Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Defect Production and Microstructural Feature Impact for Radiation Damage in Additively Manufactured 316 Stainless Steel

This milestone presents multi-scale modeling research results for additively manufactured 316 stainless steel. A combination of phase field, cluster dynamics, molecular dynamics, and density functional theory with machine learning is used, allowing for predictions of radiation-driven microstructural evolution in additively manufactured 316 stainless steel over a range of temperatures, damage rates, neutron spectra, and microstructures, and supporting the development of combined ion and neutron irradiation for material qualification. Informed by ion irradiation and neutron irradiation results across the Advanced Materials and Manufacturing Technologies program, we investigate the unique aspects of radiation-driven microstructure evolution in additively manufactured 316 stainless steel. In particular, we focus on understanding the impact of carbon concentration (varying, for example, between the 316L and 316H standards) on void formation; radiation-induced segregation at dislocation cells and grain boundaries; and the evolution of dislocation loops and network dislocation populations. We find that the unique characteristics of the additively manufactured microstructures must be accounted for in understanding the evolution of dislocation populations under thermal and irradiation conditions, such as the variation in sink strengths arising due to the variation in dislocation density. We also find that the radiation-induced segregation of Cr and Ni to grain boundaries and cell walls differs due to the differences in their defect sink biases. We also find that increasing the Ni content can slow vacancy diffusion, which may provide a mechanism for the observed reduction in transient swelling rate for austenitic Fe-Cr-Ni alloys with increasing Ni content. In addition, ion irradiations have shown that increasing carbon content in 316 SS results in a larger population of smaller voids, suggesting reduced vacancy diffusion. Our results show that the carbon content of additively manufactured 316 SS has a significant impact on the migration rate of defect clusters. The presence of carbon atoms results in carbon-vacancy trapping, significantly reducing the diffusion rate of vacancies. Carbon atoms may also be trapped near the surface of a void, which may reduce void growth by trapping vacancies that diffuse toward the void.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Problem with gradual absorption in MSD/MSC calculations

Replacing classical exciton model with the better founded Multistep Direct (MSD) and Multistep Compound (MSC) mechanisms has been impeded by incapability of the latter models to describe central part of the neutron emission spectra at incident neutron energies of about 14 MeV and above. We have ascribed this deficiency to the decrease of absorption to the MSC mechanism resulting from the concept of gradual absorption. We were able to obtain very good reproduction of experimentally measured neutron spectra using MSD/MSC calculations when this option was turned off. Such treatment is, however, at odds with the fundamental distinction between MSD and MSC mechanisms that should proceed through the chain of open (P-space) and closed (Q-space) configurations respectively. By blocking gradual absorption we allow the first stage of MSC to be fully populated from the incident channel that at higher incident energies is impossible. We discuss various attempts of addressing the problem that, so far, remains open. In addition, we present an evidence for much tighter spin distribution of particle-hole states than normally assumed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Problem with gradual absorption in MSD/MSC calculations

Replacing classical exciton model with the better founded Multi-step Direct (MSD) and Multistep Compound (MSC) mechanisms has been impeded by incapability of the latter models to describe central part of the neutron emission spectra at incident neutron energies of about 14 MeV and above. We have ascribed this deficiency to the decrease of absorption to the MSC mechanism resulting from the concept of gradual absorption. We were able to obtain very good reproduction of experimentally measured neutron spectra using MSD/MSC calculations when this option was turned off. Such treatment is, however, at odds with the fundamental distinction between MSD and MSC mechanisms that should proceed through the chain of open (P-space) and closed (Q-space) configurations respectively. By blocking gradual absorption we allow the first stage of MSC to be fully populated from the incident channel that at higher incident energies is impossible. We discuss various attempts of addressing the problem that, so far, remains open. In addition, we present an evidence for much tighter spin distribution of particle-hole states than normally assumed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the prompt fission neutron spectrum from 800 keV to 10 MeV for 240 Pu(sf) and for the 240 Pu($n,f$) reaction induced by neutrons of energy from 1–20 MeV

