Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NbS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Dimensional stability of fused silica and several ultralow expansion materials

Description of a program of measurements of the dimensional stability of fused silica and several ultralow thermal expansion materials. The two techniques used are: (1) Fizeau interferometry employed by NBS-Corning, and (2) Fabry-Perot interferometry employed by the Optical Science Center, University of Arizona. In the latter, a measurement accuracy of one part in a billion is sought.

Jacobs, S. F.↗

Resonance lines of Cs II, Ba III, and La IV

The resonance line spectra of ions in the Xe I isoelectronic sequence, consisting of the five transitions to the 5p6 150 ground state from levels with J = 1 in the 5p5 5d and 6s configurations, have been observed for Cs II, Ba III, and La IV. The observations were made with a sliding spark on the 10.7-m normal-incidence vacuum spectrograph at NBS. The resonance transitions from the 5p5 6d and 7s configurations were also observed for these ions, except for that from 5p5 6d 3P1 of Ba III. Several resonance transitions from higher nd and ns levels were also observed. Estimated values for the J = 1 levels of the 5p5 7s configuration of Ce V were obtained by extrapolation. The derived ionization energies in eV are Cs II 23.17(4), Ba III 35.79(6), La IV 45.95(6), Ce V 65.55(25).

Reader, J.↗

Unfolding first and second order diffracted radiation when using synchrotron radiation sources - A technique

A technique is presented of using a single calibrated XUV detector for radiometric measurements of synchrotron radiation after the radiation passes through a monochromator that produces a mixture of first- and second-order diffracted radiation. Irradiance measurements are made with the synchrotron source operating at two different energies for the orbiting electrons. The known change in the spectral distribution produced by the electron energy change is used to calculate the flux in both first and second order. The dependence of the precision of these determinations on the two detected currents and on the detector calibration at both first- and second-order wavelengths is calculated. Experimental results using the National Bureau of Standards synchrotron (SURF-I) are presented, and anticipated results for the new NBS electron storage ring (SURF-II) are calculated.

Saloman, E. B.↗

Low pressure radon diffusion - A laboratory study and its implications for lunar venting

Results of a study of radon migration through columns of fine particulate materials, at total pressures of 0.02-0.2 torr, are reported. Materials studied were: NBS Glass Spheres (SRM 1003), Emerson & Cuming Eccospheres (IG-101), activated coconut charcoal, Lipaci obsidian, and W-1 Standard Diabase. Rates of diffusion were used to derive heats of adsorption for radon on the materials tested. The most reliable values found clustered around 8-9 kcal/mole. These high heats of adsorption, if typical for most materials, combined with low percentages of radon emanation by lunar soils found by other researchers, imply that random walk diffusion will not be an important mechanism for redistributing the radon and the radon daughters produced in the lunar regolith. In particular, since random walk migration is not a sufficient mechanism to account for localized high concentrations of radon-222 and its daughter polonium-210 observed by the Apollo 15 and 16 command modules, an alternative mechanism is proposed, in which radon would be swept to the surface by other gases during intermittent venting events.

Friesen, L. J.↗

Scaled equation of state parameters for gases in the critical region

In the light of recent theoretical developments, the paper presents an accurate characterization of anomalous thermodynamic behavior of xenon, helium 4, helium 3, carbon dioxide, steam and oxygen in the critical region. This behavior is associated with long range fluctuations in the system and the physical properties depend primarily on a single variable, namely, the correlation length. A description of the thermodynamic behavior of fluids in terms of scaling laws is formulated, and the two successfully used scaled equations of state (NBS equation and Linear Model parametric equation) are compared. Methods for fitting both equations to experimental equation of state data are developed and formulated, and the optimum fit for each of the two scaled equations of the above gases are presented and the results are compared. By extending the experimental data for the above one-component fluids to partially miscible binary liquids, superfluid liquid helium, ferromagnets and solids exhibiting order-disorder transitions, the principle of universality is concluded. Finally by using this principle, the critical regions for nine additional fluids are described.

