Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Mars Ascent Vehicle Hybrid PropulsionEffort

A technology development program was undertaken to determine if the benefits of hybrid rocket propulsion could be realized for a Mars Ascent Vehicle (MAV) application. Specifically, the goal of this program was to increase the Technology Readiness Level (TRL) of a hybrid propulsion system such that it could be considered for a potential Mars Sample Return Campaign. Over the course of approximately five years, a new, wax-based fuel was developed, characterized and tested with Mixed Oxides of Nitrogen (from MON-3 to MON-25). Various ignition mechanisms were tested and solid hypergolic additives were evaluated for their potential to ignite the hybrid motor. Several hot-fire test campaigns were completed at both sub- and full-scale. The technology development program was born out of a JPL study documented by Shotwell and Karp that identified the Single Stage to Orbit (SSTO) hybrid propulsion system for a potential Mars Ascent Vehicle to be the lowest Gross Lift Off Mass option from the ten configurations evaluated. Benefits of the hybrid option included its predicted favorable low temperature storage and operation behavior, high performance and ability to restart (enabling the SSTO). The main disadvantage of the hybrid option was its low TRL,as it essentially started as a blank sheet design with a new fuel development. Near the end of the technology development program, a Preliminary Architecture Assessment (PAA) was completed to evaluate a single-stage hybrid propulsion system and a two-stage solid propulsion system for a potential MAV. The solid propulsion system was selected for further study in 2019, primarily because of its flight heritage. While the hybrid technology development program made many strides, there was still a list of challenges to overcome. This paper will discuss the substantial progress and remaining challenges from the technology development effort from 2015 through 2019. This includes fuel development and reformulation, sub- and full-scale testing at Space Propulsion Group, full scale testing at Parabilis, full scale testing at Whittinghill Aerospace, hypergolic additive testing at Purdue and Penn State and the evaluation of adding hypergolic additives to a full-scale grain. It also includes a discussion of the design that resulted from the Preliminary Architecture Assessment.

hybrid rocket↗

Little prairie under the panel: testing native pollinator habitat seed mix establishment at three utility-scale solar sites in Minnesota

Abstract As more land is being utilized for large-scale solar energy projects, there are increasing discussions from stakeholders on how to utilize land under solar panels to promote biodiversity. One path is to plant habitat beneficial to pollinators and other insects, but there have been few long-term studies that examine how different vegetation and seed mixes establish underneath solar panels. This study addresses a scientific gap to determine whether native pollinator seed mixes successfully establish over time under solar arrays using a systematic assessment of eight seed mixes planted at three utility-scale solar sites in Minnesota. We assess establishment with a percent native coverage metric, which is an assessment of native species observations compared to total observations during percent cover analyses in our vegetative test plots. The percent native coverage metric allows for a measurement of how the seed mix established and how the seed mix persists over time. The percent native coverage under and in between the solar photovoltaic (PV) arrays rose from 10% after one year of planting to 58% after three years across all sites, while the native coverage of the full sun control area rose from 9.6% to 70% under the same period, showing that native prairie and pollinator plants successfully established under the array, although to a lesser extent than in full sun conditions. Percent native coverage under the PV arrays rose 5- to 8-fold for each of the three sites from over the course of the study, while the coverage of weeds decreased for all three sites over the same period. Percent native coverage varied by seed mix over the project years, but every seed mix experienced a higher percent native coverage year after year under the PV arrays. Our results did not indicate a difference in establishment across placement within the array; the center, west, and east portions of the areas in between panels had similar establishment rates at two out of three sites, indicating that the same seed mix can be applied throughout the array. Out of 101 plant species seeded, we observed the establishment of 68 species in our vegetative test plots, and we detailed the top 20 observed species to inform future seed mix development. Based on these findings, native pollinator vegetation can establish over time at solar arrays, and it can be suitable for creating habitat at utility-scale solar sites.