Here, the presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, (n,f), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, (sf), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu(sf) and the 240 Pu(n,f) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the (n,f) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of mid- Z gas fill on dynamics and performance of shock-driven implosions at the OMEGA laser

Shock-driven implosions with 100% deuterium (D 2 ) gas fill compared to implosions with 50:50 nitrogen-deuterium (N 2 ⁢D 2 ) gas fill have been performed at the OMEGA laser facility to test the impact of the added mid-Ζ fill gas on implosion performance. Ion temperature (Τ ion ) as inferred from the width of measured DD-neutron spectra is seen to be 34%±6% higher for the N 2⁢ D 2 implosions than for the D 2 -only case, while the DD-neutron yield from the D 2 -only implosion is 7.2±0.5 times higher than from the N 2⁢ D 2 gas fill. The T ion enhancement for N 2 ⁢D 2 is observed in spite of the higher Z, which might be expected to lead to higher radiative loss, and higher shock strength for the D 2 -only versus N 2 ⁢D 2 implosions due to lower mass, and is understood in terms of increased shock heating of N compared to D, heat transfer from N to D prior to burn, and limited amount of ion-electron-equilibration-mediated additional radiative loss due to the added higher-Z material. Further, this picture is supported by interspecies equilibration timescales for these implosions, constrained by experimental observables. The one-dimensional (1D) kinetic Vlasov-Fokker-Planck code ifp and the radiation hydrodynamic simulation codes hyades (1D) and xrage [1D, two-dimensional (2D)] are brought to bear to understand the observed yield ratio. Comparing measurements and simulations, the yield loss in the N 2 ⁢D 2 implosions relative to the pure D 2 -fill implosion is determined to result from the reduced amount of D 2 in the fill (fourfold effect on yield) combined with a lower fraction of the D 2 fuel being hot enough to burn in the N 2 ⁢D 2 case. The experimental yield and T ion ratio observations are relatively well matched by the kinetic simulations, which suggest interspecies diffusion is responsible for the lower fraction of hot D 2 in the N 2 ⁢D 2 relative to the D 2 -only case. The simulated absolute yields are higher than measured; a comparison of 1D versus 2D XRAGE simulations suggest that this can be explained by dimensional effects. The hydrodynamic simulations suggest that radiative losses primarily impact the implosion edges, with ion-electron equilibration times being too long in the implosion cores. The observations of increased T ion and limited additional yield loss (on top of the fourfold expected from the difference in D content) for the N 2 ⁢D 2 versus D 2 -only fill suggest it is feasible to develop the platform for studying CNO-cycle-relevant nuclear reactions in a plasma environment.

47 OTHER INSTRUMENTATION↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Custom ORIGEN Libraries for Tritium Production in Discrete Burnable Absorbers

The ORIGEN module in SCALE is a common method of performing quick depletion and irradiation calculations of various materials in light-water reactors. However, these analyses depend on the neutron spectra in the ARP libraries being accurate for the situation presented. When using insertable burnable absorbers in a LWR with Li-6 in order to produce tritium, the neutron spectrum is highly different than those in the default libraries in ORIGEN, which leads to significant mispredictions in tritium production. Therefore, custom libraries are required, and when comparing to lattice physics codes (CASMO5 and WIMS10) with ORIGEN, using custom libraries is much more accurate than using the default libraries.

Ivanusa, Pavlo↗

The calculation of light element impurity (α, n) yield curves in a PuO 2 matrix and associated specific yield coefficients: Influence of the reaction cross sections

