Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Minimum Detectable Activities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-E-I-65: The Joint Commission's Requirements for Annual Diagnostic Physics Testing of Nuclear Medicine Equipment, and a Clinically Relevant Methodology for Testing Low-Contrast Resolution

Purpose: To introduce the Joint Commission's requirements for annual diagnostic physics testing of all nuclear medicine equipment, effective 7/1/2014, and to highlight an acceptable methodology for testing lowcontrast resolution of the nuclear medicine imaging system. Methods: The Joint Commission's required diagnostic physics evaluations are to be conducted for all of the image types produced clinically by each scanner. Other accrediting bodies, such as the ACR and the IAC, have similar imaging metrics, but do not emphasize testing low-contrast resolution as it relates clinically. The proposed method for testing low contrast resolution introduces quantitative metrics that are clinically relevant. The acquisition protocol and calculation of contrast levels will utilize a modified version of the protocol defined in AAPM Report #52. Results: Using the Rose criterion for lesion detection with a SNRpixel = 4.335 and a CNRlesion = 4, the minimum contrast levels for 25.4 mm and 31.8 mm cold spheres were calculated to be 0.317 and 0.283, respectively. These contrast levels are the minimum threshold that must be attained to guard against false positive lesion detection. Conclusion: Low contrast resolution, or detectability, can be properly tested in a manner that is clinically relevant by measuring the contrast level of cold spheres within a Jaszczak phantom using pixel values within ROI's placed in the background and cold sphere regions. The measured contrast levels are then compared to a minimum threshold calculated using the Rose criterion and a CNRlesion = 4. The measured contrast levels must either meet or exceed this minimum threshold to prove acceptable lesion detectability. This research and development activity was performed by the authors while employed at West Physics Consulting, LLC. It is presented with the consent of West Physics, which has authorized the dissemination of the information and/or techniques described in the work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEW EVIDENCE FOR CHARGE-SIGN-DEPENDENT MODULATION DURING THE SOLAR MINIMUM OF 2006 TO 2009

The PAMELA space experiment, in orbit since 2006, has measured cosmic rays (CRs) through the most recent period of minimum solar activity with the magnetic field polarity as A < 0. During this entire time, galactic electrons and protons have been detected down to 70 MV and 400 MV, respectively, and their differential variation in intensity with time has been monitored with unprecedented accuracy. These observations are used to show how differently electrons and protons responded to the quiet modulation conditions that prevailed from 2006 to 2009. It is well known that particle drifts, as one of four major mechanisms for the solar modulation of CRs, cause charge-sign-dependent solar modulation. Periods of minimum solar activity provide optimal conditions in which to study these drift effects. The observed behavior is compared to the solutions of a three-dimensional model for CRs in the heliosphere, including drifts. The numerical results confirm that the difference in the evolution of electron and proton spectra during the last prolonged solar minimum is attributed to a large extent to particle drifts. We therefore present new evidence of charge-sign-dependent solar modulation, with a perspective on its peculiarities for the observed period from 2006 to 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

Synthesis and luminescence properties of KSrPO{sub 4}:Eu{sup 2+} phosphor for radiation dosimetry

The KSrPO{sub 4}:Eu phosphor was synthesized via solid state method. The structural and morphological characterizations were done through XRD (X-ray diffraction) and SEM (Scanning Electronic Microscope). Additionally, the photoluminescence (PL), thermoluminescence (TL) and optically Stimulated luminescence (OSL) properties of powder KSrPO{sub 4}:Eu were studied. The PL spectra show blue emission under near UV excitation. It was advocated that KSrPO{sub 4}:Eu phosphor not only show OSL sensitivity (0.47 times) but also gives faster decay in OSL signals than that of Al{sub 2}O{sub 3}:C (BARC) phosphor. The TL glow curve consist of two shoulder peaks and the kinetics parameters such as activation energy and frequency factors were determined by using peak shape method and also photoionization cross-sections of prepared phosphor was calculated. The radiation dosimetry properties such as minimum detectable dose (MDD), dose response and reusability were reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Propagation of Chorus Waves Generated in Minimum‐B Pockets

Abstract We present the first ray tracing results of chorus waves generated in minimum‐B pockets. A new ray tracer is developed to accommodate an arbitrary magnetic field model, which enables us to construct minimum‐B pocket geometries using the Tsyganenko (1989) model. Rays with different frequencies and initial wave normal angles are launched from minimum‐B pockets and traced under different geomagnetic activity and hot electron density conditions. Our results indicate that chorus waves generated from minimum‐B pockets are usually highly localized and thus are unlikely to be detected unless the spacecraft is very close to the source region. These waves are also very unlikely to propagate into the plasmasphere. The propagation distances generally decrease with increasing geomagnetic activity.

