Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design, Fabrication and Testing of Multilayer Coated X-Ray Optics for the Water Window Imaging X-Ray Microscope

Hoover et. al. built and tested two imaging Schwarzschild multilayer microscopes. These instruments were constructed as prototypes for the "Water Window Imaging X-Ray Microscope," which is a doubly reflecting, multilayer x-ray microscope configured to operate within the "water window." The "water window" is the narrow region of the x-ray spectrum between the K absorption edges of oxygen (lamda = 23.3 Angstroms) and of carbon (lamda = 43.62 Angstroms), where water is relatively highly transmissive and carbon is highly absorptive. This property of these materials, thus permits the use of high resolution multilayer x-ray microscopes for producing high contrast images of carbon-based structures within the aqueous physiological environments of living cells. We report the design, fabrication and testing of multilayer optics that operate in this regime.

Spencer, Dwight C.↗

Sedimentological Investigations of the Martian Surface using the Mars 2001 Robotic Arm Camera and MECA Optical Microscope

The first microscopic sedimentological studies of the Martian surface will commence with the landing of the Mars Polar Lander (MPL) December 3, 1999. The Robotic Arm Camera (RAC) has a resolution of 25 um/p which will permit detailed micromorphological analysis of surface and subsurface materials. The Robotic Ann will be able to dig up to 50 cm below the surface. The walls of the trench will also be inspected by RAC to look for evidence of stratigraphic and / or sedimentological relationships. The 2001 Mars Lander will build upon and expand the sedimentological research begun by the RAC on MPL. This will be accomplished by: (1) Macroscopic (dm to cm): Descent Imager, Pancam, RAC; (2) Microscopic (mm to um RAC, MECA Optical Microscope (Figure 2), AFM This paper will focus on investigations that can be conducted by the RAC and MECA Optical Microscope.

Rice, J. W., Jr.↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗

Geometrically Matched Multi-source Microscopic Image Synthesis Using Bidirectional Adversarial Networks

Microscopic images from multiple modalities can produce plentiful experimental information. In practice, biological or physical constraints under a given observation period may prevent researchers from acquiring enough microscopic scanning. Recent studies demonstrate that image synthesis is one of the popular approaches to release such constraints. Nonetheless, most existing synthesis approaches only translate images from the source domain to the target domain without solid geometric associations. To embrace this challenge, we propose an innovative model architecture, BANIS, to synthesize diversified microscopic images from multi-source domains with distinct geometric features. The experimental outcomes indicate that BANIS successfully synthesizes favorable image pairs on C. elegans microscopy embryonic images. To the best of our knowledge, BANIS is the first application to synthesize microscopic images that associate distinct spatial geometric features from multi-source domains.

Wang, Dali↗

3-D Magnetization Mapping Microscope (360 video)

Science in 360°: The incredibly complex device in this video is one of the few electron microscopes worldwide that can image magnetization in 3-D, which is key to improving materials for computer memory devices. Located at Berkeley Lab's Molecular Foundry, the microscope is called SPLEEM (Spin-Polarized Low Energy Electron Microscope), and it’s one of the many reasons that scientists from around the world come to the Foundry.

47 OTHER INSTRUMENTATION↗

Investigating Dissolution and Precipitation Phenomena with a Smartphone Microscope

A novel smartphone microscope can be used to observe the dissolution and crystallization of sodium chloride at a microscopic level. Observation of these seemingly simple phenomena through the microscope at 100× magnification can actually reveal some surprising behavior. These experiments offer the opportunity to discuss some basic concepts such as how the morphological features of the crystals dictates how the dissolution process proceeds, and how materials can be purified by re-crystallization techniques.

