Effect of blade-tip crossover passages on natural-convection water-cooling of gas-turbine blades
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Flow visualization experiments in a Bridgman furnace at zero growth velocity have been performed. The experiments were intended to investigate if the photochromic dye activation method could be used in a crystal growth study. The results from this work have confirmed that with a carefully designed experimental setup, the photochromic-dye method permits qualitative and quantitative evaluation of the flow field near the interface in crystal growth experiments. For the horizontal orientation of a 6 mm x 6 mm ampoule and an axial temperature gradient of 26.5 C/cm, velocity profiles have been obtained accurately at various positions near the interface. The maximum velocity of 1.29 mm/sec was measured in the central vertical plane and the flow was symmetrical about that plane. A flow inversion point was also noted, above which the flow was towards the interface and below it, away from the interface. The results obtained are useful for validating 3-dimensional numerical models and establishing a link between the macroscopic processing conditions and the formation of crystalline defects.
The influence of Grashof and Reynolds number in Metal Organic Chemical Vapor (MOCVD) reactors is being investigated under a combined empirical/numerical study. As part of that research, the deposition of Indium Phosphide in an MOCVD reactor is modeled using the computational code CFD-ACE. The model includes the effects of convection, conduction, and radiation as well as multi-component diffusion and multi-step surface/gas phase chemistry. The results of the prediction are compared with experimental data for a commercial reactor and analyzed with respect to the model accuracy.
Parallel computation for two-dimensional convective flows in.
Parallel computation for thermal convective flows in cavities with adiabatic horizontal boundaries and driven by differential heating of the two vertical end walls, is investigated using supercomputers. A parallel computation code has been implemented using a finite-difference method with a multigrid elliptic solver and a Dufort-Frankel scheme. The domain decomposition techniques are discussed in detail. The parallel code is numerically stable, computationally efficient, and portable to various parallel architectures which support either PVM or NX libraries for communications. Finally, numerical results for various Rayleigh numbers and Prandtl numbers are presented.
Explore the source record for details and available documents.
A water based shielding system is being investigated for use on initial lunar surface power systems. The use of water may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a representative lunar surface reactor shield design is evaluated at various power levels in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to anchor a CFD model. Performance of a water shield on the lunar surface is then predicted by CFD models anchored to test data. The accompanying viewgraph presentation includes the following topics: 1) Testbed Configuration; 2) Core Heater Placement and Instrumentation; 3) Thermocouple Placement; 4) Core Thermocouple Placement; 5) Outer Tank Thermocouple Placement; 6) Integrated Testbed; 7) Methodology; 8) Experimental Results: Core Temperatures; 9) Experimental Results; Outer Tank Temperatures; 10) CFD Modeling; 11) CFD Model: Anchored to Experimental Results (1-g); 12) CFD MOdel: Prediction for 1/6-g; and 13) CFD Model: Comparison of 1-g to 1/6-g.
The study examined the effect of natural convection in applying the modified laser flash method to measure thermal properties of semiconductor melts. Common laser flash method uses a laser pulse to heat one side of a thin circular sample and measures the temperature response of the other side. Thermal diffusivity can be calculations based on a heat conduction analysis. For semiconductor melt, the sample is contained in a specially designed quartz cell with optical windows on both sides. When laser heats the vertical melt surface, the resulting natural convection can introduce errors in calculation based on heat conduction model alone. The effect of natural convection was studied by CFD simulations with experimental verification by temperature measurement. The CFD results indicated that natural convection would decrease the time needed for the rear side to reach its peak temperature, and also decrease the peak temperature slightly in our experimental configuration. Using the experimental data, the calculation using only heat conduction model resulted in a thermal diffusivity value is about 7.7% lower than that from the model with natural convection. Specific heat capacity was about the same, and the difference is within 1.6%, regardless of heat transfer models.