14 SOLAR ENERGY↗

Characterizing Face Sheet/Core Disbonding Using the Single Cantilever Beam Test: Results from an International Round Robin

Test results from an international round robin are presented. The single cantilever beam (SCB) test was used to characterize face sheet/core disbonding in sandwich components in an effort to help standardization. Each of the seven participating laboratories performed a set of five baseline tests using the same protocol, however, using their own specific equipment. In addition, each laboratory performed two sets of tests with altered tests conditions which included using a test fixture with a translating carriage and performing the tests with different loading and unloading speeds. The orientation of the disbond front with respect to the honeycomb core cells was varied and the effect on the fracture toughness was also studied. Additional factors that could influence test results were investigated, such as the use of a saw cut starter disbond as an alternative to Teflon® release film, and the effects of using a face sheet doubler to increase the bending stiffness. For each set of tests, summary results such as load/displacements plots, observed disbond growth location and calculated energy release rates are reported and a comparison of results between labs is presented. Critical strain energy release rate measurements from SCB tests are also compared with measurements made from an alternative test, namely the double cantilever beam with uneven bending moments (DCB-UBM) test, which has been studied extensively at the Technical University of Denmark and proposed as a mixed-mode test standard. A set of recommendations are made with respect to improving the SCB test and a path to standardization is presented.

Ronald Krueger↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Insights into determining pore size properties of ultrafiltration membranes

The selectivity of porous membranes is often characterized using solute rejection tests, where membranes are challenged with dilute aqueous solutions of neutral solutes at operating conditions that minimize concentration polarization and fouling. In single solute tests, a membrane is challenged with one molecular weight (MW) solute at a time from low to high MW. Since single solute methods are time-intensive, mixed solute tests have become more common, where a mixture of several MW solutes challenges a membrane at once. However, the presence of large solutes in a mixture increases the rejection of smaller solutes. Furthermore, there are no universally accepted operating conditions or standard methods used by membrane manufacturers or researchers for the experiments, leading to difficulty in pore size and pore characteristic comparisons. In this paper, commercial ultrafiltration membranes were challenged with single and mixed solute polyethylene glycol (PEG) and dextran aqueous solutions. First, rejection values determined using total organic carbon (TOC) and high-performance liquid chromatography (HPLC) from single solute filtration experiments are compared. Differences in rejection curves obtained by the two techniques are attributed to solute polydispersity. Mixed solute filtration experiments with binary mixtures of solutes showcased co-solute interactions, which increase with both the size and weight percent of large solute in the mixture. Mixed solute filtration experiments at varying operating conditions (i.e., stir speed and flux) were conducted to determine operating conditions that mitigate co-solute interactions. Stir speed had a minimal effect on co-solute interactions. In contrast, low flux conditions can help minimize co-solute interactions, leading to pore size distributions that closely resemble results observed in single solute filtration using narrowly dispersed solutes. Additionally, at low flux conditions, the predicted membrane pore size distributions utilizing mixed solute experiments with PEG and dextran were similar.

36 MATERIALS SCIENCE↗

Bridging the Gap Between Pure and Mixed-Gas Performance of Thin-Film Composite Membranes

This study examines the influence of cell design on mixed-gas testing with PolyActive™ TFC membranes, featuring pure-gas CO₂ permeance of 1700–3100 GPU, representative of state-of-the-art CO₂/N₂ separation membranes. By designing and 3D-printing a counter-current permeation cell with optimized flow efficiency, we achieved a 33–41% increase in mixed-gas CO₂ permeance compared to traditional cells. Additionally, a comparison of sweep-gas and vacuum permeation methods revealed that vacuum operation mitigates downstream polarization, enhancing mixed-gas CO₂ permeance by 41%. These results underscore the critical role of permeation cell design and testing methods in accurately evaluating membrane performance, with significant implications for scaling up TFC membranes and optimizing industrial processes.

