Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparative Evaluation of Spectral Methods for Robust Reactor Noise Estimation

Reactor noise analysis provides a noninvasive means to determine neutron kinetic parameters from stochastic fluctuations in detector signals. However, standard cross-power spectral density (CPSD) analyses can be sensitive to numerical processing choices, which may introduce processing-dependent systematic shifts in estimates of the prompt neutron decay constant (α) and limit reproducibility. This study uses a hybrid multitaper–Welch spectral estimator to analyze subcritical noise measurements from a fast-spectrum critical assembly. The decay constant α was extracted using three frequency-domain methods: the CPSD, the magnitude-squared coherence (MSC), and the generalized magnitude-squared coherence (GMSC). These coherence-based estimators normalize detector auto-spectral structure and are expected to reduce the sensitivity of fitted α values to processing parameters. A Sobol global sensitivity analysis identified which numerical inputs most strongly influence the fitted values of α. All estimators produced a linear dependence of α on inverse count rate, with delayed-critical extrapolations near 1.7 × 10 4 s −1 , in agreement within 8% of MCNP6.3 KOPTS benchmark calculations. Sensitivity results show that while the CPSD depends on both time-bin width and taper selection, the MSC and GMSC are dominated by time-bin width alone, indicating reduced parameter coupling and greater robustness to processing variability. These findings demonstrate the feasibility and practical value of coherence-based spectral estimators for extracting α from reactor noise and support their broader application to multi-detector and irregular datasets in subcritical system characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tagged DVCS on neutron with the CLAS12 Experiment and the detector BONuS12 at Jefferson Lab (USA)

Hadronic physics studies the properties of the proton and neutron. The theory of Quantum Chromodynamics (QCD) governs the structure of hadrons. Non-perturbative structure functions are used to describe the hadrons? structure. Generalized Parton Distributions (GPDs) are a set of structure functions providing access to a 3D view of the nucleon. GPDs contain information about the longitudinal momentum and transverse position of quarks and their correlation. They are related to the spin structure and play a role in solving the proton spin puzzle. They provide access to the quarks? orbital angular momentum, a crucial puzzle piece. For this, measurements on the proton, already present, and neutron are necessary. This thesis aims to explore Compton scattering on the neutron with a deuterium target by measuring the spectator proton with the CLAS12 detector and the BONuS12 RTPC at Jefferson Lab. This work first describes the implementation, which I carried out, of a Kalman filter to reconstruct spectator protons in the BONuS12 detector. The second part of the manuscript is dedicated to the work on the analysis of DVCS on the neutron with the subtraction of background noises. Two different methods for the subtraction of ?0 will be detailed. Finally, the obtained results are presented and discussed

Ouillon, Mathieu↗

Structural magnetic glassiness in the spin ice Dy 2 Ti 2 O 7

The origin and nature of glassy dynamics presents one of the central enigmas of condensed-matter physics across a broad range of systems ranging from window glass to spin glasses. The spin-ice compound Dy 2 Ti 2 O 7 , which is perhaps best known as hosting a three-dimensional Coulomb spin liquid with magnetically charged monopole excitations, also falls out of equilibrium at low temperature. How and why it does so remains an open question. Based on an analysis of low-temperature diffuse neutron-scattering experiments employing different cooling protocols alongside recent magnetic noise studies, combined with extensive numerical modeling, we argue that upon cooling, the spins freeze into what may be termed a “structural magnetic glass,” without an a priori need for chemical or structural disorder. Specifically, our model indicates the presence of frustration on two levels, first producing a near-degenerate constrained manifold inside which phase ordering kinetics is in turn frustrated. A remarkable feature is that monopoles act as sole annealers of the spin network and their pathways and history encode the development of glass dynamics, allowing the glass formation to be visualized. Our results suggest that spin ice Dy 2 Ti 2 O 7 provides one prototype of magnetic glass formation specifically and a setting for the study of kinetically constrained systems more generally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Characterization and pulse-shape discrimination of a multi-stacked structure of ZnS: Ag/PMMA for fast-neutron detection in high-flux environments

