Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics

A fully integrated, miniaturized analysis system for ions based on a centrifugal microfluidics platform and ion-selective optode membranes is described. The microfluidic architecture is composed of channels, five solution reservoirs, a measuring chamber, and a waste reservoir manufactured onto a disk-shaped substrate of poly(methyl methacrylate). Ion-selective optode membranes, composed of plasticized poly(vinyl chloride) impregnated with an ionophore, a proton chromoionophore, and a lipophilic anionic additive, were cast, with a spin-on device, onto a support layer and then immobilized on the disk. Fluid propulsion is achieved by the centrifugal force that results from spinning the disk, while a system of valves is built onto the disk to control flow. These valves operate based on fluid properties and fluid/substrate interactions and are controlled by the angular frequency of rotation. With this system, we have been able to deliver calibrant solutions, washing buffers, or "test" solutions to the measuring chamber where the optode membrane is located. An analysis system based on a potassium-selective optode has been characterized. Results indicate that optodes immobilized on the platform demonstrate theoretical responses in an absorbance mode of measurement. Samples of unknown concentration can be quantified to within 3% error by fitting the response function for a given optode membrane using an acid (for measuring the signal for a fully protonated chromoionophore), a base (for fully deprotonated chromoionophore), and two standard solutions. Further, the ability to measure ion concentrations by employing one standard solution in conjunction with acid and base and with two standards alone were studied to delineate whether the current architecture could be simplified. Finally, the efficacy of incorporating washing steps into the calibration protocol was investigated.

NASA Discipline Life Sciences Technologies↗

Experimental Microfluidic System

The ultimate goal of this project is to integrate microfluidic devices with NASA's space bioreactor systems. In such a system, the microfluidic device would provide realtime feedback control of the bioreactor by monitoring pH, glucose, and lactate levels in the cell media; and would provide an analytical capability to the bioreactor in exterrestrial environments for monitoring bioengineered cell products and health changes in cells due to environmental stressors. Such integrated systems could be used as biosentinels both in space and on planet surfaces. The objective is to demonstrate the ability of microfabricated devices to repeatedly and reproducibly perform bead cytometry experiments in micro, lunar, martian, and hypergravity (1.8g).

Culbertson, Christopher↗

Design and Modelling of a Microfluidic Electro-Lysis Device with Controlling Plates

Many Lab-on-Chip applications require sample pre-treatment systems. Using electric fields to perform cell-lysis in bio-MEMS systems has provided a powerful tool which can be integrated into Lab-on-a-Chip platforms. The major design considerations for electro-lysis devices include optimal geometry and placement of micro-electrodes, cell concentration, flow rates, optimal electric field (e.g. pulsed DC vs. AC), etc. To avoid electrolysis of the flowing solution at the exposed electrode surfaces, magnitudes and the applied voltages and duration of the DC pulse, or the AC frequency of the AC, have to be optimized for a given configuration. Using simulation tools for calculation of electric fields has proved very useful, for exploring alternative configurations and operating conditions for achieving electro cell-lysis. To alleviate the problem associated with low electric fields within the microfluidics channel and the high voltage demand on the contact electrode strips, two "control plates" are added to the microfluidics configuration. The principle of placing the two controlling plate-electrodes is based on the electric fields generated by a combined insulator/dielectric (gladwater) media. Surface charges are established at the insulator/dielectric interface. This paper discusses the effects of this interface charge on the modification of the electric field of the flowing liquid/cell solution.

