions and discussed implications to the industry’s interest in reducing wet storage to optimize operational flexibility and the expected trend of increasing discharge burnup (and decay heats), which could lead to an increase in dry storage temperatures. One approach to accommodate increased decay heats in dry storage is to increase the regulatory temperature limit during dry storage, which is now 400°C. However, this could lead to thermal annealing of the cladding, which will tend to increase creep rates, creep strains, and ductility while decreasing yield strength. These considerations are compounded by bonding between the pellet and cladding at high burnup, which results in the pellet carrying more load during fuel rod deformations, especially in bending, which is the dominant deformation phenomenon in canister drop analyses. Because the U.S. Nuclear Regulatory Commission (NRC) recommends yield strength as a primary failure criterion for accident analyses in storage and transportation, particularly for canister drop scenarios, the purpose of the workshop was to develop options for alternative failure criterion that could replace yield strength in canister drop analyses. Topics discussed were (1) the regulatory framework, (2) the effect of thermal annealing on microhardness and tensile properties of cladding materials, (3) the effect of thermal annealing on fuel rod failure during bending, bending fatigue, and pinch loading, and (4) an alternative failure criterion for canister drop analyses. This paper provides a summary of the key discussions and outcomes of the workshop

Cantonwine, Paul [ORNL] (ORCID:0009000522247033)↗

Assessment of CTF for Steady-state and Transient Post-CHF Conditions in Support of Time-at-Temperature Modeling Applications

The US nuclear industry is exploring options to improve operational economics and uprate the current fleet of light-water reactors by investigating transitioning to cladding performance–based safety criteria as opposed to the current limit, which requires complete avoidance of critical heat flux (CHF)/dryout. Past experience has shown that not all events leading to a dryout are severe enough to cause fuel performance degradation. Allowing temporary dryout of the fuel—that is, using a time-at-temperature (TaT) strategy—could allow for economic improvements via large power uprates and enhanced operational flexibility for current plants without compromising fuel integrity. To support this effort, the US Department of Energy is executing a comprehensive program that includes generating cladding material data under TaT conditions, developing new mechanistic models, and demonstrating modeling and simulation capabilities for transients of interest. This paper presents work performed to assess the CTF thermal-hydraulics subchannel code. CTF is a package used in the VERA core simulator, which will ultimately be used for TaT analysis. CTF will provide the thermal-hydraulic boundary conditions that will be needed for fuel performance analysis in the BISON code. Quantifying both the accuracy and uncertainty of post-CHF models will therefore be necessary. This paper outlines the strategy for the assessment of TaT and presents the results of using the steady-state and transient dryout experiments of the Boiling Fine-mesh Bundle Tests for CTF validation. The results show that the current model tends to overpredict steady-state critical power. This behavior translates to the transient tests, in which CTF is unable to capture transient dryout behavior. Some discussion of sensitivity analysis work being performed is provided to indicate which models must be further analyzed to properly model transient dryout and its uncertainty.

Salko Jr, Robert [ORNL] (ORCID:0000000253566679)↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗

Flexible dynamic boundary microgrid operation considering network and load unbalances

Flexible microgrids with dynamic boundaries have recently been introduced in the literature. With the ability to reconfigure the topology of the microgrids dynamically through remotely controlled switches, flexible microgrids with dynamic boundaries can further improve the resiliency and energy efficiency of microgrids with distributed energy resources (DERs). This paper focuses on the optimal operation considering one of the predominant characteristics of microgrids and distribution systems – unbalanced networks and loads. In existing literature, balanced modeling of microgrids is more common due to its attractive simplicity. The three-phase power unbalance has not been considered as a constraint on the generation units in a microgrid. Further, negative sequence constraints have also been neglected. In this article, we propose a set of constraints that is specifically related to the capabilities of inverter interfaced resources to supply unbalanced current/power when the microgrid is islanded from the main distribution grid. We incorporate the new set of constraints into two optimization formulations leveraging two convex relaxations of the three-phase power flow equations: mixed-integer linear programming (MILP) and mixed-integer semidefinite programming (MISDP) that optimize the dispatch of controllable switches and DERs in the microgrid. The algorithms are then extended to networked microgrids with grid-forming sources. We test the algorithms on a realistic community microgrid model in Puerto Rico as well as standardized IEEE distribution test feeders. The testing results demonstrate the performance of the proposed algorithms. The MILP is fast and scalable, and the MISDP enforces the negative sequence voltage constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fitness-for-Service Analysis of Reactor Components under Flexible Load-Following Operating Conditions

