Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

79 records · Page 5

Internship Presentation: Reactor System Facility Modification to Detect Compromised Human Machine Interfaces

This study presents a multi-layered Industrial Control System (ICS)/Operational Technology (OT) security architecture aimed at detecting and mitigating compromised Human Machine Interface (HMI) and Instrumentation & Control (I&C) systems within the Flowing Autoclave System (FAS) at Idaho National Laboratory (INL). The approach combines network security solutions, hash-based algorithms, and blockchain technologies to verify system integrity and provide an immutable record of network activity. This integrated three-pronged strategy enhances the detection of system compromises, enabling preemptive action before significant damage occurs.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Capabilities for Water Sector Infrastructure Resilience - Prioritizing RD&D in a Target Rich, Resource Poor Sector

WSTB & Water Sector Security Program Expansion Objective: Incubate and shepherd a public-private consortium of joint seal US government sponsors and industry stakeholders to build out industrial control system (ICS) and operational technology (OT) architecture of the Idaho National Laboratory (INL) Water Security Test Bed (WSTB) asset to enable research, testing, and cyber workforce training related to evolving cyber-physical and physical vulnerabilities and threats in the water sector.

99 - GENERAL AND MISCELLANEOUS↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Formally Verified ZTA Requirements for OT/ICS Environments with Isabelle/HOL

The clean energy transformation includes the integration of distributed energy resources with the power grid, which has led to a substantial increase in the complexity of power grids infrastructure and the underlying operational technology environment. Power grids infrastructure represents an operational technology environment that has become a system of systems, integrating heterogeneous devices which are both software-and hardware-intensive; as a result, there are increasing demands to exploit advances in the commodity of software-hardware infrastructures to improve energy systems requirements such as cybersecurity and resilience. In such a setting, system requirements at different levels mix, which leads to vulnerabilities and undesirable outcomes. The use of formal methods to characterize and prove system requirements removes ambiguity, increases automation, and provides high levels of assurance and reliability. In this paper, we contribute a methodology and a framework for the system-level verification of zero trust architecture requirements in operational technology environments. We define a formal specification for the core functionalities of operational technology environments, the corresponding invariants, and security proofs. Of particular note is our modular approach for the formal verification of asynchronous interactions in operational technology environments. The formal specification and the proofs have been mechanized using the interactive theorem proving environment Isabelle/HOL.

formal methods↗

Malcolm Deployment Guide for Solar Power Generation Plants

This guide provides detailed instructions for deploying Malcolm in Solar Power Generation systems. It covers the deployment process, from understanding the network architecture of these systems to configuring network switches and Switched Port Analyzer (SPAN) ports or mirror ports or TAPs. The guide also includes best practices for deploying Hedgehog sensors, another critical component in these systems. Following this guide, users can enhance network visibility, improve their system’s security, and effectively troubleshoot common issues.

14 SOLAR ENERGY↗

Equipment Self-Assessment Guide Checklist

This Equipment Self-Assessment Checklist is designed for asset owners and operators (AOOs) responsible for the deployment, operation, maintenance, or cybersecurity oversight of grid systems and digital energy technologies. It provides a structured inspection checklist for evaluating the security, integrity, and operational trustworthiness of equipment across substations, generation sites, distributed energy resources (DERs), and control environments.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