Jenkins, A.↗

Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves

A microfluidic system has been designed to survive spaceflight and to function autonomously on the Martian surface. It manipulates microscopic quantities of liquid water and performs chemical analyses on these samples to assay for the presence of molecules associated with past or present living processes. This technology lies at the core of the Urey Instrument, which is scheduled for inclusion on the Pasteur Payload of the ESA ExoMars rover mission in 2013. Fabrication processes have been developed to make the microfabricated Teflon-AF microfluidic diaphragm pumps capable of surviving extreme temperature excursions before and after exposure to liquid water. Two glass wafers are etched with features and a continuous Teflon membrane is sandwiched between them (see figure). Single valves are constructed using this geometry. The microfabricated devices are then post processed by heating the assembled device while applying pneumatic pressure to force the Teflon diaphragm against the valve seat while it is softened. After cooling the device, the embossed membrane retains this new shape. This solves previous problems with bubble introduction into the fluid flow where deformations of the membrane at the valve seat occurred during device bonding at elevated temperatures (100-150 C). The use of laminated membranes containing commercial Teflon AF 2400 sheet sandwiched between spun Teflon AF 1600 layers performed best, and were less gas permeable than Teflon AF 1600 membranes on their own. Spinning Teflon AF 1600 solution (6 percent in FLOURINERT(Registered TradeMark) FC40 solvent, 3M Company) at 500 rpm for 1.5 seconds, followed by 1,000 rpm for 3 seconds onto Borofloat glass wafers, results in a 10-micron-thick film of extremely smooth Teflon AF. This spinning process is repeated several times on flat, blank, glass wafers in order to gradually build a thick, smooth membrane. After running this process at least five times, the wafer and Teflon coating are heated under vacuum at 220 C for one hour in order to drive off any residual solvent present in the composite film. After this, a second blank, glass wafer is brought down from above and the stack is held under vacuum at 3 atm mechanical pressure for ten 10 hours.

Willis, Peter↗

Microfluidics, Chromatography, and Atomic-Force Microscopy

A Raman-and-atomic-force microscope (RAFM) has been shown to be capable of performing several liquid-transfer and sensory functions essential for the operation of a microfluidic laboratory on a chip that would be used to perform rapid, sensitive chromatographic and spectro-chemical analyses of unprecedentedly small quantities of liquids. The most novel aspect of this development lies in the exploitation of capillary and shear effects at the atomic-force-microscope (AFM) tip to produce shear-driven flow of liquids along open microchannels of a microfluidic device. The RAFM can also be used to perform such functions as imaging liquids in microchannels; removing liquid samples from channels for very sensitive, tip-localized spectrochemical analyses; measuring a quantity of liquid adhering to the tip; and dip-pen deposition from a chromatographic device. A commercial Raman-spectroscopy system and a commercial AFM were integrated to make the RAFM so as to be able to perform simultaneous topographical AFM imaging and surface-enhanced Raman spectroscopy (SERS) at the AFM tip. The Raman-spectroscopy system includes a Raman microprobe attached to an optical microscope, the translation stage of which is modified to accommodate the AFM head. The Raman laser excitation beam, which is aimed at the AFM tip, has a wavelength of 785 nm and a diameter of about 5 m, and its power is adjustable up to 10 mW. The AFM is coated with gold to enable tip-localized SERS.

Anderson, Mark↗

Fabricating PFPE Membranes for Microfluidic Valves and Pumps

A process has been developed for fabricating membranes of a perfluoropolyether (PFPE) and integrating them into valves and pumps in laboratory-on-achip microfluidic devices. Membranes of poly(tetrafluoroethylene) [PTFE] and poly(dimethylsilane) [PDMS] have been considered for this purpose and found wanting. By making it possible to use PFPE instead of PTFE or PDMS, the present process expands the array of options for further development of microfluidic devices for diverse applications that could include detection of biochemicals of interest, detection of toxins and biowarfare agents, synthesis and analysis of proteins, medical diagnosis, and synthesis of fuels.

Greer, Frank↗

Plumbing Fixture for a Microfluidic Cartridge

A fixture has been devised for making the plumbing connections between a microfluidic device in a replaceable cartridge and an external fluidic system. The fixture includes a 0.25-in. (6.35-mm) thick steel plate, to which the cartridge is fastened by two 10-32 thumb screws. The plate holds one plumbing fitting for the inlet and one for the outlet of the microfluidic device. Each fitting includes a fused-silica tube of 0.006-in. (approx.0.15-mm) inside diameter within a fluorinated ethylene-propylene (FEP) tube of 0.0155-in. (approx.0.39-mm) inside diameter and 0.062- in. (approx.1.57-mm) outside diameter. The FEP tube is press-fit through the steel plate so that its exposed end is flush with the surface of the plate, and the silica tube protrudes 0.03 in. (approx.0.76 mm) from the plate/FEP-tube-end surface. The cartridge includes a glass cover plate that contains 0.06-mm-wide access ports. When the cartridge is fastened to the steel plate, the silica tubes become inserted through the access ports and into the body of the cartridge, while the ends of the FEP tubes become butted against the glass cover plate. An extremely tight seal is thereby made.