3D printing↗

Lunar and Planetary Science XXXVI, Part 12

Topics discussed include: The Ancient Lakes in Hellas Basin Region as Seen Through the First Year of Mars Express HRSC-Camera; DISR Observations of Craters at Titan at the Huygens Landing Site: Insights Anticipated; The Sun s Dust Disk - Discovery Potential of the New Horizons Mission During Interplanetary Cruise; Evidence for Aqueously Precipitated Sulfates in Northeast Meridiani Using THEMIS and TES Data; Integrated Spectroscopic Studies of Anhydrous Sulfate Minerals; Venusian Channel Formation as a Subsurface Process; Reexamination of Quartz Grains from the Permian-Triassic Boundary Section at Graphite Peak, Antarctica; Observations of Calcium Sulfate Deposits at High Latitudes by OMEGA/Mex at Km/Pixel Resolutions; Observations of the North Permanent Cap of Mars in Mid-Summer by OMEGA/MEX at km per Pixel Resolutions; Classification and Distribution of Patterned Ground in the Southern Hemisphere of Mars Genesis: Removing Contamination from Sample Collectors; Thermal Characterization of Fe3O4 Nanoparticles Formed from Poorly Crystalline Siderite; Hydrogen Abundances in Metal Grains from the Hammadah Al Hamra (HaH) 237 Metal-rich Chondrite: A Test of the Nebular-Formation Theory; REE and Some Other Trace Elements Distributions of Mineral Separates in Atlanta (EL6); The Composition and Origin of the Dewar Geochemical Anomaly; Asteroid Modal Mineralogy Using Hapke Mixing Models: Testing the Utility of Spectral Lookup Tables; and The Huygens Mission at Titan: Results Highlights. (sup 182)Hf-(sup 182)W Chronometry and an Early Differentiation in the Parent Body of Ureilites Ground Penetrating Radar in Sedimentary Rocks Mars, Always Cold, Sometimes Wet: New Constraints on Mars Denudation Rates and Climate Evolution from Analog Studies at Haughton Crater, Devon Island, High Arctic Europa s Porous Ice Rheology and Implications for Ice-penetrating Radar Scattering Loss Surface Generated Cracks on Europa

Source record↗

Effect of swirler-mounted mixing venturi on emissions of flame-tube combustor using jet A fuel

Six headplate modules in a flame-tube combustor were evaluated. Unburned hydrocarbons, carbon monoxide, and oxides of nitrogen were measured for three types of fuel injectors both with and without a mixing venturi. Tests were conducted using jet A fuel at an inlet pressure of 0.69 megapascal, an inlet temperature of 478 K, and an isothermal static pressure drop of 3 percent. Oxides of nitrogen were reduced by over 50 percent with a mixing venturi with no performance penalties in either other gaseous emissions or pressure drop.

Ercegovic, D. B.↗

Performance of a quantitative study of instability-related delamination growth

An experimental program was conducted to quantify instability-induced imbedded delamination growth. Static tests on double cantilever beam (DCB) specimens yielded the critical mode 1 strain energy release rate (G sub 1 C) for T300/5208 graphite/epoxy. Static tests on mixed mode cracked lap shear (CLS) specimens, and a nonlinear finite element analysis (NFEA) of the CLS specimen to separate mode 1 and mode 2 effects, yielded the critical mode 2 strain energy release rate (G sub 2 C) for T300/5208. Constant amplitude fatigue tests on DCB and CLS specimens, along with the NFEA results on CLS specimens, quantified mode 1 and mode 2 contributions to delamination growth rate. Fatigue tests were conducted at a frequency (omega) of 10 Hertz, maintaining the minimum to maximum cyclic load ratio (R) at 0.05. Static compression and constant amplitude compression fatigue tests were also conducted on specimens with imbedded through the width (ITTW) delaminations. Kapton imbeddments were located below 3, 4 or 6 plies in a 64-ply laminate, during layup, to simulate ITTW delaminations.

Ramkumar, R. L.↗

Orthostatic Hypotension After Long-Duration Space Flight: NASA's Experiences from the International Space Station