Sengers, J. M. H. L.↗

Studies on color-center formation in glass utilizing measurements made during 1 to 3 MeV electron irradiation

The coloring of NBS 710 glass was studied using a facility for making optical absorption measurements during and after electron irradiation. The induced absorption contains three Gaussian shaped bands. The color center growth curves contain two saturating exponential and one linear components. After irradiation the coloring decays can be described by three decreasing exponentials. At room temperature both the coloring curve plateau and coloring rate increases with increasing dose rate. Coloring measurements made at fixed dose rate but at increasing temperature indicate: (1) The coloring curve plateau decreases with increasing temperature and coloring is barely measurable near 400 C. (2) The plateau is reached more rapidly as the temperature increases. (3) The decay occurring after irradiation cannot be described by Arrhenius kinetics. At each temperature the coloring can be explained by simple kinetics. The temperature dependence of the decay can be explained if it is assumed that the thermal untrapping is controlled by a distribution of activation energies.

Swyler, K. J.↗

A simple laboratory method for determining ignitability of materials

A simple laboratory method for determining ignitability of materials is described. The apparatus consists of a Mellen high-flux heater capable of producing up to 13 W/sq cm heat flux, a Medtherm water-cooled radiometer for measuring heat flux, a mounting frame to hold all components in proper position, and specimen holders of the type used for the NBS smoke test. Time to ignition at different heat flux levels is recorded. Test results are presented for a variety of materials.

Hilado, C. J.↗

Two-way time transfers between NRC/NBS and NRC/USNO via the Hermes (CTS) satellite

At each station the differences were measured between the local UTC seconds pulse and the remote UTC pulse received by satellite. The difference between the readings, if station delays are assumed to be symmetrical, is two times the difference between the clocks at the two ground station sites. Over a 20-minute period, the precision over the satellite is better than 1 ns. The time transfer from NRC to the CRC satellite terminal near Ottawa and from NBS to the Denver HEW terminal was examined.

Costain, C. C.↗

Thermal performance modification of composite materials

This paper reports on an investigation of the concept of modifying the thermal performance of filled polymers through a minor compositional change (presently by coating the filler). The fire-safety of construction materials and the instability of solid rockets are used as examples. A theory is developed which shows that vast improvements are possible by controlling thermal conductivity. Experiments are described that show the weight loss and smoke density in the NBS smoke-density chamber of fiberglass-reinforced epoxy panels, and the instability trends of an AP-HTPB propellant fired in an L-Star rocket motor. The feasibility of tailoring thermal behavior to suit each particular need is demonstrated.

Ramohalli, K.↗

A study of the excitation and radiative decay of the 3s-prime 3D-0 and 3d 3D-0 levels of atomic oxygen

The absolute cross-sections for the excitation of the 989 A, 1027 A, 7990 A, 8446 A, 1.1287 micron and 1.3164 micron multiplets of atomic oxygen by electron impact dissociation of O2 are reported. The radiative branching ratios for these transitions are calculated from these results and compared with the NBS compilation of Wiese et al. (1966) and the recent theoretical calculations of Pradhan and Saraph (1977). The cascade models of O(+) radiative recombination and of electron-impact excitation of the O I(3S) state in the terrestrial airglow are discussed in the light of the laboratory measurements, and the effects of the resonant absorption of components of the lambda 989 A and lambda 1027 A multiplets by the Birge-Hopfield band system of N2 are investigated. This process is shown to depend sensitively on the N2 vibrational temperature and to cause characteristic changes in the OI EUV emission spectrum in auroras and in the sunlit F-region at high exospheric temperatures.

Zipf, E. C.↗

An Orbiting Standards Platform for communication satellite system RF measurements

The Orbiting Standards Platform (OSP) is a proposed satellite dedicated to performing RF measurements on space communications systems. It would consist of a quasi-geostationary spacecraft containing an ensemble of calibrated RF sources and field strength meters operating in several microwave bands, and would be capable of accurately and conveniently measuring critical earth station and satellite RF performance parameters, such as EIRP, gain, figure of merit (G/T), crosspolarization, beamwidth, and sidelobe levels. The feasibility and utility of the OSP concept has been under joint study by NASA, NBS, Comsat and NTIA. A survey of potential OSP users was conducted by NTIA as part of this effort. The response to this survey, along with certain trends in satellite communications system design, indicates a growing need for such a measurement service.

