Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Occupant Protection Standards Development

Current National Aeronautics and Space Administration (NASA) occupant protection standards and requirements are based on extrapolations of biodynamic models, which were based on human tests performed under pre-Space Shuttle human flight programs where the occupants were in different suit and seat configurations than is expected for the Multi Purpose Crew Vehicle (MPCV) and Commercial Crew programs. As a result, there is limited statistical validity to the occupant protection standards. Furthermore, the current standards and requirements have not been validated in relevant spaceflight suit, seat configurations or loading conditions. The objectives of this study were to develop new standards and requirements for occupant protection and rigorously validate these new standards with sub-injurious human testing. To accomplish these objectives we began by determining which critical injuries NASA would like to protect for. We then defined the anthropomorphic test device (ATD) and the associated injury metrics of interest. Finally, we conducted a literature review of available data for the Test Device for Human Occupant Restraint New Technology (THOR-NT) ATD to determine injury assessment reference values (IARV) to serve as a baseline for further development. To better understand NASA s environment, we propose conducting sub-injurious human testing in spaceflight seat and suit configurations with spaceflight dynamic loads, with a sufficiently high number of subjects to validate no injury during nominal landing loads. In addition to validate nominal loads, the THOR-NT ATD will be tested in the same conditions as the human volunteers, allowing correlation between human and ATD responses covering the Orion nominal landing environment and commercial vehicle expected nominal environments. All testing will be conducted without the suit and with the suit to ascertain the contribution of the suit to human and ATD responses. In addition to the testing campaign proposed, additional data analysis is proposed to mine existing human injury and response data from other sources, including military volunteer testing, automotive Crash Injury Research Engineering Network (CIREN), and IndyCar impact and injury data. These data sources can allow a better extrapolation of the ATD responses to off-nominal conditions above the nominal range that can safely be tested. These elements will be used to develop injury risk functions for each of the injury metrics measured from the ATD. These risk functions would serve as the basis for the NASA standards. Finally, we propose defining standard test methodology for evaluating future spacecraft designs against the IARVs, including developing a star-rating system to allow crew safety comparisons between vehicles.

Somers, Jeffrey T.↗

Safeguarding the Health of the NASA Astronaut Community: the Need for Expanded Medical Monitoring for Former NASA Astronauts Under the Astronaut Occupational Health Program

The astronaut community is unique, and may be disproportionately exposed to occupational hazards not commonly seen in other communities. The extent to which the demands of the astronaut occupation and exposure to spaceflight-related hazards affect the health of the astronaut population over the life course is not completely known. Provision of health screening services to active and former astronauts ensures individual, mission, and community health and safety. Currently, the NASA Johnson Space Center (JSC) Flight Medicine Clinic (FMC) provides extensive medical monitoring to active astronauts throughout their careers. Upon retirement, astronauts may voluntarily return to the JSC FMC for an annual preventive exam. However, current retiree monitoring includes only selected screening tests, representing an opportunity for augmentation. The potential latent health effects of spaceflight demand an expanded framework of testing for former astronauts. The need is two-fold: screening tests widely recommended for other aging communities are necessary for astronauts to rule out conditions resulting from the natural aging process (e.g., colonoscopy, mammography), as opposed to conditions resulting directly from the astronaut occupation; and increased breadth of monitoring services will improve the understanding of occupational health risks and longitudinal health of the astronaut community, past, present, and future. To meet this need, NASA has begun an extensive exploration of the overall approach, cost, and policy implications of expanding existing medical monitoring under the Astronaut Occupational Health program for former NASA astronauts.

Rossi, Meredith↗

Occupant thermal comfort inference using body shape information

Occupant thermal comfort may be inferred and improved using body shape information. Height, weight, and shoulder circumference of an occupant of a room may be obtained using a depth sensor. A model may be utilized that is trained on a dataset including information reflecting of occupant comfort within the room versus temperature, the model receiving, as inputs, the height, the weight, and the shoulder circumference of the occupant and environmental information and outputting a comfort class. A temperature set-point for is identified which the room occupant is identified by the model as having the comfort class being indicative of user comfort. Heating, ventilation, and air conditioning (HVAC) controls are adjusted for the room to the identified temperature set-point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HVAC control fine-grained occupancy pattern estimation