Francis, Kevin↗

Digital Microfluidics Sample Analyzer

Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.

Pollack, Michael G.↗

Microfluidic device for drug delivery

A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

Beebe, David J.↗

Method for using magnetic particles in droplet microfluidics

Methods of utilizing magnetic particles or beads (MBs) in droplet-based (or digital) microfluidics are disclosed. The methods may be used in enrichment or separation processes. A first method employs the droplet meniscus to assist in the magnetic collection and positioning of MBs during droplet microfluidic operations. The sweeping movement of the meniscus lifts the MBs off the solid surface and frees them from various surface forces acting on the MBs. A second method uses chemical additives to reduce the adhesion of MBs to surfaces. Both methods allow the MBs on a solid surface to be effectively moved by magnetic force. Droplets may be driven by various methods or techniques including, for example, electrowetting, electrostatic, electromechanical, electrophoretic, dielectrophoretic, electroosmotic, thermocapillary, surface acoustic, and pressure.

Shah, Gaurav Jitendra↗

Microfluidic Icy-World Chemical Analyzer

Measurements made with the Wet Chemistry Laboratory (WCL), including oxidation-reduction potential (E h ), regolith/soil pH, stable oxidants relevant to chemosynthetic metabolism (e.g., perchlorate, sulfate), and strong electrolytes were key to understanding habitability at the Phoenix Mars landing site. The Microfluidic Icyworld Chemical Analyzer (MICA), the next-generation WCL, is a standalone instrument package that incorporates the same classes of electrochemical sensors as WCL, but in a microfluidic format, enabling habitability assessment in a smaller instrument package (~2.3 kg, ~2 L).

R.C. Quinn↗

Detection of active and latent infections with microfluidic devices and systems thereof

The present invention relates to methods of detecting one or more targets of interest in a sample. In one instance, the target can be correlated to an active infection (e.g., by a virus and/or a bacterium). Methods can include treating the sample with a dissociation agent, thereby releasing the target of interest for more accurate detection (e.g., by use of a sedimentation-based centrifugal microfluidic devices). Also described herein are microfluidic devices and systems for use with a dissociation agent.

59 BASIC BIOLOGICAL SCIENCES↗

Protein and nucleic acid detection for microfluidic devices

The present invention relates to methods for detecting targets by employing a temperature control system with a microfluidic device. The system allows for non-contact heating by employing an infrared emitter. In some instances, the system can be used in conjunction with a centrifugal microfluidic device. Optionally, a mask can be implemented to provide selective heating of desired assay areas of the device.

Koh, Chung-Yan↗

Digital microfluidic systems and methods for droplet manipulation

The present disclosure relates to digital microfluidic systems. Particularly, aspects are directed to a digital microfluidic system that includes a droplet chip having a substrate, a plurality of electrodes and corresponding plurality of conducting vias or embedded conductive posts formed in the substrate, and a dielectric layer formed over the plurality of electrodes; and a control chip having a substrate, a plurality of transistors and corresponding wiring layers formed in the substrate, and a plurality of contacts formed over the plurality of transistors. Each of the plurality of contacts is electrically connected to a corresponding transistor of the plurality of transistors, and one or more of the plurality of contacts is removably connected to one or more of the plurality of conducting vias or embedded conductive posts such that one or more of the plurality of transistors are electrically connected to one or more of the plurality of electrodes.

Gach, Philip↗

Digital microfluidic systems with electrode bus and methods for droplet manipulation

The present disclosure relates to digital microfluidic systems having an electrode bus controlled by a single actuation input, and methods for droplet manipulation using the electrode bus. Particularly, aspects are directed to a digital microfluidic system including a first group of droplet actuation electrodes formed in a substrate, a first wiring bus formed in the substrate and connected to each electrode in the first group of droplet actuation electrodes, and a first single point of actuation connected to the first wiring bus; and a second group of droplet actuation electrodes formed in the substrate, a second wiring bus formed in the substrate and connected to each electrode in the second group of droplet actuation electrodes, and a second single point of actuation connected to the second wiring bus.

Gach, Philip↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