36 MATERIALS SCIENCE↗

The National Ignition Facility modular Kirkpatrick-Baez microscope

Current two-dimensional X-ray imaging at the National Ignition Facility (NIF) uses time resolved pinhole cameras with ∼10-25 μm pinholes. This method has limitations in the smallest resolvable features that can be imaged with reasonable photon statistics for inertial confinement fusion (ICF) applications. ICF sources have a broadband self-emission spectrum that causes the pinhole images obtained, through thin foil filters, to contain a similarly broadband spectrum complicating the interpretation of structure in the source. In order to study phenomena on the scale of ∼5 μm, such as dopant mix in the ICF capsule, a narrow energy band, higher spatial resolution microscope system with improved signal/noise has been developed using X-ray optics. Utilizing grazing incidence mirrors in a Kirkpatrick-Baez microscope (KBM) configuration [P. Kirkpatrick and A. V. Baez, J. Opt. Soc. Am. 38, 766–774 (1948)], an X-ray microscope has been designed and fielded on NIF with four imaging channels. The KBM has ∼12 × magnification, <8 μm resolution, and higher throughput in comparison to similar pinhole systems. The first KBM mirrors are coated with a multilayer mirror to allow a “narrow band” energy response at 10.2 keV with ΔE ∼ 3 keV. By adjusting the mirror coating only, the energy response can be matched to the future experimental requirements. Several mirror packs have been commissioned and are interchangeable in the diagnostic snout.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Features of Construction of the Fluorescent Microscope for the Study of Epithelial-Mesenchymal Transition of Cells in Vitro

An optical luminescent microscope has been developed to monitor the behavior of tumor cells that were modified by GFP and RFP fluorescent proteins and to monitor the formation of metastases in biochips. Images of cells in the light of GFP and RFP fluorescence proteins, as well as in the photography mode, are recorded in the microscope by an noncooled CMOS matrix at the excitation of luminescence by blue and green LEDs and illumination of cells with white LEDs, respectively. The obtained fluorescent images and photos in white light are recorded by the matrix in the same coordinate system and do not require additional processing for combination. The power of irradiation of cells with LEDs does not exceed 50 μW/mm{sup 2} at an exposure time of 1 s, which is an order of magnitude lower than the radiation power causing photodestruction and phototoxicity of cells during long-term studies. Relative parameters of the optical channel of the luminescent microscope have been introduced that allow comparing the sensitivity of the recording system and the minimum power level of the radiation that excites luminescence for optical elements with different spectral characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CHAMP (Camera, Handlens, and Microscope Probe)

CHAMP (Camera, Handlens And Microscope Probe)is a novel field microscope capable of color imaging with continuously variable spatial resolution from infinity imaging down to diffraction-limited microscopy (3 micron/pixel). As a robotic arm-mounted imager, CHAMP supports stereo imaging with variable baselines, can continuously image targets at an increasing magnification during an arm approach, can provide precision rangefinding estimates to targets, and can accommodate microscopic imaging of rough surfaces through a image filtering process called z-stacking. CHAMP was originally developed through the Mars Instrument Development Program (MIDP) in support of robotic field investigations, but may also find application in new areas such as robotic in-orbit servicing and maintenance operations associated with spacecraft and human operations. We overview CHAMP'S instrument performance and basic design considerations below.

robotic field investigations↗

Microscopic Theory of Nuclear Fission

Nuclear fission represents the ultimate test for microscopic theories of nuclear structure and reactions. Fission is a large-amplitude, time-dependent phenomenon taking place in a self-bound, strongly interacting many-body system. It should, at least in principle, emerge from the complex interactions of nucleons within the nucleus. The goal of microscopic theories is to build a consistent and predictive theory of nuclear fission by using as only ingredients protons and neutrons, nuclear forces, and quantum many-body methods. Thanks to a constant increase in computing power, such a goal has never seemed more within reach. This chapter gives an overview both of the set of techniques used in microscopic theories to describe the fission process and of some recent successes achieved by this class of methods.

Nuclear physics and radiation physics↗

Solving macroscopic and microscopic pin-fin heat sink problems by adapted spectral method

In this paper, simulation of heat transfer in a heat sink with macroscopic and microscopic scales when one pin-fin is added to the system is investigated by the proposed spectral method. In the microscopic problems, heat transfer model uses dual-phase lag formulas in contrast with macroscopic problems when Fourier law is used to formulate the governing equation. In macroscopic problem, the results are compared with COMSOL multiphysics software results and a good agreement between the results are shown. In microscopic problems, 3D Gaussian heat source is used and boundary conditions obey the Newton law. Comparisons show the efficiency of the current method, while the results are compared with existed literature. It is shown that: by adding one pin fin to the heat sink problem, temperature of the system will decrease. Numerical results are given and graphs of the temperature for various kinds of pin-fin heat sink problems are depicted.