Kang, Ning↗

TH-AB-209-02: Gadolinium Measurements in Human Bone Using in Vivo K X-Ray Fluorescence (KXRF) Technique

Purpose: Improvement in an in vivo K x-ray fluorescence system, based on 109Cd source, for the detection of gadolinium (Gd) in bone has been investigated. Series of improvements to the method is described. Gd is of interest because of the extensive use of Gd-based contrast agents in MR imaging and the potential toxicity of Gd exposure. Methods: A set of seven bone equivalent phantoms with different amount of Gd concentrations (from 0–100 ppm) has been developed. Soft tissue equivalent plastic plates were used to simulate the soft tissue overlaying the tibia bone in an in vivo measurement. A new 5 GBq 109Cd source was used to improve the source activity in comparison to the previous study (0.17 GBq). An improved spectral fitting program was utilized for data analysis. Results: The previous published minimum detection limit (MDL) for Gd doped phantom measurements using KXRF system was 3.3 ppm. In this study the MDL for bare bone phantoms was found to be 0.8 ppm. Our previous study used only three layers of plastic (0.32, 0.64 and 0.96 mm) as soft tissue equivalent materials and obtained the MDL of 4–4.8 ppm. In this study the plastic plates with more realistic thicknesses to simulate the soft tissue covering tibia bone (nine thicknesses ranging from 0.61–6.13 mm) were used. The MDLs for phantoms were determined to be 1.8–3.5 ppm. Conclusion: With the improvements made to the technology (stronger source, improved data analysis algorithm, realistic soft tissue thicknesses), the MDL of the KXRF system to measure Gd in bare bone was improved by a factor of 4.1. The MDL is at the level of the bone Gd concentration reported in literature. Hence, the system is ready to be tested on human subjects to investigate the use of bone Gd as a biomarker for Gd toxicity.

60 APPLIED LIFE SCIENCES↗

An efficient SAC-OCDMA system using three different codes with two different detection techniques for maximum allowable users

In this paper, three codes spectral amplitude coding optical code division multiple access (SAC-OCDMA) are proposed and compared in terms of system performance including bit error rate (BER), number of active users, high achievable data rate, high signal to noise ratio (SNR) and the minimum received power that the OCDMA system supports to achieve a minimum BER value. The proposed codes are diagonal double weight (DDW) codes, modified double weight (MDW) codes and enhanced double weight (EDW). Different detection as AND subtraction detection technique and single photodiode detection (SPD) are investigated to reduce the effect of both the multiple access interference and phase induced intensity noise. The obtained results show that SAC-OCDMA using EDW code with SPD detection can achieve large number users with better BER (~ 10{sup −9}), SNR (> 20 dB), and minimum received power (~ − 20 dBm) relative to the other codes with other detection techniques.

42 ENGINEERING↗

Assessing overall building energy performance of a large population of residential single-family homes using limited field data

The U.S. Department of Energy (DOE), through the Building Energy Codes Program (BECP), supports building energy code development and implementation processes to achieve the maximum practicable, cost-effective improvements in energy efficiency while providing safe, healthy buildings for occupants. Currently, there is a lack of statistically representative data that shows how energy codes are implemented in the field and the energy savings opportunities that exist. To address this gap, DOE initiated a research study targeted at new residential single-family homes in 8 states starting in the fall of 2014. The study comprises of a baseline phase to determine current levels of compliance with the key energy provisions of the residential building energy code, identify issues, and calculate potential energy savings from improved compliance; a second phase implementing education, training and outreach activities designed to increase targeted code compliance; and a post-study phase to measure the impact of the training and outreach activities compared to the baseline phase. Initial analyses determined the code requirements with the largest energy impact and the minimum number of observations required to detect statistically significant differences in energy use. Data was collected in the field during a single site visit to avoid bias from repeat visits. However, the single site visit principle prevented energy simulation of individual homes due to the lack of all required model inputs. To address this, energy simulation was conducted using Pacific Northwest National Laboratory’s prototype building models and employing bootstrap random sampling on the data collected from all homes visited. The modeled energy consumption using the observed field data was evaluated relative to that associated with the minimum code requirements and potential savings associated with improved compliance of select items were assessed. This paper discusses the methodology developed for this field study, and presents the results and findings from the baseline phase.

