Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIR imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development and test of an IR camera for astronomical observation at the Palomar 200-in. observatory using the NICMOS II array

A NICMOS II array, a NIR (0.80 - 2.6 micron) imaging system, was integrated into the California Institute of Technology Palomar Observatory camera. The Palomar camera system which consists of six discrete subsystems including a focal plane, an electrical interface, data acquisition electronics, a dewar, dewar optics, and the software is described. The performance and calibration data for each subsystem are presented. Emphasis is placed on test data on the focal plane performance.

Bruce, Carl↗

First Stars and Galaxies, the Roadmap Ahead: Observation

A complete observational understanding of the first stars and galaxies will require four facilities: JWST, 30m ground-based telescopes, ALMA, and the SKA. Each provides complementary capabilities. JWST is our best hope for looking to very high redshift. 30m-class ground-based telescopes provide sensitivity to the rest-frame ultraviolet with high-resolution imaging and high-resolution NIR spectroscopy, possibly reaching as far as z approx.15. They will also allow us to study stellar populations in nearby galaxies and examine the fossil record of the first stars. ALMA will image the redshifted dust continuum emission from evolving galaxies out to z approx.10. The SKA will do cosmic tomography, mapping the process of reionization.

Gardner, Jonathan P.↗

Imaging system and method for enhanced visualization of near surface vascular structures

A sub-dermal structure visualization system and method is disclosed. The system may use an illumination module including: a near-infrared (NIR) light source adapted to substantially uniformly illuminate an imaged area including sub-dermal regions thereof with NIR light; and a first optical system including at least one optical element for controlling at least one of spectral and polarization properties of the NIR light prior to illuminating the imaged area. An imaging module rejects unwanted signals from an imaged area while passing desired optical signals that are to be received by an image acquisition module. The desired optical signals can comprise a vein visualization signal to assist in visualizing a vascular structure below a skin layer of a patient.

Demos, Stavros G.↗

Superconducting nanowire single-photon detector enhanced near-infrared II portable confocal microscopy for tissue imaging with indocyanine green

In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.

Liu, Yifan (ORCID:0000000328877704)↗

New optical approaches to the quantitative characterization of crystal growth, segregation and defect formation

Elemental and compound semiconductors were characterized using new optical approach based on NIR microscopy in conjunction with computational image analysis and contrast enhancement. The approach made it possible to perform a quantitative microsegregation analysis of GaAs and InP. NIR dark file illumination in transmission mode makes it possible to detect submicron precipitates in semiinsulating GaAs.

Carlson, D. J.↗

Development of High Performance Detector Technology for UV and Near IR Applications

Sensing and imaging for ultraviolet (UV) and nearinfrared (NIR) bands has many applications forNASA, defense, and commercial systems. Recentwork has involved developing UV avalanchephotodiode (UV-APD) arrays with high gain for highresolution imaging. Various GaN/AlGaN p-i-n (PIN)UV-APDs have been fabricated from epitaxialstructures grown by MOCVD on GaN substrates withavalanche gains higher than 5 x 10(exp 5), and significantlyhigher responsivities. Likewise, the SiGe materialsystem allows the demonstration of high-performancedetector array technology that covers the 0.5 to 1.7 mwavelength range for visible and NIR bands ofinterest. We have utilized SiGe fabrication technologyto develop Ge based PIN detector devices on 300 mmSi wafers. We will discuss the theoretical andexperimental results from electrical and opticalcharacterization of the detector devices with variousn+ region doping concentrations to demonstrate low dark currents below 1 uA at -1 V and high photocurrent. Recent results from these detectorarrays for UV and NIR detection will be presented.

