Sensitivity and uncertainty analysis of PWR spent fuel observables to operational and model parameters
Sensitivity and uncertainty analyses of spent nuclear fuel (SNF) observables - decay heat, neutron and γ-ray emission rate - to operational and model parameters have been performed. A 2D model representing a typical PWR 17x17 UO{sub 2} fuel assembly has been taken as reference. The Serpent code and ENDF/B-VII.1 evaluated nuclear data library have been used for the analyses. Relative uncertainty of decay heat, neutron and γ-ray emission rates due to Monte Carlo counting statistics, as well as the number of fuel pin radial regions required for an accurate characterization of SNF neutron emission, have been estimated. A parametric study has been carried out to investigate the impact of the homogenization to an average value of the fuel and moderator temperature, boron concentration power and burnup on the prediction of the selected observables. In addition, linear sensitivity coefficients have been calculated. (authors)