Most of the Pu separated from irradiated commercial nuclear fuel is stored as PuO 2 . The primary quantitative nondestructive measurement technique used to verify the amount of Pu in storage containers is passive neutron correlation counting. An important physical property of the oxide material is the ratio, α, of the rate of (α, n) neutrons produced inside the item to the rate of neutrons produced by spontaneous fission. This ratio influences the precision of the correlated counting method and affects the interpretation of the data because of how it changes both the primary total neutron production rate and the rate of induced fission events taking place inside the item. In addition to the main O(α, n) contribution, additional contributions come from α-particle interactions with light element impurities that are inevitably present. In this work, we calculate specific (α, n) yield coefficients, expressed in units of neutrons per second per gram of α-emitting nuclide per part per million by mass of the specified impurity element distributed in a pure PuO 2 matrix, for some key α-emitting actinides commonly present in reprocessed Pu ( 238–242 Pu+ 241 Am). These coefficients are directly applicable to nuclear safeguards verification work in which the α ratio is often calculated from the Pu-isotopic composition and chemical information obtained by other means. Further, they also provide a convenient up-to-date reference set against which values generated by other methods can be compared. Results are presented for impurities with atomic number from 3 to 17 inclusive, plus K and Fe. In most cases, these coefficients are not expected to change by more than 5%–10% at any time in the future. However, as new data become available, changes as large as 20% may be needed for some targets (e.g., F). The present yield calculations are limited by the general shortage of quality experimental total (α, n) reaction cross section data, which, together with unexplained variation between determinations, means that an objective and coherent evaluation is not possible. The situation is even less satisfactory for the partial differential cross section needed to calculate neutron spectra.

(𝛼, n) reactions↗

Review of Neutron Yield from (α, n) Reactions: Data, Methods, and Prospects

Understanding the radiogenic neutron production rate through the (α, n) reaction is crucial in many areas of physics, including dark matter searches, neutrino studies, and nuclear astrophysics. In addition to its relevance for fundamental research, the (α, n) reaction also plays a significant role in nuclear energy technologies, for example by contributing to neutron production in subcritical systems using UO2, as well as in applications such as medical physics. This review examines the current state of (α, n) yield calculations and neutron spectra, describes the computational tools used for their estimation, and discusses the available cross-section data. We discuss the uncertainties affecting (α, n) yield estimations and propose a strategy to enhance their accuracy. Furthermore, this paper discusses and emphasizes the need for new measurements of (α, n) cross-sections for a variety of relevant materials. Such measurements are essential for improving neutron flux predictions, which are crucial for reducing uncertainties in sensitivity estimates for next-generation physics experiments operating in the keV—MeV range.

(α, n)reactions↗

IAEA Photonuclear Data Library 2019

Here, photo-induced reaction cross section data are of importance for a variety of current or emerging applications, such as radiation shielding design and radiation transport analyses, calculations of absorbed dose in the human body during radiotherapy, physics and technology of fission reactors (influence of photo-reactions on neutron balance) and fusion reactors (plasma diagnostics and shielding), activation analyses, safeguards and inspection technologies, nuclear waste transmutation, medical isotope production and astrophysical applications. To address these data needs the IAEA Photonuclear Data library was produced in 1999, containing evaluated photo-induced cross sections and neutron spectra for 164 nuclides which were deemed relevant for the applications. Since the release of the IAEA Photonuclear Data Library however, new experimental data as well as new methods to assess the reliability of experimental cross sections have become available. Theoretical models and input parameters used to evaluate photo-induced reactions have improved significantly over the years. In addition, new measurements of partial photoneutron cross sections using mono-energetic photon beams and advanced neutron detection systems have been performed allowing for the validation of the evaluations and assessments of the experimental data. Furthermore, technological advances have led to the construction of new and more powerful gamma-beam facilities, therefore new data needs are emerging. We report our coordinated efforts to address these data needs and present the results of the new up-to-date evaluations included in the new updated IAEA Photonuclear Data Library consisting of 219 nuclides. The new library includes 188 new evaluations produced by the CRP evaluators, and one evaluation taken from the JENDL/PD-2016 library, while 20 evaluations were retained from the previous 1999 IAEA Photonuclear Data Library. In most of the cases, the photon energy goes up to 200 MeV. A total of 55 nuclides are new in this library reflecting the progress in measurements but also the developing data needs. In this paper we discuss the new assessment method and make recommendations to the user community in cases where the experimental data are discrepant and the assessments disagree. In addition, in the absence of experimental data, we present model predictions for photo-induced reaction cross section on nuclides of potential interest to medical radioisotope production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Flux Isotope Reactor Neutron Spectrum Shape Estimation From Activation Experiment Data