Wallace, R. G.↗

Two-Way Time Transfer via Geostationary Satellites NRC/NBS, NRC/USNO and NBS/USNO via Hermes and NRC/LPTF (France) via Symphonie

In most of the experiments, 1 pps pulses of the station atomic clocks were exchanged between the partners, and a cubic equation was fitted to the 1000 to 2000 second measurements. The equations were exchanged and substracted to obtain the time difference of the stations. The standard deviation in the fit of the equations varied, depending on conditions, from 1.5 ns to 16 ns. For the last month of the Hermes experiment, a 1 MHz signal was used, giving a standard deviation of 0.18 ns. The comparison of the time scales via satellite and via Loran-C (BIH Circular D) show clearly that some Loran-C links are very good, but that the NBS link varies by 1 micron s. Via the satellite the frequencies of the time scales can be compared with an accuracy of 2 x 10 to the minus 14 power.

Costain, C.↗

Semiconductor technology program. Progress briefs

The current status of NBS work on measurement technology for semiconductor materials, process control, and devices is reported. Results of both in-house and contract research are covered. Highlighted activities include modeling of diffusion processes, analysis of model spreading resistance data, and studies of resonance ionization spectroscopy, resistivity-dopant density relationships in p-type silicon, deep level measurements, photoresist sensitometry, random fault measurements, power MOSFET thermal characteristics, power transistor switching characteristics, and gross leak testing. New and selected on-going projects are described. Compilations of recent publications and publications in press are included.

Bullis, W. M.↗

Advanced resin systems for graphite epoxy composites

The value of resin/carbon fiber composites as lightweight structures for aircraft and other vehicle applications is dependent on many properties: environmental stability, strength, toughness, resistance to burning, smoke produced when burning, raw material costs, and complexity of processing. A number of woven carbon fiber and epoxy resin composites were made. The epoxy resin was commercially available tetraglycidylmethylene dianiline. In addition, composites were made using epoxy resin modified with amine and carboxyl terminated butadiene acrylonitrile copolymer. Strength and toughness in flexure as well as oxygen index flammability and NBS smoke chamber tests of the composites are reported.

Gilwee, W. J.↗

Summary of flight technology workshop on radiometric calibration

The conclusions and recommendations from a three-day NASA sponsored workshop to assess deficiencies and shortcomings of previously flown electro-optical space sensors are summarized. Space technologists for NASA, NOAA, DOD, and industry also developed recommendations for improving instrumentation and calibration technology. The conclusions reached include the fact that the past knowledge of in-orbit radiometric accuracy has been poor relative to available calibration standards, whereas stringent accuracy requirements for planned NASA programs will require significant SOA improvements. The Shuttle contamination environment may also compromise future sensor accuracy. A number of panel recommendations to improve in-orbit accuracy of future sensors will be summarized, including one to establish a set of National Standards for Remote Sensors at NBS as a basis for long term accuracy.

Dodgen, J. A.↗

A study of universal modulation techniques applied to satellite data collection

A universal modulation and frequency control system for use with data collection platform (DCP) transmitters is examined. The final design discussed can, under software/firmwave control, generate all of the specific digital data modulation formats currently used in the NASA satellite data collection service and can simultaneously synthesize the proper RF carrier frequencies employed. A novel technique for DCP time and frequency control is presented. The emissions of NBS radio station WWV/WWVH are received, detected, and finally decoded in microcomputer software to generate a highly accurate time base for the platform; with the assistance of external hardware, the microcomputer also directs the recalibration of all DCP oscillators to achieve very high frequency accuracies and low drift rates versus temperature, supply voltage, and time. The final programmable DCP design also employs direct microcomputer control of data reduction, formatting, transmitter switching, and system power management.

Source record↗

Working in space

The capabilities of the NASA Neutral Buoyancy Simulator (NBS) water tank test facility are described, with reference to the proving of crew-operated mechanisms incorporated by the Space Telescope (ST). There are 24 Orbital Replaceable Units which are subject to handling in space by suited crewmen of the Space Shuttle, the largest of which is comparable to a telephone booth and weighs over 700 lb. The water volume of the simulator is sufficient to accept a full-size mockup of the Space Shuttle cargo bay, in which all ST operations will be conducted. Early ST simulations tested the mechanisms which astronauts would operate during contingency operations. More recently, the simulation tasks have reflected maintenance objectives of ST orbital life prolongation. With the recent addition of a fully functional Remote Manipulator System and the Manned Maneuvering Unit, the simulator constitutes the most complete training ground for extravehicular activities extant.

Sanders, F. G.↗

Radiometry using synchrotron radiation

It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.

Saloman, E. B.↗