97 MATHEMATICS AND COMPUTING↗

Universal aging characteristics of macroscopically and microscopically dissimilar metallic glasses

Supercooled liquids and glasses, due to their intrinsically unstable nature, are known to relax continuously until an equilibrium state is reached. By exploring atomic relaxation, aging and microscopic structure of chemically similar but physically dissimilar metallic glasses, we find that neither the relaxation time nor aging correlate with the free volume or density of the glasses. Furthermore, atomic relaxation time in these metallic glasses does not depend on the microscopic structure of the systems. The activation energy for the diffusion process indicates a completely different microscopic mechanism governing the atomic transport process. Nevertheless, the age-dependent relaxation time surprisingly exhibits a universal time-waiting time-temperature superposition. In conclusion, our results provide a convincing proof of the universality in the aging of out-of-equilibrium materials.

36 MATERIALS SCIENCE↗

Macroscopic instructions vs microscopic operations in quantum circuits

In many experiments on microscopic quantum systems, it is implicitly assumed that when a macroscopic procedure or “instruction” is repeated many times – perhaps in different contexts – each application results in the same microscopic quantum operation. But in practice, the microscopic effect of a single macroscopic instruction can easily depend on its context. If undetected, this can lead to unexpected behavior and unreliable results. Here, we design and analyze several tests to detect context-dependence. They are based on invariants of matrix products, and while they can be as data intensive as quantum process tomography, they do not require tomographic reconstruction, and are insensitive to imperfect knowledge about the experiments. We also construct a measure of how unitary (reversible) an operation is, and show how to estimate the volume of physical states accessible by a quantum operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hartmann characterization of the PEEM-3 aberration-corrected X-ray photoemission electron microscope

Aberration correction by an electron mirror dramatically improves the spatial resolution and transmission of photoemission electron microscopes. We will review the performance of the recently installed aberration corrector of the X-ray Photoemission Electron Microscope PEEM-3 and show a large improvement in the efficiency of the electron optics. Hartmann testing is introduced as a quantitative method to measure the geometrical aberrations of a cathode lens electron microscope. Here, we find that aberration correction leads to an order of magnitude reduction of the spherical aberrations, suggesting that a spatial resolution of below 100 nm is possible at 100% transmission of the optics when using x-rays. We demonstrate this improved performance by imaging test patterns employing element and magnetic contrast.

36 MATERIALS SCIENCE↗

Microscopic Dynamics Controls Coupling and Cluster Formation in Brush Particle Solids

Thermodynamics-based models predict the structure of polymer-grafted nanoparticles (PGNs) as well as their assembly behavior based on geometric parameters such as particle size, degree of polymerization, and density of grafted chains. The role of microscopic polymer dynamics, such as the mobility of repeat units in the melt state, in the evolution of the structure and properties remains unknown. Brillouin light spectroscopy (BLS), due to its capability to concurrently discern the local and global elastic properties of PGN assemblies, enables the probing of microscopic processes, such as brush interdigitation, sensitive to the annealing of the assembly. For poly(methyl methacrylate) (PMMA)-grafted silica (SiO 2 ) PGNs in the dry powder state and annealed above the glass transition temperature, BLS revealed fully reversible local elasticity, indicative of limited interdigitation between adjacent PGNs. This contrasts with polystyrene (PS)−SiO 2 analogs that displayed ready (and irreversible) fusion of brush layers during annealing. The retardation of brush interdigitation in PMMA-grafted systems is surprising, given the similar thermomechanical properties of both polymers, and is rationalized as the consequence of higher friction between PMMA repeats compared to PS. Microscopic dynamics thus has a profound impact on the kinetic path of structure (and property) evolution and thus should be considered during the processing of PGNs into functional hybrid materials.

chemical structure↗

Microscopic Manipulation of Ferroelectric Domains in SnSe Monolayers at Room Temperature