Our laboratory previously reported that the incidence of orthostatic hypotension (OH) was greater after long- than short-duration spaceflight in astronauts who participated in Mir Space Station and Space Shuttle missions. To confirm and extend these findings, we retrospectively examined tilt test data from International Space Station (ISS) and Shuttle astronauts. We anticipated that the proportion of ISS astronauts experiencing OH would be high on landing day and the number of days to recover greater after long- than short-duration missions. Methods: Twenty ISS and 66 Shuttle astronauts participated in 10-min 80? head-up tilt tests 10 d before launch (L-10), on landing day (R+0) or 1 d after landing (R+1). Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. Many astronauts repeated the test 3 d (R+3) after landing. Fisher?s Exact Test was used to compare the ability of ISS and Shuttle astronauts to complete the tilt test on R+0. Cox regression was used to identify cardiovascular parameters that were associated with test completion across all tests, and mixed model analysis was used to compare the change and recovery rates between ISS and Shuttle astronauts. In these analyses, ISS data from R+0 and R+1 were pooled to provide sufficient statistical power. Results: The proportion of astronauts who completed the tilt test on R+0 without OH was less in ISS than in Shuttle astronauts (p=0.03). On R+0, only 2 of 6 ISS astronauts completed the test compared to 53 of 66 (80%) Shuttle astronauts. However, 8 of 9 ISS astronauts completed the test on R+1. On R+3, 13 of 15 (87%) of the ISS and 19 of 19 (100%) of the Shuttle astronauts completed the 10-min test. An index comprised of stroke volume and diastolic blood pressure provided a very good prediction of overall tilt survival. This index was altered by spaceflight similarly for both groups soon after landing (pooled R+0 and R+ 1), but ISS astronauts did not recover at the same rate as Shuttle astronauts (p=0.007). Conclusions: The proportion of ISS astronauts who could not complete the tilt test on R+0 due to OH (4 of 6) is similar to that reported in astronauts who flew on Mir (5 of 6). Further, cardiovascular parameters most closely associated with OH recover more slowly after long- compared to short-duration spaceflight.

Lee, Stuart M. C.↗

Effect of ratio of wall boundary layer thickness to jet diameter on mixing of a normal hydrogen jet in a supersonic stream

A preliminary experimental program was conducted to determine the effect of the ratio of the free-stream boundary-layer thickness to jet diameter on the secondary jet penetration and mixing rate. Tests were conducted on a flat plate in a Mach number 4.05 airflow with sonic injection of hydrogen normal to the free-stream direction from circular underexpanded injectors. The ratio of boundary-layer thickness to jet diameter ranged from 1.25 to 6.5. Previous correlations of mixing performance were modified to account for the effect of the ratio of boundary-layer thickness to jet diameter.

Mcclinton, C. R.↗

Evaluation of FTWC Vent System

A monitored exhaust system has been designed for use in venting the Flanged Tritium Waste Containers (FTWCs) at LANL. This system will provide controlled exhaust and emissions monitoring for the FTWCs, and also provide general area exhaust around the venting operations to measure any emissions which may bypass the primary vent system. A full description of the process and need for the system is described in the Pre-Construction Application for this project. This document describes the commissioning testing performed on the FTWC vent system to prepare it for use. The system has been tested and shown to meet ANSI standard requirements and is fully suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fully‐Printed Ion Sensor Arrays for Measuring Agricultural Nitrogen and Potassium Concentrations Using Nernstian and AI Models

Abstract The chemical composition of growing media is a key factor for plant growth, impacting agricultural yield and sustainability. However, there is a lack of affordable chemical sensors for ubiquitous nutrient ion monitoring in agricultural applications. This work investigates using fully printed ion‐sensor arrays to measure the concentrations of nitrate, ammonium, and potassium in mixed‐electrolyte media. Ion sensor arrays composed of nitrate, ammonium, and potassium ion‐selective electrodes and a printed silver‐silver chloride (Ag/AgCl) reference electrode are fabricated and characterized in aqueous solutions in a range of concentrations that encompass what is typical for agricultural growing media (0.01 m m –1 m ). The sensors are also tested in mixed‐electrolyte solutions of NaNO 3 , NH 4 Cl, and KCl of varying concentrations, and the recorded potentials are input into Nernstian and artificial neural network models to compare the prediction accuracy of the models against ground truth. The artificial neural network models demonstrated higher accuracy over the Nernstian model, and the model using only ion‐sensor inputs is 7.5% more accurate than the Nernstian model under the same conditions. By enabling more precise and efficient fertilizer application, these sensor arrays coupled to computational models can help increase crop yields, optimize resource use, and reduce environmental impact.

