Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOBLE METAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Zero-Valent Metallic Treatment System and Its Application for Removal and Remediation of Polychlorinated Biphenyls (Pcbs)

PCBs are removed from contaminated media using a treatment system including zero-valent metal particles and an organic hydrogen donating solvent. The treatment system may include a weak acid in order to eliminate the need for a coating of catalytic noble metal on the zero-valent metal particles. If catalyzed zero-valent metal particles are used, the treatment system may include an organic hydrogen donating solvent that is a non-water solvent. The treatment system may be provided as a "paste-like" system that is preferably applied to natural media and ex-situ structures to eliminate PCBs.

Quinn, Jacqueline W.↗

Tunable Optical Properties of Metal Nanoparticle Sol-Gel Composites

We demonstrate that the linear and non-linear optical properties of sol-gels containing metal nanoparticles are highly tunable with porosity. Moreover, we extend the technique of immersion spectroscopy to inhomogeneous hosts, such as aerogels, and determine rigorous bounds for the average fractional composition of each component, i.e., the porosity of the aerogel, or equivalently, for these materials, the catalytic dispersion. Sol-gels containing noble metal nanoparticles were fabricated and a significant blue-shift in the surface plasmon resonance (SPR) was observed upon formation of an aerogel, as a result of the decrease in the dielectric constant of the matrix upon supercritical extraction of the solvent. However, as a result of chemical interface damping and aggregation this blue-shift does not strictly obey standard effective medium theories. Mitigation of these complications is achieved by avoiding the use of alcohol and by annealing the samples in a reducing atmosphere.

Smith, David D.↗

Increasing Durability of Flame-Sprayed Strain Gauges

Thermally sprayed dielectric ceramic coatings are the primary means of attaching strain and temperature gauges to hot-section rotating parts of turbine engines. As hot-section temperatures increase, lifetimes of installed gauges decrease, and seldom exceed one hour above 2,000 F (approx.1,100 C). Advanced engine components are expected to operate at temperatures approaching 2,200 F (approx.1,200 C), and the required high-temperature lifetime is 10 hours minimum. Typically, to enable a ceramic coating to adhere to the smooth surface of an engine component, a thermally sprayed NiCrAlY or NiCoCrAlY bond coat is applied to the smooth surface, thereby providing a textured surface to which the ceramic coat can adhere. The main failure mechanism of this system is decohesion and/or delamination at the interface between the ceramic top coat and the bond coat, caused by oxidation of the bond coat and stresses from the mismatch between the coefficients of thermal expansion of the ceramic top coat and the metallic bond coat. The approach taken to increase the high-temperature lifetime of a gauge attached to an engine component by the method described above involves (1) selective oxidation of the bond coat by means of a heat treatment in reduced oxygen partial pressure followed by (2) the application of a noble-metal diffusion barrier. In experiments to test this approach, heat treatments of NiCoCrAlY bond coats were carried out in a tube furnace in which, in each case, the temperature was alternately (1) increased at a rate of 3 C per minute and (2) held steady for one hour until the desired temperature was reached. The tube furnace was continuously purged with dry nitrogen gas. A final heat-treatment temperature range of 1,600 to 1,800 F (871 to 982 C) proved most beneficial.

Gregory, Otto J.↗

Several new catalysts for reduction of oxygen in fuel cells

Test results prove nickel carbide or nitride, nickel-cobalt carbide, titanium carbide or nitride, and intermetallic compounds of the transition or noble metals to be efficient electrocatalysts for oxygen reduction in alkaline electrolytes in low temperature fuel cells.

Cattabriga, R. A.↗

High-temperature ceramic-to-ceramic seals

Noble-metal braze applied to appropriately prepared zirconia parts produces a gas-tight, durable seal that can withstand temperature of 825 C for over 2000 hours without deterioration.

Smart, W.↗

Technology Development of a Biowaste Resistojet, Volume 2

The thruster development effort of the biowaste resistojet program is reported. Under this program, several variations of the concentric tube resistojet were built and tested. Because of the corrosive nature of the biowaste gases available for propellants, thruster effort was concentrated on the use of noble metals (platinum and its alloys) for the critical center tube heating element. This tube must operate at high temperatures. Initially the biowaste gases were projected to be CO2, CH4, H2O or H2 with only very small amounts of O2 or N2. However, during 1971, results from experimental life support tests indicated that the oxygen content would probably be in the range from 0.5 to 1.0%. To achieve the desired high specific impulses, metal temperatures as high as 1700 K (3060 R) were considered desirable goals. The first thruster, designated Mark 1, employed the alloy platinum-rhodium for the center tube. Although this material was oxidation resistant and had high strength relative to pure platinum, experimental materials tests showed that this alloy suffered from carbonyl reactions when tested on pure CO2. These reactions resulted in a depletion of rhodium and significantly weakened the tubes. The next series of thrusters were designated Mark 2 and employed platinum-iridium for the center tubes.

Phillips, D. G.↗

Bacteria detection instrument and method

A method and apparatus for screening a sample fluid for bacterial presence are disclosed wherein the fluid sample is mixed with culture media of sufficient quantity to permit bacterial growth in order to obtain a test solution. The concentration of oxygen dissolved in the test solution is then monitored using the potential difference between a reference electrode and a noble metal electrode which are in contact with the test solution. The change in oxygen concentration which occurs during a period of time as indicated by the electrode potential difference is compared with a detection criterion which exceeds the change which would occur absent bacteria.