A space-based experiment is currently under development to study diffusion-controlled, gas-phase, low temperature oxidation reactions, cool flames and auto-ignition in an unstirred, static reactor. At Earth's gravity (1g), natural convection due to self-heating during the course of slow reaction dominates diffusive transport and produces spatio-temporal variations in the thermal and thus species concentration profiles via the Arrhenius temperature dependence of the reaction rates. Natural convection is important in all terrestrial cool flame and auto-ignition studies, except for select low pressure, highly dilute (small temperature excess) studies in small vessels (i.e., small Rayleigh number). On Earth, natural convection occurs when the Rayleigh number (Ra) exceeds a critical value of approximately 600. Typical values of the Ra, associated with cool flames and auto-ignitions, range from 104-105 (or larger), a regime where both natural convection and conduction heat transport are important. When natural convection occurs, it alters the temperature, hydrodynamic, and species concentration fields, thus generating a multi-dimensional field that is extremely difficult, if not impossible, to be modeled analytically. This point has been emphasized recently by Kagan and co-workers who have shown that explosion limits can shift depending on the characteristic length scale associated with the natural convection. Moreover, natural convection in unstirred reactors is never "sufficiently strong to generate a spatially uniform temperature distribution throughout the reacting gas." Thus, an unstirred, nonisothermal reaction on Earth does not reduce to that generated in a mechanically, well-stirred system. Interestingly, however, thermal ignition theories and thermokinetic models neglect natural convection and assume a heat transfer correlation of the form: q=h(S/V)(T(bar) - Tw) where q is the heat loss per unit volume, h is the heat transfer coefficient, S/V is the surface to volume ratio, and (T(bar) - Tw ) is the spatially averaged temperature excess. This Newtonian form has been validated in spatially-uniform, well-stirred reactors, provided the effective heat transfer coefficient associated with the unsteady process is properly evaluated. Unfortunately, it is not a valid assumption for spatially-nonuniform temperature distributions induced by natural convection in unstirred reactors. "This is why the analysis of such a system is so difficult." Historically, the complexities associated with natural convection were perhaps recognized as early as 1938 when thermal ignition theory was first developed. In the 1955 text "Diffusion and Heat Exchange in Chemical Kinetics", Frank-Kamenetskii recognized that "the purely conductive theory can be applied at sufficiently low pressure and small dimensions of the vessel when the influence of natural convection can be disregarded." This was reiterated by Tyler in 1966 and further emphasized by Barnard and Harwood in 1974. Specifically, they state: "It is generally assumed that heat losses are purely conductive. While this may be valid for certain low pressure slow combustion regimes, it is unlikely to be true for the cool flame and ignition regimes." While this statement is true for terrestrial experiments, the purely conductive heat transport assumption is valid at microgravity (mu-g). Specifically, buoyant complexities are suppressed at mu-g and the reaction-diffusion structure associated with low temperature oxidation reactions, cool flames and auto-ignitions can be studied. Without natural convection, the system is simpler, does not require determination of the effective heat transfer coefficient, and is a testbed for analytic and numerical models that assume pure diffusive transport. In addition, mu-g experiments will provide baseline data that will improve our understanding of the effects of natural convection on Earth.
The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.
A water based shielding system is being investigated for use on initial lunar surface power systems. The use of water may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. A simple 1-D thermal model indicates the necessity of natural convection to maintain acceptable temperatures and pressures in the water shield. CFD analysis is done to quantify the natural convection in the shield, and predicts sufficient natural convection to transfer heat through the shield with small temperature gradients. A test program will he designed to experimentally verify the thermal hydraulic performance of the shield, and to anchor the CFD models to experimental results.
The impact of buoyancy on the mean velocity, temperature, and scalar concentration profiles in the lower atmosphere is typically investigated within the framework of Monin-Obukhov similarity theory (MOST). MOST is the theoretical foundation for parametrizing surface-atmosphere exchanges in nearly all weather, climate, and hydrological models.According to MOST, the classic logarithmic profiles of mean velocity and temperature break down as the buoyancy effects become important. However, recent studies on turbulent Rayleigh-Bénard convection and natural convection along vertical walls suggest that the mean temperature in the near-surface region still follows a logarithmic profile.Motivated by these new results, we study the mean potential temperature profile in sheared and unstably stratified atmospheric boundary layers using direct numerical simulations and field observations. We find that the mean potential temperature profile remains logarithmic across a wide range of stability parameters, which characterizes the relative importance of buoyancy versus shear effects. Compared to MOST, our results suggest that the buoyancy force does not modify the logarithmic nature of the mean potential temperature profile, but instead modulates its slope, which is no longer universal and differs from 1/κ,whereκisthe von Kármán constant. Furthermore, this study provides another perspective on scalar turbulence in the atmospheric boundary layer
This report presents the modeling progress of a university consortium studying flexible modeling for turbulent heat transfer. In the context of advanced nuclear reactor design, where challenges include non-unity Prandtl fluids, free and mixed convection, and transitional flow, computational fluid dynamics methods are underutilized due to low confidence in modeling approaches and high computational cost. This report evaluates the performance of engineering CFD models in diabatic, buoyant turbulent flow. It finds that all turbulence models including several variants of the k-ε and k-ω models struggle to predict accurate turbulent momentum and heat transfer in such flows. The Nusselt numbers have been compared between the models and the DNS data, where calculations have been performed for each case and trends have shown a good agreement between DNS estimated Nusselt numbers and available correlations as well as experimental data. A novel DNS correlation for high Pr cases as they are transitioning from mixed convection to natural convection has been proposed. While Nusselt number errors relative to DNS range from 20% to 50%, the models capture similar trends to DNS with respect to Nusselt suppression and amplification under varying levels of buoyancy effect. This report also highlights model form error as a significant contributor to CFD predictions and proposes a framework for quantifying model error and improving confidence in CFD calculations. To improve the predictive capability of engineering CFD models, data-driven approaches for turbulence models are investigated. Theoretical frameworks based on the invariant tensor / vector basis neural networks for prediction of Reynolds stresses and turbulent heat fluxes are employed. The models are developed using direct numerical simulations data for forced convection flows of different fluids in vertical planar channel domain. The framework is implemented in spectral element solvers Nek5000 / nekRS and has shown a potential for future development and consideration of mixed convection flows.