Goodrich, Payton [University of California Berkele↗

Three-dimensional analysis of potential vorticity associated with tropopause folds and observed variations of ozone and carbon monoxide

The usability and reliability of potential vorticity as a meteorological stratospheric tracer are evaluated. The concept of potential vorticity conservation during transport in which stratospheric and tropospheric air are mixing is tested. Aircraft data collected on April 20, 1984 in the western and southwestern U.S. are analyzed in order to derive potential vorticity data; vertical cross sections of constant-pressure data and temperature and wind speed gradients are examined. The tropopause fold observed during the April 20, 1984 aircraft flights is described. The potential vorticity, ozone mixing ratio, and carbon monoxide mixing ratio are compared; a positive correlation between potential vorticity and the ozone mixing ratio and a negative correlation between the potential vorticity and the carbon monoxide mixing ratio are detected. The data support the concepts of the conservation of potential vorticity, the entrainment and mixing of tropospheric air across the boundaries of the fold, and the applicability of potential vorticity as a stratospheric tracer.

Danielsen, Edwin F.↗

Integrating CVMix into GOTM (v6.0): a consistent framework for testing, comparing, and applying ocean mixing schemes

Abstract. The General Ocean Turbulence Model (GOTM) is a one-dimensional water column model, including a set of state-of-the-art turbulence closure models, and has widely been used in various applications in the ocean modeling community. Here, we extend GOTM to include a set of newly developed ocean surface vertical mixing parameterizations of Langmuir turbulence via coupling with the Community Vertical Mixing Project (CVMix). A Stokes drift module is also implemented in GOTM to provide the necessary ocean surface waves information to the Langmuir turbulence parameterizations, as well as to facilitate future development and evaluation of new Langmuir turbulence parameterizations. In addition, a streamlined workflow with Python and Jupyter notebooks is also described, enabled by the newly developed and more flexible configuration capability of GOTM. The newly implemented Langmuir turbulence parameterizations are evaluated against theoretical scalings and available observations in four test cases, including an idealized wind-driven entrainment case and three realistic cases at Ocean Station Papa, the northern North Sea, and the central Baltic Sea, and compared with the existing general length scale scheme in GOTM. The results are consistent with previous studies. This development extends the capability of GOTM towards including the effects of ocean surface waves and provides useful toolsets for the ocean modeling community to further study the effects of Langmuir turbulence in a broader scope.

58 GEOSCIENCES↗

Thermogravimetric Analysis (TGA) for Carbon Fiber and Glass Fiber Epoxy Composites and their Constituents

In this work, thermogravimetric analysis (TGA) was performed on samples of a carbon fiber epoxy composite, a glass fiber epoxy composite, and a mixed carbon fiber/glass fiber epoxy composite, as well on each constituent material (polymer epoxy, carbon fibers and glass fibers). TGA was conducted for heating rates from 1-20 C/min with purified purge gases of nitrogen and dry air. For the fiberglass composite, we find that ~70% of the material remains after heating in air to 1200 C. For the carbon fiber epoxy composite, we observe greater mass loss as the carbon fibers can oxidize, leaving little material by the end of the test. The mixed composite, which has a 2:1 ratio of glass fibers to carbon fibers, experienced a total mass loss between the two other composites. By determining the relationship between the thermal decomposition of a composite material and its constituent materials, we can predict the fire behavior of novel composites during the material design phase.

36 MATERIALS SCIENCE↗

The use of real-time, hardware-in-the-loop simulation in the design and development of the new Hughes HS601 spacecraft attitude control system

Realtime simulation and hardware-in-the-loop testing is being used extensively in all phases of the design, development, and testing of the attitude control system (ACS) for the new Hughes HS601 satellite bus. Realtime, hardware-in-the-loop simulation, integrated with traditional analysis and pure simulation activities is shown to provide a highly efficient and productive overall development program. Implementation of high fidelity simulations of the satellite dynamics and control system algorithms, capable of real-time execution (using applied Dynamics International's System 100), provides a tool which is capable of being integrated with the critical flight microprocessor to create a mixed simulation test (MST). The MST creates a highly accurate, detailed simulated on-orbit test environment, capable of open and closed loop ACS testing, in which the ACS design can be validated. The MST is shown to provide a valuable extension of traditional test methods. A description of the MST configuration is presented, including the spacecraft dynamics simulation model, sensor and actuator emulators, and the test support system. Overall system performance parameters are presented. MST applications are discussed; supporting ACS design, developing on-orbit system performance predictions, flight software development and qualification testing (augmenting the traditional software-based testing), mission planning, and a cost-effective subsystem-level acceptance test. The MST is shown to provide an ideal tool in which the ACS designer can fly the spacecraft on the ground.

Slafer, Loren I.↗