A thermal state of a plurality of zones of the building is updated according to a building thermal model and information received from temperature sensors of the building. Predicted occupant counts for an upcoming plurality of time slots for each of the plurality of zones are updated using actual occupancy counts for each of the plurality of zones. A misprediction type distribution for the upcoming plurality of time slots for each of the plurality of zones is updated, the misprediction type distribution indicating misprediction for true negatives, false positives, false negatives, and true positives. A total misprediction cost expectation is updated according to the predicted occupant counts and the misprediction type distribution. HVAC power for each of the plurality of zones is determined to optimize occupant thermal comfort weighted according to the predicted occupant counts while minimizing the total misprediction cost expectation. HVAC operation is controlled per the HVAC power.

Lin, Shan↗

Bayesian time-varying occupancy model for West Nile virus in Ontario, Canada

Occupancy models determine the true presence or absence of a species by adjusting for imperfect detection in surveys. They often assume that species presences can be detected only if sites are occupied during a sampling season. We extended these models to estimate occupancy rates that vary throughout a sampling season as well as account for spatial dependence among sites. For these methods, we constructed a fast Gibbs sampler with the Pólya-Gamma augmentation strategy to conduct inference on covariate effects. We applied these methods to evaluate how environmental conditions and surveillance practices are associated with the presence of West Nile virus in mosquito traps across Ontario, Canada from 2002 to 2017. We found that urban land cover and warm temperatures drove viral occupancy, whereas viral testing on pools with higher proportions of Culex mosquitoes was more likely to result in a positive test for West Nile virus. Models with time-varying occupancy effects achieved much lower Watanabe-Akaike information criteria than models without such effects. Our final model had strong predictive performance on test data that included some of the most extreme seasons, demonstrating the promise of these methods in the study of pathogens spread by mosquito vectors.

60 APPLIED LIFE SCIENCES↗

On the applicability of various levels of detail for occupant behavior representation and modeling in building performance simulation

Occupant behavior (OB) is one of the significant sources of uncertainty in building performance simulation. While OB modeling has received increased attention in the past decade, research on the degree of granularity or level of detail (LoD) required for representing occupants is still in the nascent stages. This paper analyzes the modeling and applicability of three LoDs to represent occupants in building performance assessment. A medium-sized prototype office building located in Chicago, Illinois is used as the simulation case study. Ten occupant-centric attributes are adopted to develop the LoDs for OB representation. We first demonstrate the different modeling approaches required for simulating the three fidelity levels. Later, we illustrate the suitability of the developed LoDs in supporting six building performance use cases across different lifecycle stages. Furthermore, this study intends to provide guidance for the building simulation community on appropriate OB representation to support various use cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A guideline to document occupant behavior models for advanced building controls

The availability of computational power, and a wealth of data from sensors have boosted the development of model-based predictive control for smart and effective control of advanced buildings in the last decade. More recently occupant-behavior models have been developed for including people in the building control loops. However, while important objectives of scientific research are reproducibility and replicability of results, not all information is available from published documents. Therefore, the aim of this paper is to propose a guideline for a thorough and standardized occupant-behavior model documentation. For that purpose, the literature screening for the existing occupant behavior models in building control was conducted, and the occupant behavior modeling processes were studied to extract practices and gaps for each of the following phases: problem statement, data collection, and preprocessing, model development, model evaluation, and model implementation. Here, the literature screening pointed out that the current state-of-the-art on model documentation shows little unification, which poses a particular burden for the model application and replication in field studies. In addition to the standardized model documentation, this work presented a model-evaluation schema that enabled benchmarking of different models in field settings as well as the recommendations on how OB models are integrated with the building system.