The Micro-Layered Fast Neutron Detector (MLFD) is a proton-recoil scintillator that incorporates the basic concept of a Hornyak button detector with an improved design using a layered structure of ZnS:Ag and PMMA (polymethyl methacrylate). The MLFD was predicted to have low sensitivity to gamma rays, hence pulse shape discrimination was performed to determine the gamma-ray contribution. Presented in this paper are the pulse-shape discrimination characteristics of the MLFD. Additionally, the charge integration technique was employed to discriminate between the neutrons and gamma rays using a fast digitzer. The MLFD was found to exhibit excellent neutron/gamma-ray discrimination, with the highest Figure-of-Merit (FoM) being 4.56. With PSD, the neutron signal is distinct from gamma-ray, Ĉerenkov and electronic noise signals. This clear separation was achieved due to the large differences in decay times of the neutron and gamma-ray-induced pulses in the ZnS:Ag phosphor. The MLFD can be employed in high gamma-ray exposure fields, up to at least 1287.7 mR/hr, without appreciable degradation in PSD performance.

47 OTHER INSTRUMENTATION↗

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

Bootstrap estimation of the effect of instrument response function uncertainty on the reconstruction of fusion neutron sources

Neutron imagers are important diagnostics for the inertial confinement fusion implosions at the National Ignition Facility. They provide two- and three-dimensional reconstructions of the neutron source shape that are key indicators of the overall performance. To interpret the shape results properly, it is critical to estimate the uncertainty in those reconstructions. There are two main sources of uncertainties: limited neutron statistics, leading to random errors in the reconstructed images, and incomplete knowledge of the instrument response function (the pinhole-dependent point spread function). While the statistical errors dominate the uncertainty for lower yield deuterium-tritium (DT) shots, errors due to the instrument response function dominate the uncertainty for DT yields on the order of 10 16 neutrons or higher. In this work, a bootstrapping method estimates the uncertainty in a reconstructed image due to the incomplete knowledge of the instrument response function. The main reconstruction is created from the fixed collection of pinhole images that are best aligned with the neutron source. Additional reconstructions are then built using subsets of that collection of images. Variations in the shapes of these additional reconstructions originate solely from uncertainties in the instrument response function, allowing us to use them to provide an additional systematic uncertainty estimate.

47 OTHER INSTRUMENTATION↗

High-Energy Electromagnetic Offline Follow-Up of Ligo-Virgo Gravitational-Wave Binary Coalescence Candidate Events

We present two different search methods for electromagnetic counterparts to gravitational-wave (GW) events from ground-based detectors using archival NASA high-energy data from the Fermi Gamma-ray Burst Monitor (GBM) and RXTE All-sky Monitor (ASM) instruments. To demonstrate the methods, we use a limited number of representative GW background noise events produced by a search for binary neutron star coalescence over the last two months of the LIGO-Virgo S6/VSR3 joint science run. Time and sky location provided by the GW data trigger a targeted search in the high-energy photon data. We use two custom pipelines: one to search for prompt gamma-ray counterparts in GBM, and the other to search for a variety of X-ray afterglow model signals in ASM. We measure the efficiency of the joint pipelines to weak gamma-ray burst counterparts, and a family of model X-ray afterglows. By requiring a detectable signal in either electromagnetic instrument coincident with a GW event, we are able to reject a large majority of GW candidates. This reduces the signal-to-noise ratio of the loudest surviving GW background event by around 15-20 percent.

gamma-ray burst: general↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the power spectra of the wind-fed X-ray binary pulsar GX 301 - 2

A phenomenological model of accretion which is applied to the wind-fed X-ray binary pulsar GX 301 - 2 is developed, assuming that the accretion onto the neutron star does not occur from a continuous flux of plasma, but from blobs of matter which are threaded by the magnetic field lines onto the magnetic polar caps of the neutron star. These 'lumps' are produced at the magnetospheric limit by magnetohydrodynamical instability, introducing a 'noise' in the accretion process, due to the discontinuity in the flux of matter onto the neutron star. This model is able to describe the change of slope observed in the continuum component of the power spectra of the X-ray binary pulsar GX 301 - 2, in the frequency range 0.01 - 0.1 Hz. The physical properties of the infalling blobs derived in the model are in agreement with the constraints imposed by observations.

