Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NUCLEAR MEDICINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mining for Metal–Organic Systems: Chemistry Frontiers of Th-, U-, and Zr-Materials

The conceptual framework presented in this Perspective overviews the design principles of innovative thorium-based materials that could address urgent needs of the medicinal, nuclear energy, and waste remediation sectors from the lens of zirconium and uranium analogs. We survey the intersections of Zr, Th, and U chemistry with a focus on how the intrinsic behavior of each metal translates to broader material properties, including, but not limited to, structural and topological diversity, preferential metal–ligand binding, and reactivity. On the example of several classes of materials, including organometallic complexes, polyoxometalates, and the primary focus of this Perspective, metal–organic frameworks (MOFs), the design principles that govern the preparation of Zr-, Th-, and U-compounds, including oxophilicity, variation in oxidation states, and stable coordination environments have been considered. Further, we highlight how the impact of the mentioned variables may shift throughout the progression from discrete molecular systems to extended structures. We discuss the common assumption that zirconium-organic materials are typically considered a close analog of thorium-based congeners in areas such as material design and preparation. Through consideration of fundamental chemistry principles, we shed light on the relationships between Zr-, Th-, and U-based materials and highlight how a critical analysis of their distinct properties can be used to target a desired material performance. Finally, we provide a detailed understanding of Th-based materials chemistry by anchoring their fundamental properties between two well-studied reference points, zirconium- and uranium-containing analogs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production Pathways for Medically Interesting Isotopes

Radioisotopes are commonly used in nuclear medicine for treating cancer and new, more effective treatment options are always desired. As a result, there is a national need for new radioisotopes and ways to produce them. A computer program was created that evaluates the daughters for all known reactions of projectiles (gamma rays, protons or neutrons) with every stable target isotope by comparing the cross-sections for each reaction at a desired energy, and outputs a list of the potential daughter isotopes that are most likely to be generated. The program then evaluates the decay chains of these daughters to provide a list of the possible decay chains that contain the radioisotope of interest. By knowing the daughter production and decay chain for each isotope, it is possible to go from the desired radioisotope to the stable isotope that can be used as a target for its production. This project would facilitate the search for new pathways to creating useful theranostic isotopes.

Hutton, A.↗

Production of Radiohalogens: Bromine and Astatine for Imaging and Therapy

Objective: This collaborative proposal between the University of Alabama at Birmingham (UAB), University of Wisconsin, Madison (UWisc) and the University of Pennsylvania (Penn) aims to research the efficient production of high purity, clinical grade radiohalogens for preclinical and translational applications by optimizing the cyclotron targetry and separation chemistry of 76,77Br and 211At for use in imaging and therapy. Proposed Research and Methods: During the course of this project, faculty and trainees at our three institutions will use the complementary infrastructure available to examine the 76Se(p,n)76Br, 77Se(p,n)77Br, 78Se(p,2n)77Br, natAs(α,2n)77Br ,80Kr(p,α)77Br and 209Bi(α, 2n)211At reactions as routes to the production of these valuable radiohalogens for imaging and therapy. Working together we aim to optimize both solid and gas targetry, including reclamation of expensive enriched material. We will develop high yielding recovery processes based on dry distillation and ion exchange techniques. We will also create a comprehensive set of quality control procedures to ensure we are producing our radioisotopes in the highest radiochemical and chemical purity possible. By bringing three institutions together to perform research and development we provide the unique opportunity to build an everlasting cooperative culture in the field of nuclear medicine research by enabling academic centers to delve into the fields of radiohalogen chemistry. In addition, each institution involved holds different skills and expertise and a collaborative grant will facilitate the cross-pollination of ideas, techniques, and build strong bonds that unite under the DOE mission. Additionally, our work does not stop at the completion of this proposal, rather this proposal allows us to gain the momentum needed to get our research and developmental efforts off the ground thereby creating a network of three institutions dedicated to the advancement of isotope production for medical research.