Conventional power-generation plants, including nuclear plants, have been traditionally designed to provide a steady baseload energy capacity, optimizing output efficiency while minimizing variable costs. However, the growing adoption of large-scale renewable energy-generation systems, which rely on intermittent sources such as solar and wind, has introduced more variability into the energy supply in interconnected electricity grids. As a result, the next generation of power plants needs to operate in what is known as the load-following mode, requiring flexible adjustments in electricity production to align with the energy demand on the grid. This transition from the steady baseload operation to load-following operating conditions can significantly increase the number of times various plant components are exposed to transient stresses. This increased thermo-mechanical cycling can lead to accelerated material degradation, thereby elevating the risk of premature failure of a component. It becomes imperative to conduct a comprehensive analysis of fatigue, creep-fatigue, and stress corrosion cracking life, to assess the resilience of the various engineering components under these flexible load-following operating conditions. This study aims to develop a comprehensive numerical model of a light-water reactor pressure vessel (RPV) to investigate its degradation under various operating scenarios. This coupled thermo-mechanical finite element analysis evaluated the stress response of the RPV caused by considering fluctuations in thermal and mechanical loads caused by the varying pressure and temperature occurring during the load-following operation. Critical locations on the RPV are subsequently identified based on the stress response. The stress intensity factors for the postulated flaws at those locations are then calculated, followed by an evaluation of the reactor's life in accordance with the ASME Boiler and Pressure Vessel Code Section XI. This comprehensive life assessment covers a number of transients expected during the flexible load-following operation, providing invaluable insights into the RPV's structural integrity. Moreover, the development methodology can be adapted to other reactor components, as well as components of conventional power stations that are affected by varying operating conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Techno-Economic Viability of Flexible Dispatch of Unconventional Geothermal Systems

Flexible geothermal operations could boost project returns through the allocation of improved power purchase agreements and/or exploitation of power price arbitrage opportunities. In this study, we investigated the techno-economic feasibility of variable flow rate control and time-of-day pricing in closed-loop geothermal systems. We considered U-shaped multilateral system configurations and modeled a variety of technical system parameters. These designs were simulated using a slender-body theory (SBT) model for transient heat transfer and fluid flow. This subsurface model was integrated into the flexible geothermal economic model (FGEM) tool to evaluate the overall flexible geothermal system techno-economics. Future hourly ambient temperature conditions were based on the Sup3rCC dataset. Published datasets were used for future hourly wholesale electricity prices. We analyzed four operating strategies: 1) baseload operation, 2) seasonal dispatch (high flow rate during summer and nominal flow rate during the rest of the year), 3) net generation maximization by varying flow rate to maximize net power output, and 4) revenue maximization by varying flow rate to maximize revenue. We ran all four scenarios for a multiloop configuration with 12 lateral passes, 7-km vertical depth and 87-km total drilling length. Furthermore, we assumed a 60 degrees C/km geothermal gradient and ambient temperature and wholesale electricity prices for New Mexico as a typical state location. The nominal flow rate was set to 80 kg/s. When considering drilling costs of $1,000/m and a discount rate of 7%, the generation maximization scenario resulted in the lowest levelized cost of electricity (LCOE) of ~$150/MWh. When considering project return on investment (ROI), defined as lifetime net income divided by upfront capital costs, all flexible operation scenarios performed better than the base case scenario. The highest ROI of 80% was obtained with the revenue maximization scenario. With drilling costs of $200/m and a discount rate of 5%, the generation maximization scenario resulted in LCOE of $49/MWh.

flexible geothermal↗

Opportunities and Challenges for Hydrotreating of Catalytic Fast Pyrolysis Oil to Fuels