Here, this article provides a comprehensive review of historical irradiation dosimetry available for different locations within the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This article includes a summary of the available measured activation target data covering a span of over 15 years and 39 experimental campaigns, including 200 individual sample locations evaluated. Using this broad set of data, we reconstruct historic average neutron spectra shapes for HFIR at various locations, including within the flux trap region, beryllium reflectors, and hydraulic tube (HT) regions, at both the 100- and 85-MW operational power. Our findings indicate that the general axial flux distribution shows a relatively small change in transition from 100- to 85-MW operating power, with differences of -6% to +15% for the thermal energy range and around -16% to +8% for the fast range, indicating a sharper drop-off of the thermal neutron flux away from the axial center. Compared with historical dosimetry estimates of the HFIR flux shape, we generally find a moderately broader axial profile shape for thermal neutrons in the interior target regions for the 100-MW samples evaluated but relatively close agreement for the present 85-MW flux shape for both thermal and fast fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Accelerated Fuel Qualification of Fast Modular Reactor Fuel in a Thermal Reactor: Modeling and Simulation Paired with Irradiation Testing

The accelerated fuel qualification (AFQ) methodology is applied by simulating accelerated fuel tests of the General Atomics Electromagnetic Systems’ fuel system for its 44-MW(electric) gas-cooled, fast-spectrum fast modular reactor (FMR). This fuel is comprised of UO 2 pellets in SiGA® cladding, a silicon carbide ceramic matrix composite. Fast reactors, like the FMR, offer many benefits, including high fuel utilization and flexibility, but may require a lengthy material design process if tests are performed using fast neutron irradiation alone. A thermal neutron irradiation can instead be used to rapidly test how well key components of the current material models extend to high burnup. Thermal neutrons produce a different radial power distribution within the pin than fast neutrons. However, the temperature and burnup values for the two neutron types are comparable, and the differences between the simulated fuel responses are relatively small, demonstrating the weak sensitivity of the physics-based fuel model calculations on the neutron type and the irradiation rate. Furthermore, the deformation of the SiGA cladding saturates after about 1 displacement per atom for both neutron spectra. In an accelerated fuel test, the irradiation time required to reach the target fuel burnup can be reduced by a factor of 3 by using a small rodlet with a 45% smaller pellet diameter while maintaining the same linear power. Therefore, the time for data collection up to high burnup can be significantly reduced while maintaining the same temperature profile, which largely determines the material response. Tests of fuel rodlets of standard and compact size will be carried out in the Idaho National Laboratory’s Advanced Test Reactor (ATR), including full size and compact rodlets with varying gap sizes. By applying physics-based mechanistic modeling and simulation in accordance with the AFQ methodology, this type of compact rodlet testing in a thermal test reactor captures the necessary phenomena to test fuel material models up to high burnup and to simulate the expected impact of fast neutron radiation on the fuel in FMR operations. Finally, this approach to testing fast reactor fuels in existing thermal test reactors, paired with advanced physics-based mechanistic modeling and simulation, is expected to be applicable to a range of advanced fuels and will decrease the overall fuel qualification timeframe from decades to years.

