Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MoIr”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Deformations and strains in a thick adherend lap joint

Displacement fields in a thick adherend lap joint were measured by high-sensitivity moire interferometry. Contour maps of in-plane U and V displacements were obtained across adhesive and adherend surfaces. Loads ranged from a modest load to a near-failure load. Quantitative results are given for displacements and strains in the adhesive and along the adhesive/adherend boundary lines. The results show nearly constant shear strain in the adhesive, nonlinear strains as a function of load or average shear stress, and viscoelastic or time-dependent response. Longitudinal normal strains in the adhesive are nearly two orders of magnitude less than the shear strains. With its subwavelength displacement resolution and high spatial resolution, moire interferometry is especially well suited for deformation studies of adhesive joints.

Post, D.↗

A semi-micromechanic interlaminar strain analysis on curved-beam specimens

Experimental analyses were performed for determination of interlaminar strains in circumferentially unidirectional curved beam specimens. Semi-circular and semi-elliptic carbon-epoxy specimens were subjected to opening mode tensile loadings. Whole field measurements were recorded at load levels from about 5 to more than 90 pct of failure loads. Contour maps of displacement fields were obtained by using moire interferometry, using reference gratings of 2400 lines/mm or 60,690 lines/in. Whole field contour maps of circumferential and interlaminar strains were obtained by using moire interferometry in a semi-micromechanic scale. Various anomalous effects were observed in the displacement fields. The zig-zag fringe patterns indicated that the fiber orientation in each layer was not truly circumferential. This deviation from the unidirectionality caused free-edge effects, such as interlaminar shear strains even at the axis of symmetry and the altered normal strains in the thickness direction. In the resin rich zones between layers, the tensile interlaminar strain was excessively large due to the large compliance. As the result of the combined effect of these anomalous behaviors, the values of the interlaminar tensile strains were larger than those predicted analytically. The modulus E sub 3 was actually smaller than the assumed value E sub 2 by 20 pct.

Joh, Duksung↗

Composite material shear property measurement using the Iosipescu specimen

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. Finite element analysis and moire interferometry are used to assess the uniformity of the shear stress field in the test section of unidirectional and cross-ply graphite-epoxy composites. The nonuniformity of the strain field and the sensitivity of some fiber orientations to the specimen/fixture contact mechanics are discussed. The shear responses obtained for unidirectional and cross-ply graphite-epoxy composites are discussed and problems associated with anomalous behavior are addressed. An experimental determination of the shear response of a range of material systems using strain gage instrumentation and moire interferometry is performed.

Ho, Henjen↗

A comparison of three shear test methods for composite materials

A graphite-epoxy composite material system is used to evaluate the performance of three popular shear tests - the 10-deg off-axis, the +/-45-deg tension, and the Iosipescu specimen tested in the modified Wyoming fixture. A comparison of the shear stress-strain response for each test method is made using a conventional strain gage instrument and moire interferometry. The uniformity and purity of the strain fields in the test sections of the specimens are discussed, and the shear responses obtained from each test are presented and compared. It is shown that the shear stress-strain responses obtained by instrumenting only one face of the 90-deg Iosipescu specimen could give erroneous results. The +/-45-deg tensile and 0-deg Iosipescu specimens were not affected by front-to-back face shear strain variations. Correction factors could be applied to bring all responses together, within the limits of the material uniformity, which was itself documented in the moire fringe patterns.

Ho, H.↗

Telescope for x ray and gamma ray studies in astrophysics

Imaging of x-rays has been achieved by various methods in astrophysics, nuclear physics, medicine, and material science. A new method for imaging x-ray and gamma-ray sources avoids the limitations of previously used imaging devices. Images are formed in optical wavelengths by using mirrors or lenses to reflect and refract the incoming photons. High energy x-ray and gamma-ray photons cannot be reflected except at grazing angles and pass through lenses without being refracted. Therefore, different methods must be used to image x-ray and gamma-ray sources. Techniques using total absorption, or shadow casting, can provide images in x-rays and gamma-rays. This new method uses a coder made of a pair of Fresnel zone plates and a detector consisting of a matrix of CsI scintillators and photodiodes. The Fresnel zone plates produce Moire patterns when illuminated by an off-axis source. These Moire patterns are deconvolved using a stepped sine wave fitting or an inverse Fourier transform. This type of coder provides the capability of an instantaneous image with sub-arcminute resolution while using a detector with only a coarse position-sensitivity. A matrix of the CsI/photodiode detector elements provides the necessary coarse position-sensitivity. The CsI/photodiode detector also allows good energy resolution. This imaging system provides advantages over previously used imaging devices in both performance and efficiency.

Weaver, W. D.↗

An Evaluation of the Iosipescu Specimen for Composite Materials Shear Property Measurement