Catalytic fast pyrolysis (CFP) provides a versatile platform for producing fuels to combat climate change and meet decarbonizing targets. In this contribution, we will discuss the hydroprocessing of CFP oils to a variety of fuels, including sustainable aviation fuel (SAF), diesel, and marine fuel. Both standalone and co-hydroprocessing with petroleum streams will be covered. Hydrotreating CFP oil at temperatures around 400 Degrees Celsius can produce a highly deoxygenated product with oxygen contents below the detection limit. However, the quality of fuel fractions produced has been a problem, manifesting as low octane numbers for the gasoline-range fraction and low cetane numbers for the diesel-range fraction. Incorporating an initial transition zone for hydrogenation during hydrotreating was shown to dramatically increase the diesel fraction cetane number from 24 to 45. A similar approach enabled the production of a cycloalkane-rich SAF fraction meeting key ASTM 4054 guidelines with respect to density, viscosity, heating value, volatility, freeze and flash point. Over 400 hours of hydrotreating for SAF was demonstrated with no signs of catalyst bed fouling, measured by pressure drop over the catalyst bed. Compared to other fuels, marine fuel is unique in that it does not require complete deoxygenation. We investigated the minimum hydrotreating requirements to produce fuel compatible with very low sulfur fuel oil, and the results suggested 30% reduction in hydrotreating costs for this approach. Co-hydroprocessing offers an opportunity to take advantage of refinery infrastructure and economies of scale although the operation is less flexible with respect to operating conditions. Co-hydroprocessing CFP oil with petroleum streams gave efficient deoxygenation at milder conditions (e.g. at temperatures of 320 Degrees Celsius) than required for standalone hydrotreating. Over 90% incorporation of biogenic carbon in the CFP oil was confirmed by carbon-14 analysis. Hydrotreating of CFP oil, whether by standalone or co-processing, can produce a variety of fuel cuts, whose quality can be tailored by changing process conditions. Challenges remain, including long-term catalyst performance and determining CFP oil quality requirements.

09 BIOMASS FUELS↗

A Rapid Procedure Development Approach for Multi-stage Validation of Novel Nuclear Power Plant Systems

The integration of renewable energy sources into the modern grid introduces variability in generation, challenging nuclear reactors to remain economically viable amid low wholesale electricity prices. To address this, Idaho National Laboratory?s Flexible Plant Operation and Generation program explores alternative revenue streams, including commoditizing excess thermal energy. A Thermal Power Dispatch (TPD) system enables steam extraction from the secondary loop for industrial uses like hydrogen production via high-temperature steam electrolysis.

99 - GENERAL AND MISCELLANEOUS↗

Beyond Price Taker: Optimizing Integrated Energy Systems Considering Market/Grid Interactions

Integrated Energy Systems (IES) combine two or more processes to increase the efficiency, flexibility of operation, and the overall reliability. However, analyzing IESs in volatile electricity markets is challenging, since the volatility in electricity prices makes the conventional levelized cost-type analysis less realistic. This work presents two approaches to address the challenge: price-taker and a surrogates-based approach for incorporating market interactions. The price-taker approach formulates a multiperiod optimization problem that takes the time-varying electricity prices into account, and solves the optimization problem to determine the optimal operational schedule that maximizes the chosen economic metric. This approach is successfully applied to investigate the performance of flexible power and hydrogen co-production systems. The market surrogates approach trains a machine learning model to predict the market behavior as a function of the characteristics of the IES. The trained surrogate model is used to optimize the design and operation of the given IES in an electricity market. This approach is demonstrated on a case study involving a nuclear power plant retrofitted with a low-temperature electrolysis unit to co-produce power and hydrogen.

beyond price taker↗

Enabling the Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

An important need for coal fired power plants is the ability to monitor multiple systems with ease and accuracy. Common implementations of these monitoring systems come with drawbacks due to the nature of coal fired power plants. Harsh environments, High Temperatures, and lots of RF (Radio Frequency) noise can create issues for accurately recording and transmitting data across wireless signals. In addition, as renewable energy sources come online, existing fossil fueled plants will need to operate more flexibly with their maintenance schedules outside of standard conditions. Therefore, additional sensing and control mechanisms need placed in existing plants to provide operators with more information such that maintenance decisions can be made well in advance of failures. A solution to this problem is the Next Generation of Smart Sensors, which leverages the power of 5G cellular signals and machine learning to overcome the myriad of problems with current implementations

20 FOSSIL-FUELED POWER PLANTS↗