Renner, W.↗

Catalytic oxidation of trace levels of methane in oxygen in a tubular reactor

An experimental investigation of catalytic oxidation of trace levels of methane in oxygen was conducted in a tubular reactor. Two noble metal solid catalysts were explored: a 1-percent platinum on gamma alumina and a 0.5-percent rhodium on gamma alumina. For each catalyst the activity was determined as a function of temperature, pressure, space velocity, and methane concentration. The rhodium catalyst was considerably more active than the platinum catalyst. For each catalyst mass transfer had a pronounced effect upon activity at low space velocity.

Warshay, M.↗

Preliminary results from screening tests of commercial catalysts with potential use in gas turbine combustors. Part 1: Furnace studies of catalyst activity

Thirty commercially produced monolith and pellet catalysts were tested as part of a screening process to select catalysts suitable for use in a gas turbine combustor. The catalysts were contained in a 1.8 centimeter diameter quartz tube and heated to temperatures varying between 300 and 1,200 K while a mixture of propane and air passed through the bed at space velocities of 44,000 to 70,000/hour. The amount of propane oxidized was measured as a function of catalyst temperature. Of the samples tested, the most effective catalysts proved to be noble metal catalysts on monolith substrates.

Anderson, D. N.↗

Preliminary results from screening tests of commercial catalysts with potential use in gas turbine combustors. I - Furnace studies of catalyst activity

Thirty commercially produced monolith and pellet catalysts were tested as part of a screening process to select catalysts suitable for use in a gas turbine combustor. The catalysts were contained in a 1.8 centimeter diameter quartz tube and heated to temperatures varying between 300 and 1200 K while a mixture of propane and air passed through the bed at space velocities of 44,000 to 70,000 per hour. The amount of propane oxidized was measured as a function of catalyst temperature. Of the samples tested, the most effective catalysts proved to be noble metal catalysts on monolith substrates.

Anderson, D. N.↗

Emissions and performance of catalysts for gas turbine catalytic combustors

Three noble-metal monolithic catalysts were tested in a 12-centimeter diameter combustion test rig to obtain emissions and performance data at conditions simulating the operation of a catalytic combustor for an automotive gas turbine engine. Tests with one of the catalysts at 800 K inlet mixture temperature 300,000 pa (3 atm) pressure, and a reference velocity (catalyst bed inlet velocity) of 10 m/sec demonstrated greater than 99 percent combustion efficiency for reaction temperatures higher than 1300 K. With a reference velocity of 25 m/sec the reaction temperature required to achieve the same combustion efficiency increased to 1380 K. The exit temperature pattern factors for all three catalysts were below 0.1 when adiabatic reaction temperatures were higher than 1400 K. The highest pressure drop was 4.5 percent at 25 m/sec reference velocity. Nitrogen oxides emissions were less than 0.1 g NO2/kg fuel for all test conditions.

Anderson, D. N.↗

Emissions and performance of catalysts for gas turbine catalytic combustors

Three noble-metal monolithic catalysts were tested in a 12-cm-dia. combustion test rig to obtain emissions and performance data at conditions simulating the operation of a catalytic combustor for an automotive gas turbine engine. Tests with one of the catalysts at 800 K inlet mixture temperature, 3 x 10 to the 5th Pa pressure, and a reference velocity (catalyst bed inlet velocity) of 10 m/sec demonstrated greater than 99 percent combustion efficiency for reaction temperatures higher than 1300 K. With a reference velocity of 25 m/sec the reaction temperature required to achieve the same combustion-efficiency increased to 1380 K. The exit temperature pattern factors for all three catalysts were below 0.1 when adiabatic reaction temperatures were higher than 1400 K. The highest pressure drop was 4.5 percent at 25 m/sec reference velocity. Nitrogen oxides emissions were less than 0.1 g NO2/kg fuel for all test conditions.

Anderson, D. N.↗

Inverse isotope effect and the x dependence of the superconducting transition temperature in PdHx and PdDx

First-principles electron-band-structure calculations and measured phonon properties are employed in a calculation of the concentration dependence of the superconducting transition temperatures for PdHx and PdDx, including the inverse isotope effect. Excellent agreement with the experimental results is obtained. Our model also gives a qualitative understanding of the enhanced transition temperatures in the palladium-noble-metal hydrides.

Klein, B. M.↗

Investigation of low temperature carbon monoxide oxidation catalysts

Carbon monoxide generation rates related to the use of commerical equipment in Spacelab, added to the normal metabolic and subsystem loads, will produce carbon monoxide levels in excess of the maximum allowable concentration. In connection with the sensitivity of carbon monoxide oxidation catalysts to poisoning at room temperature, catalysts for an oxidation of carbon monoxide at low temperatures have been investigated. It was found that platinum and palladium are the only effective room temperature catalysts which are effective at 333 K. Hopcalite was ineffective at ambient temperatures, but converted CO with 100 percent efficiency at 333 K. Poisoning tests showed the noble metal catalysts to be very sensitive, and Hopcalite to be very resistant to poisoning.

Jagow, R. B.↗