IR↗

Estimating Major Ion and Nutrient Concentrations in Mangrove Estuaries in Everglades National Park Using Leaf and Satellite Reflectance

Coastal mangrove ecosystems are under duress worldwide because of urban development, sea-level rise, and climate change, processes that are capable of changing the salinity and nutrient concentration of the water utilized by the mangroves. This study correlates long-term water chemistry in mangrove environments, located in Everglades National Park,with mangrove spectral reflectance measurements made at both the leaf and canopy scales. Spectral reflectance measurements were collected using a handheld spectrometer for leaf-level measurements and Landsat 5TMdata for regional coverage. Leaf-level reflectance data were collected from three mangrove species (i.e., red, black and white mangroves) across two regions; a tall mangrove (approximately 18m) and dwarf mangrove (1- 2 m) region. The reflectance data were then used to calculate a wide variety of biophysical reflectance indices (e.g., NDVI, EVI, SAVI) to determine signs of stress. Discrete, quarterly water samples from the surface water, groundwater, and pore water (20 and 85 cm depths) and daily autonomous surface water samples were collected at each site and analyzed for major anions (Cl(−) and SO(2(-)/4)), cations (Na(+), K(+), Mg(sup 2(+)), and Ca(sup 2(+)), total nitrogen (TN) and total phosphorus (TP).Mangrove sites that exhibited the highest salinity and ionic concentrations in the surface and subsurface water also had the lowest near-infrared reflectance at both the leaf and satellite levels. Seasonal reflectance responses were measured in the near-infrared (NIR) wavelengths at both the leaf and canopy scales and were strongly correlated with nutrient and ionic concentrations in the surface and subsurface water, even though there was no significant separability between the three mangrove species. Study sites that experienced the greatest variability in surface and subsurface water ionic concentrations also exhibited the greatest fluctuations in NIR spectral reflectance. Landsat 5TM images were able to detect tall and dwarf mangroves by the differences in spectral indices (e.g., NDVI, NDWI, and EVI) because of the variability in the background conditions amongst the environments. In addition, Landsat 5TM images spanning 16 years (1993- 2009) were successfully used to estimate the seasonal variability in ionic concentrations in the surface water across the Florida Coastal mangrove ecotone. This study has shown that water chemistry can be estimated indirectly by measuring the change in spectral response at the leaf- or satellite-scale. Furthermore, the results of this research may be extrapolated to similar coastal mangrove systems throughout the Caribbean and world-wide wherever red, black, and white mangroves occur.

Mangroves↗

High Throughput, High Yield Fabrication of High Quantum Efficiency Back-Illuminated Photon Counting, Far UV, UV, and Visible Detector Arrays

In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).

spectroscopy↗

SPRUCE Experimental Plot Top View Aerial Images beginning June 2019

This data set provides a record of the aerial images of the SPRUCE experimental plots obtained periodically using an unmanned aerial vehicle (UAV) with attached camera from 2019-05-05- to 2022-08-25. New images of the plots will be added periodically. The initial RGB images may be used for studies of greenness and snow coverage and compared with ground-based measurements and chamber-based tree and shrub Phenocam images (e.g. Schädel et al., 2022). Also included are NDVI (Normalized Difference Vegetation Index) images showing calculated difference between visible near-infrared (NIR) light reflectance from vegetation, as well as infrared (IR) and multispectral images. Files are presented in JPEG (*.jpg) or PDF (*.pdf) format inside of 28 compressed (*.zip) files. Images were collected for the 10 plots with enclosures, the 7 unchambered plots, and the environmental monitoring instrument cluster area. Images are slightly off-plot center at 12 to 15 meters above ground level or approximately 2 meters above the top of an experimental chamber.

54 ENVIRONMENTAL SCIENCES↗

Circumnuclear pileups of dust and gas in M82

Red H-alpha and R-band CCD images of the M82 galaxy were obtained and compared with corresponding NIR S III forbidden-line and I-band images and with a smaller Br-gamma infrared-array image of the central 500 pc. Results furnish evidence of circumnuclear pileup in M82, probably toroidal in form, which is dynamically linked to the central (bilobal) starburst and which is now collimating the subsequent eruptions and emergent radiation.