Orlandini, Mauro↗

TRINIDI: Time-of-Flight Resonance Imaging With Neutrons for Isotopic Density Inference

Accurate reconstruction of 2D and 3D isotope densities is a desired capability with great potential impact in applications such as evaluation and development of next-generation nuclear fuels. Neutron time-of-flight (TOF) resonance imaging offers a potential approach by exploiting the characteristic neutron absorption spectra of each isotope. However, it is a major challenge to compute quantitatively accurate images due to a variety of confounding effects such as severe Poisson noise, background scatter, beam non-uniformity, absorption non-linearity, and extended source pulse duration. We present the TRINIDI algorithm which is based on a two-step process in which we first estimate the neutron flux and background counts, and then reconstruct the areal densities of each isotope and pixel. Both components are based on the inversion of a forward model that accounts for the highly non-linear absorption, energy-dependent emission profile, and Poisson noise, while also modeling the substantial spatio-temporal variation of the background and flux. Further, to do this, we formulate the non-linear inverse problem as two optimization problems that are solved in sequence. We demonstrate on both synthetic and measured data that TRINIDI can reconstruct quantitatively accurate 2D views of isotopic areal density that can then be reconstructed into quantitatively accurate 3D volumes of isotopic volumetric density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron calorimeter development at fission and fusion pulsed neutron sources

A neutron calorimeter fielded in pulsed neutron irradiation experiments at the National Ignition Facility (NIF) and White Sands Missile Range Fast Burst Reactor (WSMR FBR) is described, and results are provided and discussed. The calorimeter is modular in design to allow fielding of various neutron absorber materials and thicknesses, as well as use at both fission and fusion sources, all of which has been done. Neutron calorimeters designed for fission sources have been fielded at fusion sources as well, but these instances are not documented in available literature—making this work novel. The functional calorimeter consists of a neutron absorber and two sheathed, grounded thermocouples secured within a subassembly made of thermally insulating materials. This subassembly is placed into a sealed vessel for material and facility safety considerations. The device was fielded at NIF in four polar-direct-drive exploding pusher shots and eleven WSMR FBR pulses. Calorimeter data from NIF experiments show a discernable thermal response accredited to neutron heating within the first 10 s, but the data are dominated by noise from ambient X-ray heating after time = 10 s post-pulse. This response is highly consistent between shots and linearly related to incident neutron fluence and neutron absorber thickness. A temperature rise of 1.1E-2 K/(10 13 neutrons/cm 2 ) per millimeter of absorber thickness was determined for both 0.4 mm and 1 mm thick depleted uranium absorbers with linear best fit R 2 of 0.97 and 0.98 for each thickness and y-axis offsets of 8.8E-3 and 1.3E-2, respectively. WSMR FBR experiment data show a temperature rise of 6.2E-2 K/(10 13 neutrons/cm 2 ) with linear best fit R 2 of 0.14 and y-axis offset of 7.6E-3 for a calorimeter with a 1 mm thick enriched boron carbide ( 10 B 4 C) absorber, though it must be noted that device-to-device variability is significant at both facilities. So these data are also affected by noise on a similar timescale as at NIF, though the noise is significantly lesser in magnitude but oscillatory.

42 ENGINEERING↗

Monte-Carlo Neutrino Transport in Neutron Star Merger Simulations

Gravitational waves and electromagnetic signals from merging neutron star binaries provide valuable information about the the properties of dense matter, the formation of heavy elements, and high-energy astrophysics. To fully leverage observations of these systems, we need numerical simulations that provide reliable predictions for the properties of the matter unbound in these mergers. An important limitation of current simulations is the use of approximate methods for neutrino transport that do not converge to a solution of the transport equations as numerical resolution increases, and thus have errors that are impossible to quantify. Here, we report on a first simulation of a binary neutron star merger that directly solves the transport equations using Monte-Carlo techniques. We demonstrate that a computationally cheap Monte-Carlo transport can be implemented without ill effects from sampling noise. We apply Monte-Carlo transport to an unequal mass neutron star binary merger up to 5ms past merger, and report on the properties of the matter and neutrino outflows. Finally, we compare our results to the output of our best approximate `M1' transport scheme, demonstrating that an M1 scheme that carefully approximates the neutrino energy spectrum only leads to ~10% uncertainty in the composition and velocity of the ejecta, and ~20% uncertainty in the electron (anti)neutrino luminosities and energies. Here, the most significant disagreement found between M1 and Monte-Carlo results is a factor of ~2 difference in the luminosity of heavy-lepton neutrinos.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Grazing Incidence Optics for Neutron Imaging and Scattering