Xie, YuLong↗

Criticality Accident Alarm System Modeling for the Uranium Processing Facility

The Criticality Accident Alarm System (CAAS) for the Uranium Processing Facility (UPF) provides coverage for two primary processing facilities. For UPF, detailed documentation and drawings of the design are readily available. While this design information allows for some CAAS modeling features to match the actual design with a high level of accuracy, assumptions and simplifications are necessary as it is unrealistic and unnecessary to replicate many aspects of the design. A set of modeling guidelines and techniques were used to develop consistency between the MCNP6 models. While ensuring conservatism, overly conservative choices must be avoided to demonstrate the minimum accident of concern can be detected. To ensure proper modeling choices were made for the final models, a group of parametric studies were performed to evaluate the impact on the dose rates detected at the individual detectors. Some of these modeling choices and/or associated parametric studies include: - Modeling the grid steel area above the detectors as homogeneous stainless steel and determining the impact on detectability with an increasing density. - Modeling the presence of equipment in close proximity to the CAAS detectors. - Determining an appropriate material density to represent miscellaneous items not specifically modeled. - Evaluating the impact of sprinkler activation. The results of UPF CAAS analyses show that the modeling assumptions made based on the detailed design and parametric studies are appropriate and demonstrate accurate yet conservative models have been developed for detecting minimum accident of concern within the UPF.

61 RADIATION PROTECTION AND DOSIMETRY↗

Two new long-period giant planets from the McDonald Observatory planet search and two stars with long-period radial velocity signals related to stellar activity cycles

We report the detection of two new long-period giant planets orbiting the stars HD 95872 and HD 162004 (ψ{sup 1} Dra B) by the McDonald Observatory planet search. The planet HD 95872b has a minimum mass of 4.6 M{sub Jup} and an orbital semimajor axis of 5.2 AU. The giant planet ψ{sup 1} Dra Bb has a minimum mass of 1.5 M{sub Jup} and an orbital semimajor axis of 4.4 AU. Both of these planets qualify as Jupiter analogs. These results are based on over one and a half decades of precise radial velocity (RV) measurements collected by our program using the McDonald Observatory Tull Coude spectrograph at the 2.7 m Harlan J. Smith Telescope. In the case of ψ{sup 1} Dra B we also detect a long-term nonlinear trend in our data that indicates the presence of an additional giant planet, similar to the Jupiter–Saturn pair. The primary of the binary star system, ψ{sup 1} Dra A, exhibits a very large amplitude RV variation due to another stellar companion. We detect this additional member using speckle imaging. We also report two cases—HD 10086 and HD 102870 (β Virginis)—of significant RV variation consistent with the presence of a planet, but that are probably caused by stellar activity, rather than reflexive Keplerian motion. These two cases stress the importance of monitoring the magnetic activity level of a target star, as long-term activity cycles can mimic the presence of a Jupiter-analog planet.

79 ASTRONOMY AND ASTROPHYSICS↗

SATURATION LEVELS FOR WHITE-LIGHT FLARES OF FLARE STARS: VARIATION OF MINIMUM FLARE DURATION FOR SATURATION

Taking into account results obtained from models and from statistical analyses of obtained parameters, we discuss flare activity levels and flare characteristics of five UV Ceti stars. We present the parameters of unpublished flares detected over two years of observations of V1005 Ori. We compare parameters of the U-band flares detected over several seasons of observations of AD Leo, EV Lac, EQ Peg, V1054 Oph, and V1005 Ori. Flare frequencies calculated for all program stars and maximum energy levels of the flares are compared, and we consider which is the most correct parameter as an indicator of flare activity levels. Using the One Phase Exponential Association function, the distributions of flare equivalent duration versus flare total duration are modeled for each program star. We use the Independent Samples t-Test in the statistical analyses of the parameters obtained from the models. The results reveal some properties of flare processes occurring on the surfaces of UV Ceti type stars. (1) Flare energies cannot be higher than a specific value regardless of the length of the flare total duration. This must be a saturation level for white-light flares occurring in flare processes observed in the U band. Thus, for the first time it is shown that white-light flares have a saturation in a specific energy range. (2) The span values, which are the difference between the equivalent durations of flares with the shortest and longest total durations, are almost equal for each star. (3) The half-life values, minimum flare durations for saturation, increase toward the later spectral types. (4) Both maximum total durations and maximum rise times computed from the observed flares decrease toward the later spectral types among the UV Ceti stars. According to the maximum energy levels obtained from the models, both EV Lac and EQ Peg are more active than the other three program stars, while AD Leo is the most active flare star according to the flare frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