07 ISOTOPE AND RADIATION SOURCES↗

Application of Monte Carlo Algorithms to Cardiac Imaging Reconstruction

Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One ofthe main limitations of myocardial perfusion imaging (MPI) is the effective mitigation of the scattering component,which is particularly challenging in Single Photon Emission Computed Tomography (SPECT). In SPECT,no timing information can be retrieved to locate the primary source photons. Monte Carlo methods allow anevent-by-event simulation of the scattering kinematics, which can be incorporated into a model of the imagingsystem response. This approach was adopted in the late Nineties by several authors, and recently took advantageof the increased computational power made available by high-performance CPUs and GPUs. These recent developmentsenable a fast image reconstruction with improved image quality, compared to deterministic approaches.Deterministic approaches are based on energy-windowing of the detector response, and on the cumulative estimateand subtraction of the scattering component. In this paper, we review the main strategies and algorithms tocorrect the scattering effect in SPECT and focus on Monte Carlo developments, which nowadays allow the threedimensionalreconstruction of SPECT cardiac images in a few seconds.

Pharmacology & Pharmacy↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

The Evaluation of (1R,4R,7R,10R)-α,α′,α″,α‴-Tetramethyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic Acid (DOTMA) as a Chelator for Zirconium-89

Recently, macrocycles such as 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) have been observed to form zirconium-89 (89Zr: t½ = 78.4 h, β+: 22.8%, Eβ+max = 901 keV; EC: 77%, Eγ = 909 keV)-complexes with excellent in vivo stability. In this report, we describe (1R,4R,7R,10R)-α,α′,α″,α‴-tetramethyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTMA) as an 89Zr chelator. Using [89Zr]ZrCl4, [89Zr]Zr-DOTMA was prepared in 99% radiochemical yield and a molar activity of 1055 ± 6 MBq/µmol. In vitro studies revealed a LogP value of −2.97± 0.02 and a radiometal complex that was inert when challenged with 1000-fold excess EDTA or high concentrations of biologically relevant metal ions. Finally, biodistribution studies revealed that the radiometal complex demonstrated in vivo behavior that was like [89Zr]Zr-DOTA and superior to [89Zr]Zr-DFO. Despite these promising observations, the elevated temperature required to form the [89Zr]Zr-DOTMA complex and the lack of derivatives available for bioconjugation will require additional ligand engineering to improve its utility for future nuclear medicine applications.

Pandya, Darpan N. [Department of Radiology, Univer↗

A multiple-plate, multiple-pinhole camera for X-ray gamma-ray imaging

Plates with identical patterns of precisely aligned pinholes constitute lens system which, when rotated about optical axis, produces continuous high resolution image of small energy X-ray or gamma ray source. Camera has applications in radiation treatment and nuclear medicine.

Hoover, R. B.↗

A target design for irradiation of NaI at high beam current.

A solution to the targetry problems encountered when the iodine nucleus is a target for cyclotron irradiation is given as a new target design. A target based on this design has been used in 30 microampere irradiations of 46 MeV alpha particles for one-half hour without significant damage. Such an irradiation produces 6 to 7 mCi of Cs-129, an isotope useful in nuclear medicine. This target should also be considered for cyclotron production of the radioisotopes Cs-127, I-123, and Xe-127.

Blue, J. W.↗

Evaluation of nuclear-reactor-produced iodine-123

Iodine-123 has such great potential for nuclear medicine that all possible production methods should be considered. In this report, an experimental study related to I-123 production at a high-intensity fast-flux reactor using the reaction Xe-124(n,2n)Xe-123 is considered. The conclusion is that I-123 could be made in small quantities and the cost would be higher than the cyclotron methods presently used.

Blue, J. W.↗

Sealed high-pressure x-ray detector

Detector is filled to pressure of 2 atm with mixture of 95% xenon and 5% methane for recording hard x-ray (50-to100-keV0 images with spatial resolution of about 1 mm. Being sealed, detector requires no gas purification or replenishment after initial fill. Potential areas of application include nuclear medicine, and x-ray or gamma-ray astronomy.