A detailed evaluation of the suitability of the Iosipescu specimen tested in the modified Wyoming fixture is presented. An experimental investigation using conventional strain gage instrumentation and moire interferometry is performed. A finite element analysis of the Iosipescu shear test for unidirectional and cross-ply composites is used to assess the uniformity of the shear stress field in the vicinity of the notch, and demonstrate the effect of the nonuniform stress field upon the strain gage measurements used for the determination of composite shear moduli. From the test results for graphite-epoxy laminates, it is shown that the proximity of the load introduction point to the test section greatly influences the individual gage readings for certain fiber orientations but the effect upon shear modulus measurement is relatively unimportant. A numerical study of the load contact effect shows the sensitivity of some fiber configurations to the specimen/fixture contact mechanism and may account for the variations in the measured shear moduli. A comparison of the strain gage readings from one surface of a specimen with corresponding data from moire interferometry on the opposite face documented an extreme sensitivity of some fiber orientations to eccentric loading which induced twisting and yielded spurious shear stress-strain curves. In the numerical analysis, it is shown that the Iosipescu specimens for different fiber orientations have to be modeled differently in order to closely approximate the true loading conditions. Correction factors are needed to allow for the nonuniformity of the strain field and the use of the average shear stress in the shear modulus evaluation. The correction factors, which are determined for the region occupied by the strain gage rosette, are found to be dependent upon the material orthotropic ratio and the finite element models. Based upon the experimental and numerical results, recommendations for improving the reliability and accuracy of the shear modulus values are made, and the implications for shear strength measurement discussed. Further application of the Iosipescu shear test to woven fabric composites is presented. The limitations of the traditional strain gage instrumentation on the satin weave and high tow plain weave fabrics is discussed. Test results of a epoxy based aluminum particulate composite is also presented. A modification of the Iosipescu specimen is proposed and investigated experimentally and numerically. It is shown that the proposed new specimen design provides a more uniform shear stress field in the test section and greatly reduces the normal and shear stress concentrations in the vicinity of the notches. While the fabrication and the material cost of the proposed specimen is tremendously reduced, it is shown the accuracy of the shear modulus measurement is not sacrificed.

Ho, Henjen↗

Evaluation of a ''CMOS'' Imager for Shadow Mask Hard X-ray Telescope

We have developed a hard x-ray coder that provides high angular resolution imaging capability using a coarse position sensitive image plane detector. The coder consists of two Fresnel zone plates. (FZP) Two such 'FZP's generate Moire fringe patterns whose frequency and orientation define the arrival direction of a beam with respect to telescope axis. The image plane detector needs to resolve the Moire fringe pattern. Pixilated detectors can be used as an image plane detector. The recently available 'CMOS' imager could provide a very low power large area image plane detector for hard x-rays. We have looked into a unit made by Rad-Icon Imaging Corp. The Shadow-Box 1024 x-ray camera is a high resolution 1024xl024 pixel detector of 50x50 mm area. It is a very low power, stand alone camera. We present some preliminary results of our investigation of evaluation of such camera.

Desai, Upendra D.↗

Measuring the conductor spacing in flat conductor cables

Interference method produces a moire pattern having a shape correlated with the lead spacing. A continuous check of the spacing is possible if the material between the leads is translucent. Technique is quick, accurate, convenient, and simple to operate.

Angele, W.↗

A semi-automatic measuring machine

A machine designed to locate automatically a star image on a photographic plate from approximate coordinates on a punched card and to measure and record its position to a micron is described. The main frame of the machine is of granite, as are the x and y coordinate carriages which move on air bearings against granite ways. The system is capable of making measurements continuously over a 10 x 10 inch range by means of a Ferranti moire fringe system, with a least count of one micron.

Strand, K. A.↗

The extraction of accurate coordinates of images on photographic plates by means of a scanning type measuring machine

The Moire method experimental stress analysis is similar to a problem encountered in astrometry. It is necessary to extract accurate coordinates from images on photographic plates. The solution to the mutual problem found applicable to the field of experimental stress analysis is presented to outline the measurement problem. A discussion of the photo-reading device developed to make the measurements follows.

Ross, B. E.↗

Scanning mirror for infrared sensors

A high resolution, long life angle-encoded scanning mirror, built for application in an infrared attitude sensor, is described. The mirror uses a Moire' fringe type optical encoder and unique torsion bar suspension together with a magnetic drive to meet stringent operational and environmental requirements at a minimum weight and with minimum power consumption. Details of the specifications, design, and construction are presented with an analysis of the mirror suspension that allows accurate prediction of performance. The emphasis is on mechanical design considerations, and brief discussions are included on the encoder and magnetic drive to provide a complete view of the mirror system and its capabilities.

Anderson, R. H.↗

Circular carrier-frequency photography for observing phase objects

A circular grating is photographed through a phase object which deforms the image of the grating lines. By superimposing these deformed lines with a master grating on photographic film, moire patterns are observed. These patterns are interpreted as fringes of constant radial derivative.

Silva, D. E.↗

Circular carrier-frequency photography for observing phase objects.

A circular grating is photographed through a phase object which deforms the image of the grating lines. By super-imposing these deformed lines with a master grating on photographic film, moire patterns are observed. These patterns are interpreted as fringes of constant radial derivative.

Silva, D. E.↗

Optical Signal Processing: Poisson Image Restoration and Shearing Interferometry

Optical signal processing can be performed in either digital or analog systems. Digital computers and coherent optical systems are discussed as they are used in optical signal processing. Topics include: image restoration; phase-object visualization; image contrast reversal; optical computation; image multiplexing; and fabrication of spatial filters. Digital optical data processing deals with restoration of images degraded by signal-dependent noise. When the input data of an image restoration system are the numbers of photoelectrons received from various areas of a photosensitive surface, the data are Poisson distributed with mean values proportional to the illuminance of the incoherently radiating object and background light. Optical signal processing using coherent optical systems is also discussed. Following a brief review of the pertinent details of Ronchi's diffraction grating interferometer, moire effect, carrier-frequency photography, and achromatic holography, two new shearing interferometers based on them are presented. Both interferometers can produce variable shear.

Hong, Yie-Ming↗