TWO 'b's IN THE BEEHIVE: THE DISCOVERY OF THE FIRST HOT JUPITERS IN AN OPEN CLUSTER

We report the discovery of two giant planets orbiting stars in Praesepe (also known as the Beehive Cluster). These are the first known hot Jupiters in an open cluster and the only planets known to orbit Sun-like, main-sequence stars in a cluster. The planets are detected from Doppler-shifted radial velocities; line bisector spans and activity indices show no correlation with orbital phase, confirming the variations are caused by planetary companions. Pr0201b orbits a V = 10.52 late F dwarf with a period of 4.4264 {+-} 0.0070 days and has a minimum mass of 0.540 {+-} 0.039 M{sub Jup}, and Pr0211b orbits a V = 12.06 late G dwarf with a period of 2.1451 {+-} 0.0012 days and has a minimum mass of 1.844 {+-} 0.064 M{sub Jup}. The detection of two planets among 53 single members surveyed establishes a lower limit of 3.8{sup +5.0}{sub -2.4}% on the hot Jupiter frequency in this metal-rich open cluster. Given the precisely known age of the cluster, this discovery also demonstrates that, in at least two cases, giant planet migration occurred within 600 Myr after formation. As we endeavor to learn more about the frequency and formation history of planets, environments with well-determined properties-such as open clusters like Praesepe-may provide essential clues to this end.

79 ASTRONOMY AND ASTROPHYSICS↗

Increasing the detection sensitivity of the Radionuclide Aerosol Sampler/Analyzer using a cosmic veto system

Different configurations of a cosmic veto system have been evaluated for the Radionuclide Aerosol Sampler/Analyzer (RASA). The upgrade has the potential to resolve the issue that U.S. IMS radionuclide stations have difficulty meeting the 140Ba Minimum Detectable Concentration (MDC) certification requirement when the natural background radioactivity is high. It also aims to improve the detection sensitivity of the RASA system for other fission and activation products indicative of a nuclear explosion. This proof of principal utilizes a prototype RASA system located at Pacific Northwest National Laboratory (PNNL), and has demonstrated background reductions by up to 11.3% and improvements in the average MDC by up to 7.7%. Recommendations are made for either a 1 or 3 plate configuration, which improves the 140Ba MDC by 5.6% and 7.2% for a blank filter. Whilst elevated 212Pb activity remains problematic, the cosmic veto system provides a practical solution for sensitivity improvement with little design modification of the RASA. It also has value in improving sensitivity and preventing false-positives at remote U.S. IMS station locations where sample transfer for laboratory analysis is logistically difficult.

Comprehensive Nuclear-Test-Ban Treaty, RASA, Cosmi↗

Physical nature and timing variations of the eclipsing system V407 Pegasi

New multiband CCD photometry is presented for V407 Peg; the R {sub C} light curves are the first ever compiled. Our light curves, displaying a flat bottom at secondary minimum and an O'Connell effect, were simultaneously analyzed with the radial velocity (RV) curves given by Rucinski et al. The light changes of the system are best modeled using both a hot spot on the secondary star and a third light. The model also represents historical light curves. All available minimum epochs, including our six timing measurements, have been examined and they indicate that the eclipse timing variation is mainly caused by light asymmetries due to the spot activity detected in the light-curve synthesis. The hot spot may be produced as a result of the impact of the gas stream from the primary star. Our light and velocity solutions indicate that V407 Peg is a totally eclipsing A-type overcontact binary with values of q = 0.251, i = 87.°6, ΔT = 496 K, f = 61%, and l {sub 3} = 11∼16%. Individual masses and radii of both components are determined to be M {sub 1} = 1.72 M {sub ☉}, M {sub 2} = 0.43 M {sub ☉}, R {sub 1} = 2.15 R {sub ☉}, and R {sub 2} = 1.21 R {sub ☉}. These results are very different from previous ones, which is probably caused by the light curves with distorted and inclined eclipses used in those other analyses. The fact that there are no objects optically related to the system and that the seasonal RVs show a large discrepancy in systemic velocity indicates that the third light source most likely arises from a tertiary component orbiting the eclipsing pair.