Advanced test reactor (ATR)↗

The Use of High-Density UN Fuel in Heat-Pipe Microreactors

Heat-pipe microreactors (HPMRs) are very small-scale nuclear reactors that employ heat pipes (HPs) for heat removal. HPMRs can be easily integrated with other forms of renewable energies, can be used for emergency responses to disaster relief zones, can be deployed in remote locations not connected to the grid, and can be removed from sites and replaced by new ones. HPMRs can also be used for space missions as HPs do not rely on gravity for heat transfer. Conventional fuel materials, such as uranium oxide (UO 2 ) and uranium oxycarbide (UCO), are currently considered in most existing HPMR designs, but ceramic uranium nitride (UN) fuel that has high uranium density, high thermal conductivity, and high melting point may become a better fuel candidate. Through neutronics calculations, this paper assesses the impact of using UN fuel in HPMRs with two different neutron spectra (fast and thermal) and two different fuel forms [traditional solid fuel pellets and TRi-structural-ISOtropic (TRISO) fuel compacts]. It was concluded that retrofitting HPMRs with UN fuel has the potential to reduce the initial 235 U enrichment requirement by ~3 wt% (to keep the same cycle length) or increase the cycle length (by keeping the same initial 235 U enrichment), which enables more compact and transportable HPMR core designs. However, using UN fuel decreases the control element worth [by up to 20% for the Special Purpose Reactor (SPR) and 5% for HP-MR] and is up to 80% more costly. Increasing 15 N enrichment can further decrease the initial 235 U enrichment requirement and increase the control element worth but is more costly. In conclusion, compared to fast-spectrum HPMRs fueled with solid pellet fuels, retrofitting UN fuel is more suitable for thermal-spectrum HPMRs fueled with TRISO fuel compacts, where the neutron spectrum hardening caused by using UN is less significant.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin dynamics in linear magnetoelectric material Mn 3 Ta 2 O 8

We performed inelastic neutron scattering experiments on single crystal samples of a linear magnetoelectric material Mn 3 Ta 2 O 8 , which exhibits a collinear antiferromagnetic order, to reveal the spin dynamics. Numerous modes observed in the neutron spectra were reasonably reproduced by linear spin-wave theory on the basis of the spin Hamiltonian including eight Heisenberg interactions and an easy-plane type single-ion anisotropy. In conclusion, the presence of strong frustration was found in the identified spin Hamiltonian.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolving the dynamic correlated disorder in KTa 1- x Nb x O 3

Understanding the complex temporal and spatial correlations of ions in disordered perovskite oxides is critical to rationalize their functional properties. Here, in this study, we provide new insights into the longstanding controversy regarding the off-centering of transition metal ions in the archetypal ferroelectric alloy KTa 1-x Nb x O 3 (KTN). By mapping the full energy (E) and wavevector (Q) dependence of the dynamical structure factor S(Q, E) using neutron scattering, and rationalizing our observations with atomistic simulations leveraging machine learning, we fully resolve the static vs dynamic nature of diffuse scattering sheets, as well as their composition (x) and temperature dependence. Our first-principles simulations, extended with machine-learning molecular dynamics, reproduce both inelastic neutron spectra and diffuse features, and establish how dynamically-correlated transition metal off-centerings couple to phonons, unifying local and collective viewpoints. This study sheds new light into an exemplary ferroelectric systems and shows the importance of mapping the full S(Q, E) to reveal critical spatio-temporal correlations of atomic disorder from which functional properties emerge.

42 ENGINEERING↗

A generalized forward fit for neutron detectors with energy-dependent response functions

To date, most analysis of neutron time-of-flight data from inertial confinement fusion experiments has focused on the relatively small range of energies corresponding to the primary neutrons from DD and DT fusion, and have therefore employed instrument response functions (IRF’s) corresponding to monoenergetic 2.45-MeV or 14.03-MeV neutrons. For analysis of time-of-flight signals corresponding to broader ranges of neutron energies, accurate treatment of the data requires the use of an energy-dependent IRF. Here, this work describes interpolation of the IRF for neutrons of arbitrary energy, construction of an energy-dependent IRF, and application of this IRF in a forward fit via matrix multiplication. As an example of the application of this method, an analysis of synthetic data relevant to TT fusion experiments at the Omega Laser Facility is discussed. This example is used to illustrate the differences between a forward fit that uses an energy-dependent IRF and a forward fit that uses a monoenergetic IRF. Use of the energy-dependent IRF is shown to result in accurate inference of the fit parameters of interest.

47 OTHER INSTRUMENTATION↗