Building control↗

Scalable, Dual-Mode Occupancy Sensing for Commercial Venues

The ability to establish accurate occupancy is a key enabler for improved energy efficiency in human-occupied indoor spaces. The accurate counts can be used to adjust, in real-time, air exchange, heating, and cooling, to closely match the environmental needs of the occupants rather than to use a single setting based on maximum room occupancy. This project focuses on the use of overhead fisheye cameras and artificial intelligence (AI) algorithms as the technology to realize accurate people counting in large commercial spaces. We developed Computational Occupancy Sensing SYstem ("COSSY''), which supports large-scale deployment (thousands of square feet) and straightforward installation (using conventional power over ethernet), while providing high accuracy and low cost. COSSY has been validated at Boston University and by a third party, demonstrating people-counting accuracy of at least 89.5% in large spaces (2,000 sqft). A cost/benefit analysis performed for Boston commercial market indicates that a full payback of COSSY deployment costs due to energy savings would occur within 3-6 months from installation. Applications of COSSY reach far beyond saving energy. The precise people counting in real time could also be useful for emergency response (e.g., fire), in spatial analytics (e.g., office space management) and in some health applications (e.g., social distance assessment during pandemics).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revealing Site Occupancy in a Complex Oxide: Terbium Iron Garnet

Complex oxide films stabilized by epitaxial growth can exhibit large populations of point defects which have important effects on their properties. The site occupancy of pulsed laser-deposited epitaxial terbium iron garnet (TbIG) films with excess terbium (Tb) is analyzed, in which the terbium:iron (Tb:Fe)ratio is 0.86 compared to the stoichiometric value of 0.6. The magnetic properties of the TbIG are sensitive to site occupancy, exhibiting a higher compensation temperature (by 90 K) and a lower Curie temperature (by 40 K) than the bulk Tb 3 Fe 5 O 12 garnet. Data derived from X-ray core-level spectroscopy, magnetometry, and molecular field coefficient modeling are consistent with occupancy of the dodecahedral sites by Tb 3+ , the octahedral sites by Fe 3+ , Tb 3+ and vacancies, and the tetrahedral sites by Fe 3+ and vacancies. Energy dispersive X-ray spectroscopy in a scanning transmission electron microscope provides direct evidence of Tb Fe antisites. A small fraction of Fe 2+ is present, and oxygen vacancies are inferred to be present to maintain charge neutrality. In conclusion, variation of the site occupancies provides a path to considerable manipulation of the magnetic properties of epitaxial iron garnet films and other complex oxides, which readily accommodate stoichiometries not found in their bulk counterparts.

36 MATERIALS SCIENCE↗

Quantifying spatiotemporal variability in occupant exposure to an indoor airborne contaminant with an uncertain source location

Well-mixed zone models are often employed to compute indoor air quality and occupant exposures. While effective, a potential downside to assuming instantaneous, perfect mixing is underpredicting exposures to high intermittent concentrations within a room. When such cases are of concern, more spatially resolved models, like computational-fluid dynamics methods, are used for some or all of the zones. But, these models have higher computational costs and require more input information. A preferred compromise would be to continue with a multi-zone modeling approach for all rooms, but with a better assessment of the spatial variability within a room. Here to do so, we present a quantitative method for estimating a room's spatiotemporal variability, based on influential room parameters. Our proposed method disaggregates variability into the variability in a room's average concentration, and the spatial variability within the room relative to that average. This enables a detailed assessment of how variability in particular room parameters impacts the uncertain occupant exposures. To demonstrate the utility of this method, we simulate contaminant dispersion for a variety of possible source locations. We compute breathing-zone exposure during the releasing (source is active) and decaying (source is removed) periods. Using CFD methods, we found after a 30 minutes release the average standard deviation in the spatial distribution of exposure was approximately 28% of the source average exposure, whereas variability in the different average exposures was lower, only 10% of the total average. We also find that although uncertainty in the source location leads to variability in the average magnitude of transient exposure, it does not have a particularly large influence on the spatial distribution during the decaying period, or on the average contaminant removal rate. By systematically characterizing a room's average concentration, its variability, and the spatial variability within the room important insights can be gained as to how much uncertainty is introduced into occupant exposure predictions by assuming a uniform in-room contaminant concentration. We discuss how the results of these characterizations can improve our understanding of the uncertainty in occupant exposures relative to well-mixed models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing occupant behavior representation for interoperability between building information modeling and building energy modeling