Gorenstein, P.↗

Radiological health risks to astronauts from space activities and medical procedures

Radiation protection standards for space activities differ substantially from those applied to terrestrial working situations. The levels of radiation and subsequent hazards to which space workers are exposed are quite unlike anything found on Earth. The new more highly refined system of risk management involves assessing the risk to each space worker from all sources of radiation (occupational and non-occupational) at the organ level. The risk coefficients were applied to previous space and medical exposures (diagnostic x ray and nuclear medicine procedures) in order to estimate the radiation-induced lifetime cancer incidence and mortality risk. At present, the risk from medical procedures when compared to space activities is 14 times higher for cancer incidence and 13 times higher for cancer mortality; however, this will change as the per capita dose during Space Station Freedom and interplanetary missions increases and more is known about the risks from exposure to high-LET radiation.

Peterson, Leif E.↗

The Canadian experience: Using telemedicine for the support of medical care at remote sites

While the majority of Canadians live in a narrow strip about 200 miles wide just north of the 45th parallel, a significant proportion of the population lives in non-urban, remote and sometimes isolated areas. Given this widely dispersed population, the provision of health services has always been a challenge. A list of non-urban health needs include the following: consulting services; clinical laboratory resources; investigative techniques (e.g., EEG, radiology, ultrasound, nuclear medicine); continuing education for physicians, nurses and other health professionals; teaching and training programs for administrative and support staff (dietary, housekeeping, maintenance); community health education and improved general education for health workers and families. For nearly three decades physicians and other health care professionals in the United States and Canada have been exploring the application of telecommunications to health care in rural and remote areas. The terms telemedicine and telehealth are used interchangeably to describe this activity. The prefix 'tele' refers to distance and now includes all types of communication over distance that support health care and health educational programs. Actually, telemedicine is as old as the telephone, which is still the most widely used communications technology in health care.

House, Maxwell↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occuring during the readout window.

Lacy, Jeffrey L.↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occurring during the readout window.

Lacy, Jeffrey L.↗

Fabricating High-Resolution X-Ray Collimators

A process and method for fabricating multi-grid, high-resolution rotating modulation collimators for arcsecond and sub-arcsecond x-ray and gamma-ray imaging involves photochemical machining and precision stack lamination. The special fixturing and etching techniques that have been developed are used for the fabrication of multiple high-resolution grids on a single array substrate. This technology has application in solar and astrophysics and in a number of medical imaging applications including mammography, computed tomography (CT), single photon emission computed tomography (SPECT), and gamma cameras used in nuclear medicine. This collimator improvement can also be used in non-destructive testing, hydrodynamic weapons testing, and microbeam radiation therapy.

Appleby, Michael↗

Hubble Systems Optimize Hospital Schedules

Don Rosenthal, a former Ames Research Center computer scientist who helped design the Hubble Space Telescope's scheduling software, co-founded Allocade Inc. of Menlo Park, California, in 2004. Allocade's OnCue software helps hospitals reclaim unused capacity and optimize constantly changing schedules for imaging procedures. After starting to use the software, one medical center soon reported noticeable improvements in efficiency, including a 12 percent increase in procedure volume, 35 percent reduction in staff overtime, and significant reductions in backlog and technician phone time. Allocade now offers versions for outpatient and inpatient magnetic resonance imaging (MRI), ultrasound, interventional radiology, nuclear medicine, Positron Emission Tomography (PET), radiography, radiography-fluoroscopy, and mammography.

Source record↗

Chelating platform for delivery of radionuclides

Siderocalin-metal chelator combinations that bind metallic radioisotopes used in nuclear medicine with high affinity are described. The high affinity siderocalin-metal chelator combinations include a number of chelator backbone arrangements with functional groups that coordinate with metals. The siderocalin-metal chelator combinations can be used to deliver radionuclides for imaging and therapeutic purposes.

Strong, Roland K.↗