79 ASTRONOMY AND ASTROPHYSICS↗

Effective field theory analysis of the first LUX dark matter search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10 -46 cm 2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 10 4 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-512: Intrinsic Characteristics of the Nine Detectors and Evaluation of Their Performance in Non-Equilibrium Radiation Dosimetry

Purpose The aim for the study was to compare intrinsic characteristics of the nine detectors and evaluate their performance in non-equilibrium radiation dosimetry. Methods The intrinsic characteristics of the nine detectors that were evaluated are based on the composition and size of the active volume, operating voltage, initial recombination of the collected charge, temperature, the effective cross section of the detectors. The shortterm stability and collection efficiency has been investigated. The minimum radiation detection sensitivity and detectors leakage current has been measured. The sensitivity to changes in energy spectrum as well as change in incident beam angles were measured an analyzed. Results The short-term stability of the measurements within every detector showed consistency in the measured values with the highest value of the standard deviation of the mean not exceeding 0.5%. Air ion chamber detectors showed minimum sensitivity to change in incident beam angles while diode detectors underestimated measurements up to 16%. Comparing the slope of the tangents for detector’s sensitivity curve, diode detectors illustrate more sensitivity to change in photon spectrum than ion chamber detectors. The change in radiation detection sensitivity with increase in dose delivered has been observed for semiconductor detectors with maximum deviation 0.01% for doses between 1 Gy and 10 Gy. Leakage current has been mainly influenced by bias voltage (ion chamber detectors) and room light intensity (diode detectors). With dose per pulse varying from 1.47E−4 to 5.1E−4 Gy/pulse the maximum change in collection efficiency was 1.4% for the air ion chambers up to 8% for liquid filled ion chamber. Conclusion Broad range of measurements performed showed all the detectors susceptible to some limitations and while they are suitable for use in broad scope of applications, careful selection has to be made for particular range of measurements.

60 APPLIED LIFE SCIENCES↗

Disentangling Centrality Bias and Final-State Effects in the Production of High-𝑝 𝑇 Neutral Pions Using Direct Photon in 𝑑+Au Collisions at $\sqrt{s_{NN}}$ = 200 GeV

Here, PHENIX presents a simultaneous measurement of the production of direct 𝛾 and 𝜋 0 in 𝑑 + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV over a 𝑝 𝑇 range of 7.5 to 18 GeV/𝑐 for different event samples selected by event activity, i.e., charged-particle multiplicity detected at forward rapidity. Direct-photon yields are used to empirically estimate the contribution of hard-scattering processes in the different event samples. Using this estimate, the average nuclear-modification factor, 𝑅$^{𝜋^0}_{dAu,EXP}$, is 0.925 ± 0.023⁢(stat) ± 0.15⁢(scale), consistent with unity for minimum-bias (MB) 𝑑+Au collisions. For event classes with low and moderate event activity, 𝑅$^{𝜋^0}_{dAu,EXP}$ is consistent with the MB value within 5% uncertainty. This result confirms that the previously observed enhancement of high-𝑝 𝑇 𝜋 0 production found in small-system collisions with low event activity is a result of a bias in interpreting event activity within the Glauber framework. In contrast, for the top 5% of events with the highest event activity, 𝑅$^{𝜋^0}_{dAu,EXP}$ is suppressed by 20% relative to the MB value with a significance of 4.5⁢𝜎, which may be due to final-state effects. This suppression corresponds to a 𝑝 𝑇 shift of 𝛿⁢𝑝 𝑇 = 0.213 ± 0.055 Gev/𝑐 at 9 Gev/𝑐.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Welding of Haynes 282 to Steels to Enable Modular Rotors for Advanced Ultra Super-Critical Steam Turbines