Building Performance Simulation (BPS) has been adopted as an essential tool for designing, operating, and retrofitting buildings to optimize energy efficiency throughout the building life cycle. The Green Building XML (gbXML) schema facilitates seamless data exchange between Building Information Modeling (BIM) and Building Energy Modeling (BEM) software tools. However, limited occupant behavior (OB) representation in BIM often leads to inconsistent and inaccurate energy simulation in BEM software. This paper presents 154 systematic enhancements to the existing occupant behavior XML (obXML) schema v1.3.4, initially developed for standardizing OB representation for BEM, to address existing limitations and improve interoperability with BIM models. The enhancements encompass improved integration with BIM models through extended building representations and system operations, expanded support for advanced OB models with additional environmental parameters and mathematical capabilities, and implementation of a standardized model documentation framework. To facilitate seamless data transformation between gbXML and obXML schemas, we developed a publicly available gb-obXML Schema Converter. Three case studies demonstrate the enhanced schema’s capabilities: representation of building information using a two-story office building model, documentation of a window operation behavior model, and validation of the schema converter’s functionality. The enhanced obXML schema v1.4 enables sophisticated modeling of occupant-building interactions while maintaining consistency with industry-standard BIM schemas. The standardized documentation framework facilitates reproducibility and knowledge sharing in the OB research community, while the schema converter automates the integration of building information into OB simulation workflows. These enhancements establish a foundation for more accurate building performance simulation by supporting sophisticated representation of occupant behavior within the BIM-to-BEM simulation workflows.

Chung, Jihoon↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart detection of indoor occupant thermal state via infrared thermography, computer vision, and machine learning

The ability to measure occupants’ thermal state in real time will enable major advances in the control of air conditioning systems. This study proposes predicting occupant thermal state by a combination of infrared thermography, computer vision, and machine learning. The approach (1) uses cheek, nose, and hand temperatures because they are least subject to blockage by hair, glasses, and clothing; (2) measures the distribution of skin temperatures within geometrically defined sub-areas of the face and hand; and (3) uses temperature differences within and between these areas to eliminate the effects of calibration drift that are unavoidable in thermal infrared (TIR) cameras. Two series of tests were conducted, respectively in an outdoor carport and an indoor environmental chamber, collecting a total of 48,422 sets of cheek, nose, and hand skin temperatures using a TIR camera and computer-vision technology, coupled with 715 subjective responses of thermal sensations. To predict occupant thermal state, Random Forest classification models were built using either absolute skin temperatures (the maximum and median temperatures of cheek and hand segments, and the temperature of the central spot on the nose), or intra- and inter-segment temperature differences of cheeks, hands, and nose. These measurements were found to accurately predict occupant thermal state. Using the maximum and median temperatures for cheek and nose, or for cheek and hand, predicts thermal state with an accuracy of 92–96%. In conclusion, using only the intra- and inter-segment temperature differences from cheek and nose is 83% accurate; adding the hand temperature differences increases the accuracy to 96%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning occupant-centric control and operations

Occupant-Centric Control and Operation (OCC) represents a transformative approach to building management, integrating sensing of indoor environmental quality, occupant presence, and occupant-building interactions. These data are then utilized to optimize both operational efficiency and occupant comfort. This paper summarizes the findings from the IEA-EBC Annex 79 research program's subtask on real world implementations of OCC during the past 5 years. First, in Q1 and Q2, we provide a definition and categorization of OCC. Q3 addresses the role of building operators for OCC, while Q4 describes the implications for designers. Then, Q5 and Q6 discuss the role and possibilities of OCC for load flexibility, and for pandemic induced paradigm shifts in the built environment, respectively. In Q7, we provide a taxonomy and selection process of OCC, while Q8 details real world implementation case studies. Finally, Q9 explains the limits of OCC, and Q10 provides a vision for future research opportunities. Furthermore, our findings offer valuable insights for researchers, practitioners, and policy makers, contributing to the ongoing discourse on the future of building operations management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using occupant interaction with advanced lighting systems to understand opportunities for energy optimization: Control data from a hospital NICU