Two-dimensional (2D) van der Waals ferroelectrics provide an unprecedented architectural freedom for the creation of artificial multiferroics and nonvolatile electronic devices based on vertical and coplanar heterojunctions of 2D ferroic materials. Nevertheless, controlled microscopic manipulation of ferroelectric domains is still rare in monolayer-thick 2D ferroelectrics with in-plane polarization. Here we report the discovery of robust ferroelectricity with a critical temperature close to 400 K in SnSe monolayer plates grown on graphene and the demonstration of controlled room-temperature ferroelectric domain manipulation by applying appropriate bias voltage pulses to the tip of a scanning tunneling microscope (STM). This study shows that STM is a powerful tool for detecting and manipulating the microscopic domain structures in 2D ferroelectric monolayers, which are difficult for conventional approaches such as piezoresponse force microscopy, thus facilitating the hunt for other 2D ferroelectric monolayers with in-plane polarization with important technological applications.

2D ferroelectric↗

Many-Body State Description of Single-Molecule Electroluminescence Driven by a Scanning Tunneling Microscope

Electron transport and optical properties of a single molecule in contact with conductive materials have attracted considerable attention because of their scientific importance and potential applications. With the recent progress in experimental techniques, especially by virtue of scanning tunneling microscope (STM)-induced light emission, where the tunneling current of the STM is used as an atomic-scale source for induction of light emission from a single molecule, it has become possible to investigate single-molecule properties at subnanometer spatial resolution. Despite extensive experimental studies, the microscopic mechanism of electronic excitation of a single molecule in STM-induced light emission has yet to be clarified. Here we present a formulation of single-molecule electroluminescence driven by electron transfer between a molecule and metal electrodes based on a many-body state representation of the molecule. The effects of intramolecular Coulomb interaction on conductance and luminescence spectra are investigated using the nonequilibrium Hubbard Green’s function technique combined with first-principles calculations. We compare simulation results with experimental data and find that the intramolecular Coulomb interaction is crucial for reproducing recent experiments for a single phthalocyanine molecule. The developed theory provides a unified description of the electron transport and optical properties of a single molecule in contact with metal electrodes driven out of equilibrium, and thereby, it contributes to a microscopic understanding of optoelectronic conversion in single molecules on solid surfaces and in nanometer-scale junctions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microscopic Origins of the Nonlinear Behavior of Particle-Filled Rubber Probed with Dynamic Strain XPCS

The underlying microscopic response of filler networks in reinforced rubber to dynamic strain is not well understood due to the experimental difficulty of directly measuring filler network behavior in samples undergoing dynamic strain. This difficulty can be overcome with in situ X-ray photon correlation spectroscopy (XPCS) measurements. The contrast between the silica filler and the rubber matrix for X-ray scattering allows us to isolate the filler network behavior from the overall response of the rubber. This in situ XPCS technique probes the microscopic breakdown and reforming of the filler network structure, which are responsible for the nonlinear dependence of modulus on strain, known in the rubber science community as the Payne effect. These microscopic changes in the filler network structure have consequences for the macroscopic material performance, especially for the fuel efficiency of tire tread compounds. In this work, we elucidate the behavior with in situ dynamic strain XPCS experiments on industrially relevant, vulcanized rubbers filled (13 vol %) with novel air-milled silica of ultrahigh-surface area (UHSA) (250 m 2 /g). The addition of a silane coupling agent to rubber containing this silica causes an unexpected and counterintuitive increase in the Payne effect and decrease in energy dissipation. For this rubber, we observe a nearly two-fold enhancement of the storage modulus and virtually equivalent loss tangent compared to a rubber containing a coupling agent and conventional silica. Interpretation of our in situ XPCS results simultaneously with interpretation of traditional dynamic mechanical analysis (DMA) strain sweep experiments reveals that the debonding or yielding of bridged bound rubber layers is key to understanding the behavior of rubber formulations containing the silane coupling agent and high-surface area silica. These results demonstrate that the combination of XPCS and DMA is a powerful method for unraveling the microscale filler response to strain which dictates the dynamic mechanical properties of reinforced soft matter composites. With this combination of techniques, we have elucidated the great promise of UHSA silica when used in concert with a silane coupling agent in filled rubber. Such composites simultaneously exhibit large moduli and low hysteresis under dynamic strain.

36 MATERIALS SCIENCE↗