Waller, William H.↗

Bright NIR‐II Photoluminescence in Rod‐Shaped Icosahedral Gold Nanoclusters

Abstract Fluorophores with high quantum yields, extended maximum emission wavelengths, and long photoluminescence (PL) lifetimes are still lacking for sensing and imaging applications in the second near‐infrared window (NIR‐II). In this work, a series of rod‐shaped icosahedral nanoclusters with bright NIR‐II PL, quantum yields up to ≈ 8%, and a peak emission wavelength of 1520 nm are reported. It is found that the bright NIR‐II emission arises from a previously ignored state with near‐zero oscillator strength in the ground‐state geometry and the central Au atom in the nanoclusters suppresses the non‐radiative transitions and enhances the overall PL efficiency. In addition, a framework is developed to analyze and relate the underlying transitions for the absorptions and the NIR‐II emissions in the Au nanoclusters based on the experimentally defined absorption coefficient. Overall, this work not only shows good performance of the rod‐shaped icosahedral series of Au nanoclusters as NIR‐II fluorophores, but also unravels the fundamental electronic transitions and atomic‐level structure‐property relations for the enhancement of the NIR‐II PL in gold nanoclusters. The framework developed here also provides a simple method to analyze the underlying electronic transitions in metal nanoclusters.

Li, Qi↗

Using DSCOVR EPIC as an Additional Calibration Reference to Radiometrically Scale the Geo Imagers for the NASA CERES Project

The NASA CERES project provides climate-quality observed TOA and calculated surface fluxes to the climate community. The CERES instruments are mounted on the Aqua, Terra, NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used alongside the VIIRS and MODIS based cloud properties necessary for converting CERES radiance observations into fluxes. The CERES SYN1deg product provides the regional hourly fluxes in between the Terra and Aqua/NOAA-20-CERES observations based on geostationary imager (GEO) radiances. The GEO radiances are radiometrically scaled to the MODIS or VIIRS calibration references. The GEO and MODIS inter-calibration events are limited by the Aqua-MODIS or VIIRS local equator crossing time of 1:30 PM. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth, and the Earth Polychromatic Imaging Camera (EPIC) instrument onboard DSCOVR has a constant view of the sunlit side of the Earth while taking images ranging from the UV to the NIR throughout the day. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that EPIC is radiometrically stable, which allows it to potentially be used as a transfer radiometer between imagers. This study will assess the viability of using EPIC as a consistent and stable calibration source for GEO imagers. EPIC will be inter-calibrated with Himawari-8 that has been radiometrically scaled with Aqua. The Himawari-8 based EPIC calibration gains will be verified by the EPIC calibration gains determined directly from Aqua-MODIS matches. The EPIC calibration gains based on Himawari-8 will be stratified by local time to determine any diurnal dependence of the GEO/EPIC calibration strategy.

C O Haney↗

VIIRS On-Orbit Optical Anomaly - Investigation, Analysis, Root Cause Determination and Lessons Learned

A gradual, but persistent, decrease in the optical throughput was detected during the early commissioning phase for the Suomi National Polar-Orbiting Partnership (SNPP) Visible Infrared Imager Radiometer Suite (VIIRS) Near Infrared (NIR) bands. Its initial rate and unknown cause were coincidently coupled with a decrease in sensitivity in the same spectral wavelength of the Solar Diffuser Stability Monitor (SDSM) raising concerns about contamination or the possibility of a system-level satellite problem. An anomaly team was formed to investigate and provide recommendations before commissioning could resume. With few hard facts in hand, there was much speculation about possible causes and consequences of the degradation. Two different causes were determined as will be explained in this paper. This paper will describe the build and test history of VIIRS, why there were no indicators, even with hindsight, of an on-orbit problem, the appearance of the on-orbit anomaly, the initial work attempting to understand and determine the cause, the discovery of the root cause and what Test-As-You-Fly (TAYF) activities, can be done in the future to greatly reduce the likelihood of similar optical anomalies. These TAYF activities are captured in the lessons learned section of this paper.