For this study, lighting system control data from five patient rooms in a neonatal intensive care unit (NICU) over a 25-week monitoring period were analyzed to better understand how the NICU staff and families interacted with an automatic tunable lighting system (variable spectrum and intensity) with manual override options. The data were analyzed to determine the amount of time spent in available lighting modes, estimate energy consumption, and to observe any patterns in how the lighting system was being used by occupants. Further analysis revealed opportunities for optimizing the system for occupant needs and energy savings. The patient room occupants were clearly engaged in using the lighting system throughout the 24-hour day to meet needs and preferences. Giving occupants control over the lighting system did not result in a considerable increase in energy use. Implementing a time-out would minimize the extended periods of time when the lights were left on without need at the highest brightness level, further decreasing energy use. This analysis reveals the potential of lighting control data to contribute to energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A-site occupancy effects on structure, ionic conductivity, and thermodynamic stability of KxMgx/2Ti8−x/2O16

Abstract K x Mg x /2 Ti 8− x /2 O 16 (1.54 ≤ x ≤ 2) hollandite samples synthesized using a conventional solid-state route were used to investigate the effect of structure, ionic conductivity, and thermodynamic stability as a function of A-site (K) occupancy. The ionic conductivity, as measured using AC impedance spectroscopy, decreased as the A-site occupancy (and K content) increased. Titanate hollandite, of the form K x Mg x /2 Ti 8− x /2 O 16 , was measured using high-temperature oxide melt solution calorimetry in sodium molybdate (3Na 2 O $$\bullet$$ ∙ 4MoO 3 ) solvent at 804 $$^\circ{\rm C}$$ ∘ C . The enthalpies of formation are strongly exothermic indicating that they are thermodynamically stable relative to their constituent oxides. Previous studies have demonstrated increased stability with an increase in Cs content at fixed A-site occupancy. This work demonstrated an increase in the stability for the K-bearing hollandite samples with an increase in K content and tunnel occupancy. The measured enthalpies of formation (∆ H f,ox ) were in good agreement with density functional theory (DFT) predictions. Graphical abstract

Cassell, Nakeshma S.↗

NASA Occupational Health Program FY98 Self-Assessment

The NASA Functional Management Review process requires that each NASA Center conduct self-assessments of each functional area. Self-Assessments were completed in June 1998 and results were presented during this conference session. During FY 97 NASA Occupational Health Assessment Team activities, a decision was made to refine the NASA Self-Assessment Process. NASA Centers were involved in the ISO registration process at that time and wanted to use the management systems approach to evaluate their occupational health programs. This approach appeared to be more consistent with NASA's management philosophy and would likely confer status needed by Senior Agency Management for the program. During FY 98 the Agency Occupational Health Program Office developed a revised self-assessment methodology based on the Occupational Health and Safety Management System developed by the American Industrial Hygiene Association. This process was distributed to NASA Centers in March 1998 and completed in June 1998. The Center Self Assessment data will provide an essential baseline on the status of OHP management processes at NASA Centers. That baseline will be presented to Enterprise Associate Administrators and DASHO on September 22, 1998 and used as a basis for discussion during FY 99 visits to NASA Centers. The process surfaced several key management system elements warranting further support from the Lead Center. Input and feedback from NASA Centers will be essential to defining and refining future self assessment efforts.

Brisbin, Steven G.↗

Rollout and Turnoff (ROTO) Guidance and Information Displays: Effect on Runway Occupancy Time in Simulated Low-Visibility Landings

This report examines a rollout and turnoff (ROTO) system for reducing the runway occupancy time for transport aircraft in low-visibility weather. Simulator runs were made to evaluate the system that includes a head-up display (HUD) to show the pilot a graphical overlay of the runway along with guidance and steering information to a chosen exit. Fourteen pilots (airline, corporate jet, and research pilots) collectively flew a total of 560 rollout and turnoff runs using all eight runways at Hartsfield Atlanta International Airport. The runs consisted of 280 runs for each of two runway visual ranges (RVRs) (300 and 1200 ft). For each visual range, half the runs were conducted with the HUD information and half without. For the runs conducted with the HUD information, the runway occupancy times were lower and more consistent. The effect was more pronounced as visibility decreased. For the 1200-ft visibility, the runway occupancy times were 13% lower with HUD information (46.1 versus 52.8 sec). Similarly, for the 300-ft visibility, the times were 28% lower (45.4 versus 63.0 sec). Also, for the runs with HUD information, 78% (RVR 1200) and 75% (RVR 300) had runway occupancy times less than 50 sec, versus 41 and 20%, respectively, without HUD information.

Hueschen, Richard M.↗