Because of their wave nature, thermal and cold neutrons can be reflected from smooth surfaces at grazing incidence angles, be reflected by multilayer coatings or be refracted at boundaries of different materials. The optical properties of materials are characterized by their refractive indices which are slightly less than unity for most elements and their isotopes in the case of cold and thermal neutrons as well as for x-rays. The motivation for the optics use for neutrons as well as for x-rays is to increase the signal rate and, by virtue of the optic's angular resolution, to improve the signal-to-noise level by reducing the background so the efficiency of the existing neutron sources use can be significantly enhanced. Both refractive and reflective optical techniques developed for x-ray applications can be applied to focus neutron beams. Typically neutron sources have lower brilliance compared to conventional x-ray sources so in order to increase the beam throughput the neutron optics has to be capable of capturing large solid angles. Because of this, the replicated optics techniques developed for x-ray astronomy applications would be a perfect match for neutron applications, so the electroformed nickel optics under development at the Marshall Space Flight Center (MSFC) can be applied to focus neutron beams. In this technique, nickel mirror shells are electroformed onto a figured and superpolished nickel-plated aluminum cylindrical mandrel from which they are later released by differential thermal contraction. Cylindrical mirrors with different diameters, but the same focal length, can be nested together to increase the system throughput. The throughput can be increased further with the use of the multilayer coatings deposited on the reflectivr surface of the mirror shells. While the electroformed nickel replication technique needs to be adopted for neutron focusing, the technology to coat the inside of cylindrical mirrors with neutron multilayers has to be developed. The availability of these technologies would bring new capabilities to neutron instrumentation and, hence, lead to new scientific breakthroughs. We have established a program to adopt the electroformed nickel replication optics technique for neutron applications and to develop the neutron multilayer replication technology.

Gubarev, M. V.↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Impact of O4 future detections on the determination of the dense matter equations of state

Here, in view of the next LIGO-Virgo-KAGRA Observing period O4 (to start in Spring 2023), we address the question of the ability of the interferometers network to discriminate among different neutron stars equation of states better than what was possible with the observation of the binary neutron stars merger GW170817. We show that the observation of an event similar to GW170817 during O4 would allow us to resolve the dimensionless effective tidal deformability $\tilde{Λ}$ within an uncertainty 7 times better than the one obtained in O2. Thanks to the expected increase in sensitivities, we show that any GW170817-like single-event within a distance of 100 Mpc would imply significantly improved constraints of the neutron stars equations of state. We also illustrate the important impact of the noise in the analysis of the signal, showing how it can impact the effective tidal deformability probability density function for large signal-to-noise ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Sensors for Monitoring Gamma and Neutron Radiation

For safety and efficiency, nuclear reactors must be carefully monitored to provide feedback that enables the fission rate to be held at a constant target level via adjustments in the position of neutron-absorbing rods and moderating coolant flow rates. For automated reactor control, the monitoring system should provide calibrated analog or digital output. The sensors must survive and produce reliable output with minimal drift for at least one to two years, for replacement only during refueling. Small sensor size is preferred to enable more sensors to be placed in the core for more detailed characterization of the local fission rate and fuel consumption, since local deviations from the norm tend to amplify themselves. Currently, reactors are monitored by local power range meters (LPRMs) based on the neutron flux or gamma thermometers based on the gamma flux. LPRMs tend to be bulky, while gamma thermometers are subject to unwanted drift. Both electronic reactor sensors are plagued by electrical noise induced by ionizing radiation near the reactor core. A fiber optic sensor system was developed that is capable of tracking thermal neutron fluence and gamma flux in order to monitor nuclear reactor fission rates. The system provides near-real-time feedback from small- profile probes that are not sensitive to electromagnetic noise. The key novel feature is the practical design of fiber optic radiation sensors. The use of an actinoid element to monitor neutron flux in fiber optic EFPI (extrinsic Fabry-Perot interferometric) sensors is a new use of material. The materials and structure used in the sensor construction can be adjusted to result in a sensor that is sensitive to just thermal, gamma, or neutron stimulus, or any combination of the three. The tested design showed low sensitivity to thermal and gamma stimuli and high sensitivity to neutrons, with a fast response time.

Boyd, Clark D.↗