Iona, Glenn↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Leo Imagers to the Same Calibration Reference

The NASA CERES project provides climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used in tandem with the MODIS and VIIRS instruments to retrieve cloud properties required for converting CERES radiance observations into fluxes. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua-MODIS reference to retrieve consistent imager cloud properties between sensors. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun-synchronous orbit but spaced equally apart, allowing for no simultaneous nadir overpasses (SNO) to inter-calibrate the VIIRS imagers to each other. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between neither MODIS nor VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers. The study will demonstrate the use of EPIC to radiometrically scale VIIRS and MODIS imagers to the same Aqua-MODIS calibration reference. The EPIC-based NPP and N20-VIIRS scaling factors will be compared with the Aqua-MODIS based NPP and N20-VIIRS scaling factors.

C. O. Haney↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Multiple VIIRS Sensors Over Tropical Earth Views

The NASA CERES project provides Energy Balanced and Filled (EBAF) product climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 satellites. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua- MODIS reference to retrieve consistent imager cloud properties between sensors, which are used to retrieve cloud properties required for converting CERES radiance observations into fluxes. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun- synchronous orbit but spaced equally apart, which means that no simultaneous nadir overpasses (SNO) may be used to inter-calibrate the VIIRS imagers to each one another. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua-MODIS can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between either MODIS and or VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers and is especially suited for drifting orbits because EPIC imager frequently samples the Earth diurnally. The study will demonstrate the use of EPIC as a transfer radiometer to radiometrically scale the NPP and NOAA-20 VIIRS imagers. The scaling factors will be compared with the scaling factors using Aqua-MODIS as the transfer radiometer.

Conor Haney↗

Indefinite and bidirectional near-infrared nanocrystal photoswitching

Materials whose luminescence can be switched by optical stimulation drive technologies ranging from superresolution imaging, nanophotonics, and optical data storage, to targeted pharmacology, optogenetics, and chemical reactivity. Furthermore, these photoswitchable probes, including organic fluorophores and proteins, can be prone to photodegradation and often operate in the ultraviolet or visible spectral regions. Colloidal inorganic nanoparticles can offer improved stability, but the ability to switch emission bidirectionally, particularly with near-infrared (NIR) light, has not, to our knowledge, been reported in such systems. Here, we present two-way, NIR photoswitching of avalanching nanoparticles (ANPs), showing full optical control of upconverted emission using phototriggers in the NIR-I and NIR-II spectral regions useful for subsurface imaging. Employing single-step photodarkening and photobrightening, we demonstrate indefinite photoswitching of individual nanoparticles (more than 1,000 cycles over 7 h) in ambient or aqueous conditions without measurable photodegradation. Critical steps of the photoswitching mechanism are elucidated by modelling and by measuring the photon avalanche properties of single ANPs in both bright and dark states. Unlimited, reversible photoswitching of ANPs enables indefinitely rewritable two-dimensional and three-dimensional multilevel optical patterning of ANPs, as well as optical nanoscopy with sub-Å localization superresolution that allows us to distinguish individual ANPs within tightly packed clusters.

36 MATERIALS SCIENCE↗

A Near-Infrared (NIR) Global Multispectral Map of the Moon from Clementine

In May and June of 1994, the NASA/DoD Clementine Mission acquired global, 11- band, multispectral observations of the lunar surface using the ultraviolet-visible (UVVIS) and near-infrared (NIR) camera systems. The global 5-band UVVIS Digital Image Model (DIM) of the Moon at 100 m/pixel was released to the Planetary Data System (PDS) in 2000. The corresponding NIR DIM has been compiled by the U.S. Geological Survey for distribution to the lunar science community. The recently released NIR DIM has six spectral bands (1100, 1250, 1500, 2000, 2600, and 2780 nm) and is delivered in 996 quads at 100 m/pixel (303 pixels/degree). The NIR data were radiometrically corrected, geometrically controlled, and photometrically normalized to form seamless, uniformly illuminated mosaics of the lunar surface.

Eliason, E. M.↗