A thermal design of a solar receiver has been developed for the solutions of problems involving phase-change thermal energy storage and natural convection loss. Two dimensional axisymmetrical solidification and melting of materials contained between two concentric cylinders of finite length has been studied for thermal energy storage analysis. For calculation of free convection loss inside receiver cavity, two dimensional axisymmetrical, laminar, transient free convection including radiation effects has been studied using integral/finite difference method. Finite difference equations are derived for the above analysis subject to constant or variable material properties, initial conditions, and boundary conditions. The validity of the analyses has been substantiated by comparing results of the present general method with available analytic solutions or numerical results reported in the literature. Both explicit and implicit schemes are tested in phase change analysis with different number of nodes ranging from 4 to 18. The above numerical methods have been applied to the existing solar receiver analyzing computer code as additional subroutines. The results were computed for one of the proposed Brayton cycle solar receiver models running under the actual environmental conditions. Effect of thermal energy storage on the thermal behavior of the receiver has been estimated. Due to the thermal energy storage, about 65% reduction on working gas outlet temperature fluctuation has been obtained; however, maximum temperature of thermal energy storage containment has been increased about 18%. Also, effect of natural convection inside a receiver cavity on the receiver heat transfer has been analyzed. The finding indicated that thermal stratification occurs during the sun time resulting in higher receiver temperatures at the outlet section of the gas tube, and lower temperatures at the inlet section of the gas tube when compared with the results with no natural convection. Due to heat supply from the air during the shade time, minimum temperature has been increased, while maximum temperature has been reduced due to convection loss to air. Consequently, cyclic temperature fluctuation has been reduced 29% for working gas and 16% for thermal energy storage containment. On the other hand, despite the presence of the natural convection the time-averaged temperatures for receiver components were found to be similar for two cases with/without natural convection (maximum difference was 1.8%).
Molten salt flow characterization presents numerous challenges due to the hostile environments that cause corrosion and erosion of instrumentation and structural components. To support future molten salt flow characterization under natural convection conditions, a LiCl–KCl eutectic molten salt loop was designed and constructed. The primary objective of this loop is to facilitate natural convection as the principal cooling mechanism, enabling insights into the physics behind natural convection in closed loops and serving as a baseline for loop dimensional and non-dimensional analyses. Here, this study summarizes the fundamental functions employed for flow characterization and introduces a model to estimate flow rate when intrusive instrumentation is unavailable. The approach relies solely on structural surface measurements to avoid flow disturbances. Furthermore, a comprehensive thermal–hydraulic analysis is included to deepen understanding of the system’s behavior.
An analysis is presented that explains the variation of superheat with subcooling that has been observed by a number of researchers investigating nucleate boiling heat transfer at constant heat flux. It is shown that superheat initially increases with increasing subcooling near saturated conditions because of the way in which changes in active site density and average bubble frequency with increasing subcooling affect the rate of heat removal from the heater surface by enthalpy transport and microlayer evaporation. As subcooling increases further, natural convection begins to play an increasingly important role in the heat transfer process. Ultimately, natural convection is able to accommodate the entire imposed heat flux, after which superheat decreases as subcooling increases. The success of the analysis in explaining the variation of superheat with subcooling suggests that the rate of the heat removal from the heater surface is completely determined by the mechanisms of enthalpy transport, natural convection, and microlayer evaporation.
The combined radiation/conduction heat transfer in high-porosity, high-temperature fibrous insulations was investigated experimentally and numerically. The effective thermal conductivity of fibrous insulation samples was measured over the temperature range of 300-1300 K and environmental pressure range of 1.33 x 10(exp -5)-101.32 kPa. The fibrous insulation samples tested had nominal densities of 24, 48, and 72 kilograms per cubic meter and thicknesses of 13.3, 26.6 and 39.9 millimeters. Seven samples were tested such that the applied heat flux vector was aligned with local gravity vector to eliminate natural convection as a mode of heat transfer. Two samples were tested with reverse orientation to investigate natural convection effects. It was determined that for the fibrous insulation densities and thicknesses investigated no heat transfer takes place through natural convection. A finite volume numerical model was developed to solve the governing combined radiation and conduction heat transfer equations. Various methods of modeling the gas/solid conduction interaction in fibrous insulations were investigated. The radiation heat transfer was modeled using the modified two-flux approximation assuming anisotropic scattering and gray medium. A genetic-algorithm based parameter estimation technique was utilized with this model to determine the relevant radiative properties of the fibrous insulation over the temperature range of 300-1300 K. The parameter estimation was performed by least square minimization of the difference between measured and predicted values of effective thermal conductivity at a density of 24 kilograms per cubic meters and at nominal pressures of 1.33 x 10(exp -4) and 99.98 kPa. The numerical model was validated by comparison with steady-state effective thermal conductivity measurements at other densities and pressures. The numerical model was also validated by comparison with a transient thermal test simulating reentry aerodynamic heating conditions.