Steam turbines for an Advanced Ultra Super Critical (AUSC) fossil fired power plant will operate at temperatures well above those of current commercial steam cycles with inlet temperatures more than 760 C , which is beyond the capabilities of alloy steels presently used for steam turbine applications and requires advanced materials. Large components such as steam turbine rotors may be made of nickel based super alloys such as Haynes 282 (H282). However, monolithic forgings of superalloys in the sizes required for large steam turbines rotors can be prohibitively expensive besides many technical challenges. To minimize cost and alleviate the related technical challenges, superalloy use needs to be limited to locations on the steam turbine rotor where strength and temperature requirements cannot be met by conventional steels. This is possible if nickel-based superalloys can be successfully welded to steels and the related technical challenges - machining parts made of dissimilar welded materials, non-destructive examination of such welds for flaw detection; and, material properties of such hybrid components – are sufficiently addressed. In this technology development project, we successfully welded H282 to plates up to ~ 75 mm (~ 3 inches) to a 3.5NiCrMoV steel of similar thickness. Advanced ultrasonic inspection technique called Phased Array Ultrasonic Testing (PAUT) was employed to examine the dissimilar H282-Steel welds, into which flat bottomed side drilled holes (SDH) of various diameters were introduced, to determine the minimum detectable feature sizes; it was shown that with PAUT SDH of dia. down to 0.5 mm could be detected in the base alloys and SDH with dia. down to 2.4 mm could be detected in the weld metal under multiple orientations successfully. An autonomous machining process monitoring system was developed and demonstrated whereby the forces acting on the cutting tool could be actively monitored as the cutting tool transitioned from H282 to Steel across the weld using which the machining parameters can be potentially altered without interruption to extend tool life. This project successfully achieved its objectives of - i. Developing a welding methodology and viable welding geometries, to successfully join H282 to steel 3.5CrMoNiV steel to enable manufacture of modular steam turbine rotors for AUSC applications (conditions of at least 760 °Celsius and 3,100 psia (pounds per square inch absolute pressure) and evaluate the material properties of the welded specimen. ii. Employ the advanced ultrasonic inspection technique to the dissimilar weld metal joint and determine the minimum detectable feature sizes. iii. Develop effective machining techniques to machine such hybrid structures with online tool force monitoring and effect machine state metrics for optimal results.

20 FOSSIL-FUELED POWER PLANTS↗

TL/OSL properties of beta irradiated Al2O3:Tm3+ phosphor synthesized by microwave combustion method

Highlights: • TL emission spectra of γ – rayed Al{sub 2}O{sub 3}:Tm{sup 3+} shows Tm{sup 3+} characteristic transitions. • Doping of Tm{sup 3+} ions causes enhancement of TL/OSL. • TL/OSL kinetic parameters are analyzed by CGCD method. • TL mechanism of γ/β – rayed Al{sub 2}O{sub 3}:Tm{sup 3+} was proposed. • TL/OSL dosimetric properties of Al{sub 2}O{sub 3}:Tm{sup 3+} suggests that the material is appropriate for medical dosimetry. - Abstract: This work discusses synthesis of stable α-phase of Al{sub 2}O{sub 3}:Tm{sup 3+} by combustion method using temperature controlled microwave oven. The crystalline phase was analyzed by X-ray diffraction (XRD) technique and average crystallite size was found to be 147 nm. Observations using scanning electron microscope (SEM) image suggest formation of agglomerated particles and energy dispersive x-ray spectroscopy (EDS) confirmed the incorporation of Tm{sup 3+} in Al{sub 2}O{sub 3}. Thermoluminescence emission (TLE) spectrum of γ – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} shows characteristic emissions of Tm{sup 3+}, Cr{sup 3+} and Mn{sup 4+}. TL glow curves of γ – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} exhibit a prominent peak at 453 K along with a shoulder at 496 K. The glow curves of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} were studied in different emission regions using U340 + BG39 (UV band pass), CS759 + BG39 (Blue band pass) and BG39 (Visible band pass) optical glass filters. A prominent peak was observed at 471 K in for all mentioned emission regions and an additional shoulder was observed at 511 K with CS759 + BG39 and BG39 filters. TL glow curve of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} using only BG39 filter had more counts than CS759 + BG39 and U340 + BG39 filters. Further, the effect of Tm{sup 3+} impurity on TL response was studied. TL kinetic parameters were estimated by using computerized glow curve deconvolution (CGCD) technique. The activation energy and frequency factor of prominent peak (471 K) were found to be 1.31 eV and 3.50 × 10{sup 13} s{sup −1} respectively. Optically stimulated luminescence (OSL) characteristics of β – irradiated Al{sub 2}O{sub 3}:Tm{sup 3+} were studied using U340 + BG39 and CS759 + BG39 filters. Highest OSL intensity was observed in UV. OSL curves were deconvoluted by general order decay equation. Life time and photoionization cross section of the traps responsible for OSL were found to be 5.30 s and 3.98 × 10{sup −18} cm{sup 2} respectively. The process of ionization of electron from Tm{sup 3+}, electron trap in host lattice and its recombination mechanism is proposed. Phosphorescence decay of beta irradiated sample was also studied. The lifetime of phosphorescence decay was found to be 140 s for the prominent peak and TL intensity decays 25% after the phosphorescence. TL/OSL dosimetric properties viz. linearity with dose, reusability and minimum detectable dose of the phosphor were characterized for medical dosimetry application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